PZ - Pre-app Notes CITY OF MERIDIAN PRE-APPLICATION MEETING NOTES Project/Subdivision Name: Fairway Townhomes Date:11/17/20& 1/5/21 Applicant(s)/Contact(s): Matt Drown, Sam McCaskill, Pam Weatherly, Don Newell,Andrew Newell City Staff: Sonya, Bill, Miranda, Joe, Tom, Caleb, Codee, Steve Location: 1789 N. Hickory Way(Parcel#R5446410038) Size of Property: 1.97 Comprehensive Plan FLUM Designation: Commercial Existing Use: Vacant/undeveloped land Existing Zoning: L-0 Proposed Use: Single-family attached &townhouse dwellings (20 units((Dl0+/-units/acre) Proposed Zoning: R-15 Surrounding Uses: SFR, church, restaurant, retail, bank, personal/professional services Street Buffer(s)and/or Land Use Buffer(s): 20'along Hickory, a collector street, landscaped per the standards in UDC 11-3B-7C—the existing plat depicts a 25'wide landscape easement along the northwest boundary abutting Dove Meadows Sub. (this could be removed if residential uses are proposed) Open Space/Amenities/Pathways: No pathways are depicted on the PMP; no minimum open space/amenities are required Access/Stub Streets/Street System:Access should be taken via the shared driveway along east boundary from N. Hickory Way; private streets for internal access—the existing plat(Mallane Sub.)prohibits new access points via Hickory Way&states all lots are subject to common cross-access/ingress-egress.Work with Mallane's to possibly extend private street off-site to Hickory. Waterways/Topography/Flood Plain: NA Sewer/Water: Existing water to the north, south &east;water main is required to have a dual connection. Sewer is available in Hickory Way,flow is committed. History:Annexed &subdivided in 1992 as Angel Park Sub. (Lot 1, Block 1)w/L-0 zoning; re-subdivided in 2001 (Mallane Commercial Complex PP-00-021); FP-03-001 (Lot 4, Block 1 -per the plat, all lots in the subdivision are required to obtain CUP prior to construction commencing on the lots—w/re-subdivision that requirement will be removed); Hickory Apartments(H-2017-0165—RZ&CUP)-Denied Additional Meeting Notes: ■ Amendment to the Future Land Use Map in the Comprehensive Plan to change the land use designation from Commercial to Medium High—Density Residential (density should range from 8-12 units/acre) (As an alternative, rezone to C-C or C-G for a multi- family development which requires CUP approval in C-C or C-G and apply for a short plat to condo the airspace of each unit.) ■ Rezone from L-0 to R-15 for the development of townhomes—single-family attached &townhouse dwellings are principal permitted uses in the R-15 district. ■ Preliminary plat to re-subdivide property; comply with the dimensional standards of the R-15 district in UDC Table 11-2A-7 and the subdivision design&improvement standards in UDC 11-6C-3C ■ The existing plat(Mallane Sub)depicts a 10'PUDI easement&25'landscape easement along NW boundary&a 10'PUDI easement along west&north boundaries;a sanitary sewer, water main&public utilities easement is depicted along east boundary. ■ Private streets are required to comply with the standards listed in UDC 11-3F-4—it's not the intent of the UDC to approve private streets for townhouse developments other than those that create a common mew through the site design or that proposed a limited gated residential development per UDC 11-3F-1.Applicability may be extended where the Director or Fire Marshall determines private streets will enhance the safety of the development. Provide iustification for private streets in application narrative.Alternative Compliance may be requested to the standards in UDC 11-3F-4(private streets)and 11-6C-3(common driveways)—see UDC 11- 5B-5 for more information on alternative compliance requirements/process. ■ Lack of parking for quests is a concern; adequate parking s/b provided on the site to accommodate the needs of the development. ■ The design of the townhomes is required to comply with the standards in the Architectural Standards Manual; submit concept elevations with application that are consistent with these standards. ■ Work with Terri Ricks or Ryan Beecroft in Land Development on addressing for the units. Note:A Traffic Impact Study(TIS) will be required