Floor PlanFLOOR PLAN LEGEND ##DOOR TYPE TAG WALL TYPE TAG KEYED NOTE TAG NEW ASSEMBLIES/SYSTEMS N# ? ROOM NAME ### ROOM TAG WITH NUMBER #.# A A2.0 B A2.0 B A2.1 A A2.1 1 B A 2 10"41' - 9"8" 13' - 4" 8"43' - 4"65' - 4" 20' - 6"6' - 8" 7' - 2" 8"3' - 4"1' - 4"8"1' - 0"5' - 4"7' - 8"8"1' - 8"3' - 4"14' - 0"8' - 2"9' - 2" 3' - 4" 6' - 6" 8" 14' - 1"8"1' - 6"10' - 0" 3' - 4" 101C 103C 103A 104A 105A 101A 103B PUMP ROOM 101 CHLORINE ROOM 103 STORAGE CLOSET 102 ELECTRICAL ROOM 104 FIRE ROOM 106BLOWER ROOM 105 3' - 4"102A 8' - 10"7' - 6" 8" 2' - 0" 3' - 4" 2' - 0"5' - 4"20' - 0"2' - 0"3' - 4"5' - 10"8"6' - 2"101B N1 N1 N1 N2 N2 N2 N2 N2 N2 N2 N2 106A 03.0403.04 03.04 11.0111.02 17.04 03.0103.01 03.01 03.01 05.0205.02 05.02 05.02 10.02 10.02 17.02 17.02 17.02 03.05 03.01 11.03 16.0216.02 16.02 16.02 16.02 16.02 16.02 16.02 16.02 16.02 16.02 A3.1 2 A3.1 1 A3.1 FIRE RATED WALLS LEGEND 2 HOUR RATED WALL THIS DRAWING WAS PREPARED BY POWER ARCHITECTURAL CONSULTANTS, INC. FOR A SPECIFIC PROJECT. TAKING INTO CONSIDERATION THE SPECIFIC AND UNIQUE REQUIRMENTS OF THE PROJECT. REUSE OF THIS DRAWING OR ANY INFORMATION CONTAINED IN THIS DRAWING FOR ANY PURPOSE IS PROHIBITED UNLESS WRITTEN PERMISSION FROM BOTH POWER AND POWER'S CLIENT IS GRANTED. DRAWING NO. BAR IS ONE INCH ON FULL SIZE DRAWING 0 1" IDAHO OFFICES BOISE · LEWISTON · MCCALL ENGINEERING AND ENVIRONMENTAL SOLUTIONS 1161 W RIVER ST, STE 130 BOISE, IDAHO 83702 208.780.3990 DATE PROJECT VERIFY SCALENO.REVISION BY DATE DESIGN DRAWN CHECKED APPROVED 10/22/20 TOW1/27/2021 11:20:30 AMA1.1 CITY OF MERIDIAN FLOOR PLAN 167064 YM BJT SJB WELL 17 TREATMENT FACILITY FLOOR PLAN NOTES 1. UNLESS NOTED OTHERWISE OR INDICATED, ALL DIMENSIONS SHALL BE TO THE FACE OF STUD OR FINISH FACE OF CONCRETE OR MASONRY. 2. CONTRACTOR TO PREP ALL CMU AND CONCRETE SURFACES SCHEDULED TO RECEIVE NEW COATINGS. 3. DOOR OPENINGS NOT DIMENSIONED ARE TO BE LOCATED WITHIN 4" OF ADJACENT PERPENDICULAR PARTITION. 4. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 5. FIXTURES AND ELEMENTS IN PROJECT HAVE BEEN DESIGNED TO BE ACCESSIBLE. REFER TO STANDARD ACCESSIBILITY DETAILS. 6. WHERE THERE IS AN ACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING OR ATTIC SPACE, FIRE WALLS, FIRE-BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING IN THE CONCEALED SPACE. SUCH IDENTIFICATION SHALL: A. BE LOCATED WITHIN 15 FEET OF THE END OF EACH WALL AND AT INTERVALS NOT EXCEEDING 30 FEET MEASURED HORIZONTALLY ALONG THE WALL OR PARTITION. B. INCLUDE LETTERING NOT LESS THAN 3 INCHES IN HEIGHT WITH A MINIMUM 3/8 INCH STROKE IN A CONTRASTING COLOR INCORPORATING THE SUGGESTED WORDING, "FIRE AND/OR SMOKE BARRIER-PROTECT ALL OPENINGS," OR OTHER WORDING. 7. PROVIDE UL LISTED FIRE STOP SYSTEMS AT FIRE-RATED ASSEMBLY PENETRATIONS 0'2' 4' 8' 1/4" = 1'-0"1/4" = 1'-0" FLOOR PLAN1 TRUE NORTH PLANT NORTHNORTH KEYED NOTES # NOTE 03.01 NEW 6" SLAB ON GRADE, REFER TO STRUCTURAL. 03.04 EQUIPMENT PADS, REFER TO STRUCTURAL. 03.05 PLATFORM, REFER TO STRUCTURAL. 05.02 PRE-FINISHED ALUMINUM SEAMLESS GUTTERS AND DOWNSPOUTS COLOR TO MATCH FASCIA TRIM COLOR. 10.02 6" BOLLARD, REFER TO STRUCTURAL. 11.01 EYEWASH STATION, REFER TO MECHANICAL. 11.02 PREFABRICATED STAINLESS STEEL BENCH WITH SINK, REFER TO MECHANICAL. 11.03 CHLORINE TANK. 16.02 ELECTRICAL EQUIPMENT, REFER TO ELECTRICAL. 17.02 MECHANICAL EQUIPMENT, REFER TO MECHANICAL. 17.04 BLOWER, REFER TO MECHANICAL. PRELIMINARY NOT FOR CONSTRUCTION A ISSUED FOR 30% REVIEW BJT 10/22/20 B ISSUED FOR 60% REVIEW BJT 11/10/20 C ISSUED FOR 90% REVIEW BJT 01/27/21