Loading...
Public Utility PlanBLOCK 112''SD12''SD12''SD12''SD15''SD15''SD12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W 4''SS 6''SS 6''SS 6''SS 6''SS EPEPEPEPEP 12''SD 12''SD 12''SD 12''SD 12''SDGMTRT SDPAD ASHOPS/RESTAURANTALBERTSON'SFSFS8''SD 12''SD12''SD12''SDSDSD YIELDYIELDYIELDBUILDING WORKSITE WORKBUILDING WORK SITE WORK BUILDING WORKSITE WORK PIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRR PIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRR12''SD 12''SD 12''SD 12''SD 12''SDSD VANVANVAN18''SDPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRR SEE C3.14 - E. MOUNT ETNA DR. SEWER PLANSEE C3.13 - E. MOUNT ETNA DR. SEWER PLANPROPOSED BUILDINGFF: 2679.83= 100'-00" (ARCH.)SEE C3.15 - ROADWAY WATER PLANE. Mount Etna Dr.S. Cubola Ave.156-LF OF 6-IN PVC AT 2.00%17-LF OF 6-IN PVC AT 2.00%12-LF OF 6-IN PVC AT 2.00%6-IN PVCIE: 2668.556-IN PVCIE: 2667.98SEE L2.01 - AREA 1SEE C3.15 - ROADWAY WATER PLANSEE C3.15 - ROADWAY WATER PLANProject Name: Revisions This document and the information contained herein may not be copied or reproduced without express written permission of The Land Group, Inc. Unauthorized disclosure or construction use are prohibited by copyright law.Date of Issuance:Project No.:Designed by:Checked by:Sheet No.:Sheet Title: Firenze Plaza NWC Eagle Road & Amity Road Site Improvement Plans Meridian Idaho1160159.22.2020RC/MTGW/DRHORIZONTAL SCALE: 1" = 20'20'40'0File Location:g:\2016\116015\cad\116015 cd c501 site utility plan.dwgLast Plotted By:gabe welzDate Plotted:Tuesday, September 22 2020 at 04:36 PM C5.01Site Utility Area 1 Sewer And Water PlanSite Utility - Area 1 Sewer and Water PlanSheet Notes:1.CONTRACTOR SHALL COMPLY WITH ALL NOTES ON SHEETS C1.00 AND C1.01.Keynotes:#1.SANITARY SEWER CONNECTION TO GREASE INTERCEPTOR. COORDINATE WITHSITE MECHANICAL PLANS FOR CONTINUATION.2.SANITARY SEWER CONNECTION. COORDINATE WITH SITE MECHANICAL PLANSFOR CONTINUATION.3.POTABLE / NON-POTABLE WATER SERVICE CROSSING - SEE CITY OF MERIDIANWATER NOTE NO. 3 ON SHEET C1.01.APPROVED FORCONSTRUCTIONNameDateIDAHOThese plans and/or specifications have been reviewed for compliance withMeridian City Standards and Specifications. This review does not relieve theowner, engineer, or contractor of the responsibility to design and/or constructthose facilities in compliance with all current applicable federal, state and locallaws, rules, regulations, ordinances, development agreements, specifications,orders or approvals, all of which the City retains the right to enforce.inconsistencies not noted by City staff shall not be construed as approvedunless specifically addressed in writing by the City. Any proposed revision