Loading...
Landscape PlanSDR/W R/W R/WR/WR/W1E. COMMERCIAL ST.N. EAGLE RD.FLFLFLFLFLFLFLFLOHP UGPUGP UGPUGPUGPUGPUGPUGP UGPUGPUGPUGPUGPUGPUGPUGPUGP EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EGEP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP WW 12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W FLFLFL TTTTTTTTTTTTTT TTTTTTTTTTTTTTTT T T T T T T T T T T T T T T T T T T T TTTTTTTTTTTTTTTTTTTTTTT UGPUGP UGP UGP UGP UGP UGPUGPUGPUGPUGP UGP UGPUGPUGP UGP 8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W 6''WW 8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS 8''SS 8''SS 8''SS 8''SS 8''SSGIRRGIRRGIRRGIRRGIRRGIRRGIRR GIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRUNION PACIFIC RAILROADR/W 4''SS 4''SS4''SS4''SSSS SS SS SSSSSSGIRR GIRRSDSDSDSDSDSDSDSDSDSDSDSDSDMWMWMWAD ADRDRDADRDRDDSDSDGGGGGGGMTRTTTTSSSSIRRIRRIRR6''W6''W6''W6''W6''W6''WWVWVWVWVWVWVWVWVWVWMTRWVWV20.00'PATHWAYEASEMENTRE: CIVIL25.00'IPCOEASEMENTRE: CIVIL35.00'LANDSCAPE BUFFERPROPERTY LINE, TYP.FIRE HYDRANT, TYP.12" WATER LINE, TYPTELEPHONE, TYP.TELEPHONE PEDESTAL, TYP.BURIED GAS LINE, TYP.GAS METER, TYP.UNDERGROUND POWERELECTRICAL METERUNDERGROUND POWER, TYP.UNDERGROUNDTELEPHONE, TYP.EXISTSIDEWALK, TYP.EXISTINGLIGHTSANDLIGHTPOLES,TYP.EXISTINGTREES TOREMAIN, TYP.VALLEY GUTTER, TYP.TRAFFIC SIGN, TYP.TRANSFORMER,TYP.TREE PROTECTIONFENCING, TYP.MAINTAIN 10' FROM DRIPLINEOF TREE IF POSSIBLE.SEE DETAIL X/L501EXISTING COMPACTEDGRAVEL SHOULDER TO REMAINEXISTING SOD, TYP.TO REMAINEXISTING PLANTING BEDS, TYP.TO REMAINEXISTINGCONCRETE, TYP.6" CAL. TREE TOBE REMOVEDENTIRELY6" CAL. TREE TOBE REMOVEDENTIRELY(2)MULTI-STEM12" DIA. TREETO BEREMOVEDENTIRELY.4" CAL CONIFERTO BE REMOVEDENTIRELY.(2)12" DIA.CONIFER TREETO BE REMOVEDENTIRELY.8" DIA.TREE TO BEREMOVED ENTIRELY8" DIA. TREETO BE REMOVEDENTIRELYMULTI-STEM12" DIA. TREETO BE REMOVED ENTIRELY4" CAL. CONIFER TO BEREMOVED ENTIRELY8" DIA. CONIFER TO BEREMOVED ENTIRELY8" DIA. TREE TO BEREMOVED ENTIRELY.8" DIA. TREE TO BEREMOVED ENTIRELY.6" DIA. TREETO BEREMOVEDENTIRELY.6" DIA. TREETO BEREMOVEDENTIRELY.8" DIA. TREETO BE REMOVEDENTIRELY.4" DIA. TREE TOBE REMOVED ENTIRELY.18" DIA. TREE TO BE REMOVEDENTIRELY.EXISTING LANDSCAPE BED TO REMAIN, TYP.8" DIA. TREE TO BE REMOVED ENTIRELY6" DIA. TREE TO BE REMOVED ENTIRELY8" DIA. TREE TO BE REMOVED ENTIRELY8" DIA. TREE TO BE REMOVED ENTIRELY24" DIA. TREE TO BE REMOVED ENTIRELYOIL STORAGEOIL STORAGENEW ADDITIONEXISTINGDISTRIBUTION/WAREHOUSE6" DIA. TREE TOBE REMOVED ENTIRELY6" DIA. TREETO BE REMOVEDENTIRELY24" DIA. TREE TOBE REMOVEDENTIRELY6" DIA. TREETO BEREMOVED.PROJECT INFORMATION:PROJECT NAME: HICKORY WAREHOUSEOWNER: H.O.T. 1 LLPCONTACT: SAM JOHNSONADDRESS: 2ϳ01 E. PINE AVE.MERIDIAN, IDAHO 83642PH: (208) 863-5889ARCHITECT: CUSHING TERRELLCONTACT: JOSHUA HERSEL800 W. MAIN ST., STE. 800BOISE, IDAHO 83ϳ02208.336.4900CIVIL ENGINEER: THE LAND GROUP, INC.CONTACT: JASON DENSMER, PE462 E. SHORE DR., SUITE 100EAGLE, IDAHO 83616(208) 939-4041LANDSCAPEARCHITECT: CUSHING TERRELLCONTACT: ANGELA HANSEN800 W. MAIN ST., STE. 800BOISE, IDAHO 83ϳ02(208)5ϳϳ.565ϳZONING REGULATIONSZONING DISTRICT/ LAND USE: LIGHT INDUSTRIAL (I-L)11-3B-10: TREE PRESERVATION:A.PURPOSE: THE REGULATIONS OF THIS SECTION ARE INTENDED TO PRESERVEEXISTING TREES FOUR INCH (4") CALIPER OR GREATER FROM DESTRUCTIONDURING THE DEVELOPMENT PROCESS.B.APPLICABILITY: TREE PRESERVATION IS REQUIRED IN ALL DISTRICTS.MITIGATION:a.MITIGATION SHALL BE REQUIRED FOR ALL EXISTING TREES FOUR INCH (4")CALIPER OR GREATER THAT ARE REMOVED FROM THE SITE WITH EQUALREPLACEMENT OF THE TOTAL CALIPERS LOST ON SITE UP TO AN AMOUNT OFONE HUNDRED PERCENT (100%) REPLACEMENT. (EXAMPLE: TWO 10-INCHCALIPER TREES REMOVED MAY BE MITIGATED WITH FOUR 5-INCH CALIPERTREES, FIVE 4-INCH CALIPER TREES, OR SEVEN 3-INCH CALIPER TREES.)PROPOSED:1.NO TREES TO BE REMOVED WILL BE MITIGATED. ORIGINAL PLANTING PLAN FORTHIS PROPERTY COMPLETED IN 2011 EXCEEDED THE CITY OF MERIDIANREQUIREMENTS. THE EXISTING LANDSCAPE TO BE RETAINED AT THIS LOCATIONEXCEEDS THE CITY'S REQUIREMENTS.2.ADDITIONAL TREES AND PLANT MATERIAL IS BEING PROPOSED - SEE L301.SHEET LEGENDEXISTING SODEXISTING GRAVEL SHOULDEREXISTING PLANTING BEDS WITH WOOD MULCHEXISTING DECIDUOUS TREES TO BE REMOVEDEXISTING ORNAMENTAL TREES TO BE REMOVEDEXISTING CONIFER TREES TO BE REMOVEDEXISTING DECIDUOUS TREES TO REMAINEXISTING ORNAMENTAL TREES TO REMAINEXISTING CONIFER TREES TO REMAINPROPOSED PLANTING BEDS WITH WOOD MULCH06.29.17 11:08 PM | L:\Scentsy\SCENOIL_CS\BIMCAD\LandArch\SCENOIL_L300.dwgL30OTREE REMOVALPLANHANSEN-ROSACZC TREE REMOVAL PLAN SCALE: 1" = 20'-0"0feet401" = 20'2060©| ALL RIGHTS RESERVED®REVISIONSCHECKED BY |DRAWN BY |PROJECT # |SCENTSY OIL STORAGE ADDITION H,O,T, 1, LLP E COMMERCIAL STREET, MERIDIAN ID.CZC SUBMITTAL12.02.2020NOT FOR CONSTRUCTION - PRELIMINARY DESIGN 2020SCENOIL 20.00'PATHWAYEASEMENTRE: CIVIL25.00'IPCOEASEMENTRE: CIVIL35.00'LANDSCAPE BUFFEREXISTINGCONCRETE, TYP.SDOIL