Loading...
SITE PLAN AND DETAILSKIDDIE POOL N. JARBIDGE AVE.KIDDIE POOL GENERAL NOTES SITE PLAN: A. BEFORE PROCEEDING TO LAY OUT THE WORK, VERIFY LAYOUT INFORMATION SHOWN ON DRAWINGS, IN RELATION TO THE PROPERTY SURVEY AND EXISTING BENCHMARKS. IF DISCREPANCIES ARE DISCOVERED, NOTIFY ARCHITECT PROMPTLY. B. ENGAGE A LAND SURVEYOR OR PROFESSIONAL ENGINEER TO LAY OUT THE WORK USING ACCEPTED SURVEYING PRACTICES. C. ESTABLISH BENCHMARKS AND CONTROL POINTS TO SET LINES AND LEVELS AT EACH STORY OF CONSTRUCTION AND ELSEWHERE AS NEEDED TO LOCATE EACH ELEMENT OF PROJECT. D. ESTABLISH LIMITS ON USE OF PROJECT SITE. IF STAGING AREA IS NOT DESIGNATED ON PLANS, THEN COORDINATE LOCATION W ITH OWNER. E. ESTABLISH DIMENSIONS WITHIN TOLERANCES INDICATED. DO NOT SCALE DRAWINGS TO OBTAIN REQUIRED DIMENSIONS. F. INFORM SUBCONTRACTORS OF LINES AND LEVELS TO WHICH THEY MUST COMPLY. G. CHECK THE LOCATION, LEVEL AND PLUMB, OF EVERY MAJOR ELEMENT AS THE WORK PROGRESSES. H. LOCATE AND LAY OUT CONTROL LINES AND LEVELS FOR STRUCTURES, BUILDING FOUNDATIONS, COLUMN GRIDS, AND FLOOR LEVELS, INCLUDING THOSE REQUIRED FOR MECHANICAL AND ELECTRICAL WORK. TRANSFER SURVEY MARKINGS AND ELEVATIONS FOR USE WITH CONTROL LINES AND LEVELS. LEVEL FOUNDATIONS AND PIERS FROM TWO OR MORE LOCATIONS. I. STAKING OF THE BUILDING REQUIRES THE GENERAL CONTRACTOR AND THE SURVEYOR TO VERIFY ALL DIMENSIONS COMPLETELY IN BOTH DIRECTIONS TO INSURE THE BUILDING IS PROPERLY LOCATED ON THE SITE. NOTIFY THE ARCHITECT AND THE CIVIL ENGINEER USED ON THIS PROJECT IF THE DIMENSIONS DO NOT CLOSE. J. IF STAKING IS DONE BY A FIRM OTHER THAN THE CIVIL ENGINEER USED ON THIS PROJECT, THE CONTRACTOR IS FULLY RESPONSIBLE FOR ALL SITE DIMENSIONS. K. POOL CONSTRUCTION AND FENCE CONSTRUCTION TO BE DESIGN- BUILD BY GENERAL CONTRACTOR. SUBMIT NECESSARY DOCUMENTATION FOR PERMITTING PER CITY OF NAMPA A1.1 7 A1.1 2 6 A1.1A1.1 8 N. JARBRIDGE AVE.PREFINISHED METAL DOWNSPOUTS PER ROOF PLAN, TYP. 5'-0" WROUGHT IRON FENCE SURROUNDING POOL DECK. SEE LANDSCAPE PLAN.70' - 11"84' - 0"15' - 11"BICYCLE RACK -SEE 9/A1.0. A1.1 9 R 7'R 7'25' - 6"118' - 2" 44' - 0" SITE DATA: PARKING SHOWN: 7 TOTAL STALLS INCLUDING 1 ACCESSIBLE STALL PARKING REQUIRED:1:500 S.F. 2 STALLS REQUIRED ZONING: R-8 SETBACKS: LOCAL - 10' COLLECTOR - 25' ALLEY - 5' INTERIOR SIDE - 5' REAR - 12' BUILDING AREA: 500 S.F. SITE COVERAGE: 6,500 S.F. POOL, DECK, AND BLDG. PAVED AREA / SIDE WALKS: 16,500 S.F. LANDSCAPED AREA: 97,000 SF HANDICAP ACCESSIBILITY SIGN. A1.1 3 20' - 0"3' - 0"3' - 0"3' - 0"3' - 0"5"1' - 1"5"3"4"2"4 "1' - 3" 3" WIDE PAINTED STRIPES (2) COATS WHITE BEDDED REFLECTIVE PAINT BACKGROUND PAINT (2) COATS BLUE PAINT STRIPING WHERE OCCURS CONCRETE CURB AT DIAGONAL PARKING WHERE OCCURS. 