tothese plans must be submitted for review and compliance with the MeridianCity Standards and Specifications before said revision is constructed.12Legend:8''WPROPERTY BOUNDARY LINELOT LINEINGRESS/EGRESS & PUBLIC UTILITY EASEMENTLINE8" WATER MAIN (OR AS NOTED)GATE VALVEFIRE HYDRANT PER CITY OF MERIDIAN DETAILW7BLOW-OFF VALVE PER CITY OF MERIDIANDETAILS W12 OR W13THRUST BLOCKEXISTING WATER MAIN (SIZE NOTED)EXISTING BLOW-OFF ASSEMBLYEXISTING GATE VALVEEXISTING FIRE HYDRANTSEWER MAIN (SIZE NOTED)EXISTING SEWER MAIN (SIZE NOTED)PRESSURE IRRIGATION (SIZE NOTED)EXISTING PRESSURE IRRIGATION (SIZE NOTED)GRAVITY IRRIGATION LINE (SIZE NOTED)EXISTING GRAVITY IRRIGATION LINE (SIZENOTED)WWTR8''SSWTRWTR8''SSPIRRPIRRGIRRGIRRP/LMATCH LINE - SEE SHEET C5.03MATCH LINE - SEE SHEET C5.0233 09/22/2020 FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO 12''W12''W12''W12''W12''W12''W12''W12''W12''W12''WGGGGGGGGGGGGGGGGGGGGGGGGGGGGGFMFMFMFMFMFMFMFMFMFMFMFMFMR/W R/W R/W R/W R/W R/W R/W R/W R/WR/WR/WR/W R/W R/W R/W R/W R/W R/W FOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFO R/W R/W R/W R/W R/W R/W R/W R/W GIRR GIRRGIRREG EGEGEGEGEGEGUGPGGGGGTIRRIRR4''SS4''SSEP EP EP EP EP EP 8''SS MTR8''W8''W 8''W8''W8''W8''W 8''W8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SSSANSANEPEPEP EP EP EP EP PAD BFUEL CENTERPAD CBANKEP8''SS 8''SS 8''SSYIELD FUEL CENTER WORKSITE WORKSITE WORKFUEL CENTER WORKSITE WORK SITE WORK FUEL CENTER WORK FUEL CENTER WORK EP EP EP EP EP EP EP EP EPEPEPEPEPPIRR PIRR PIRR PIRR PIRR PIRR PIRR PIRRPIRRPIRRPIRRPIRRPIRRVANVANVANPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRR3+004+005+00 6+00 118-LF 8-IN C900 14-LF 6-IN C900SEE C3.15 - ROADWAY WATER PLANCITY OF MERIDIANINGRESS/EGRESS &PUBLIC UTILITYEASEMENT59-LF 8-IN C900 15-LF 8-IN C900181-LF 8-IN C900 4132S. Eagle Rd.E. Mount Etna Dr.10.8'(10' MIN.)SEE L2.02 - AREA 26711-LF 1-IN PE80-LF 8-IN C90040-LF 8-IN C900 80'40'88Project Name: Revisions This document and the information contained herein may not be copied or reproduced without express written permission of The Land Group, Inc. Unauthorized disclosure or construction use are prohibited by copyright law.Date of Issuance:Project No.:Designed by:Checked by:Sheet No.:Sheet Title: Firenze Plaza NWC Eagle Road & Amity Road Site Improvement Plans Meridian Idaho1160159.22.2020RC/MTGW/DRHORIZONTAL SCALE: 1" = 20'20'40'0File Location:g:\2016\116015\cad\116015 cd c501 site utility plan.dwgLast Plotted By:gabe welzDate Plotted:Tuesday, September 22 2020 at 04:36 PM C5.02Site Utility Area 2 Sewer And Water PlanSite Utility - Area 2 Sewer and Water PlanSheet Notes:1.CONTRACTOR SHALL COMPLY WITH ALL NOTES ON SHEETS C1.00 AND