STORAGEOIL STORAGENEW ADDITIONEXISTINGDISTRIBUTION/WAREHOUSE7107788XXXXXXX XXXXXXXX(1) SVA SYL(1) SVA SYL(1) COR CDO(1) CED GLA(1) PYR CAP(1) COR CDO(1) BET NIG(1) BET NIG(2) ACE CLZ(2) ACE CLZ(2) ACE GIN(2) CED BLI20.00'PATHWAYEASEMENTRE: CIVIL25.00'IPCOEASEMENTRE: CIVIL35.00'LANDSCAPE BUFFERR/W R/W R/WR/WR/W1E. COMMERCIAL ST.N. EAGLE RD.FLFLFLFLFLFLFLFLOHP UGPUGP UGPUGPUGPUGPUGPUGP UGPUGPUGPUGPUGPUGPUGPUGPUGP EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EGEP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP WW 12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W FLFLFL TTTTTTTTTTTTTT TTTTTTTTTTTTTTTT T T T T T T T T T T T T T T T T T T T TTTTTTTTTTTTTTTTTTTTTTT UGPUGP UGP UGP UGP UGP UGPUGPUGPUGPUGP UGP UGPUGPUGP UGP 8''W8''W8''W8''W8''W8''W8''W8''W8''W8''W 6''WW 8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS 8''SS 8''SS 8''SS 8''SS 8''SSGIRRGIRRGIRRGIRRGIRRGIRRGIRR GIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRUNION PACIFIC RAILROADR/W 4''SS 4''SS4''SS4''SSSS SS SS SSSSSSGIRR GIRRSDSDSDSDSDSDSDSDSDSDSDSDSDMWMWMWAD ADRDRDADRDRDDSDSDGGGGGGGMTRTTTTSSSSIRRIRRIRRSSMHRIM:2624.758"PVC IE-NTH:2618.526"PVC IE SE/SW:2618.90SSMHRIM:2626.648"PVC IE-STH:2612.1912"PVC IE EST:2612.1212"PVC IE WST:2612.02SSMHRIM:2628.288"PVC IE-STH:2612.7312"PVC IE EST:2612.5812"PVC IE WST:2612.47UNABLE TOLOCATE STUBSSCO6''W6''W6''W6''W6''W6''WSDCBGRT:2624.216"PVC IE-NTH:2623.26SDCBGRT:2624.0612"PVC IE-SW:2620.0412"PVC IE-SE:2619.86SDMHRIM:2625.5212"PVC IE-NW:2619.3712"PVC IE-STH:2619.94SDCBGRT:2624.1012"PVC IE-NE:2620.27SDCBGRT:2627.6212"PVC IE-NTH:2621.946"PVC IE-EST:2625.1012"PVC IE-STH:2622.42SDCBGRT:2625.5912"PVC IE-NW:2622.54TRENCH DRAINTRENCH DRAINWVWVWVWVWVWVWVWVWVWMTRWVWVEEEEEEEEEEEEEEEEEEEMTRPROPERTY LINE, TYP.FIRE HYDRANT, TYP.12" WATER LINE, TYPTELEPHONE, TYP.TELEPHONE PEDESTAL, TYP.BURIED GAS LINE, TYP.GAS METER, TYP.UNDERGROUND POWERELECTRICAL METERUNDERGROUND POWER, TYP.UNDERGROUNDTELEPHONE, TYP.EXISTSIDEWALK, TYP.EXISTINGLIGHTSANDLIGHTPOLES,TYP.EXISTINGTREES TOREMAIN, TYP.VALLEY GUTTER, TYP.TRAFFIC SIGN, TYP.TRANSFORMER,TYP.BICYCLERACKTREE PROTECTIONFENCING, TYP.MAINTAIN 10' FROM DRIPLINEOF TREE IF POSSIBLE.SEE DETAIL X/L501EXISTING COMPACTEDGRAVEL SHOULDER TO REMAINEXISTING SOD, TYP.TO REMAINEXISTING PLANTING BEDS, TYP.TO REMAINEXISTING LANDSCAPE BED TO REMAIN, TYP.PROJECT INFORMATION:PROJECT NAME: HICKORY WAREHOUSEOWNER: H.O.T. 1 LLPCONTACT: SAM JOHNSONADDRESS: 2701 E. PINE AVE.MERIDIAN͕ IDAHO 836ϰ2PH: (208) 863-5889ARCHITECT: CUSHING TERRELLCONTACT: JOSHUA HERSEL800 W. MAIN ST.͕ STE. 800BOISE͕ IDAHO 83702208.336.ϰ900CIVIL ENGINEER: THE LAND GROUP͕ INC.CONTACT: JASON DENSMER͕ PEϰ62 E. SHORE DR.͕ SUITE 100EAGLE͕ IDAHO 83616(208) 939-ϰ0ϰ1LANDSCAPEARCHITECT: CUSHING TERRELLCONTACT: ANGELA HANSEN800 W. MAIN ST.͕ STE. 800BOISE͕ IDAHO 83702(208)577.5657ZONING REGULATIONSZONING DISTRICT/ LAND USE: LIGHT INDUSTRIAL (I-L)SETBACK REQUIREMENTS:PROPERTY LINEDIMENSIONFRONT 0REAR 0INTERIOR SIDE 0STREET SETBACK 35STREET LANDSCAPE BUFFER STREET/ROAD CLASSIFICATIONDIMENSIONLOCAL - COMMERCIAL AVNEUE10ΖMAJOR COLLECTOR - EAGLE ROAD20Ζ MINIMUM PLANT SIZESTYPE OF TREEMINIMUM SIZEEVERGREEN TREES - 6Ζ HGHT MINIMUMORNAMENTAL TREES - 2Η CALIPERSHADE TREES -2Η CALIPERWOODY SHRUBS - 2 GALLON POT MINIMUM TREE SPECIES MIX:EXISTING TREES WITHIN THE FOOT PRINT OF THE BUILDING ADDITION ARE PROPOSED TO BE RELOCATED. NOADDITIONAL TREES ARE TO BE BROUGHT ON SITE AS A PART OF THE UPGRADES. SEE TREE RELOCATION SCHEDULEFOR TREE TYPES.NUMBER OF TREES SPECIES MIX REQUIRED: 5NUMBER OF TREE SPECIES MIX EXISTING: 27 11-3B-7: LANDSCAPE BUFFERS ALONG STREETS: ALL COMMERCIAL͕ INDUSTRIAL͕ AND OTHER NONRESIDENTIAL STREET BUFFERS SHALL BE ON A COMMON LOT ORON A PERMANENT DEDICATED BUFFER͕ MAINTAINED BY THE PROPERTY OWNER OR BUSINESS OWNERSΖASSOCIATION. (ORD. 07-1325͕ 7-10-2007) BUFFER LANDSCAPING MATERIALS: ALL REQUIRED LANDSCAPE BUFFERS ALONG STREETS SHALL BE PLANTED WITHTREES AND SHRUBS͕ LAWN͕ OR OTHER VEGETATIVE GROUND COVER.THE MINIMUM DENSITY OF ONE TREE PER THIRTY FIVE (35) LINEAR FEET IS REQUIRED. IF THIS CALCULATIONRESULTS IN A FRACTION OF FIVE (5) OR GREATER͕ ROUND UP TO AN ADDITIONAL TREE. IF THE CALCULATIONRESULTS IN A FRACTION LESS THAN FIVE (5)͕ ROUND THE NUMBER DOWN.COMMERCIAL STREET TOTAL FRONTAGE LENGTH: 336.ϰϰΖTOTAL NUMBER OF TREES REQUIRED (COMMERCIAL STREET): 10TOTAL NUMBER OF TREES EXISTING: 13TOTAL NUMBER OF TREES PROPOSED: 0EAGLE ROAD TOTAL FRONTAGE LENGTH: ϰ29.8ϰΖTOTAL NUMBER OF TREES REQUIRED (EAGLE ROAD): 12TOTAL NUMBER OF TREES EXISTING: 23TOTAL NUMBER OF ADDITIONAL TREES PROPOSED: 0PERIMETER LANDSCAPE: THE PERIMETER LANDSCAPE BUFFER SHALL BE PLANTED WITH ONE TREE PER THIRTY FIVE(35) LINEAR FEET AND SHRUBS͕ LAWN͕ OR OTHER VEGETATIVE GROUND COVER. (ORD. 05-1170͕ 8-8-2005͕ EFF.9-15-2005)PERIMETER LANDSCAPING IS EXISTING. NO ADDITIONAL CHANGES OR IMPROVEMENTS ARE PROPOSED FOR THEPERIMETER LANDSCAPE. THE FOLLOWING IS PROVIDED FOR INFORMATIONAL PURPOSES ONLY.NORTH PROPERTY LINE LENGTH: 336.