Loading...
Cover SheetTHIS DRAWING WAS PREPARED BY POWER ARCHITECTURAL CONSULTANTS, INC. FOR A SPECIFIC PROJECT. TAKING INTO CONSIDERATION THE SPECIFIC AND UNIQUE REQUIRMENTS OF THE PROJECT. REUSE OF THIS DRAWING OR ANY INFORMATION CONTAINED IN THIS DRAWING FOR ANY PURPOSE IS PROHIBITED UNLESS WRITTEN PERMISSION FROM BOTH POWER AND POWER'S CLIENT IS GRANTED. DRAWING NO. BAR IS ONE INCH ON FULL SIZE DRAWING 0 1" IDAHO OFFICES BOISE · LEWISTON · MCCALL ENGINEERING AND ENVIRONMENTAL SOLUTIONS 1161 W RIVER ST, STE 130 BOISE, IDAHO 83702 208.780.3990 DATE PROJECT VERIFY SCALENO.REVISION BY DATE DESIGN DRAWN CHECKED APPROVED 10/22/20 TOW1/27/2021 11:20:24 AMA0.0 CITY OF MERIDIAN COVER SHEET / DRAWING INDEX / CODE ANALYSIS 167064 YM BJT SJB WELL 17 TREATMENT FACILITY POWER A/E CONSULTING 2041 SOUTH COBALT POINT WAY MERIDIAN, ID 83642 ARCHITECT OF RECORD: SAM BORMAN 208-288-6868 CONTACT: SAM BORMAN 208-288-6868 ARCHITECT POWER ENGINEERS, INC. 2041 SOUTH COBALT POINT WAY MERIDIAN, ID 83642 ENGINEER OF RECORD: TREVOR WHITE 208-288-6762 CONTACT: TREVOR WHITE 208-288-6762 POWER ENGINEERS, INC. 2041 SOUTH COBALT POINT WAY MERIDIAN, ID 83642 ENGINEER OF RECORD: JAYSON SCHWENDIG 208-288-6216 CONTACT: SAGE THIBODEAU 608-826-7915 STRUCTURAL ENGINEER MECHANICAL ENGINEER BOWEN COLLINS & ASSOCIATES 776 EAST RIVERSIDE DRIVE STE. 250 EAGLE, ID 83616 ENGINEER OF RECORD: DARIN YOUNGSTROM 208-939-9561 CONTACT: DARIN YOUNGSTROM 208-939-9561 ELECTRICAL ENGINEER CITY OF MERIDIAN 33 EAST BROADWAY AVENUE MERIDIAN, ID 83642 OWNER MOUNTAIN WATERWORKS 1161 WEST RIVER STREET STE. 130 BOISE, ID 83702 CONTACT: STUART HURLEY 208-780-3994 CIVIL ENGINEER DRAWING INDEX SHEET ORGANIZATION # SHEET NAME REV. DATE 01-GENERAL A0.0 COVER SHEET / DRAWING INDEX / CODE ANALYSIS C 01/27/21 02-ARCHITECTURAL A0.1 ARCHITECTURAL ABBREVIATIONS AND SYMBOLS B 01/27/21 02-ARCHITECTURAL A0.2 COMCHECK A 01/27/21 02-ARCHITECTURAL A0.3 WALL TYPES & FINISHES A 01/27/21 02-ARCHITECTURAL A1.0 LIFE SAFETY PLAN B 01/27/21 02-ARCHITECTURAL A1.1 FLOOR PLAN C 01/27/21 02-ARCHITECTURAL A1.2 ROOF PLAN B 01/27/21 02-ARCHITECTURAL A2.0 EXTERIOR BUILDING ELEVATIONS C 01/27/21 02-ARCHITECTURAL A2.1 EXTERIOR BUILDING ELEVATIONS C 01/27/21 02-ARCHITECTURAL A3.1 WALL SECTIONS A 01/27/21 02-ARCHITECTURAL A7.0 DOOR SCHEDULE AND TYPES A 01/27/21 02-ARCHITECTURAL A8.1 DETAILS B 01/27/21 02-ARCHITECTURAL A8.2 DETAILS A 01/27/21 03-STRUCTURAL S0.01 GENERAL STRUCTURAL NOTES B 01/27/21 03-STRUCTURAL S0.02 GENERAL STRUCTURAL NOTES B 01/27/21 03-STRUCTURAL S0.03 GENERAL STRUCTURAL NOTES AND SPECIAL INSPECTION SCHEDULES B 01/27/21 03-STRUCTURAL S0.04 SPECIAL INSPECTION SCHEDULES B 01/27/21 03-STRUCTURAL S1.01 FOUNDATION PLAN B 01/27/21 03-STRUCTURAL S1.11 CONCRETE FLOOR SLAB PLAN B 01/27/21 