C1.01.Keynotes:#1.POTABLE WATER MAIN CROSSING - SEE CITY OF MERIDIAN WATER NOTE NO. 2ON SHEET C1.01. (NOT USED ON THIS SHEET)2.INSTALL FIRE HYDRANT ASSEMBLY PER CITY OF MERIDIAN SUPPLEMENTALDRAWING SD-W8. INSTALL 1-8"x8"x6" TEE (MJxMJxFLG) WITH 1-6" GATE VALVE(FLGxMJ) PER CITY OF MERIDIAN SUPPLEMENTAL DRAWING SD-W11. THRUSTBLOCK AS REQUIRED.3.INSTALL 1-8"x8"x8" TEE (MJxMJxFLG) WITH 1-8" GATE VALVE (FLGxMJ) PERCITY OF MERIDIAN SUPPLEMENTAL DRAWING SD-W11. THRUST BLOCK ASREQUIRED.4.INSTALL 2" BLOW OFF ASSEMBLY PER MERIDIAN SUPPLEMENTAL DRAWINGSD-W12.5.CAP AND MARK END PER ISPWC SD-512.6.INSTALL 1" WATER SERVICE CONNECTION WITH 1" METER AND 1" METERSETTER PER CITY OF MERIDIAN SUPPLEMENTAL DRAWING SD-W2.7.POTABLE / NON-POTABLE WATER SERVICE CROSSING - SEE CITY OF MERIDIANWATER NOTE NO. 3 ON SHEET C1.01.8.PROVIDE 0.5 DEGREE JOINT DELFLECTION AT EACH PIPE JOINT (20-FT PIPELENGHTS). JOINT DEFLECTION SHALL NOT EXCEED HALF THE PIPEMANUFACTURER'S ALLOWABLE DEFLECTION. CONTRACTOR SHALL VERIFY THEDEFLECTION ANGLE.APPROVED FORCONSTRUCTIONNameDateIDAHOThese plans and/or specifications have been reviewed for compliance withMeridian City Standards and Specifications. This review does not relieve theowner, engineer, or contractor of the responsibility to design and/or constructthose facilities in compliance with all current applicable federal, state and locallaws, rules, regulations, ordinances, development agreements, specifications,orders or approvals, all of which the City retains the right to enforce.inconsistencies not noted by City staff shall not be construed as approvedunless specifically addressed in writing by the City. Any proposed revision tothese plans must be submitted for review and compliance with the MeridianCity Standards and Specifications before said revision is constructed.Legend:8''WPROPERTY BOUNDARY LINELOT LINEINGRESS/EGRESS & PUBLIC UTILITY EASEMENTLINE8" WATER MAIN (OR AS NOTED)GATE VALVEFIRE HYDRANT PER CITY OF MERIDIAN DETAILW7BLOW-OFF VALVE PER CITY OF MERIDIANDETAILS W12 OR W13THRUST BLOCKEXISTING WATER MAIN (SIZE NOTED)EXISTING BLOW-OFF ASSEMBLYEXISTING GATE VALVEEXISTING FIRE HYDRANTSEWER MAIN (SIZE NOTED)EXISTING SEWER MAIN (SIZE NOTED)PRESSURE IRRIGATION (SIZE NOTED)EXISTING PRESSURE IRRIGATION (SIZE NOTED)GRAVITY IRRIGATION LINE (SIZE NOTED)EXISTING GRAVITY IRRIGATION LINE (SIZENOTED)WWTR8''SSWTRWTR8''SSPIRRPIRRGIRRGIRRP/LMATCH LINE - SEE SHEET C5.01 MATCH LINE - SEE SHEET C5.04SEE C5.05-C5.06 - SEWER MAIN B PLAN09/22/2020 T 50.31' ROW 65.27' ROW EGEGEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEP EPEPEPEPEPEPEPEPEPEPEPEPEPEP15''GIRR15''GIRR15''GIRR15''GIRR15''GIRR15''GIRR12''GIRR12''GIRR12''GIRR12''GIRR12''GIRR12''GIRR12''GIRR12''W12''W12''W12''W12''W12''W12''W 