ϰϰΖREQUIRED NUMBER OF TREES 10/ EXISTING NUMBER OF TREES: 13WEST PROPERTY LINE LENGTH: ϰ50.35ΖREQUIRED NUMBER OF TREES: 13 / EXISTING NUMBER OF TREES:EAST PROPERTY LINE INCLUDES AN EXISTING MULTI-USE PATHWAY AND EXISTING LANDSCAPING ADJACENT TOEAGLE ROAD - FULL LENGTH OF THE EAST PROPERTY LINE. ALL OF THESE IMPROVEMENTS ARE TO REMAIN. PERCITY OF MERIDIAN PATHWAYS AND TRAIL PLAN. LANDSCAPING IN THIS AREA MEETS THE REQUIREMENT OF CITYCODE SECTION 11-3B-12 PATHWAY LANDSCAPE. LANDSCAPING WITHIN RIGHT OF WAY: ALL LANDSCAPING WITHIN EAGLE ROAD AND E. COMMERCIAL STREET RIGHT OF WAY IS EXISTING NO ADDITIONALLANDSCAPING IS PROPOSED.BERMS IN STREET BUFFERS: BERM DESIGN IS SUBJECT TO THE PROVISIONS IN ACCORD WITH SUBSECTION 11-3B-5L.BERM IS EXISTING NO ADDITIONAL LANDSCAPING IS PROPOSED WITHIN STREET RIGHT OF WAY.11-3B-8: PARKING LOT LANDSCAPING: PURPOSE: THE PURPOSE OF PERIMETER AND INTERNAL PARKING LOT LANDSCAPING IS TO SOFTEN AND MITIGATETHE VISUAL EFFECT OF A LARGE EXPANSE OF ASPHALT IN PARKING LOTS. LANDSCAPING CAN ALSO REDUCESUMMER HEAT GAIN IN PARKING AREAS AND DEFINE PEDESTRIAN WAYS. APPLICABILITY: THE REQUIREMENTS FOR PERIMETER AND INTERNAL LOT LANDSCAPING SHALL APPLY TO ALLCOMMERCIAL͕ INDUSTRIAL AND MULTI- FAMILY DEVELOPMENT͕ WITH THE FOLLOWING EXCEPTIONS: 1. PARKING SPACES ADJOINING LOADING AREAS IN THE I-L AND I-H DISTRICTS ARE EXCLUDED FROMTHE INTERIOR LANDSCAPE REQUIREMENTS. (ORD. 05-1170͕ 8-30-2005͕ EFF. 9-15-2005) PARKING LOT LANDSCAPING: PARKIN G LOT IS EXISTING. ALL PARKING ISLANDS ARE LANDSCAPED INCLUDING TWOTREES PER ISLAND. MINIMAL LANDSCAPING CHANGES ARE PROPOSED IN PARKING LOT. NEW ROW OF PARKINGADJACENT TO BUILDING ADDITION WILL BE LANDSCAPED TO MATCH EXISTING PARKING LOT ISLANDS. INTERNAL LANDSCAPING: INTERIOR PARKING LOT LANDSCAPING SHALL BE REQUIRED ON ANY PARKING LOT WITHMORE THAN TWELVE (12) SPACES.11-3B-12 PATHWAY LANDSCAPINGLANDSCAPE ALONG PATHWAY SHALL INCLUDE TREES͕ SHRUB͕ GROUND COVER AND TURF. TREES SHALL BE SPACED1 TREE PER 100 LINEAR FEET OF PATHWAY.EXISTING MULTI-USE TRAIL PER MERIDIAN TRAILS AND PATHWAY PLAN ALONG WEST PROPERTY LINE: ϰ38.ϰ5FEETREQUIRED NUMBER OF TREES ALONG PATHWAY: ϰPROPOSED NUMBER OF TREES ALONG PATHWAY: 7PLANTING NOTES:1.SEE GENERAL NOTES FOR ADDITIONAL INFORMATION.2.EVALUATE EXISTING SITE CONDITIONS AND REMEDY AS REQUIRED TO PROVIDE FOR HEALTHYPLANT GROWTH AND MITIGATE UNSIGHTLY CONDITIONS.3.RE-GRADE, PREPARE SOIL AND PLANT ALL AREAS DISTURBED BY CONSTRUCTION ACTIVITY.PLANT PER PLANTING PLAN. FOR DISTURBANCES BEYOND PLAN, MATCH EXISTING PLANTS ANDACCESSORIES. SOD EXISTING IRRIGATED TURF DISTURBED BY CONSTRUCTION ACTIVITIES.. ADISTURBED AREA SHALL BE WHERE CONSTRUCTION ACTIVITIES INCLUDING TRENCHING,DEMOLITION, EARTHWORK, MATERIAL STORAGE, STAGING AND PARKING OR ANY OTHER FORMOF EXCAVATION, COMPACTION, OR TRAFFIC RESULTS IN THE REMOVAL OR DISPLACEMENT OFEXISTING GROUNDCOVER OR GRADE. PROVIDE SMOOTH AND CLEAN TRANSITION BETWEENEXISTING AND DISTURBANCES.4.COLLECT A SAMPLE OF EXISTING AND ANY REQUIRED SUPPLEMENTAL IMPORTED TOPSOIL ASSPECIFIED.5.PREPARE SUBGRADE AND PLACE TOPSOIL PER SPECIFICATION 329113 'SOIL PREPARATION'FOR PLANTING SOIL TYPE AND LOCATIONS.6.TURF/GRASS AREAS SHALL RECEIVE 6" OF TOPSOIL AND PLANTER AREAS SHALL RECEIVE 6" OFTOPSOIL. AT PAVING IN SHRUB/PLANTER AREAS BRING FULL TOPSOIL DEPTH TO WITHIN 3" OFFINISH GRADE TO ALLOW FOR MULCH. AT PAVING IN TURF AREAS BRING FULL TOPSOIL DEPTHTO WITHIN 1-1/2" OF FINISH GRADE TO ALLOW FOR SOD INSTALLATION. AT PAVING IN TURFAREAS BRING FULL TOPSOIL DEPTH TO WITHIN 3/4 " OF FINISH GRADE TO ALLOW FOR SEEDINSTALLATION. COORDINATE TOPSOIL INSTALLATION WITH OTHER TRADES. CONTRACTORSHALL VERIFY CHARACTERISTICS OF TOPSOIL TO BE INSTALLED AND AMEND AS REQUIRED TOGET PROPER CHARACTERISTICS AND DEPTH.7.ALL PLANT MATERIAL SHALL RECEIVE ADEQUATE AMOUNT OF WATER TO MEET WATERINGREQUIREMENTS SUPPLIED BY AN AUTOMATIC UNDERGROUND IRRIGATION SYSTEM UNLESSNOTED OTHERWISE. SEE PERFORMANCE IRRIGATION PLAN AND NOTES. PRIOR TO PLANTING,IRRIGATION SYSTEM SHALL BE INSTALLED AND FULLY OPERATIONAL AND PLANTING AREASTHOROUGHLY SOAKED. COORDINATE WITH IRRIGATION CONTRACTOR.8.PROVIDE SMOOTH AND CLEAN TRANSITION BETWEEN ALL TURF/GRASS TYPES, BOTH EXISTINGAND PROPOSED.9.INSTALL PLANTINGS AND ACCESSORIES AS DETAILED AND PER PROJECT MANUALSPECIFICATIONS.10.MAINTAIN PLANTS AND TURF/GRASSES AS SPECIFIED PER 320190 OPERATION ANDMAINTENANCE OF PLANTING.TREE, SHRUB, & PERENNIAL:1.PRIOR TO PLANTING INSTALLATION, CONTRACTOR TO CONTACT ARCHITECT FOR PLANTINSPECTION AND PLANT LAYOUT PRIOR TO DIGGING PLANTING HOLES.2.ALL PLANT MATERIAL SHALL BE INSTALLED AS DETAILED AND CONFORM TO THE CURRENTAMERICAN NURSERY AND LANDSCAPE ASSOCIATION STANDARD FOR NURSERY STOCK.3.CONTRACTOR SHALL VERIFY ALL PLANT QUANTITIES. THE ILLUSTRATED LOCATION SHALLDICTATE COUNT.4.NO PLANT SUBSTITUTIONS WILL BE