Loading...
A2-Foundation Plan SHOHET0 0 36'-6" 84'-6" 84'-0" 24'-8" 84'-0" FOUNDATION PLAN 1/4" = 1'-0" \z 36'-6" 6"x3O" CONC. STEM W/ #4 VERTS. 8 48" O.C. & (3) #3 FI HORIZ. TIES 8 12" O.C. ON 16"x8" CONC. FOOTING W/ (2) #4 BARS CONT. 10"x3O" CONC. STEM W/ 1*4 VERTS. 9 48" O.C. t (3) #3 F2 HORIZ. TIES 3 12" O.C. ON 20"x8" CONC. FOOTING W/ (2) #4 BARS CONT. 6"x3O" CONC. STEM W/ #4 VERTS. fl 48" O.C. & (3) #3 Fq HORIZ. TIES 8 12" O.C. ON 24"x8" CONC. FOOTING W/ (2) #4 BARS CONT. 10"x3O" CONC. STEM W/ #4 VERTS. 8 48" O.C. & (3) #3 FIO> HORIZ. TIES 8 12" O.C. ON 24"x8" CONC. FOOTING W/ (2) #4 BARS CONT. 3'-2"x2'-O"x3O" CONC. FNDTN. W/ (8) #4 VERTS. & (3) #3 F3 HORIZ. TIES 8 12" O.C. ON 4'-O"x2'-10"x8" CONC. FOOTING W/ (4) (2) #4 BARS EA WAY PONY WALL: F4 2x6's 16" O.C. ON 18"x8" CONC. FOOTING W/ (2) #4 BARS HORIZ. (CONT.) CONC. PAD: Fc, 4" CONC. ON 4" COMP. GRAVEL ON COMP. EARTH W/.006" VIS- QUEEN MOISTURE BARRIER. SLOPE SLAB MAX 2% AWAY FROM FOUNDATION. CONTROL JOINTS MAX. 12' O.C. + EXP. JOINTS AT FOUNDATION PERIMETER. NO. 4 BARS 24" O.C. SET W/ EPDXY TO FNDN. BLOCK OUT F6 FOR ACCESS (3) 1-3/4"xS-1/2" LVL's THICKEND CONC. 3'-6"x3'-6"xlO" OFOOT'G: F� CONC. W/ (4) #4 BARS HORIZ. EACH WAY THICKEND CONC. 4'-0"x4'-0"x10" OF00T'G: F8 CONC. W/ (5) #4 BARS HORIZ. EACH WAY 16"x8" FOUNDATION VENT SCREENED (AUTOMATIC FV IN HARD TO ACCESS AREAS) HD2 SIMPSON HDU2-SD52.5; (2) 2x6; 5/8" DIA. X 10" EMBED A.B. FOUNDATION NOTES GENERAL NOITES; I. NOTE ALL VENTS TO BE OPERABLE AND SCREENED, SPACING AND SIZE PER IBC 2015. 2. USE .006" VISQUEEN MOISTURE BARRIER AT CRAWL SPACE. TO LAP AT TOP OF FOOTING. 3. MINIMUM 18" OF CRAWL SPACE BELOW BOTTOM FLANGE OF FLOOR JSTS. 4. USE SILL APPROVED SILL SEALER AT MUDSILL WITH METAL DRIP EDGE. S. USE I/2" ANCHOR BOLTS, 48" O.C. WITH MIN.(2) PER WALL.. SILL TO BE OF TREATED OR NATURALLY DECAY RESISTANT SPECIES, SEE SHEARWALL SCHEDULE. 6. ALL EARTH AND GRAVEL UNDER CONCRETE SLABS TO BE COMPACTED Z. ALL CONC. MIN. 3,500 P.S.I. 8. ALL REINFORCING BARS TO BE IN GOOD CONDITION, FREE OF RUST OR OTHER DEFECTS. REINFORCING BARS TO BE OF APPRV'D GRADE AND MANUF 9. GRADE TO BE MIN. 8" BELOW TOP OF FOUNDATION. 10. USE 6" PERFORATED DRAIN SURROUNDED BY CRUSHED 3/4" ROCK AT FOOTING ELEVATION, SLOPE AT LEAST 2%, AND DIRECTED TO A SUITABLE DISCHARGE POINT 10' AWAY FROM STRUCTURE. DISCHARGE POINTS SHOULD BE PROTECTED TO PREVENT EROSION. II. FOOTING TO SET ON UNDISTURBED SOIL OF ASSUMED 1,500 P.S.I. LICENSED ARCHITECT AR-671 o- _ a' 00 a- O (v Qu \ Q 0 oU \ O m Lu o 0 Z W i W m u- LLJ U � L' g r g r o Qu =uo w z m Lau NI 3 CL ° CL c� r � = CAV g~cn O r 0 FUG S m !•U F Q O 0 cr N � Q r � r o Z Q w N w Q i 0 (y L6 Z o z -j Z g Lo i < U o ~ z iK uri � 0 z I —I I� m ~ o _ Q M W � F, w z F Q o0 O w o W x �co o -�o CN 0 Ey 1-4 Cie L o �I Lu m= W Lu 0 0 c.0 v V1 � F— U L Z_ Z Z °D X Ur�' -4 W- 6 o ^/ 1..1� � p M Q N �O W OL 0 N Z OF— 6- Q 0.1 W cc m U W o� N l U o QC m C4 o c!') Q IL Lu 0 C� z F- LU W 0-03-2019