Loading...
PZ - Staff Memo Mayor Robert E. Simison C� E IDIAN.� City Council Members: =�� Treg Bernt Brad Hoaglun Joe Borton Jessica Perreault D A H O Luke Cavener Liz Strader March 1, 2021 MEMORANDUM TO: Planning and Zoning Commission CC: Jane Suggs, Gem State Planning FROM: Joseph Dodson, Current Associate Planner RE: Foxcroft Subdivision (H-2020-0113) Dear Commissioners, The Commission and the Applicant received the staff report on February 12,2021 for the subject applications. Following receipt of the report,the Applicant requested a continuance in order to respond to some of Staff s recommended conditions of approval. The Applicant has submitted revised plans and provided additional information related to the conditions of approval and many of the concerns presented within the staff report. The revised plans have resulted in a number of recommended changes to the conditions of approval and development agreement. The revisions made by the Applicant have not changed any of the open space or layout in noticeable ways except for a loss of one building lot. Any updated numbers and analysis can be added to the staff report following the Commission's final recommendation to City Council to ensure transparency IF the Commission so chooses for Staff to update the entire staff report. Please refer to the attachments and subsequent bullet points below regarding the recommended changes from the revised plans. The revised plans show the following changes made by the Applicant in response to the staff report: • To meet the minimum dimensional standards for the R-8 zoning district in a section of the project with alley loaded homes,the Applicant removed a building lot instead of moving the road—this is an acceptable way to fix the issue presented. o Associated condition can be stricken. • The Applicant corrected the irrigation district easement width along the northern boundary and now shows adequate width outside of the building lots to have landscaping on at least one side of the multi-use pathway. o Associated condition should be stricken • Multi-use pathways throughout the single-family portions of the site are now shown in a 20' wide common lot, in line with code requirements. The segments of pathway within the Tenmile Creek Community Development Department . 33 E. Broadway Avenue, Suite 102, Meridian, ID 83642 Phone 208-884-5533 . Fax 208-888-6854 . www.meridiancity.org Easement continue to show trees on the outer side of the pathway but will still require a license agreement with the irrigation district. In addition,the condition to obtaining Alternative Compliance for not being able to provide trees on both sides of these segments of pathway is still applicable. o After discussions with the Applicant and further review of the planned pedestrian facilities,the condition regarding the construction of pathways should be modified to allow pathway construction in accord with the phasing plan. • Applicant has verified the amenities currently proposed for the multi-family development—the proposed amenities include, a clubhouse,pool, fitness facilities,pedestrian pathways, and additional open space. • In response to Staff s analysis and conditions of the proposed multi-family unit count and height, the Applicant provided the following additional information: o The Applicant did a line of sight analysis based on existing and planned elevation conditions to demonstrate the existing single-family homes to the north are at a higher elevation than the multi-family site(see Exhibit E below). The exhibit is a cross-section view of the linear distance and proposed height of the proposed apartments versus the existing SFR. ■ According to the exhibit,the proposed apartments will be approximately 90' away from the rear-yard fence of the existing SFR at its closest point. ■ The exhibit also shows the 3'floor balcony would be approximately 4' above the second floor of the adjacent SFR. o The Applicant is now showing 11 additional parking spaces in the multi-family development—four of the spaces proposed are located at the end of a dead-end drive aisle that would exceed 150' in length with the new spaces. These spaces should not be added in the final documents to ensure a fire turnaround is not needed in this area. ■ With the seven(7) additional spaces proposed that should stay,the Applicant is now proposing 425 spaces which is nearly 2 spaces per unit and is in excess of the minimum amount of 411 spaces. o After review of the additional documents and exhibit, Staff is amenable to revising the