ALLOWED WITHOUT WRITTEN CONSENT FROM THELANDSCAPE ARCHITECT.5.PROVIDE ORGANIC MULCH AS NOTED IN LEGEND IN PERENNIAL BEDS AND TREE RINGS.SUBMIT SAMPLES AS SPECIFIED. MODIFY FINISH GRADE ADJACENT TO WALKING SURFACES TOPREVENT MULCH FROM MIGRATING DURING RAIN EVENTS.6.INSTALL WEED BARRIER FABRIC IN ALL PLANTERS, EXCEPT PERENNIAL AREA, AS DETAILEDAND AS SPECIFIED.7.EDGING AS DETAILED AND SPECIFIED. FOR COMPACTED AREAS (PREVIOUSLY PAVED/HARDPANAREAS), SCARIFY SOILS AS SPECIFIED AND MODIFY PLANTING PIT AS SPECIFIED & DETAILED.8.IF SUBSOIL CONDITIONS SHOW EVIDENCE OF UNEXPECTED WATER SEEPAGE OR RETENTIONNOTIFY LANDSCAPE ARCHITECT IMMEDIATELY AND MITIGATE AS REQUIRED.9.WARRANTY PLANT MATERIAL AS SPECIFIED.PERFORMANCE IRRIGATION NOTES:1.SEE GENERAL NOTES AND PLANTING PLAN.2.CONTRACTOR TO MODIFY AN EXISTING UNDERGROUND AUTOMATIC IRRIGATION SYSTEM TOPROVIDE ADEQUATE WATER FOR ALL PLANT MATERIAL AS SHOWN ON L301. INSTALL MANUALDRAINS (X/LXXX) AT LOW POINTS AND AIR RELIEF VALVES (X/LXXX) AT HIGH POINTS ALONGMAINLINE (X/LXXX). INSTALL QUICK COUPLERS (X/LXXX) AT END OF MAINLINE AND ISOLATIONVALVES (X/LXXX) DOWNSTREAM OF MAINLINE TEES.3.IRRIGATION SYSTEM WATER SOURCE IS DOMESTIC FROM BUILDING WITH BACKFLOW PREVENTERPROVIDED BY PLUMBING CONTRACTOR. SEE PLUMBING FOR POINT OF CONNECTIONS &FOUNDATION WALL PENETRATION.4.CONTRACTOR TO VERIFY AVAILABLE GALLONAGE AND PRESSURE. DESIGN IRRIGATION SYSTEMBASED UPON AVAILABILITY.5.VERIFY CAPACITY OF EXISTING CONTROLLER. MODIFY ZONES AND CLOCK AS NECESSARY TOINCLUDE NEW IRRIGATION. IN THE EVENT OF ANY DISCREPANCIES, NOTIFY THE OWNER'SREPRESENTATIVE.6.PROPOSED PLANTING BEDS SHALL BE WATERED BY IN-LINE EMITTER DRIP (SEE GENERALSCHEMATIC DRIP LAYOUT (X/LXXX)), WITH DRIP ZONE CONTROL KIT ((X/LXXX)). PROVIDE PVCLATERALS TO BEDS AND CONNECT TO DRIP LINE AS NOTED AND DETAILED.7.CONTRACTOR SHALL PROVIDE SLEEVING FOR PIPE BELOW PAVEMENT. SLEEVE PER LEGEND.SUPPLY ONE EXTRA SLEEVE WITH EACH MAINLINE SLEEVE FOR CONTROL WIRES. COORDINATESLEEVE INSTALLATION WITH OTHER TRADES AND OTHER PROJECTS.8.IRRIGATION SYSTEM SHALL BE INSTALLED IN STRICT ACCORDANCE WITH ALL PERTINENT CODESAND REGULATIONS, THE REFERENCED STANDARDS, AND THE MANUFACTURER'SRECOMMENDATIONS.9.ZONES TO BE DESIGNED WITH REGARD TO PLANT MATERIAL AND WIND AND SUN EXPOSURE TOENSURE PROPER PLANT REQUIRED WATER COVERAGE.10.PROVIDE ALL COMPONENTS REQUIRED FOR PROPER WINTERIZATION OF SYSTEM.11.PRIOR TO IRRIGATION MAINLINE TRENCH BACKFILL, CONTRACTOR TO CONTACT ARCHITECT FORMAINLINE PRESSURE TEST.12.PROVIDE FIVE COPIES OF SCHEMATIC LAYOUT PRIOR TO MATERIAL PURCHASE AND THEN FINALSHOP DRAWINGS FOR WRITTEN APPROVAL. SEE SUBMITTAL REQUIREMENTS FOR ADDITIONALINFORMATION.13.INSTALL IRRIGATION SYSTEM AS DETAILED AND SPECIFIED.EXISTING TURF - SOD,MP ROTATOR / ROTARY IRRIGATIONEXISTING SHRUB ANDPERENNIAL PLANTING BED -ORGANIC MULCH + COMPOST -DRIP IRRIGATION, SEE DETAILSEDGING - SHOVELCUTDECIDUOUS TREE PLANTING -LARGE, SEE DETAILDRIP IRRIGATION IN PLANTERBEDDECIDUOUS TREE PLANTING -SMALL, SEE DETAILDRIP IRRIGATION IN PLANTERBEDCONIFEROUS TREEPLANTING, SEE DETAILDRIP IRRIGATION INPLANTER BEDSHEET LEGENDEXISTING GRAVEL SHOULDEREXISTING DECIDUOUS TREES TO REMAINEXISTING ORNAMENTAL TREES TO REMAINEXISTING CONIFER TREES TO REMAINPROPOSED SHRUB ANDPERENNIAL PLANTING BED -ORGANIC MULCH + COMPOST -DRIP IRRIGATION, SEE DETAILSTREESBOTANICAL NAMECOMMON NAMEINSTALL SIZEPKG.MATURE SIZECLASSACE AUTAcer rubrum `Autumn Flame`Autumn Flame Red Maple2" Cal.B&B30-35`H x 35-40`WCLASS IIACE CLZAcer x freemanii `Celzam` TMCelebration Freeman Maple2" Cal.B&B30-40` H x 15-20` WCLASS IIBET NIGBetula nigraRiver Birch Multi-Trunk2" Cal.B&B30-35`H x 35-40`WCLASS IICHA PENChamaecyparis nootkatensis `Pendula`Weeping Nootka Cypress8` Ht.B&B30-40` H x 15-20` WCONIFERSVA SYLFagus sylvatica `Rohan Obelisk`Rohan Obelisk European Beech2" Cal.B&B40-45`H x 30-35`WCLASS IIIGLE INEGleditsia triacanthos inermis `Skycole` TMSkyline Thornless Honey Locust2" Cal.B&B40-45`H x 30-35`WCLASS IILIQ CL2Liquidambar styraciflua `Clydesform` TMEmerald Sentinel Sweet Gum2" Cal.B&B40-45`H x 30-35`WCLASS IICONIFEROUS TREESBOTANICAL NAMECOMMON NAMEINSTALL SIZEPKG.MATURE SIZECLASSCED GLACedrus atlantica `Glauca Fastigiata`Columnar Blue Atlas Cedar8` Ht.B&B40` X 15`CONIFERCED BLICedrus deodara `Blue Ice`Blue Ice Deodar Cedar8` Ht.B&B30-40` H x 15-20` WCONIFERORNAMENTAL TREESBOTANICAL NAMECOMMON NAMEINSTALL SIZEPKG.MATURE SIZECLASSACE GINAcer ginnalaAmur Maple2" Cal.B&B15-20` H x 15-20` WCLASS ICOR CDOCornus kousa `Schmred` TMHeart Throb Kousa Dogwood2" Cal.B&B15-20` H x 15-20` WCLASS IPYR CAPPyrus calleryana `Capital`Capital Callery Pear2" Cal.B&B15-20` H x 15-20` WCLASS IISHRUBSBOTANICAL NAMECOMMON NAMEINSTALL SIZEPKG.MATURE SIZEREMARKSBRU LOOBrunnera macrophylla `Looking Glass`Looking Glass Siberian Bugloss---BUX WGMBuxus microphylla japonica `Winter Gem`Winter Gem Japanese Boxwood---CAL KARCalamagrostis x acutiflora `Karl