8''W8''W6''SS6''SS8''W8''W8''W8''W8''W8''W8''WEP 12''SDTSD12''SD12''SD12''SD15''GIRR12''GIRRGIRRGIRREP EPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPPAD FFAST FOODALBERTSON'SFSFS8''SDSDYIELDYIELD15''GIRR15''GIRR12''GIRR12''GIRRBUILDING WORKSITE WORKBUILDING W SITE WORKGIRRGIRREPGIRR EPEPEPEP EP EP EPEPEPGIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRR PIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRGIRRMTR PIRRPIRRPIRR P I R RPIRRPIRRPIRRPIRRPIRRPIRRPIRR37-LF 8-IN C90034-LF 8-IN C900113-LF 8-IN C900SEE ROADWAY UTILITY PLAN SHEET C3.15 FOR CONTINUATION116-LF 8-IN C90022-LF 8-IN C900175-LF 8-IN C9002431552PROPOSED BUILDINGFF: 2679.83= 100'-00" (ARCH.)S. Cubola Ave.100-LF OF 4-IN PVC AT 2.00%SS STRC 3.054" CLEANOUT PERISPWC SD-506ARIM: 2680.42±IE IN: 2671.80, 4-IN PVC (W)IE OUT: 2671.80, 4-IN PVC (E)4-IN PVCIE: 2673.806Amity Rd.SEE C3.15 - ROADWAY WATER PLANSEE L2.03 - AREA 3130-LF 8-IN C900135°135°SEE C3.15 - ROADWAY WATER PLANSEE L2.03 - AREA 3Project Name: Revisions This document and the information contained herein may not be copied or reproduced without express written permission of The Land Group, Inc. Unauthorized disclosure or construction use are prohibited by copyright law.Date of Issuance:Project No.:Designed by:Checked by:Sheet No.:Sheet Title: Firenze Plaza NWC Eagle Road & Amity Road Site Improvement Plans Meridian Idaho1160159.22.2020RC/MTGW/DRHORIZONTAL SCALE: 1" = 20'20'40'0File Location:g:\2016\116015\cad\116015 cd c501 site utility plan.dwgLast Plotted By:gabe welzDate Plotted:Tuesday, September 22 2020 at 04:36 PM C5.03Site Utility Area 3 Sewer And Water PlanSite Utility - Area 3 Sewer and Water PlanAPPROVED FORCONSTRUCTIONNameDateIDAHOThese plans and/or specifications have been reviewed for compliance withMeridian City Standards and Specifications. This review does not relieve theowner, engineer, or contractor of the responsibility to design and/or constructthose facilities in compliance with all current applicable federal, state and locallaws, rules, regulations, ordinances, development agreements, specifications,orders or approvals, all of which the City retains the right to enforce.inconsistencies not noted by City staff shall not be construed as approvedunless specifically addressed in writing by the City. Any proposed revision tothese plans must be submitted for review and compliance with the MeridianCity Standards and Specifications before said revision is constructed.Legend:8''WPROPERTY BOUNDARY LINELOT LINEINGRESS/EGRESS & PUBLIC UTILITY EASEMENTLINE8" WATER MAIN (OR AS NOTED)GATE VALVEFIRE HYDRANT PER CITY OF MERIDIAN