4" WIDE STRIPING, PAINT (2) COATS TRAFFIC YELLOW ALIGN WITH END OF STALL STRIPING 96" MIN.9' - 0" VAN ACCESSIBLE RESERVED PARKING 1' - 0"1' - 6"5' - 0"3' - 0"6"1' - 6" 1'-0" x 1'-6" x .080 ALUMINUM ACCESSIBLE PARKING SIGN. SIGN TO READ "RESERVED PARKING" WITH IDENTIFICATION SYMBOL AND "VAN ACCESSIBLE" WHERE APPLICABLE. BOLT TO STEEL TUBE WITH 1/2" CADMIUM PLATED BOLTS, NUTS, AND WASHERS. 2" x 2" x .188" GALVANIZED STEEL TUBE EXTEND INTO CONCRETE. CONCRETE NOTES: 1. SIGN TO BE PORCELAIN ON STEEL WITH A BEADED TEST. BOTTOM OF SIGN TO BE 60" ABOVE FISHED SURFACE. 2. SIGN TO CONFORM TO ANSI A117.1.1986 INTERNATIONAL SYMBOL OF ACCESSIBILITY. 3. LOCATED AT HEAD OF ALL ACCESSIBLE PARKING PLACES. ACCESSIBLE PARKING SIGN TO CONFORM TO CURRENT STATE, LOCAL CODES AND REGULATIONS.4"1' - 0"6" ASPHALT AND 1" RADIUS TOOLED SIDEWALK 1/4" : 1'-0" SLOPE 4" -3/4" MINUS CRUSHED GRAVEL 4"1' - 0"6" ASPHALT AND 1" RADIUS TOOLED SIDEWALK 1/4" : 1'-0" SLOPE 4" -3/4" MINUS CRUSHED GRAVEL6"6"6"3"3" TOOLED MEDIUM BROOMED FINISH IN CENTER, TYP.SCORE PATTERN WARNING 6' - 0"5' - 0"6' - 0" SLOPE 1 1/2"SLOPE 1 1/2" + 6" MAX. SLOPE UP MAX 1:12 SLOPE UP MAX 1:12 SLOPE UP MAX 1:12 TOOLED EDGE, CONC. SIDEWALK, TYP. ASPHALT PAVING, + 0" MAX. (FLUSH) 5 A1.1 LINE OF GRADE BEHIND CURB 6" VERTICAL CURB, TYPICAL AT ALL PLANTERS 4"3' - 0"5' - 4 3/4" 7-STALL POWDER-COATED STL. BICYCLE RACK. INSTALL PER MANUFACTURER'S SPECIFICATIONS. TOUCH UP AS NECESSARY AFTER INSTALLATION. NOTE: BIKE RACK TO BE 2" ROUND SCH. 40 STEEL PIPE; BEND TO FORM & DIMENSIONS AS SHOWN. POWDERCOAT BLACK. BASIS OF DESIGN: "ROUND TUBE WAVE" BY BELTON OUTDOORS. MODEL NUMBER CBBR-7UR. WWW.BELSON.COM 1-800-323-5664. SURFACE MOUNT 1' - 3"11"1' - 3"11"1' - 3" 4" CONC. SLAB OVER 4" COMPACTED 3/4" FILL OVER NATIVE SOIL. ARCHITECT Michael Anthony Joseph STATE OF IDAHO LICENSED AR-985962 DRAWN FILE NO. DATE SHEET This document is the property of THE ARCHITECTS OFFICE, PLLC and is not to be duplicated without written authorization. REVISIONS THE ARCHITECTS OFFICE, PLLC FILE c SEAL PROJECT 499 MAIN STREET (208) 343-2931 BOISE, IDAHO 83702 TAOIDAHO.COM AUTHORITY HAVING JURISDICTION PERMIT STAMP A1.1 SITE PLAN AND DETAILS 20-708 GANDER CREEK POOL BUILDING GANDER CREEK SOUTH SUBDIVISION MERIDIAN, IDAHO 83646 MICHAEL JOSEPH, AIA FEBRUARY 8, 2021 NORTH 1" = 20'-0"1 SITE PLAN 1/4" = 1'-0"2 ADA PARKING STALL 1/2" = 1'-0"3 ACCESSIBLE PARKING SIGN 1 1/2" = 1'-0"5 FLUSH SIDEWALK TURNDOWN EDGE 1 1/2" = 1'-0"6 TYPICAL SIDEWALK TURNDOWN EDGE 1/2" = 1'-0"7 TOOLED SIDEWALK DETAIL 1/4" = 1'-0"8 ACCESSIBLE CURB CUT 1 1/2" = 1'-0"4 6" VERTICAL CURB (NO GUTTER) 3/4" = 1'-0"9 BICYCLE RACK - 7 SPACES