Foerster`Karl Foerster Feather Reed Grass---CHR SNCChrysanthemum x superbum `Snowcap`Snowcap Shasta Daisy---COR VERCoreopsis verticillata `Moonbeam`Moonbeam Tickseed---COR ZAGCoreopsis verticillata `Zagreb`Zagreb Thread Leaf Coreopsis---COR HALCornus alba `Bailhalo` TMIvory Halo Dogwood---COR ELECornus alba `Elegantissima`Silveredge Dogwood---COR FARCornus stolonifera `Farrow` TMArctic Fire Red Twig Dogwood---GAU EMMGaura lindheimeri `Whiskers Deep Rose`Whiskers Deep Rose Gaura---HEM HAPHemerocallis x `Happy Returns`Happy Returns Daylily---HEM OROHemerocallis x `Stella de Oro`Stella de Oro Daylily---HEU RAOHeuchera x `Apricot`Apricot Coral Bells---HOS SGEHosta x `Sagae`Sagae Hosta---IRI B10Iris sibirica `Blue King`Siberian Iris blue---JUN SK2Juniperus scopulorum `Skyrocket`Skyrocket Juniper---LAV MUNLavandula angustifolia `Munstead`Munstead English Lavender---PAC GREPachysandra terminalis `Green Carpet`Japanese Spurge---PEN P12Penstemon x `Prairie Fire`Prairie Fire Beardtongue---PHI S15Philadelphus x `Snow Dwarf`Snow Dwarf Mock Orange---PHO FRAPhotinia x fraseriRed Tip Photinia---PHY DIAPhysocarpus opulifolius `Monlo` TMDiabolo Purple Ninebark---PRU OTTPrunus laurocerasus `Otto Luyken`Otto Luyken English Laurel---PRU SCHPrunus laurocerasus `Schipkaensis`Schipka English Laurel---PRU XCIPrunus x cistena `UCONNPC001` TMDarkstar Purple Leaf Sand Cherry---RHU GRORhus aromatica `Gro-Low`Gro-Low Fragrant Sumac---SPI GO4Spiraea x bumalda `Goldflame`Goldflame Spirea---PLANT SCHEDULE06.29.17 11:08 PM | L:\Scentsy\SCENOIL_CS\BIMCAD\LandArch\SCENOIL_L301.dwgL301PLANTINGPLANHANSEN-ROSACZC PLANTING PLAN SCALE: 1" = 20'-0"0feet401" = 20'2060©| ALL RIGHTS RESERVED®REVISIONSCHECKED BY |DRAWN BY |PROJECT # |SCENTSY OIL STORAGE ADDITION H,O,T, 1, LLP E COMMERCIAL STREET, MERIDIAN ID.CZC SUBMITTAL12.02.2020NOT FOR CONSTRUCTION - PRELIMINARY DESIGN 2020SCENOIL XLXXXDECIDUOUS TREE PLANTING1/4" = 1'-0"4'-0"2'-0"NOTES:1.SEE PLANTING GENERAL NOTESFOR MORE INFORMATION.2.REMOVE ALL TWINE, STRING,AND WIRE FROM ROOTBALL.REMOVE BURLAP FROM TOPTHIRD OF ROOTBALL.3.THE ROOT FLARE OF ALL TREESSHALL BE LEVEL WITH OR UP TO1" ABOVE GRADE.4.ALL TREES SHALL BE INSTALLEDWITH A TEMPORARY SAUCER OFRAISED SOIL AT THE EDGE OFROOT BALL TO CONTAIN WATER.REMOVE OR BREACH WATERSAUCER BEFORE WINTER.5.PULL MULCH AWAY FROMTRUNK A MINIMUM OF 6".6.PROVIDE A 3'-6" MINIMUM MULCHRADIUS AROUND TREES INGRASS AREAS.STAKE, TYP.-SEE PLANTING NOTESEDGING AS[SPECIFIED_OR_NOTED]MULCH AS[SPECIFIED_OR_NOTED]WEED BARRIER FABRICIF APPLICABLE AND AS[SPECIFIED_OR_NOTED]PLANTING SOIL AS[SPECIFIED_OR_NOTED]PLACE ROOT BALL ONRAISED RING OFUNDISTURBED NATIVE SOILROOT FLAREEXCAVATE HOLE: WIDTH = 3X DIA. OF ROOTBALL DEPTH = HEIGHT OF ROOTBALLFINISH GRADETEMPORARYWATER SAUCERTREE TIE, TYP.-SEE PLANTING NOTESXLXXXCONIFEROUS TREE PLANTING1/4" = 1'-0"NOTES:1.SEE PLANTING GENERAL NOTESFOR MORE INFORMATION.2.REMOVE ALL TWINE, STRING,AND WIRE FROM ROOTBALL.REMOVE BURLAP FROM TOPTHIRD OF ROOTBALL.3.THE ROOT FLARE OF ALL TREESSHALL BE LEVEL WITH OR UP TO1" ABOVE GRADE.6.ALL TREES SHALL BE INSTALLEDWITH A TEMPORARY SAUCER OFRAISED SOIL AT THE EDGE OFROOT BALL TO CONTAIN WATER.REMOVE OR BREACH WATERSAUCER BEFORE WINTER.7.PULL MULCH AWAY FROMTRUNK A MINIMUM OF 6".8.PROVIDE A 3'-6" MINIMUM MULCHRADIUS AROUND TREES INGRASS AREAS.9.TREE STAKES MAY BEINSTALLED AT 45° ANGLE.EXCAVATE HOLE: WIDTH = 3X DIA. OF ROOTBALL DEPTH = HEIGHT OF ROOTBALLSTAKE, TYP.-SEE PLANTING NOTESEDGING AS[SPECIFIED_OR_NOTED]MULCH AS[SPECIFIED_OR_NOTED]WEED BARRIER FABRICIF APPLICABLE AND AS[SPECIFIED_OR_NOTED]PLANTING SOIL AS[SPECIFIED_OR_NOTED]PLACE ROOT BALL ONRAISED RING OFUNDISTURBED NATIVE SOILROOT FLAREFINISH GRADETEMPORARYWATER SAUCERTREE TIE, TYP.-SEE PLANTING NOTES6"3'-0" MIN.6"4'-0"2'-0"3'-0" MIN.XLXXXSHRUB PLANTING1"=1'-0"NOTES:1.SEE PLANTING GENERALNOTES FOR MOREINFORMATION.2.REMOVE ALL ROOTCONTAINMENT MATERIALSFROM ROOTBALL.3.THE ROOT FLARE OF ALLSHRUBS SHALL BE LEVEL WITHOR UP TO 1" ABOVE GRADE.6.ALL SHRUBS SHALL BEINSTALLED WITH ATEMPORARY SAUCER OFRAISED SOIL AT THE EDGE OFROOT BALL TO CONTAINWATER. REMOVE OR BREACHWATER SAUCER BEFOREWINTER.7.PULL MULCH AWAY FROMROOT FLARE 3".EDGING AS[SPECIFIED_OR_NOTED]MULCH AS[SPECIFIED_OR_NOTED]WEED BARRIER FABRICIF APPLICABLE AND AS[SPECIFIED_OR_NOTED]PLANTING SOIL AS[SPECIFIED_OR_NOTED]PLACE ROOT BALLON RAISED RINGOF UNDISTURBEDNATIVE SOILROOT FLAREEXCAVATE HOLE: WIDTH = 2X DIA. OF ROOTBALL DEPTH = HEIGHT OF ROOTBALLFINISH GRADETEMPORARY WATERSAUCER AS[SPECIFIED_OR_NOTED]6" MIN.XLXXXPERENNIAL PLANTING1"=1'-0"NOTES:1.SEE PLANTING GENERAL NOTESFOR MORE INFORMATION.2.REMOVE ALL ROOT CONTAINMENTMATERIALS FROM ROOTBALL.3.THE CROWN OF THE ROOT MASSOF ALL PERENNIALS SHALL BELEVEL WITH OR UP TO 1" ABOVEGRADE.6.ALL PERENNIALS SHALL BEINSTALLED WITH A TEMPORARYSAUCER OF RAISED SOIL AT THEEDGE OF ROOT MASS TO CONTAINWATER. REMOVE OR BREACHWATER SAUCER BEFORE WINTER.7.PULL MULCH AWAY FROM