DETAILW7BLOW-OFF VALVE PER CITY OF MERIDIANDETAILS W12 OR W13THRUST BLOCKEXISTING WATER MAIN (SIZE NOTED)EXISTING BLOW-OFF ASSEMBLYEXISTING GATE VALVEEXISTING FIRE HYDRANTSEWER MAIN (SIZE NOTED)EXISTING SEWER MAIN (SIZE NOTED)PRESSURE IRRIGATION (SIZE NOTED)EXISTING PRESSURE IRRIGATION (SIZE NOTED)GRAVITY IRRIGATION LINE (SIZE NOTED)EXISTING GRAVITY IRRIGATION LINE (SIZENOTED)WWTR8''SSWTRWTR8''SSPIRRPIRRGIRRGIRRP/LSheet Notes:1.CONTRACTOR SHALL COMPLY WITH ALL NOTES ON SHEETS C1.00.Keynotes:#1.POTABLE WATER MAIN CROSSING - SEE CITY OF MERIDIAN WATER NOTE NO. 3ON SHEET C1.01.2.INSTALL FIRE HYDRANT ASSEMBLY PER CITY OF MERIDIAN SUPPLEMENTALDRAWING SD-W8. INSTALL 1-8"x8"x6" TEE (MJxMJxFLG) WITH 1-6" GATE VALVE(FLGxMJ) PER CITY OF MERIDIAN SUPPLEMENTAL DRAWING SD-W11. THRUSTBLOCK AS REQUIRED.3.INSTALL 1-8"x8"x8" TEE (MJxMJxFLG) WITH 1-8" GATE VALVE (FLGxMJ) PERCITY OF MERIDIAN SUPPLEMENTAL DRAWING SD-W11. THRUST BLOCK ASREQUIRED.4.INSTALL 2" BLOW OFF ASSEMBLY PER MERIDIAN SUPPLEMENTAL DRAWINGSD-W12.5.INSTALL 45° BEND (MJxMJ). THRUST BLOCK AS REQUIRED.6.CAP AND MARK END PER ISPWC SD-512.MATCH LINE - SEE SHEET C5.01MATCH LINE - SEE SHEET C5.04 09/22/2020 F O F O F O F O F O F O F O FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO T TTTTTTTTTTTTTTTT12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''WFT61'ROWG GGGGGGGGGGGGGGGGGGGGGGGGGGGFMFMFMFMFMFMFMFMFMFMFMFMFMR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WFOFOFOFOFOFO GIRRGIRRGIRRIRREECEIRRIRRSD SD SD SD SDSDGIRRGIRRSD SD SD SD SD SD SD SD SD SD8''W8''W8''W8''W6''SS6''SS6''SS6''SS8''W8''W8''W8''W8''W8''SS8''SS8''SS8''SS8''SS8''SSSANEP EPEPEPEPEPEPEPEPEPEPE P EP EP EP EP EPEPEPEP EP EP EP PAD CBANKPAD DRESTAURANTPAD ERESTAURANTYIELDEP EP EP EP EP EPEPEPEP EPEPEPEPEPE P EP EP EPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPE P E P E P E P EP EP EP EP EP EP EPEPEP EP EP EP EPPIRRPIRRPIRRPIRRPIRRPIRRPIRR PIRRPI R R PIRR PIRR PIRR PIRR PIRR PIRR PIRRPIRRPIRR 6+00 7+00 24-LF 8-IN C9007-LF 8-IN C90027-LF 8-IN C900181-LF 8-IN C900 1175-LF 8-IN C9005534111223426-LF 6-IN C90012-LF 8-IN C90049-LF 8-IN C900 31-LF 8-IN C900S. Eagle Rd.Amity Rd.23-LF OF 4-IN PVC AT 2.00%100-LF OF 4-IN PVC AT 2.00%100-LF OF 4-IN PVC AT 2.00%SS STRC 3.054" CLEANOUT PERISPWC SD-506ARIM: 2680.42±IE IN: 2671.80, 4-IN PVC (W)IE OUT: 2671.80, 4-IN PVC (E)SS STRC 3.044" CLEANOUT PERISPWC SD-506ARIM: 2680.99±IE IN: 2669.80, 4-IN PVC (W)IE OUT: 2669.80, 4-IN PVC (E)SEE L2.04 - AREA 4135°135°135°10'Project Name: Revisions This document and the information contained herein may not be copied or reproduced without express written permission of The Land Group, Inc. Unauthorized disclosure or construction