Loading...
Tree Disposition Details_TD-2NOTE:THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESEPLANS IS BASED ON DESIGN DRAWINGS, RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTSTAKEN IN THE FIELD. THE DESIGNER DOES NOT GUARANTEE THAT LOCATIONS SHOWN ARE EXACT. THE CONTRACTOR MUST CONTACTTHE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OFUTILITIES. AS SUCH THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND UNCOVERING EXISTING UTILITIES IN THEVICINITY OF THE PROPOSED IMPROVEMENTS AND UTILITY CONNECTION POINTS PRIOR TO THE START OF CONSTRUCTION TO ASCERTAINEXACT MATERIALS, LOCATIONS, ELEVATIONS, ETC. AND THEIR POTENTIAL CONFLICT WITH PROPOSED IMPROVEMENTS. GC SHALLCONSULT WITH CONSTRUCTION MANAGER AND ENGINEER AS APPROPRIATE BEFORE PROCEEDING WITH WORK.Scale 1" = 20'10'40'20'0'1A2345678910111213BCDEFGHIDOCUMENTS PREPARED BY CORESTATES, INC.,INCLUDING THIS DOCUMENT, ARE TO BE USEDONLY FOR THE SPECIFIC PROJECT AND SPECIFICUSE FOR WHICH THEY WERE INTENDED. ANYEXTENSION OF USE TO ANY OTHER PROJECTS,BY OWNER OR BY ANY OTHER PARTY, WITHOUTTHE EXPRESSED WRITTEN CONSENT OFCORESTATES, INC. IS DONE UNLAWFULLY ANDAT THE USERS OWN RISK. IF USED IN A WAYOTHER THAN THAT SPECIFICALLY INTENDED,USER WILL HOLD CORESTATES, INC. HARMLESSFROM ALL CLAIMS AND LOSSES.Drawing: C:\Users\cmros\Dropbox (Rodney)\EDG - Shared\2021\McDonalds - Meridian ID\McDonald's Meridian TD.dwg ;TD-2Plot Date/Time: Jan. 27, 21 - 16:21:36User: CMROSSITE LOCATIONENGINEER SEAL4240 Jurupa Street Suite 402 Ontario, CA 91761 Phone (214) 377-6420 Fax (909) 467-8919 TPickering@core-states.comDOCUMENTREVISIONSREVDATECOMMENTBYCLIENTCHECKED BY:SHEET NO.JOB #:SCALE:DRAWN BY:DATE:SHEET TITLETHE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/ORELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON DESIGNDRAWINGS, RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE,MEASUREMENTS TAKEN IN THE FIELD. CORE STATES, INC. DOES NOT GUARANTEETHAT LOCATIONS SHOWN ARE EXACT. THE CONTRACTOR MUST CONTACT THEAPPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TOREQUEST EXACT FIELD LOCATIONS OF UTILITIES.FEASIBILITY SITEPLAN FORMCDONALDS ATMERIDIAN, ID1710 E. FAIRVIEW AVE,MERIDIAN, ID(011-0052)MCD.256511/27/2021CMRMcDonald's USA, LLC RR RM(800) 680-66301755 Telstar Dr., Ste 300Colorado Springs, CO 80920www.EvergreenDesignGroup.comD E S I G N G R O U PEVERGREENLA-16751**CHR I S TOPHER M. ROSES T A TE OF IDAHOLICENSED LANDSCAPE A R CHITECT01/27/21TREEDISPOSITIONDETAILSTD-21"=20'TUNNEL TO MINIMIZE ROOT DAMAGE (TOP) AS OPPOSED TO SURFACE-DUGTRENCHES IN ROOT PROTECTION ZONE WHEN THE 5' MINIMUM DISTANCEFROM TRUNK CAN NOT BE ACHIEVED.TREES THAT ARE MARKED TO BE PRESERVED ON A SITE PLAN AND FOR WHICHUTILITIES MUST PASS TROUGH THEIR ROOT PROTECTION ZONES MAY REQUIRETUNNELING AS OPPOSED TO OPEN TRENCHES. THE DECISION TO TUNNEL WILL BEDETERMINED ON A CASE BY CASE BASIS BY THE ENGINEER.TUNNELS SHALL BE DUG THROUGH THE ROOT PROTECTION ZONE IN ORDER TOMINIMIZE ROOT DAMAGE.