ROOTMASS A MINIMUM OF 3".MULCH AS[SPECIFIED_OR_NOTED]WEED BARRIER FABRICIF APPLICABLE AND AS[SPECIFIED_OR_NOTED]PLANTING SOIL AS[SPECIFIED_OR_NOTED]PLACE ROOT BALLON RAISED RINGOF UNDISTURBEDNATIVE SOILCROWN OFROOT MASSEXCAVATE HOLE: WIDTH = 2X DIA. OF ROOTBALL DEPTH = HEIGHT OF ROOTBALLFINISH GRADETEMPORARY WATERSAUCER AS[SPECIFIED_OR_NOTED]6" MIN.3"3"X XYX = PLANT SPACINGSEE PLANTING SCHEDULE FOR SPACING REQUIREMENTSY = SPACING BETWEEN ROWSMULTIPLY X VALUE BY 0.86 OR 87%PLANT MATERIAL, TYP.XLXXXPLANTING LAYOUT1/2"=1'-0"EDGING AS[SPECIFIED_OR_NOTED]OUTSIDE ROW OF PLANTMATERIAL SHALL FOLLOWBED EDGE -SEE PLANTING PLAN.SPACING SHALL NOT EXCEED X.XLXXXSHOVEL CUT EDGING1"=1'-0"MULCH AS [SPECIFIED_OR_NOTED]WEED BARRIER FABRIC IF APPLICABLEAND AS [SPECIFIED_OR_NOTED]FINISH GRADEDEPTH AS [SPECIFIED_OR_NOTED]112"1'-0"PLANTING SOIL AS[SPECIFIED_OR_NOTED]UNDISTURBED NATIVE SOILFABRIC STAPLES AS[SPECIFIED_OR_NOTED]TAPER PLANTING SOIL AT EDGE TO KEEP1 1/2" BELOW FINISH GRADESHOVEL CUT EDGE AT 45° ANGLE.COMPACTEDROAD BASE-SEE [CIVIL_OR_OTHER]NOTES:1.INSTALL DRAINAGE FOREACH TREE WITHIN ALLCOMPACTED OR HARDPANAREAS. COMPACTEDAREAS MAY INCLUDESURFACES PREVIOUSLYPAVED AND/OR AREASADJACENT FOUNDATIONS.3.PLACE HOLE WITHINEXCAVATED AREA ATLOWEST POINT- NOTUNDER ROOT BALL.4.AUGER 6" MIN. DIAMETERHOLE TO FREE DRAININGSTRATA UP TO 10' DEEP.5.FOR MULTIPLE TREES-AUGERED HOLES WILL BEA MINIMUM OF 24" APART.PLACE ROOT BALL ONRAISED RING OFUNDISTURBED NATIVESOIL IF PRESENT- ORCOMPACTED ROAD BASECURB-SEE [CIVIL_OR_OTHER]TREE PLANTING-SEE DETAILFINISH GRADEFREE DRAININGMATERIALXLXXXPLANTING IN COMPACTED SOILS1/2"=1'-0"DEPTH AS[SPECIFIED_OR_NOTED]AUGER TOFREE DRAININGSTRATA OR UPTO 10'-0"©| ALL RIGHTS RESERVED®REVISIONSCHECKED BY |DRAWN BY |PROJECT # |SCENTSY OIL STORAGE ADDITION H,O,T, 1, LLP E COMMERCIAL STREET, MERIDIAN ID.CZC SUBMITTAL12.02.2020NOT FOR CONSTRUCTION - PRELIMINARY DESIGN 2020SCENOIL06.29.17 11:08 PM | L:\Scentsy\SCENOIL_CS\BIMCAD\LandArch\SCENOIL_L501.dwgL501PLANTINGDETAILSHANSEN-ROSA NOTES:1.TAPE & BUNDLE ALL WIRING AT10'-0" INTERVALS.2.TIE A LOOSE 20" LOOP INWIRING AT ALL CHANGES INDIRECTION GREATER THAN 30°UNTIE ALL LOOPS AFTERMAKING CONNECTIONS.3.BURY MARKING TAPE 6" ABOVEALL DIRECT BURIAL WIRING,LATERAL LINES, AND MAINLINE.4.ALL WIRING UNDER PAVEMENTSHALL BE THROUGH SLEEVES-SEE DETAIL.5.ALL SPLICES SHALL BE MADE INVALVE BOXES AND LOCATED ONAS-BUILT PLANS.TYPICAL SECTIONOF A SHARED TRENCH18" MIN. DEPTH4"MIN.FINISH GRADELATERALMAINLINELOW VOLTAGEWIRE IN CONDUITIF APPLICABLEBEDDING ASSPECIFIEDBACKFILL WITHEXCAVATIONMATERIAL REMOVEDFROM TRENCH12" MIN. DEPTHXLXXXIRRIGATION TRENCH1"=1'-0"ASSUMPTIONS:1.SYSTEM WILL BEWINTERIZED.2.JURISDICTION ALLOWSMAINLINE TO BE ABOVEFROST DEPTH.6" MARKERTAPE, TYP.2" MIN.COVER NOTES:1.ALL IRRIGATION SLEEVINGSHALL BE (2) SIZES LARGERTHAN PIPE OR COMBINATIONOF PIPES THEREIN ENCLOSED,WITH MINIMUM SIZE TO BE 4"SCHEDULE 40 PVC.2.SUPPLY (1) EXTRA SLEEVEWITH EACH IRRIGATIONSLEEVE FOR CONTROL WIRES.BORE UNDER EXISTINGPAVING WHERE REQUIRED.BORE SEPARATELY FORCONTROL WIRES.3.BURY MARKING TAPE ABOVEALL SLEEVES 6" BELOWPAVEMENT.4.INSTALL 3" HT IRRIGATION "I"STAMP IN PAVEMENT WHERESLEEVES ARE LOCATEDUNDER NEW PAVEMENT.5.WHEN TRENCHING PROVIDEA 4" CLEARANCE AROUNDSIDES OF SLEEVES. SLOPESIDES OF TRENCH PER OSHASPECIFICATIONS.SECTION2'-0" 4" MIN.FINISH GRADEIRRIGATION SLEEVECONTROLLERWIRE SLEEVEIF APPLICABLEBEDDING ASSPECIFIEDBACKFILL WITHEXCAVATIONMATERIAL REMOVEDFROM TRENCH6"4" MIN.XLXXXIRRIGATION SLEEVE1"=1'-0"6" MARKERTAPE, TYP.6" MIN.6" MIN. 18" TYP.NEAREST JOINTIF APPLICABLESTAMPED LETTERPAVEMENTPAVEMENT EDGEPLANEXTEND SLEEVE 1'-0" BEYOND PAVEMENT IRRIGATION SLEEVEASSUMPTIONS:1.SYSTEM WILL BEWINTERIZED.2.JURISDICTION ALLOWSMAINLINE TO BE ABOVEFROST DEPTH.2" MIN. COVER XLXXXWATER POINT OF CONNECTION AT BUILDINGNTSBPFSISOLATION VALVE, TYP.-SEE DETAILBACKFLOW PREVENTOR-SEE PLUMBINGQUICK COUPLER, TYP.-SEE DETAILDOMESTIC WATERFROM BUILDINGIRRIGATION MAINLINEMANUAL DRAIN, TYP.-SEE DETAILMASTER VALVE(ELECTRIC CONTROL VALVE)-SEE DETAILFLOW SENSOR-SEE DETAILBUILDING WALLNOTES:1.CONNECTION ASSEMBLY INFORMATIONSHOWN IS SCHEMATIC ONLY.2.SEE IRRIGATION PLAN, SPECIFICATION,AND LEGEND FOR MORE INFORMATION.3.COORDINATE BACKFLOW PREVENTORAND MAINLINE SIZE WITH PLUMBING ASNECESSARY.NOTES:1.PLAN ON ALTERATIONS TO THIS DETAILFOR YOUR INDIVIDUAL PROJECT.2.ASSUMES BACKFLOW WILL BELOCATED WITHIN BUILDING.3.LOCATE POC ON PLAN. IF POC EXITSBUILDING WITHIN PAVEMENT INCLUDECONCRETE VAULT DETAIL AND SIZEACCORDINGLY.4.VERIFY AVAILABLE PRESSURE ANDGALLONAGE AND LINE SIZE; INCLUDEBOOSTER PUMP IF NECESSARY.XLXXXWATER POINT OF CONNECTION AT METERNTSBPFSMISOLATION VALVE, TYP.-SEE DETAILBACKFLOW CONNECTION-SEE DETAILMETER PITNOTES:1.CONNECTION ASSEMBLY INFORMATIONSHOWN IS SCHEMATIC ONLY.2.SEE IRRIGATION PLAN, SPECIFICATION,AND LEGEND FOR MORE INFORMATION.3.COORDINATE METER PIT WITH LOCALJURISDICTION AS NECESSARY.QUICK COUPLER, TYP.