SITE PLAN AND DETAILSKIDDIE
POOL
N. JARBIDGE AVE.KIDDIE
POOL
GENERAL NOTES SITE PLAN:
A. BEFORE PROCEEDING TO LAY OUT THE WORK, VERIFY LAYOUT
INFORMATION SHOWN ON DRAWINGS, IN RELATION TO THE PROPERTY
SURVEY AND EXISTING BENCHMARKS. IF DISCREPANCIES ARE
DISCOVERED, NOTIFY ARCHITECT PROMPTLY.
B. ENGAGE A LAND SURVEYOR OR PROFESSIONAL ENGINEER TO LAY
OUT THE WORK USING ACCEPTED SURVEYING PRACTICES.
C. ESTABLISH BENCHMARKS AND CONTROL POINTS TO SET LINES
AND LEVELS AT EACH STORY OF CONSTRUCTION AND ELSEWHERE AS
NEEDED TO LOCATE EACH ELEMENT OF PROJECT.
D. ESTABLISH LIMITS ON USE OF PROJECT SITE. IF STAGING AREA IS
NOT DESIGNATED ON PLANS, THEN COORDINATE LOCATION W ITH
OWNER.
E. ESTABLISH DIMENSIONS WITHIN TOLERANCES INDICATED. DO NOT
SCALE DRAWINGS TO OBTAIN REQUIRED DIMENSIONS.
F. INFORM SUBCONTRACTORS OF LINES AND LEVELS TO WHICH
THEY MUST COMPLY.
G. CHECK THE LOCATION, LEVEL AND PLUMB, OF EVERY MAJOR
ELEMENT AS THE WORK PROGRESSES.
H. LOCATE AND LAY OUT CONTROL LINES AND LEVELS FOR
STRUCTURES, BUILDING FOUNDATIONS, COLUMN GRIDS, AND FLOOR
LEVELS, INCLUDING THOSE REQUIRED FOR MECHANICAL AND
ELECTRICAL WORK. TRANSFER SURVEY MARKINGS AND ELEVATIONS
FOR USE WITH CONTROL LINES AND LEVELS. LEVEL FOUNDATIONS
AND PIERS FROM TWO OR MORE LOCATIONS.
I. STAKING OF THE BUILDING REQUIRES THE GENERAL
CONTRACTOR AND THE SURVEYOR TO VERIFY ALL DIMENSIONS
COMPLETELY IN BOTH DIRECTIONS TO INSURE THE BUILDING IS
PROPERLY LOCATED ON THE SITE. NOTIFY THE ARCHITECT AND THE
CIVIL ENGINEER USED ON THIS PROJECT IF THE DIMENSIONS DO NOT
CLOSE.
J. IF STAKING IS DONE BY A FIRM OTHER THAN THE CIVIL ENGINEER
USED ON THIS PROJECT, THE CONTRACTOR IS FULLY RESPONSIBLE
FOR ALL SITE DIMENSIONS.
K. POOL CONSTRUCTION AND FENCE CONSTRUCTION TO BE DESIGN-
BUILD BY GENERAL CONTRACTOR. SUBMIT NECESSARY
DOCUMENTATION FOR PERMITTING PER CITY OF NAMPA
A1.1
7
A1.1
2
6
A1.1A1.1
8
N. JARBRIDGE AVE.PREFINISHED METAL
DOWNSPOUTS PER
ROOF PLAN, TYP.
5'-0" WROUGHT IRON
FENCE SURROUNDING
POOL DECK. SEE
LANDSCAPE PLAN.70' - 11"84' - 0"15' - 11"BICYCLE RACK -SEE
9/A1.0.
A1.1
9
R 7'R 7'25' - 6"118' - 2"
44' - 0"
SITE DATA:
PARKING SHOWN: 7 TOTAL STALLS INCLUDING
1 ACCESSIBLE STALL
PARKING REQUIRED:1:500 S.F.
2 STALLS REQUIRED
ZONING: R-8
SETBACKS: LOCAL - 10'
COLLECTOR - 25'
ALLEY - 5'
INTERIOR SIDE - 5'
REAR - 12'
BUILDING AREA: 500 S.F.
SITE COVERAGE: 6,500 S.F.
POOL, DECK, AND BLDG.
PAVED AREA / SIDE WALKS: 16,500 S.F.
LANDSCAPED AREA: 97,000 SF
HANDICAP ACCESSIBILITY
SIGN.
A1.1
3
20' - 0"3' - 0"3' - 0"3' - 0"3' - 0"5"1' - 1"5"3"4"2"4 "1' - 3"
3" WIDE PAINTED
STRIPES (2) COATS
WHITE BEDDED
REFLECTIVE PAINT
BACKGROUND PAINT
(2) COATS BLUE
PAINT STRIPING
WHERE OCCURS
CONCRETE CURB AT
DIAGONAL PARKING
WHERE OCCURS.