use are prohibited by copyright law.Date of Issuance:Project No.:Designed by:Checked by:Sheet No.:Sheet Title: Firenze Plaza NWC Eagle Road & Amity Road Site Improvement Plans Meridian Idaho1160159.22.2020RC/MTGW/DRHORIZONTAL SCALE: 1" = 20'20'40'0File Location:g:\2016\116015\cad\116015 cd c501 site utility plan.dwgLast Plotted By:gabe welzDate Plotted:Tuesday, September 22 2020 at 04:37 PM C5.04Site Utility Area 4 Sewer And Water PlanSite Utility - Area 4 Sewer and Water PlanAPPROVED FORCONSTRUCTIONNameDateIDAHOThese plans and/or specifications have been reviewed for compliance withMeridian City Standards and Specifications. This review does not relieve theowner, engineer, or contractor of the responsibility to design and/or constructthose facilities in compliance with all current applicable federal, state and locallaws, rules, regulations, ordinances, development agreements, specifications,orders or approvals, all of which the City retains the right to enforce.inconsistencies not noted by City staff shall not be construed as approvedunless specifically addressed in writing by the City. Any proposed revision tothese plans must be submitted for review and compliance with the MeridianCity Standards and Specifications before said revision is constructed.Legend:8''WPROPERTY BOUNDARY LINELOT LINEINGRESS/EGRESS & PUBLIC UTILITY EASEMENTLINE8" WATER MAIN (OR AS NOTED)GATE VALVEFIRE HYDRANT PER CITY OF MERIDIAN DETAILW7BLOW-OFF VALVE PER CITY OF MERIDIANDETAILS W12 OR W13THRUST BLOCKEXISTING WATER MAIN (SIZE NOTED)EXISTING BLOW-OFF ASSEMBLYEXISTING GATE VALVEEXISTING FIRE HYDRANTSEWER MAIN (SIZE NOTED)EXISTING SEWER MAIN (SIZE NOTED)PRESSURE IRRIGATION (SIZE NOTED)EXISTING PRESSURE IRRIGATION (SIZE NOTED)GRAVITY IRRIGATION LINE (SIZE NOTED)EXISTING GRAVITY IRRIGATION LINE (SIZENOTED)WWTR8''SSWTRWTR8''SSPIRRPIRRGIRRGIRRP/LSheet Notes:1.CONTRACTOR SHALL COMPLY WITH ALL NOTES ON SHEETS C1.00.Keynotes:#1.POTABLE WATER MAIN CROSSING - SEE CITY OF MERIDIAN WATER NOTE NO. 2ON SHEET C1.00.2.INSTALL FIRE HYDRANT ASSEMBLY PER CITY OF MERIDIAN SUPPLEMENTALDRAWING SD-W8. INSTALL 1-8"x8"x6" TEE (FLG) WITH 1-6" GATE VALVE(FLGxMJ), 1-8" GATE VALVE (FLGxMJ), AND 1-8" FLGxMJ ADAPTER PER CITY OFMERIDIAN SUPPLEMENTAL DRAWING SD-W11. THRUST BLOCK AS REQUIRED.3.INSTALL 1-8"x8"x8" TEE (MJxMJxFLG) WITH 1-8" GATE VALVE (FLGxMJ) PERCITY OF MERIDIAN SUPPLEMENTAL DRAWING SD-W11. THRUST BLOCK ASREQUIRED.4.INSTALL 2" BLOW OFF ASSEMBLY PER MERIDIAN SUPPLEMENTAL DRAWINGSD-W12.5.INSTALL 45° BEND (MJxMJ). THRUST BLOCK AS REQUIRED.6.CAP AND MARK END PER ISPWC SD-512.MATCH LINE - SEE SHEET C5.03 MATCH LINE - SEE SHEET C5.02SEE C5.06 - SEWER MAIN B PLANSEE C5.05-C5.06 - SEWER MAIN B PLAN09/22/2020 SEWER LINE B: Sta. -0+50 - 4+00HORIZONTAL SCALE: 1" = 20'VERTICAL SCALE: 1" = 2'2661266526702675268026612665267026752680FINISH GRADE AT CENTERLINE OF PIPEEXISTING GROUND AT CENTERLINE OF PIPE-0+500+002675.82675.782675.92675.93 1+002676.5 2676.46 2676.7 2676.78 2+002676.4 2676.0 3+002676.0 2677.56 2676.1 2678.77 4+002676.2 2679.50 EXISTING GROUND ELEV. AT CENTERLINESEWER PIPE SLOPES ARE CALCULATED USING LENGTH OF RUN FROM CENTER - CENTER OF MANHOLEIE OUT: 2666.74, 8-IN PVC (S)SS STRC 2.0148-IN DIA.STA: 0+00, 0.00'RIM: 2675.78±IE IN: 2665.40, 8-IN PVC (N)IE IN: 2665.40, 8-IN PVC (S)IE IN: 2665.74, 4-IN PVC (SE)IE OUT: 2665.30, 8-IN PVC (W)SS STRC 1.0848-IN DIA.STA: 2+23.67, 0.00'RIM: 2677.21±12-IN PVCWATER CROSSING224-LF OF 8-IN PVC AT 0.60%4-IN SERVICESTA: 0+084-IN SERVICESTA: 0+144-IN SERVICESTA: 1+234-IN SERVICESTA: 1+30194-LF OF 8-IN PVC AT 0.40%2FINISH GRADE ELEV. AT CENTERLINE4''S S 4''S S EPEPEPEPEPEP8''SS8''SS8''SS8''SS8''SS8''SS8''SSMTREP 12''W12''W12''W 8''W8''W8''W8''W8''W8''SS8''SS SAN SAN EPEPPAD B FUEL CENTER 8''SS8''SS8''SS8''W8''W8''W8''WEGEGEGEGEGEGEGEGEGEGEGEGEGEGEGEGEGEGEGEGEGEG8''WFUEL CENTER WORK SITE WORK SITE WORKFUEL CENTER WORKPIRRPIRRPIRRPIRRSAN 12''W 13+00 14+000+001+002+003+004+00SS STRC 3.01CITY OF MERIDIAN INGRESS/EGRESS & PUBLIC UTILITY EASEMENT 177.5°E. Mount Etna Dr. 10.8' (10' MIN.) SEE L2.02 - AREA 2SEE C3.14 - E. MOUNT ETNA DR. SEWER PLANSEE C3.15 - ROADWAY WATER PLANSEE C3.15 - ROADWAY WATER PLANSS STRC 2.01SS STRC 1.08224-LF OF 8-IN PVC AT 0.60%20-LF OF 4-IN PVC AT 2% (MIN.)34-LF OF 4-IN PVC AT 2% (MIN.)20-LF OF 4-IN PVC AT 2% (MIN.)34-LF OF 4-IN PVC AT 2% (MIN.)66664-IN PVCIE: 2666.674-IN PVCIE: 2666.634-IN PVCIE: 2667.324-IN PVCIE: 2667.36194-LF OF 8-IN PVC AT 0.40%3233310.511.3'(10' MIN.)164 90°9 0 °113° Project Name: Revisions This document and the information contained herein may not be copied or reproduced without express written permission of The Land Group, Inc. Unauthorized disclosure or construction use are prohibited by copyright law.Date of Issuance:Project No.:Designed by:Checked by:Sheet No.:Sheet Title: Firenze Plaza NWC Eagle Road & Amity Road Site Improvement Plans Meridian Idaho1160159.22.2020RC/MTGW/DRFile Location:g:\2016\116015\cad\116015 cd c501 site utility plan.dwgLast Plotted By:gabe welzDate Plotted:Tuesday, September 22 2020 at 04:37 PM C5.05Site Utility Sewer Main B Plan Sta. 0+00 - Sta. 4+00 HORIZONTAL SCALE: 1" = 20'Sewer Main B Plan20'40'0Sewer Keynotes:#1.NOT USED ON THIS SHEET.2.POTABLE WATER MAIN CROSSING - SEE SEWER NOTE NO. 2/C1.01.3.POTABLE / NON-POTABLE SERVICE CROSSING - SEE SEWER NOTE NO. 3/C1.01.4.CONSTRUCT 16FT WIDE GRAVEL