03-STRUCTURAL S1.21 PLATFORM FRAMING PLAN AND DETAILS A 01/27/21 03-STRUCTURAL S2.01 ROOF FRAMING PLAN B 01/27/21 03-STRUCTURAL S3.01 CMU WALL ELEVATIONS B 01/27/21 03-STRUCTURAL S3.02 CMU WALL ELEVATIONS B 01/27/21 03-STRUCTURAL S4.01 TYPICAL CONCRETE DETAILS B 01/27/21 03-STRUCTURAL S4.02 FOUNDATION DETAILS B 01/27/21 03-STRUCTURAL S4.03 CONCRETE DETAILS B 01/27/21 03-STRUCTURAL S4.04 CONCRETE DETAILS B 01/27/21 03-STRUCTURAL S5.01 ROOF FRAMING DETAILS B 01/27/21 03-STRUCTURAL S7.01 TYPICAL CMU DETAILS B 01/27/21 04-FIRE PROTECTION F2.11 FIRE PROTECTION FLOOR PLAN B 01/27/21 04-FIRE PROTECTION F6.01 FIRE PROTECTION DETAILS B 01/27/21 05-MECHANICAL H0.01 HVAC SYMBOLS, ABBREVIATIONS AND GENERAL NOTES B 01/27/21 05-MECHANICAL H0.02 HVAC SCHEDULES B 01/27/21 05-MECHANICAL H0.03 HVAC SPECIFICATIONS B 01/27/21 05-MECHANICAL H2.11 HVAC FLOOR PLAN B 01/27/21 05-MECHANICAL H6.01 HVAC DETAILS B 01/27/21 06-PLUMBING P0.01 PLUMBING SYMBOLS, ABBREVIATIONS AND GENERAL NOTES B 01/27/21 06-PLUMBING P0.02 PLUMBING SCHEDULES B 01/27/21 06-PLUMBING P0.03 PLUMBING SPECIFICATIONS B 01/27/21 06-PLUMBING P2.01 PLUMBING UNDERFLOOR PLAN B 01/27/21 06-PLUMBING P2.11 PLUMBING FLOOR PLAN B 01/27/21 06-PLUMBING P6.01 PLUMBING DETAILS B 01/27/21 1017.2 (H-4) HIGH - HAZARD GROUP 175 FT MAX TRAVEL DISTANCE WITH SPRINKLER SYSTEM EXITS PROVIDED 3 1006.3.1 EXITS REQUIRED (29) OCC 2 PROPOSED MAX 84' B / F / S OCCUPANCIES WITH SPRINKLER SYSTEM 75' MAX 1006.2.1 COMMON PATH OF EGRESS TRAVEL TOTAL EXIT WIDTH PROVIDED 96 1005.2 EXIT WIDTH DOORS .2 x (29) OCCUPANTS TOTAL EXIT WIDTH REQUIRED 58 EXITING: TOTAL OCCUPANT LOAD 29 INDUSTRIAL AREAS 2,831 100 GROSS 29 1004 TOTAL AREA AREA / OCC OCC LOAD OCCUPANT LOAD: 903 FIRE SPRINKLER SYSTEM (NEW) NFPA 13 ROOF CONSTRUCTION 0 HRS FLOOR CONSTRUCTION 0 HRS NON-BEARING WALLS 0 HRS BEARING WALLS - INTERIOR 0 HRS BEARING WALLS - EXTERIOR 2 HRS PRIMARY STRUCTURAL FRAME 0 HRS 601 FIRE RESISTIVE CONSTRUCTION RATING 0 HRS 602 CONSTRUCTION TYPE III-B PROPOSED NUMBER OF STORES 1 504.4 ALLOWABLE NUMBER OF STORIES 4 PROPOSED BUILDING HEIGHT 23' - 9 3/4" 504.3 ALLOWABLE HEIGHT IN FEET 55' PROPOSED BUILDING AREA 2,831 SF 506.2 ALLOWABLE BUILDING AREA 70,000 SF BUILDING SIZE AND AREA: 307.6 (H-4) HIGH-HAZARD GROUP BUILDING OCCUPANCY: 2017 NATIONAL ELECTRICAL CODE (NEC) 2018 INTERNATIONAL ENERGY CONSERVATION CODE (IECC), WITH AMMENDMENTS 2017 IDAHO (UNIFORM) STATE PLUMBING CODE (ISPC) 2018 INTERNATIONAL MECHANICAL CODE (IMC), WITH AMENDMENTS 2018 IDAHO FIRE CODE (IFC), WITH AMENDMENTS 2018 INTERNATIONAL FUEL & GAS CODE (IFGC), WITH AMENDMENTS 2018 INTERNATIONAL BUILDING CODE (IBC), WITH AMENDMENTS APPLICABLE CODES: (WITH LOCAL AMENDMENTS) MERIDIAN, ID 83642 1616 EAST TIME ZONE DRIVE PROJECT ADDRESS: PROJECT INFORMATION: A NEW WATER TREATMENT FACILITY AT EXISTING CITY OF MERIDIAN WELL 17 SITE. THE NEW BUILDNG WILL HOUSE THE WELL AND WATER TREATMENT VESSELS. THE BUILDING WILL HAVE A SEPARATE ELECTRICAL ROOM, FIRE RISER, AND CHEMICAL CONTAINMENT. PROJECT DESCRIPTION: CODE ANALYSIS (2018 IBC) PROJECT GENERAL NOTES 1. -HI-R CMU BLOCK & STANDARD CMU COLOR: DESERT SAND (MATCH EXISTING WELL 28 BUILDING) 2. -MORTAR COLOR TO MATCH BLOCK COLOR. 3. -CMU BLOCK SEALANT: CLEAR 4. -STANDING SEAM METAL ROOFING COLOR: DARK GREEN (MATCH EXISTING WELL 28 BUILDING) 5. -GUTTER/DOWNSPOUT: COLOR TO MATCH TRIM COLOR. 6. -EXTERIOR DOOR FRAMES: GREY (MATCH EXISTING WELL 28 BUILDING) 7. -EXTERIOR DOORS: GREY (MATCH EXISTING WELL 28 BUILDING) 8. -OVERHEAD DOOR: MFR APPLIED PREMIUM POWDER COAT (MATCH EXISTING WELL 28 BUILDING) 9. -HARDIE BOARD SIDING AND TRIM (MATCH EXISTING WELL 28 BUILDING) 10. -PIPE BOLLARDS: SAFETY YELLOW SW 4084 - (2) COATS (SHERWIN WILLIAMS) 11. -CANOPIES: PRIMED AND PAINTED STEEL FRAMING AND STEEL DECK (MATCH EXISTING WELL 28 BUILDING) 12. CONTRACTOR MUST HAVE THE LOCATIONS OF UNDERGROUND UTILITIES IDENTIFIED AND MARKED PRIOR TO COMMENCING ANY EXCAVATION. 13. ANY DISCREPANCIES BETWEEN DRAWINGS, SPECIFICATIONS, AND/OR EXISTING BUILDING CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR RESOLUTION PRIOR TO PROCEEDING WITH THE WORK, ORDERING MATERIALS, OR FABRICATION. 14. DRAWINGS SHALL NOT BE SCALED FOR DIMENSIONS. WRITTEN DIMENSIONS GOVERN. 15. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND COORDINATE ALL DRAWINGS AND DIMENSIONS; DATUMS; LEVEL; SIZE AND LOCATION OF ALL OPENINGS AND ROUGH OUTS FOR DUCTS, PIPES, CONDUITS, CABINETS AND EQUIPMENT; AND COORDINATE SAME WITH ALL TRADES PRIOR TO PROCEEDING WITH ANY WORK OR FABRICATION. 16. IF DIMENSIONS ARE IN QUESTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE ARCHITECT BEFORE CONTINUING CONSTRUCTION. 17. DIMENSIONS NOTED AS “CLEAR” SHALL BE MAINTAINED AND SHALL ALLOW FOR THE THICKNESS OF ALL FINISHES. UNHEATED SLABS R-10 FOR 24" BELOW (TABLE C402.1.3) FIXED GLAZING: U-0.38 (TABLE C402.4) ROLL-UP DOORS (NONSWINGING): R-4.75 (TABLE C402.1.3) SWINGING DOORS: U-0.37 (TABLE C402.1.4) EXTERIOR WALLS: MASS U-0.090(TABLE C402.1.4) ROOF:ATTIC AND OTHER U-0.027 (TABLE C402.1.4) OR R-38 C.I. (TABLE C402.1.3) NEW EXTERIOR ELEMENTS ONLY SHALL COMPLY WITH THE FOLLOWING MINIMUM REQUIREMENTS: CLIMATE ZONE (C301.1):5B - ADA COUNTY ENVELOPE COM-CHECK REPORT PROVIDED ON SHEET A0.2 PRESCRIPTIVE ENVELOPE ENERGY REQUIREMENTS (2018 IECC) CITY OF MERIDIAN WELL 17 TREATMENT FACILITY 1616 EAST TIME ZONE DRIVE MERIDIAN, ID 83642 VICINITY MAP (NTS) PRELIMINARY NOT FOR CONSTRUCTION A ISSUED FOR 30% REVIEW BJT 10/22/20 B ISSUED FOR 60% REVIEW BJT 11/10/20 C ISSUED FOR 90% REVIEW BJT 01/27/21