-SEE DETAILDOMESTIC WATER SERVICEIRRIGATION MAINLINEMANUAL DRAIN, TYP.-SEE DETAILMASTER VALVE(ELECTRIC CONTROL VALVE)-SEE DETAILFLOW SENSOR-SEE DETAILNOTES:1.PLAN ON ALTERATIONS TO THIS DETAILFOR YOUR INDIVIDUAL PROJECT.2.ASSUMES BACKFLOW WILL BELOCATED ON OUTSIDE OF BUILDING.3.LOCATE POC ON PLAN. IF POC EXITSMETER PIT WITHIN PAVEMENT INCLUDECONCRETE VAULT DETAIL AND SIZEACCORDINGLY.4.VERIFY AVAILABLE PRESSURE ANDGALLONAGE AND LINE SIZE; INCLUDEBOOSTER PUMP IF NECESSARY.5.COORDINATE METER PIT AND MAINLINESIZE WITH CIVIL IF APPLICABLE.NOTES:1.VALVE TO BESUPPORTED BYGRAVEL, PROVIDEBLOCK SHIM ASREQUIRED.2.SIZE VALVE ANDPIPING ASSPECIFIED.3.WHEREVERPOSSIBLE INSTALLVALVE BOXES INPLANTING BEDS.SEE IRRIGATIONPLAN FOR MOREINFORMATION.XLXXXISOLATION VALVE1 1/2"=1'-0"FINISH GRADEGATE OR BALLVALVEVALVE BOX3/4" CRUSHEDMINUS GRAVELBRICK SUPPORTS,TYP.ASSUMPTIONS:1.26" x 19" x 12" VALVE BOXWITH DEPTH EXTENDER2.2" DIA. 18" DEPTHMAINLINE3.SYSTEM WILL BEWINTERIZED.4.MAINLINE SIZES UP TO 2"ONLY (2.5" AND GREATERWILL REQUIREMODIFICATION OF DETAILAND WILL BE SUBJECTTO ADDITIONAL REVIEW).MAINLINEVALVE BOXEXTENSION, TYP.ADD AS NECESSARYVALVE BOX COVERSCHEDULE 80PVC UNION, TYP.NOTES:1.DOUBLE SWING JOINT SHALL BESCHEDULE 80 PVC NIPPLE WITH(3) MARLEX STREET ELBOWS.2.WHEREVER POSSIBLE INSTALLVALVE BOXES IN PLANTINGBEDS. SEE IRRIGATION PLANFOR MORE INFORMATION.MAINLINEXLXXXQUICK COUPLER1 1/2"=1'-0"BRICK SUPPORTS,TYP.FINISH GRADEQUICK COUPLERVALVE BOX WITH COVER3/4" CRUSHEDMINUS GRAVEL24" #4 REBAR WITH CLAMPSDOUBLE SWING JOINTMAIN LINE TEE OR ELLASSUMPTIONS:1.RIGID JOINT2.10" VALVE BOX3.2" DIA. 18" DEPTH MAINLINE4.SYSTEM WILL BE WINTERIZED.4.DETAIL FOR MAINLINE SIZES UPTO 2" ONLY (2.5" AND GREATERWILL REQUIRE MODIFICATIONOF DETAIL AND WILL BESUBJECT TO ADDITIONALREVIEW).MAINLINEXLXXXMANUAL DRAIN1"=1'-0"FINISH GRADEPVC SCHEDULE 40 FITTINGSAND SCHEDULE 80THREADED NIPPLES, TYP.1" BRONZE BALL ORGATE VALVEGRAVEL SUMP WITH A MIN.3 CUBIC YARDS OF1 1/2 " WASHED AGGREGATE WRAPPED IN FILTER FABRICAS SPECIFIED10" ROUND VALVE BOX3/4" CRUSHEDMINUS GRAVELMAINLINE WITH 1" TEEON BOTTOM6" DIA. PVC RISER,LENGTH AS REQUIRED4" MIN.NOTES:1.INSTALL MANUALDRAIN AT LOWESTPOINT ON MAINLINE.2.RISER TO BESUPPORTED BYGRAVEL.3.VALVE AND PIPINGAS SPECIFIED.4.WHEREVERPOSSIBLE INSTALLVALVE BOXES INPLANTING BEDS.SEE IRRIGATIONPLAN FOR MOREINFORMATION.SCHEDULE 80 PVCUNION, TYP.ASSUMPTIONS:1.10" ROUND VALVE BOX2.2" DIA. 18" DEPTHMAINLINE3.SYSTEM WILL BEWINTERIZED.4.MAINLINE SIZES UP TO 2"ONLY (2.5" ANDGREATER WILL REQUIREMODIFICATION OFDETAIL AND WILL BESUBJECT TOADDITIONAL REVIEW).ASSUMPTIONS:1.22 x 17" x 12" VALVE BOX2.2" DIA. 18" DEPTH MAINLINE3.1" DIA. 12" DEPTH LATERAL4.SYSTEM WILL BE WINTERIZED.5.MAINLINE SIZES UP TO 2" ONLY(2.5" AND GREATER WILL REQUIREMODIFICATION OF DETAIL ANDWILL BE SUBJECT TO ADDITIONALREVIEW).NOTES:1.VALVE TO BESUPPORTED BYGRAVEL, PROVIDEBLOCK SHIM ASREQUIRED.2.SIZE VALVE AND PIPINGAS SPECIFIED.3.DIRECT BURIAL WIREMIN. 18/4 WIRE TOINTERFACE PANEL. MIN.RUN OF 1,000 LF4.WHEREVER POSSIBLEINSTALL VALVE BOXESIN PLANTING BEDS. SEEIRRIGATION PLAN FORMORE INFORMATION.CONTROL VALVEBRICK SUPPORTS, TYP.SCHEDULE 80 PVCUNION, TYP.DECODER SYSTEMIF APPLICABLEMAINLINE3/4" CRUSHED MINUS GRAVELSERVICE TEEXLXXXELECTRIC CONTROL VALVE1 1/2"=1'-0"FINISH GRADEVALVE BOX COVER3M DBY-6 WATERPROOFCONNECTOR, TYP.18"-24" OF COILED WIREDISTRIB.PIPINGXLXXXFLOW SENSOR3/4"=1'-0"FLOWSENSORNOTES:1.INSTALL FLOW SENSOR ALONGMAINLINE AFTER MASTER VALVE ANDACCORDING TO MANUF. WRITTENSPECIFICATIONS.2.SIZE FLOW SENSOR BASED UPONREQUIRED GPM NEEDED FORPROJECT. SIZE VALVE AND PIPING ASSPECIFIED.3.INLET PIPE LENGTH OF SENSOR MUSTBE MIN. 10X PIPE DIA. STRAIGHT,CLEAN RUN OF PIPE, NO FITTINGS ORTURNS. OUTLET PIPE LENGTH OFSENSOR MUST ME MIN. 5X PIPE DIA.OF STRAIGHT CLEAN RUN OF PIPE,NO FITTINGS OR TURNS.4.DIRECT BURIAL WIRE MIN. 18/4 WIRETO INTERFACE PANEL. MIN. RUN OF1,000 LF.5.WHEREVER POSSIBLE INSTALL VALVEBOXES IN PLANTING BEDS. SEEIRRIGATION PLAN FOR MOREINFORMATION.ASSUMPTIONS:1.FLOW SENSOR BASED ON MODEL HFSWITH FCT-150 SCHED. 40 SENSOR ASMANUFACTURED BY HUNTER.2.SYSTEM WILL BE WINTERIZED.3.JURISDICTION ALLOWS MAINLINE TOBE ABOVE FROST DEPTH.INLET MIN. LENGTH10X PIPE DIA.FINALGRADEOUTLETMIN. LENGTH5X PIPE DIA.18"-24" OF COILED WIRE3M DBY-6 WATERPROOFCONNECTOR, TYP.MASTERVALVE(SEEELECTRICCONTROLVALVE)MAINLINEXLXXXIRRIGATION BACKFLOW CONNECTION3/4"=1'-0"ENCLOSUREQUICKCOUPLERBACKFLOW PREVENTORCONCRETEPADNOTES:1.SIZEENCLOSURE TOCOVER EQUIP.PER LINE SIZE.2.SIZE CONCRETEPAD TOENCLOSURE.SEE PLAN FORLOCATION.4.PIPING ANDFITTINGS TO BEGALVANIZED..PROVIDEPLASTICCOATING ONPIPING THATCONTACTS SOIL.5.EXTEND PLASTICCOATEDGALVANIZEDPIPE MIN. 10'-0"BEYOND ELL.6.SEE IRRIGATIONSPECIFICATIONFOR MOREINFORMATION.MAIN LINEGATE OR BALLVALVE AS SPECIFIED,LINE SIZE.NOTES:1.ENCLOSURE SHOWN 5'-6" x 3' x 3'.2.SIZE CONCRETE PAD TO ENCLOSURE.3.ABOVE GROUND PIPING SHALL BE GALAVANIZED6"MIN.FINALGRADEUNION, TYP.3"MIN.6" SLEEVE,TYP.6"MIN.6"MIN.PLASTICCOATEDGALVANIZEDELLWATERSERVICENOTES:1.INSTALL