4" WIDE STRIPING, PAINT (2)
COATS TRAFFIC YELLOW
ALIGN WITH END OF
STALL STRIPING
96" MIN.9' - 0"
VAN ACCESSIBLE
RESERVED
PARKING
1' - 0"1' - 6"5' - 0"3' - 0"6"1' - 6"
1'-0" x 1'-6" x .080 ALUMINUM
ACCESSIBLE PARKING SIGN.
SIGN TO READ "RESERVED
PARKING" WITH
IDENTIFICATION SYMBOL AND
"VAN ACCESSIBLE" WHERE
APPLICABLE. BOLT TO STEEL
TUBE WITH 1/2" CADMIUM
PLATED BOLTS, NUTS, AND
WASHERS.
2" x 2" x .188" GALVANIZED
STEEL TUBE EXTEND INTO
CONCRETE.
CONCRETE
NOTES:
1. SIGN TO BE PORCELAIN ON STEEL
WITH A BEADED TEST.
BOTTOM OF SIGN TO BE 60" ABOVE
FISHED SURFACE.
2. SIGN TO CONFORM TO ANSI
A117.1.1986 INTERNATIONAL
SYMBOL OF ACCESSIBILITY.
3. LOCATED AT HEAD OF ALL
ACCESSIBLE PARKING PLACES.
ACCESSIBLE PARKING SIGN TO
CONFORM TO CURRENT STATE, LOCAL
CODES
AND REGULATIONS.4"1' - 0"6"
ASPHALT AND
1" RADIUS
TOOLED
SIDEWALK
1/4" : 1'-0" SLOPE
4" -3/4" MINUS
CRUSHED GRAVEL 4"1' - 0"6"
ASPHALT AND
1" RADIUS
TOOLED SIDEWALK
1/4" : 1'-0" SLOPE
4" -3/4" MINUS
CRUSHED GRAVEL6"6"6"3"3"
TOOLED
MEDIUM BROOMED
FINISH IN CENTER, TYP.SCORE PATTERN
WARNING
6' - 0"5' - 0"6' - 0"
SLOPE 1 1/2"SLOPE 1 1/2"
+ 6" MAX.
SLOPE UP
MAX 1:12
SLOPE UP
MAX 1:12
SLOPE UP
MAX 1:12
TOOLED EDGE,
CONC.
SIDEWALK, TYP.
ASPHALT PAVING,
+ 0" MAX.
(FLUSH)
5
A1.1
LINE OF GRADE
BEHIND CURB
6" VERTICAL
CURB, TYPICAL
AT ALL
PLANTERS
4"3' - 0"5' - 4 3/4"
7-STALL POWDER-COATED
STL. BICYCLE RACK.
INSTALL PER
MANUFACTURER'S
SPECIFICATIONS. TOUCH
UP AS NECESSARY AFTER
INSTALLATION.
NOTE: BIKE RACK TO BE 2" ROUND SCH. 40
STEEL PIPE; BEND TO FORM & DIMENSIONS
AS SHOWN. POWDERCOAT BLACK.
BASIS OF DESIGN: "ROUND TUBE WAVE" BY
BELTON OUTDOORS. MODEL NUMBER CBBR-7UR.
WWW.BELSON.COM 1-800-323-5664.
SURFACE MOUNT
1' - 3"11"1' - 3"11"1' - 3"
4" CONC. SLAB OVER 4"
COMPACTED 3/4" FILL OVER
NATIVE SOIL.
ARCHITECT
Michael Anthony Joseph
STATE OF IDAHO
LICENSED
AR-985962
DRAWN
FILE NO.
DATE
SHEET
This document is the property of THE ARCHITECTS
OFFICE, PLLC and is not to be duplicated without
written authorization.
REVISIONS
THE ARCHITECTS OFFICE, PLLC
FILE
c
SEAL
PROJECT
499 MAIN STREET (208) 343-2931
BOISE, IDAHO 83702 TAOIDAHO.COM
AUTHORITY HAVING JURISDICTION PERMIT STAMP
A1.1
SITE PLAN AND DETAILS
20-708
GANDER CREEK
POOL BUILDING
GANDER CREEK SOUTH
SUBDIVISION
MERIDIAN, IDAHO 83646
MICHAEL JOSEPH, AIA
FEBRUARY 8, 2021
NORTH
1" = 20'-0"1 SITE PLAN
1/4" = 1'-0"2 ADA PARKING STALL
1/2" = 1'-0"3 ACCESSIBLE PARKING SIGN
1 1/2" = 1'-0"5 FLUSH SIDEWALK TURNDOWN EDGE
1 1/2" = 1'-0"6 TYPICAL SIDEWALK TURNDOWN EDGE
1/2" = 1'-0"7 TOOLED SIDEWALK DETAIL
1/4" = 1'-0"8 ACCESSIBLE CURB CUT
1 1/2" = 1'-0"4 6" VERTICAL CURB (NO GUTTER)
3/4" = 1'-0"9 BICYCLE RACK - 7 SPACES