by ACHD for large commercial projects and any residential development with over 100 units. To avoid unnecessary delays&expedite the hearing process, applicants are encouraged to submit the TIS to ACHD prior to submitting their application to the City. Not having ACHD comments and/or conditions on large projects may delay hearing(s)at the City. Please contact Mindy Wallace at 387- 6178 at ACHD for information in regard to a TIS, conditions,impact fees and process. Other Agencies/Departments to Contact: X Ada County Highway Dist. (ACHD) ❑ Nampa Meridian Irrigation Dist. (NMID) ❑ Public Works Department ❑ Idaho Transportation Dept. (ITD) ❑ Settler's Irrigation District(SID) ❑ Building Department ❑ Republic Services ❑ Police Department ❑ Parks Department ❑ Central District Health Department 0 Fire Department ❑ Other: CITY OF MERIDIAN PRE-APPLICATION MEETING NOTES Application(s) Required: ❑ Administrative Design Review ❑ Conditional Use Permit Mod ification/Transfer X Rezone ❑ Alternative Compliance ❑ Development Agreement Modification ❑ Short Plat ❑ Annexation ❑ Final Plat ❑ Time Extension—Council ❑ City Council Review ❑ Final Plat Modification ❑ UDC Text Amendment X Comprehensive Plan Amendment—Map ❑ Planned Unit Development ❑ Vacation ❑ Comprehensive Plan Amendment—Text X Preliminary Plat ❑ Variance ❑ Conditional Use Permit X Private Street ❑ Other Notes: 1)Applicants are required to hold a neighborhood meeting in accord with UDC 11-5A-6C prior to submittal of an application requiring a public hearing(except for a vacation or short plat);and 2)All applicants for permits requiring a public hearing shall post the site with a public hearing notice in accord with UDC 11-5A-5D.3(except for UDC text amendments, Comp Plan text amendments, and vacations). The information provided during this meeting is based on current UDC requirements and the Comprehensive Plan.Any subsequent changes to the UDC and/or Comp Plan may affect your submittal and/or application. This pre-application meeting shall be valid for four(4)months. �WENty LAND DEVELOPMENT MEETING NOTES Land Development Staff: Steve O'Brien Date: 1/5/2021 Project Name and Location: Fairway Homes Is sanitary sewer available? Yes: ❑X No: ❑ Notes: Is domestic water available? Yes: ❑x No: ❑ Notes: Easements Required? Yes: ❑X No: ❑ NOTE: easements may not overlap any permanent structure including but not limited to carports,trash enclosures, trees, shrubs, buildings, etc.Service lines up to the meter pit must be in ROW or covered by an easement. Notes: Is the project within 500 feet No Is this a commercial No of a re-use main? project? If both reuse questions are"yes" provide the following information: Building use(manufacturer,carwash,etc.), hours of operation, approximate business water usage and irrigable landscape area: Floodplain or other hazards? Yes: ❑ No: ❑X Notes: Irrigation District: Nampa Meridian Irrigation District Notes: The pressurized irrigation system is owned and maintained by NMID. 1 1 P a g e CVENty Public streetlights required? Yes: ❑ No: ❑X Notes: Not needed as private streets are proposed for this development. Submittal of Civil Infrastructure requirements: When submitting civil drawings for the project follow these guidelines: Submit an electronic version of the construction drawings in PDF format. Submit an AutoCAD file in compliance with the Specifications for Project Drawings as listed on the next page. Engineering construction drawings will need to show streets,water, sewer, sidewalks, Irrigation, onsite stormwater system, and other public improvements.These drawings must be stamped and signed by a registered engineer/surveyor in the State of Idaho. Additional Meeting Notes: 2 1 P a g e Auto CAD Standards All drawings shall be delivered 100%AutoCAD DWG format and 100%editable,but at the consultant's discretion, may be submitted in an un-editable media like CD-ROM. Both Digital and Hard Copy documents shall match. Record drawing items must match their true location. Survey Topographic surveys shall be delivered in NAD 83 Idaho State Plane west zone coordinates modified to the Ada County Local GIS Coordinates (Horizontal), NAVD 88 (vertical). Both Horizontal and Vertical information must be accounted for. File Names Project Name_WAT_SEW_PRELIM.dwg for Preliminary or Pre Plat Project Name_WAT_SEW_CONST.dwg for Final Plat or Approved Construction Project Name_WAT_SEW_REC.dwg for Record Drawings Layer Names Color Description BOUNDARY SUB GREY Subdivision boundary line FLOODPLAIN BLUE Floodplain outline FLOODWAY CYAN Floodway outline IRR_GRAVITY BROWN Gravity irrigation line IRR_GRAVITY_MANHOLE BROWN Gravity irrigation manhole IRR_GRAVITY_SERVICE BROWN Gravity irrigation services IRR_GRAVITY_VALVES BROWN Gravity irrigation valves IRR_ORAVITY_PUMPS BROWN Gravity irrigation pumps IRR_GRAVITY_BOX BROWN Gravity irrigation box IRR_PRESSURE MAGENTA Pressure irrigation line IRR_PRESSURE_MANHOLE MAGENTA Pressure irrigation manhole IRR_PRESSURE_SERVICE MAGENTA Pressure irrigation services IRR_PRESSURE VALYES MAGENTA Pressure irrigation valves IRR_PRESSURE_PUMPS MAGENTA Pressure irrigation bumps IRR_PRESSURE BOX MAGENTA Pressure irrigation box RECORD LOTS GREY Lot lines of parcel SEWER AIRVAC GREEN Air Vacuum System SEWER (pipe size) GREEN Sewer line(separate layer for each size) SEWER_CASING SEWER_ GREEN Sewer casing CLEANOUT GREEN Sewer cleanouts SEWER_LIFT—STATION GREY Lift Station SEWER MANHOLE GREEN Sewer manhole SEWER_PRESS_(pipe size) GREEN Pressure sewer line(separate layer for each size) SEWER SERVICES GREEN Sewer service line ST_LIGHT WHITE Streetlight STORM_DRAIN CYAN Storm drain line Storm STORM MANHOLE CYAN drain manhole Storm STORM_CATCHBASIN CYAN drain catch basin Storm STORM_SAND_TRAP CYAN drain sand trap Storm STORM_GREASE_TRAP CYAN drain grease tmp Storm STORM_SEEPAGE_BEDS CYAN drain seepage beds Storm STORM_PONDS CYAN drain ponds TEXT LOTS WHITE Lot and block number TEXT_STREETNAMES WHITE Street name TEXT_SUBDIVISIONS CYAN Subdivision name WATER AIRVAC BLUE Air Vacuum System WATER_(pipe size) BLUE Water line(separate layer for each size) WATER BLOWOFF BLUE Water blow off WATER BOOSTER BLUE Booster WATER_CASING BLUE Watercasing WATER_FIRE_LINE CYAN Fire line WATER HYDRANT CYAN Fire hydrant WATER_HYDRANT_LINES CYAN Fire hydrant lines WATER METER BLUE Water meter WATER_PIV MAGENTA Pressure irrigation valve WATER_PRV BLUE Pressure reducing valve WATER SERVICES BLUE Water service line WATER VALVES BLUE Water valve WATER WELLS GREY Well house Item Formatting Use thinner line weights and lighter colors for existing items.Lines must connect and if part of a polygon snapped closed.Use blocks provided in the template drawing for points. Please refer to sample drawing. In AutoCAD terminology,a closed line is a polygon. Appendix A: Company Templates Company templates were added to the Public Works AutoCAD standard to allow companies that already have a design standard in place to continue to use that standard,provided that the necessary information is present and can be extracted.If your company does not have a standard in place the Public Works Department has created a template that follows this guideline to help your company comply with the standards more easily.We encourage you to take advantage of these resources. The Meridian Public Works Department will make every attempt to use your company's existing standard.However there are several requirements that must be met and may require a change in your company's template.These are outlined below: • File Names must define project and status in planning process • Items of different types/size must be discernable from each other o Sewer lines broken out by size. • Survey Projection must conform to location of project o Correct UTM Zone for Ada County • Lines must be snapped and closed and solid o No text breaking up the line o This is for water and sewer modeling purposes Company standard must be compatible with the Public Works GIS Processing.The above guidelines will help your standard complete the standards approval process more easily.Remember your company standard must be pre- approved before drawings will be accepted.If your company has not completed the pre-approval process all drawings must comply with the Meridian Public Works AutoCAD standards in order for drawings to be accepted.