conditions related to the apartment unit count and parking. Specifically,with the distance and land elevation differences between the subject site and the existing SFR to the north(in addition to the already proposed dense landscaping), Staffs concerns regarding the 3-story apartments are largely mitigated but Commission and Council can determine whether they agree with Staffs original conditions. Staff recommends the following changes be made to the staff report by the Planning and Zoning Commission per the changes above,noted with strikeout and underline changes below: • Add a condition regarding the legal descriptions and annexation boundary to reflect the true property boundary of one of the included parcels— o At least ten(10)dqsprior to the City Council hearing,the he Applicant shall submit revised legal descriptions and exhibit maps of the annexation boundary to reflect the true property boundary, specifically that area in the very southwest corner of the property abutting the railroad property. • Add condition regarding single-family lots adjacent to multi-family development— o With future sale of single-family homes on Lots 20-32,NW Block 1,the Applicant shall include the multi-family site plan and renderings in the sales and advertising information for these homes. • A.La—Future development of this site shall be generally consistent with the approved plat, site plan,landscape plan,open space exhibit,conceptual building elevations, eeneeptual 2 r-edevelepment plan,pathway and pedestrian circulation exhibit, and the proposed phasing plan included in Section VII and the provisions contained herein. • A.Lb—The 10-foot multi-use pathway segments surrounding the development shall be constructed with each phase Prase 4 of the development as seen on the phasing plan. • A.Lc—With the first phase of development,the Applicant shall construct the extension of W. Pine Avenue,the vehicle bridge over Ten Mile Creek,and the Pine/Ten",rile into-se ti aeeer-d wit all other ACHD requirements a d in line with the signed"Dedication and Development Agreement,"as seen in exhibit VIII.L, and the ACHD conditions of approval. • A.Lf The multi family develepmen4 shall be eenstfueted m4th fie more tLan 18 4 units wi — buildings en Lots > > and 9,NE Bleek 1 (as shown on the stibmitted plat)to be no more two stories in heigh4;proposed pafk4ag shall fiet be r-edueed by more dma 20 pafk-ifig spaees following the r-eduetien in un4s. • Strike Condition A.2—With Final P14 s„r.mit4als the ppli an, shall provide -eleyafi�r-evisoa pla-as te depiet any miner-r-evisiens shew-a on the revised open spaee exhibit. • A.3—Applicant revised the plat to meet these conditions including losing a building lot instead of relocating the road in SW Block 2). o The preliminary plat included in Section VILB, dated November- 11,-NN February 24, 2021 is approved as shown. shall be revised as fellews at least ten(10)days pr-ier-te the City Couneil r.o.,ring: a. Revise!he proposed alley between SW Bleek 2 a-ad SW Bleek 3 to be a miner-ur-bawi leeal s4eet, s,..aetea M. minimum of 24 feet,,vide with, fb a-a ,.u#e no sidewalks, and tie .,fk4a. n either side. e. Redtiee appheable building lots in the single family areas of the site te aeeemmeda4e • Strike A.4a,4b, &4c—the Applicant revised the landscape plan to show these items. • Modify Condition A.5—The Applicant shall apply for Alternative Compliance with4he-fifst-each Final Plat submittal to propose an adequate alternative for all of the required pathway landscape requirements, in accord with UDC 11-5B-5. • Strike Condition A.6—NMID is not allowing a micro-path across the sub-drain. • Strike Condition A.12— single family attaehed dwellings buildings a4 least ten(10) days pfief to the Git-y COUReil heaning • Add condition regarding Conceptual Redevelopment Plan—it is not appropriate to place it with the DA so Staff is recommending a condition of approval be added to ensure concept plan is still generally adhered to: o Future redevelopment of existing homes (Lots 2 &7, SW Block 4) shall be generally consistent with the submitted Conceptual Redevelopment Plan as seen in Exhibit VII.G. Public Works has also revised their conditions following additional conversations and clarifications with Planning Staff: Strike the following conditions under VIII.B: o 1.1 — , mainline. This eandition ea-a also be satisfied with a 14 feet wide paved suffaee. The pathway shown ever-the existing sewer-a4eng the neAh pr-epeAies is stibjeet to this requirement, as weil as, roadway shall have a4 a minimum, a 14 ft wide eempaeted grave aeeess feadway eenter-ed ever-the 0 1.2—Please redesign the sa-mitafy sewef r-et4iag to elimina4e the sewer-mainline passing thfetf allowed ifAe-a manhole,with a ininiffmm 30 degrees�fangle separation). 