Loading...
Floor Plan with dimensionsB3 A-201 C1 A-201 B1 A-201 A1 A-201 A A B B C C D D E E F F G G 33 22 1 1 26'-4"24'-0"24'-0"24'-0"27'-5 1/4"21'-3 3/8" OPEN TO GRADE 1'-4 5/8"2'-0"11'-4"11'-4"2'-0"9"22'-7"8"2'-0"19'-9"2'-3"4'-8"17'-4"2'-0"2'-0"6'-8"6'-8"4'-0"2'-8"5'-5 1/4" 1'-2 3/4" 9'-4"9'-4" 1'-4 5/8" 1'-3 3/8"8'-10"17'-6"2'-0"11'-2"11'-2"2'-2"1'-4 5/8"2'-0"26'-4"5'-6"4'-10 1/4"3'-6 1/2"12'-7 1/4"2'-2 3/4"52'-10"C2 A-301 C4 A-301 A2 A-301 C2 A-302 C4 A-302 A2 A-302 TENANT B 103 TENANT A 100 RESTROOM 101 LANDLORD ROOM 102 100'-0" 147'-0 5/8"26'-4"26'-6"14'-4"9'-8"8'-10"11'-8"6'-11 1/4"17'-6 3/4"3'-8 5/8"24'-0"2'-4"2'-8"26'-6"2'-0" 13'-10 1/4"7'-1 3/8"OPEN TO GRADE8'-11 1/2"100'-0"8'-5 3/8"10'-2 3/8" 99'-8" 99'-8" 100'-0"2'-0"A.1 A.1 H G F E D C B A J 100A AA 103A CC 103B GG 103CHH103D-103E HMA 103F HMA 103G - 102 HMA 100B HMA A-411 A4 W6A W6AW8G 10.01 D4 A-301 • SEE WALL TYPES FOR FINISH SHEATHING. TAPE AND SAND GYP WHERE USED. • SEE INTERIOR ELEVATIONS FOR ADDITIONAL FINISH INFROMATION • SEE REFLECTED CEILING PLANS FOR ADDITIONAL FINISH INFORMATION • KEYNOTES: THE FIRST TWO NUMBERS REPRESENT THE RELATED CSI MASTER FORMAT DIVISION. THE SECOND SET OF NUMBERS REPRESENTS AN IDENTIFYING MARK VALUE. NOT ALL VALUES MAY BE USED OR OCCUR IN THE DOCUMENT SET. ADDITIONALLY, KEYNOTES RETAIN THEIR ASSIGNED VALUE UNIVERSALLY THROUGHOUT THE SET. THE KEYNOTES LISTED BELOW, REPRESENT THE KEYNOTES FOUND AND UTILIZED ON THIS SHEET AND EACH LIST WILL DIFFER RESPECTIVE TO ITS' SHEET. THEREFORE, BASED ON ACTUAL KEYNOTES UTILIZED ON A GIVEN SHEET OF DRAWINGS, GAPS IN THE SEQUENCING WILL OCCUR. • HOLLOW METAL FRAME AND ALUMINUM WINDOW TYPES ARE SHOWN ON SHEET SERIES A-570. DIMENSIONS TO FRAMES WILL BE TO OUTSIDE EDGE OF FRAME. SEE BOTH THE FLOOR PLAN AND EXTERIOR ELEVATIONS FOR ALL WINDOW TYPE REFERENCES • SEE SHEET SERIES G-003 & A-611 FOR ALL FIRE WALLS, SMOKE WALLS, WALLS TO CEILING LEVEL, SOUND WALLS • FEC = FIRE EXTINGUISHER IN SEMI-RECESSED CABINET • INDICATES INTERIOR ROOM ELEVATIONS ON SHEET REFERENCED • ROLLER SHADES PER FINISH PLANS 1t Z1/Y-123 # © COPYRIGHT DESIGN WEST ARCHITECTS 202154321 A B D C design westarchitects255 SOUTH 300 WEST795 NORTH 400 WESTLOGAN UT 84321SALT LAKE CITY UT 84103PROJECT #: DRAWN BY: CHECKED BY: ISSUED:1/13/2021 6:23:31 PMWADSWORTH - OASIS / JAMBA JUICE3085 EAST USTICK ROAD420665 NIELSON ZETTERQUIST 2.5.2021 PLAN - DIMENSION, ANNOTATION, FINISH A-101NOT FOR CONSTRUCTIONWADSORTH DEVELOPMENT GROUPMERIDIAN, IDMARK DESCRIPTION 10.01 LADDER GENERAL NOTES KEYNOTES # • LEGAL: THE CONSTRUCTION DOCUMENTS FOR THIS PROJECT ARE COMPOSED OF SETS OF DRAWINGS AND SPECIFICATIONS, AND THEREFORE SHALL BE USED AND MAINTAINED IN THEIR ENTIRETY. ANY CONTRACTOR, SUBCONTRACTOR, VENDOR OR PARTY PARTICIPATING IN OR BIDDING ON THIS PROJECT SHALL BE EXPECTED TO PERFORM DUE DILIGENCE TO ENSURE THEIR BID, WORK PERFORMED, AND MATERIALS PROVIDED CONFORMS TO THE INFORMATION PROVIDED WITHIN ANY AND ALL SHEETS OF DRAWINGS AND SPECIFICATIONS, INCLUDING, BUT NOT LIMITED TO, ANY SUBSEQUENT ADDENDA OR CLARIFICATIONS THAT MAY BE ISSUED RELEVANT TO THEIR SCOPE OF WORK.PROJECT SCOPE MAY BE DEFINED WITHIN SPECIFICATIONS AND/OR DRAWINGS. ADDITIONALLY, DRAWINGS MAY NOT BE RE-SCALED WHEN PRINTED, WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE, AND LARGER SCALE DRAWINGS SHALL HAVE PRECEDENCE OVER SMALLER SCALE DRAWINGS. ANY DEVIATION FROM OR CONFLICT WITHIN THE DRAWINGS AND/OR SPECIFICATIONS, MUST BE SUBMITTED TO AND APPROVED BY THE ARCHITECT BEFORE CONTINUING THAT PORTION OF WORK. • CONTRACTOR SHALL VERIFY LAY-OUT OF STRUCTURAL, MECHANICAL, AND ELECTRICAL. • ALL INTERIOR DIMENSIONS ARE TO/FROM FACE OF STUD / MASONRY. ALL EXTERIOR DIMENSIONS ARE TO/FROM FACE OF GRID/FOUNDATION. DIMENSIONS MARKED 'CLEAR' OR 'CLR' ARE FROM FACE OF FINISH TO FACE OF FINISH AND SHALL BE MAINTAINED AND CANNOT BE FIELD ADJUSTED WITHOUT PRIOR APPROVAL OF THE ARCHITECT. 1/8" = 1'-0" A1 PLAN - DIMENSION, ANNOTATION, FINISH NORTH MARK:DATE:DESCRIPTION: