Exterior Building Elevations 1FIRST FLOOR
100' - 0"
TOP OF WALL
115' - 4"
1
ROOF
123' - 9 1/2"
2
CANOPY HEIGHT
110' - 0"
TOP OF STEM WALL
102' - 0"
05.01
03.02
10.01 10.01
10.02
05.02
17.03
17.02
17.02
17.02
03.0103.01
17.0317.0317.03
04.02
03.07 03.07
03.06
04.02
FIRST FLOOR
100' - 0"
TOP OF WALL
115' - 4"
1
ROOF
123' - 9 1/2"
2
CANOPY HEIGHT
110' - 0"
TOP OF STEM WALL
102' - 0"
04.01
08.03
08.02
05.01
05.02 05.02
10.02
10.01
10.0108.01 08.01 08.01
03.02
17.03
17.02
17.02
17.02
03.01 03.01
17.0317.0317.03
04.0204.02
26.01
26.0103.07 03.07
03.08 03.08 03.08
01.01
EXTERIOR ELEVATION LEGEND
?KEYED NOTE TAG#.#
BASALITE -995 PRECISION
BASALITE - 695 GROUND FACE
BASALITE -640 SPLIT FACE
THIS DRAWING WAS PREPARED BY POWER
ARCHITECTURAL CONSULTANTS, INC. FOR A
SPECIFIC PROJECT. TAKING INTO CONSIDERATION
THE SPECIFIC AND UNIQUE REQUIRMENTS OF THE
PROJECT. REUSE OF THIS DRAWING OR ANY
INFORMATION CONTAINED IN THIS DRAWING FOR
ANY PURPOSE IS PROHIBITED UNLESS WRITTEN
PERMISSION FROM BOTH POWER AND POWER'S
CLIENT IS GRANTED.
DRAWING NO.
BAR IS ONE INCH ON
FULL SIZE DRAWING
0 1"
IDAHO OFFICES
BOISE · LEWISTON · MCCALL
ENGINEERING AND ENVIRONMENTAL SOLUTIONS
1161 W RIVER ST, STE 130
BOISE, IDAHO 83702
208.780.3990 DATE
PROJECT
VERIFY SCALENO.REVISION BY DATE DESIGN
DRAWN
CHECKED
APPROVED
10/22/20
TOW1/27/2021 11:20:34 AMA2.0
CITY OF MERIDIAN
EXTERIOR BUILDING ELEVATIONS
167064
YM
BJT
SJB
WELL 17 TREATMENT FACILITY
0'2' 4' 8'
1/4" = 1'-0"1/4" = 1'-0"
WEST ELEVATIONA
0'2' 4' 8'
1/4" = 1'-0"1/4" = 1'-0"
EAST ELEVATIONB
KEYED NOTES
# NOTE
01.01 ROOF ACCESS HATCH, SEE DETAIL 5 / A8.2
03.01 NEW 6" SLAB ON GRADE, REFER TO STRUCTURAL.
03.02 2' STEM WALL, REFER TO STRUCTURAL.
03.06 10"x8"x16" CMU, BASALITE 695 - GROUND FACE
03.07 10"x8"x16" CMU, BASALITE 640 - SPLIT FACE
03.08 10"x8"x8"CMU, BASALITE 995 - PRECISION
04.01 10"x8"x16" SPLIT FACE CMU, REFER TO STRUCTURAL.
04.02 CONTROL JOINT, REFER TO STRUCTURAL.
05.01 STANDING SEAM METAL ROOF, DARK GREEN COLOR.
05.02 PRE-FINISHED ALUMINUM SEAMLESS GUTTERS AND
DOWNSPOUTS COLOR TO MATCH FASCIA TRIM
COLOR.
08.01 GLASS BLOCK WINDOW, REFER TO STRUCTURAL.
08.02 INSULATED ROLL-UP DOOR. GRAY PAINT, FINISH
SURFACES PER MANUFACTURER'S SPECIFICATIONS.
08.03 INSULATED METAL DOOR. GRAY PAINT, FINISH
SURFACES PER MANUFACTURER'S SPECIFICATIONS.
10.01 PAINTED STEEL CANOPY, REFER TO STRUCTURAL.
10.02 6" BOLLARD, REFER TO STRUCTURAL.
17.02 MECHANICAL EQUIPMENT, REFER TO MECHANICAL.
17.03 SOLATUBE 750-DS SKYLIGHT OR APPROVED EQUAL.
26.01 LIGHT FIXTURE, REFER TO ELECTRICAL.
PRELIMINARY
NOT FOR
CONSTRUCTION
EXTERIOR FINISH COLOR
1. -HI-R CMU BLOCK & STANDARD CMU COLOR: DESERT
SAND (MATCH EXISTING WELL 28 BUILDING)
2. -MORTAR COLOR TO MATCH BLOCK COLOR.
3. -CMU BLOCK SEALANT: CLEAR
4. -STANDING SEAM METAL ROOFING COLOR: DARK GREEN
(MATCH EXISTING WELL 28 BUILDING)
5. -GUTTER/DOWNSPOUT: COLOR TO MATCH TRIM COLOR.
6. -EXTERIOR DOOR FRAMES: GREY (MATCH EXISTING WELL
28 BUILDING)
7. -EXTERIOR DOORS: GREY (MATCH EXISTING WELL 28
BUILDING)
8. -OVERHEAD DOOR: MFR APPLIED PREMIUM POWDER
COAT (MATCH EXISTING WELL 28 BUILDING)
9. -HARDIE BOARD SIDING AND TRIM (MATCH EXISTING
WELL 28 BUILDING)
10. -PIPE BOLLARDS: SAFETY YELLOW SW 4084 - (2) COATS
(SHERWIN WILLIAMS)
11. -CANOPIES: PRIMED AND PAINTED STEEL FRAMING AND
STEEL DECK (MATCH EXISTING WELL 28 BUILDING)
A ISSUED FOR 30% REVIEW BJT 10/22/20
B ISSUED FOR 60% REVIEW BJT 11/10/20
C ISSUED FOR 90% REVIEW BJT 01/27/21