0 1.7— with"to and thfough"fv"ir-emeffts. This fiew mainlifie shall eefineet to existing water-mains a the west and east ends 0 1.8—The water-main in N.White Leaf Way neaf SSN4H GS needs to eefmeet to the pr-epose wa4ef main to the east(Mile High Pines Siib). 0 1.9—The water-main in W. Stigaf Pine Q. that etiffenfly dead ends needs to eemeet te the pfopesed water-main te the east(Mile High Pines Stib)in N. Side Cr-eek Lane. Cuffen4ly this dead end dees not meet fire flew pr-essufe r-eqttifemeats. 0 1.10—Ther-e are a few w4er-mains in the multi family area that may have an eppefftmity4e� eliminated. See Exhibit Seetien V11(I.)Watef Mafkup fef Afeas of Pessible Wa4er-Main o In addition,remove the water markup exhibit,Exhibit V11.1 The revised exhibits are as follows: A. Revised Preliminary Plat B. Revised Conceptual Engineering Plan C. Revised Landscape Rendering D. Revised Open Space Exhibit E. Ten Mile Stub Drain Cross-section F. Conceptual Elevations of Single-Family Homes 4 A. Revised Preliminary Plat rid AA low 4d� I esm Y 19 l' 'HIP Will $ , - .. .. I � Oki I{ � — 3• sG - - ag 4' ,� ' E HO;z�z�MT„���� �J, 3 f 1 _ O 11 fTl o-3 E^ AIDS q 3o i /'LIr _r:-;, •�. z77 PRELIM I(VARY P LA—r ^� €g X •'•. - _ .•. iley Eneering,Ingnc. I '-Am;^�h�i P���EneixrevixelPunxin�l Cd�� TRILOGY DEVELOPMENT, INC 5 r _ _ �. ., i p s s t& a:e ysgeanrsnef:aBBee B.."se"s aaa ax®aeky7 '� ® s .. � €� a � -� kkyRm ka BR A&FRg Yeg56ex B9 E&9 SYAS6R leeosssyeAaa��?a�s�saeaasxaee@se�dewss9 I r 1 x' CC -CC��CCCCGGaasse'�aCCCCs'CCRg°e��®a C •'�BABYSY kY Rk8 SR R �$%I �l '��i�$ay �' 3 � � t8aw SEG4�P'�'�yw I,i.i I �,>< � p•.D I II� s n w ex a xx p.E-kvaCr::sir:.•nv•wYE k=- �ffls m eka�, egdl P F2 E L I M I N A FZ Y F-L.4'T 10 Iley Englneering,Inc. F O X C R o F-T S 0 0 0 I V 1 5 I O N pm ExemeexmelPuxnws T121 LOGY DEVELOPMENT, INC -""- —"•°'• 6 B. Revised Conceptual Engineering Plan I I �•11 I l ' ® xo� i ,. o I y I EL L � I / I S • F f 1 CZ] p M F F f _s�=sssgaG tez g om ^m w oz CONCEPTUAL ENGINEERING a p' _-4•'' Ilep Engneeling.lnc. b 8 FO X C R O FT S lJ B I V I S l O N i .pq CML EGUInEFR101I NINGIMIDD W TRILOGY DEVELOPMENT, INC "u,,- -M. 7 C. Revised Landscape Rendering ML d i e 9oL r �-8_ir'.l ]ate e ems. ' FETE�P, FOXCROFT SUBDIVISION ® o FEBRUARY 25,2021 MERIDIAN, ID PRELIMINARY PLAT LANDSCAPE PLAN g D. Revised Open Space Exhibit PARKING PRovIOEO SPACES-ate 91NG�E FunlLV PnRKING ^� nrs - -216 z SPACES -EA EACH UNIT PROPOSED HAS REOOIRED SPACES: -2D]SrANDARD CAR ENCL06ED GARAGE e i.f a HANDICAP SPACES DEETINC CODE REQUIREMENTS OPEN SPACE AND PARKING E --$laAL4FIED-1DC --_- _ -- _ �SZPea e� aza UNCOVERED SPACES 213 FOR2 OFFSTREET PARKING PER EXHIBIT FOE 5a a ----- UNII. d -" 113G3.R_1-e.13290 sf® -- -PARRNG FOR CwSNDUSE=a el Aoo rorvAL PARKING SUBDIVISION =. -SPACES 12SPACEs S 1 I ��*`�*�H� \ 191ALREOIJIREDel1 Ory BES r ARE IDENTIFIEDIT EDE IE ME� xw tx Gv C.TINTa=STOCEr DurD 4 QU LIFI ��1 µNAY A5 AN US ATIQN OF C IE sf � S.IANLE PARKING NE of , ._" rf2 -qv Fy',h �4 DRIVE—SAND OTHER _ ' 3 3 DEsraucnouE 'r 1V. 4 ry UAL DC 3G- LIPIED � { B.1.�.7,339 sf l - - ' QUALIdIED UDC 1r a-L14C J _ �L1AUFIEDUO� I� T 113G-3.13,4,4,'IOS sf — 1 I =QUA ` z U 0 z ALFIED LMC -30-3.B-1 a.5,5850-1 QUALIFIED UDC II-30-3.B.1.a. F OPEN SPACE NO DRAINAGE 59z100 MIN z > z 50,8455E Y W a � ® �•� 1.17ACRES Q m QUALIFIED UDC 11 3G 3 0 1 ILd PATHWAYS WITH LANDSCAPE 31,5985E 0 3A5 0,73ACRES Q CS ® CS' ® ®� QUALIFIED UDC II-3G-3.B.3. LE, IL 0 COLLECTOR BUFFERS Q 45,45E U 104 ACRES N a' �T ` ® QUALIFIED UDC 11,3G3.B.4. U Q ONE HALF ARTERIAL BUFFERS Z X J 2,503 sf W O a' 05 ACRES O IE F QUALIFIED UDC 11-3G-3.B.7 Mar.. ® (g QUAL IED UDC NATURAL WATERWAY 11-3G-3;'1�1.e 11,732 sf 2175ACRES p 9 E. Ten Mile Stub Drain Cross-section 3RD FLOOR BALCONY IS 4' ABOVE 2ND FLOOR OF EA?SRNG HOME EUV C T ELEV- 2S�f.01 m a grpp 25W m m p FLOOR ROOF PEM MFY-2M7M EIEV= 2��IR0 FLOOR&LLCaN1' C N 43 N nt n C ROOF PEAK G1 2610 m —o ' 261❑ 2600 FP o a 2600 2590 a 4 h 2590 2nd Floor a 2580 2nd Flo a fst F7aar � 2580 2570 Tst FHaar 20' I 25 35' ^——— ——__—` 3�711 i 1 2560 ———— 2560 ELEYL, a, ELEY-?102.3e . 2550 16 ASPHAL PATH 2550 • RAYEL � � 2540 � 254D 2+00 2+50 3+00 3+50 4+00 4+50 5+00 Ten Mile Stub Drain PROFILF F. Conceptual Elevations of Single-Family Homes 400 C: :C ■■ s 1■' 1■1 '-s ■ 400 s. : 1 y. 10 : -- AtPF 11