(RPZ)ROOT PROTECTION ZONEIF BARE DIRT8" MULCH OUTSIDE RPZ ESTABLISH FENCE PROTECTIONMINIMUM 5' FROM TRUNK6" MULCH INSIDE RPZDRIP LINEOPEN TRENCHING MAY BE USED IF EXPOSED TREE ROOTS DO NOTEXCEED 3" OR ROOTS CAN BE BENT BACK.ROOT PROTECTION ZONE (RPZ)PROPERTY LINETREE TRUNKS T R E E T 5'CURBNOTES:1.THE FENCING LOCATION SHOWN ABOVE ISDIAGRAMATIC ONLY AND WILL CONFORM TO THEDRIP LINE AND BE LIMITED TO PROJECTBOUNDARY. WHERE MULTIPLE ADJACENT TREESWILL BE ENCLOSED BY FENCING, THE FENCINGSHALL BE CONTINUOUS AROUND ALL TREES.2.FOR ACCEPTABLE FENCING MATERIALS SEESPECIFICATIONS.AND UNDER DRIP LINE AS MINIMALPROTECTION FOR ROOTS FROMCONSTRUCTION ACTIVITIESNOTES:1.OPTION USED FOR TIGHT CONSTRUCTIONAREAS OR WHEN CONSTRUCTIONOCCURS IN ROOT PROTECTION ZONE.2.FOR ACCEPTABLE FENCING MATERIALSSEE SPECIFICATIONS.12" MIN & 48" MAX DEPTH TREE PROTECTION FENCESCALE: NOT TO SCALEABSCALE: NOT TO SCALETREE PROTECTION FENCE - TIGHT CONSTRUCTIONBORING THROUGH ROOT PROTECTION ZONESCALE: NOT TO SCALECROOT PROTECTION ZONE (RPZ)MULCH INSIDE RPZPROTECTION FENCE(SEE SPECS)DSCALE: NOT TO SCALEROOT PRUNING DETAILEXISTING GRADENOTES1.RETENTION AREAS WILL BE SET AS PART OF THE REVIEW PROCESS ANDPRE-CONSTRUCTION MEETING.2.BOUNDARIES OF RETENTION AREAS MUST BE STAKED AT THE PRE-CONSTRUCTIONMEETING AND FLAGGED PRIOR TO ROOT PRUNING.3.EXACT LOCATION OF ROOT PRUNING SHALL BE DETERMINED IN THE FIELD INCOORDINATION WITH THE FORESTRY INSPECTOR .4.TRENCH SHOULD BE IMMEDIATELY BACKFILLED WITH EXCAVATED SOIL OR OTHERORGANIC SOIL AS SPECIFIED PER PLAN OR BY THE FORESTRY INSPECTOR.5.ROOTS SHALL BE CLEANLY CUT USING VIBRATORY KNIFE OR OTHER ACCEPTABLEEQUIPMENT. ROT PRUNING METHODS AND MEANS MUST BE IN ACCORDANCE WITHANSI STANDARD A3000.6.ALL PRUNING MUST BE EXECUTED AT LOD SHOWN ON PLANS OR AS AUTHORIZEDIN WRITING BY THE FORESTRY INSPECTOR.7.SUPPLEMENTAL WATERING MAY BE REQUIRED FOR ROOT PRUNED TREESTHROUGHOUT THE GROWING SEASON DURING CONSTRUCTION AND SUBSEQUENTWARRANTY AND MAINTENANCE PERIOD.ROOT PRUNE VIA AIRSPACE ORTRENCH (6" WIDE MAX.) 24" MIN.DEPTH OR AS DETERMINED ATPRE-CONSTRUCTION MEETING.TREE PROTECTION FENCE TOBE ERECTED IN LINE WITHROOT PRUNING LIMITS. SEEDETAILS AND SPECIFICATIONSFOR TREE PROTECTIONFENCE REQUIREMENTS.