Life Safety PlanLIFE SAFETY LEGEND XX"36"# EXIT LOAD EXIT WIDTH PROVIDED EXIT WIDTH REQUIRED # SF # # ROOM NAME ROOM # A-1 SQUARE FOOTAGE OF ROOM USE GROUP / LOAD FACTOR OCCUPANT LOAD OF ROOM EGRESS PATH XX'INDICATES DISTANCE OF TRAVEL INDICATES MOST REMOTE LOCATION FROM EXIT EXIT SIGN, REFER TO ELECTRICAL FIRE EXTINGUISHER BRACKET (FEB) OCCUPANT EGRESS AT DOOR/STAIR TAG OCCUPANT LOAD ROOM TAG 1 B A 2 71' 91.8 36"102"76"28' 10 2"36" 88' 36 SF 1 300 STORAGE CLOSET 102 H-4 1698 SF 17 100 PUMP ROOM 101 H-4 405 SF 2 300 CHLORINE ROOM 103 H-4 299 SF ELECTRICAL ROOM 104 54 SF 1 300 FIRE ROOM 106 H-498 SF 1 300 BLOWER ROOM 105 H-4 M AX. O VERALL DIA G O NAL 78' - 5"SEPARATION DISTANCE > 1/3 33' - 9" FIRE RATED WALLS LEGEND 2 HOUR RATED WALL THIS DRAWING WAS PREPARED BY POWER ARCHITECTURAL CONSULTANTS, INC. FOR A SPECIFIC PROJECT. TAKING INTO CONSIDERATION THE SPECIFIC AND UNIQUE REQUIRMENTS OF THE PROJECT. REUSE OF THIS DRAWING OR ANY INFORMATION CONTAINED IN THIS DRAWING FOR ANY PURPOSE IS PROHIBITED UNLESS WRITTEN PERMISSION FROM BOTH POWER AND POWER'S CLIENT IS GRANTED. DRAWING NO. BAR IS ONE INCH ON FULL SIZE DRAWING 0 1" IDAHO OFFICES BOISE · LEWISTON · MCCALL ENGINEERING AND ENVIRONMENTAL SOLUTIONS 1161 W RIVER ST, STE 130 BOISE, IDAHO 83702 208.780.3990 DATE PROJECT VERIFY SCALENO.REVISION BY DATE DESIGN DRAWN CHECKED APPROVED 10/22/20 TOW1/27/2021 11:20:28 AMA1.0 CITY OF MERIDIAN LIFE SAFETY PLAN 167064 YM BJT SJB WELL 17 TREATMENT FACILITY 0'2' 4' 8' 1/4" = 1'-0"1/4" = 1'-0" LIFE SAFETY PLAN1 LIFE SAFETY PLAN NOTES 1. ALL EXITS SHALL HAVE EXIT SIGNS AND ALL BLIND CORRIDOR TURNS SHALL HAVE DIRECTIONAL EXIT SIGNS. 2. CHANGE OF LEVEL AT ALL EXITS AND ENTRANCES SHALL NOT EXCEED 1/2". NOTIFY ARCHITECT OF ANY DISCREPANCIES. FIRE EXTINGUISHER NOTES 1. LOCATIONS AND CLASSIFICATIONS OF FIRE EXTINGUISHERS SHALL BE IN ACCORDANCE WITH STATE & LOCAL FIRE CODE AND IS SUBJECT TO THE APPROVAL OF THE AHJ. 2. EXACT LOCATION AND QUANTITY OF FIRE EXTINGUISHER CABINETS/BRACKETS TO BE CONFIRMED PRIOR TO INSTALLATION. 3. ALL PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED AND INSTALLED BY CONTRACTOR BASED ON THE FOLLOWING CRITERIA: A. FIRE EXTINGUISHER TYPE (FE-1): 4-A:80-B:C APPLICABLE PROJECT AREA: INDUSTRIAL AREAS CLASSIFICATION OF HAZARDS: EXTRA (HIGH) HAZARD OCCUPANCY MAXIMUM AREA TO BE PROTECTED PER EXTINGUISHER: 11,250 SQ. FT. MAXIMUM DISTANCE TRAVELED: 75 FEET 4. FIRE EXTINGUISHERS MOUNTED IN UNHEATED AREAS SHALL BE RATED FOR ANTICIPATED TEMPERATURES TRUE NORTH PLANT NORTHNORTH PRELIMINARY NOT FOR CONSTRUCTION A ISSUED FOR 60% REVIEW BJT 11/10/20 B ISSUED FOR 90% REVIEW BJT 01/27/21