ACCESS ROAD PER MERIDIAN STANDARDDRAWING NO. G-2MATCH LINE - SEE SHEET C5.06SEE C5.02 - AREA 2 SEWER AND WATER PLAN09/22/2020 SEWER LINE B: Sta. 4+00 - 8+50HORIZONTAL SCALE: 1" = 20'VERTICAL SCALE: 1" = 2'26632665267026752680266326652670267526804+002676.22679.502676.42679.615+002676.52679.852676.62680.21 6+002677.3 2680.30 2677.3 2680.34 7+002677.4 2680.36 2677.5 2680.91 8+008+50IE IN: 2666.28, 8-IN PVC (S)IE OUT: 2666.18, 8-IN PVC (N)SS STRC 3.0148-IN DIA.STA: 4+17.60, 0.00'RIM: 2679.49±IE IN: 2668.87, 4-IN PVC (SW)IE IN: 2668.70, 6-IN PVC (S)IE OUT: 2668.53, 8-IN PVC (N)SS STRC 3.0248-IN DIA.STA: 7+93.39, 0.00'RIM: 2681.05±SEWER PIPE SLOPES ARE CALCULATED USING LENGTH OF RUN FROM CENTER - CENTER OF MANHOLE376-LF OF 8-IN PVC AT 0.60%4-IN SERVICESTA: 6+044-IN SERVICESTA: 7+42EXISTING GROUND ELEV. AT CENTERLINEFINISH GRADE ELEV. AT CENTERLINEFINISH GRADE AT CENTERLINE OF PIPEEXISTING GROUND AT CENTERLINE OF PIPEEPEPEP6''SS 8''W8''W8''W8''W8''W8''W8''W8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SSSAN SAN EPEPEP EP EP EP EPEPEPEPEPEPEPEPEPEPEPEPEPEPEPPAD C BANK PAD D RESTAURANT PAD E RESTAURANT EP8''SSSITE WORKFUEL CENTER WORKSITE WORKFUEL CENTER WORKEPEP EP EP EP EPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEP EP EP4+005+006+007+00SS STRC 3.02SS STRC 3.0126-LF OF 6-IN PVC AT 2% MIN.CITY OF MERIDIANINGRESS/EGRESS &PUBLIC UTILITYEASEMENT177.5°10.8'(10' MIN.)24-LF OF 4-IN PVC AT 2.00%SS STRC 3.034" CLEANOUT PERISPWC SD-506ARIM: 2681.00±IE IN: 2669.34, 4-IN PVC (W)IE OUT: 2669.34, 4-IN PVC (NE)27-LF OF 6-IN PVC AT 2% (MIN.)6-IN PVCIE: 2674.5025-LF OF 4-IN PVC AT 2% (MIN.)4-IN PVCIE: 2674.00222135°63.1°161.9°26-IN PVCIE: 2674.00666135°135°11'(10' MIN.)376-LF OF 8-IN PVC AT 0.60%Project Name: Revisions This document and the information contained herein may not be copied or reproduced without express written permission of The Land Group, Inc. Unauthorized disclosure or construction use are prohibited by copyright law.Date of Issuance:Project No.:Designed by:Checked by:Sheet No.:Sheet Title: Firenze Plaza NWC Eagle Road & Amity Road Site Improvement Plans Meridian Idaho1160159.22.2020RC/MTGW/DRFile Location:g:\2016\116015\cad\116015 cd c501 site utility plan.dwgLast Plotted By:gabe welzDate Plotted:Tuesday, September 22 2020 at 04:37 PM C5.06Site Utility Sewer Main B Plan Sta. 4+00 - Sta. 8+50 HORIZONTAL SCALE: 1" = 20'Sewer Main B Plan20'40'0Sewer Keynotes:#1.NOT USED ON THIS SHEET.2.POTABLE WATER MAIN CROSSING - SEE SEWER NOTE NO. 2/C1.01.3.POTABLE / NON-POTABLE SERVICE CROSSING - SEE SEWER NOTE NO. 3/C1.01.MATCH LINE - SEE SHEET C5.05 SEE C5.04 - AREA 4SEWER AND WATER PLANSEE C5.04 - AREA 4 SEWER AND WATER PLAN09/22/2020