VALVE AT HIGHESTPOINT ON MAINLINE.2.VALVE TO BE BRACED BYGRAVEL, PROVIDE REBARSTAKING AS REQUIRED.3.SIZE VALVE AND PIPING ASSPECIFIED.4.WHEREVER POSSIBLE INSTALLVALVE BOXES IN PLANTINGBEDS. SEE IRRIGATION PLANFOR MORE INFORMATION.XLXXXAIR RELIEF VALVE1 1/2"=1'-0"FINISH GRADEPVC UNIONVALVE BOX3/4" CRUSHEDMINUS GRAVELBRICK SUPPORTS, TYP.SERVICE TEEASSUMPTIONS:1.10" ROUND VALVE BOX2.2" DIA. 18" DEPTH MAINLINE3.SYSTEM WILL BE WINTERIZED.4.MAINLINE SIZES UP TO 2" ONLY(2.5" AND GREATER WILLREQUIRE MODIFICATION OFDETAIL AND WILL BE SUBJECTTO ADDITIONAL REVIEW).MAINLINEVALVE BOX COVERBERMAD AIR RELEASE VALVEOR APPROVED EQUALBALL VALVEASSUMPTIONS:1.BOX SHOWN BASED ON HUNTERPRO-C MODEL2.WALL MOUNTED3.NOTES:1.SEE IRRIGATIONSPECIFICATION AND LEGENDFOR MORE INFORMATION.2.INSTALLATION TO BECOMPLETED IN ACCORDANCEWITH MANUFACTURER'SSPECIFICATIONS.3.MOUNT CONTROLLER AT EYELEVEL UNLESS OTHERWISENOTED.4.CONTROLLER SHALL BEHARD-WIRED TO GROUNDED110 VAC SOURCE UNLESSOTHERWISE NOTED.COORDINATE INSTALLATIONWITH ELECTRICAL.5.PROVIDE IRRIGATION ZONELIST AS SPECIFIED.XLXXXCONTROLLER1 1/2"=1'-0"ENSURE MINIMUMCLEARANCE FORDOOR OPENINGCONTROLLERCONDUITCONTROL WIREINTERIOR OREXTERIOR WALL-SEE PLANIRRIGATIONZONE LISTCONTROLLERPOWER SOURCEASSUMPTIONS:1.MODEL SHOWN HUNTER SOLAR SYNC.2.WALL MOUNTED3.SOLAR SYNC TYPICALLY INDOORAPPLICATION. USE CONTROLLER WITHBUILT IN MODULE FOR EXTERIORAPPLICATIONS.NOTES:1.SEE IRRIGATIONSPECIFICATION AND LEGENDFOR MORE INFORMATION.2.INSTALLATION TO BECOMPLETED INACCORDANCE WITHMANUFACTURER'SSPECIFICATIONS.3.MOUNT WEATHER STATIONWITH CLEAR EXPOSURE TOWEATHER IN LOCATIONSHOWN ON PLANS. MOUNTWITH COMMON SENSE SOAS TO NOT TO VISUALLYDETRACT FROM ITSSURROUNDINGS.4.MOUNT RECEIVER IFAPPLICABLE ON WALL NEXTTO CONTROLLER.5.MOUNT MODULE IFAPPLICABLE WITHIN 6'-0" OFCONTROLLER ON WALL.XLXXXWEATHER STATION1 1/2"=1'-0"IRRIGATIONCONTROLLERUP TO 800' AWAY IF WIRELESSWIRELESSRECEIVERIF APPLICABLESUPPORTINGMODULE IFAPPLICABLEMOUNTING BRACKETWEATHER STATIONEXTERIOR SECTIONSCALE: 1/4" =1'-0EXTERIOR WALL OR POLEEXTERIOR OR INTERIOR WALLVIEW10'-0" MIN.PER MANUFACTURER XLXXXSPRINKLER HEAD3"=1'-0"ASSUMPTIONS:1.DETAILINTERCHANGEABLEFOR SPRAY, ROTOR,BUBBLERS. SPECREFERS TO THESEAS "SPRINKLERS"2.RIGID JOINT3.1" DIA. 12" DEPTHLATERAL4.6" RISER5.SYSTEM WILL BEWINTERIZED.NOTES:1.DOUBLE SWING JOINTSHALL BE SCHEDULE80 PVC NIPPLE WITH(3) MARLEX STREETELBOWS.2.SPRINKLER NOZZLE,BODY AS SPECIFIED.3.INSTALL SPRINKLERSA MINIMUM 12" FROMBUILDINGS ANDWALLS.SPRINKLERBODYFINISHGRADEDISTRIBUTION PIPINGDOUBLESWING JOINTLATERALTEE OR ELLSPRINKLERNOZZLE6"12" TURF, TYP.1" PLANTER BED, TYP.ADJACENTHARDSCAPE©| ALL RIGHTS RESERVED®REVISIONSCHECKED BY |DRAWN BY |PROJECT # |SCENTSY OIL STORAGE ADDITION H,O,T, 1, LLP E COMMERCIAL STREET, MERIDIAN ID.CZC SUBMITTAL12.02.2020NOT FOR CONSTRUCTION - PRELIMINARY DESIGN 2020SCENOIL12.03.20 07:25 PM | L:\Scentsy\SCENOIL_CS\BIMCAD\LandArch\SCENOIL_L502.dwgL502IRRIGATIONDETAILSHANSEN-ROSA NOTES:1.INSTALL VALVE AT HIGHESTPOINT ON DISTRIBUTIONPIPING.2.VALVE AND PIPING ASSPECIFIED.3.INSTALL ONE DRIP AIR RELIEFVALVE PER DRIP AREA- SEESCHEMATIC DRIP LAYOUTDETAIL. MULTIPLE DRIPAREAS MAY BE WITHIN ASINGLE DRIP ZONE.4.WHEREVER POSSIBLEINSTALL VALVE BOXES INPLANTING BEDS. SEEIRRIGATION PLAN FOR MOREINFORMATION.XLXXXDRIP AIR RELIEF VALVE1 1/2"=1'-0"FINISH GRADEVALVE BOXBRICK SUPPORTS, TYP.3/4" CRUSHEDMINUS GRAVELASSUMPTIONS:1.MANUAL DRAIN VALVE BASEDON TLAVRV AS MANUF. BYNETAFIM,WWW.NETAFIMUSA.COM.2.7" ROUND VALVE BOX3.SYSTEM WILL BE WINTERIZED.VALVE BOX COVERDISTRIBUTIONPIPING, TYP.DRIP AIR RELIEF VALVEMULCHDISTRIB.PIPINGDRIP LINE TEE OR ELLASSUMPTIONS:1.22 x 17" x 12" VALVE BOX(MEANT FOR A SINGLE VALVEONLY- UP BOX SIZE FOR MORE)2.2" DIA. 18" DEPTH MAINLINE3.1" DIA. 12" DEPTH LATERAL4.SYSTEM WILL BE WINTERIZED.5.MAINLINE SIZES UP TO 2" ONLY(2.5" AND GREATER WILLREQUIRE MODIFICATION OFDETAIL AND WILL BE SUBJECTTO ADDITIONAL REVIEW).NOTES:1.VALVE TO BESUPPORTED BYGRAVEL,PROVIDE BLOCKSHIM ASREQUIRED.2.SIZE VALVE ANDPIPING ASSPECIFIED.3.DIRECT BURIALWIRE MIN. 18/4WIRE TOINTERFACEPANEL. MIN. RUNOF 1,000 LF4.WHEREVERPOSSIBLEINSTALL VALVEBOXES INPLANTING BEDS.SEE IRRIGATIONPLAN FOR MOREINFORMATION.FINISH GRADECONTROL VALVEVALVE BOX COVERSCHEDULE 80 PVCUNION, TYP.DECODER SYSTEMIF APPLICABLEMAINLINESERVICE TEE3M DBY-6 WATERPROOFCONNECTOR, TYP.18"-24" OF COILED WIREXLXXXDRIP CONTROL VALVE1 1/2"=1'-0"FILTERBRICK SUPPORTS, TYP.3/4" CRUSHEDMINUS GRAVELDISTRIB.PIPINGFINISH GRADEELLDEPTH-SEE TRENCHING DETAIL MULCHGEOTEXTILEIF APPLICABLETIE DOWN STAKEPLANTING SOILXLXXXDRIP MANIFOLD3"=1'-0"ASSUMPTIONS:1.DRAWN TO 1" DISTRIBUTIONLINE, 34" DRIPLINE.DISTRIBUTION PIPINGDRIP LINERISERNOTES:1.RISER, HEADER, TEES, AND ELLSTO MATCH DISTRIBUTION PIPINGMATERIAL.2.PLACE TIE DOWN STAKES EVERY3'-0" IN SAND; 4'-0" IN LOAM, 5'-0"IN CLAY ON DRIP LINE.3.AT FITTINGS WHERE THERE IS ACHANGE IN DIRECTION USE TIEDOWN STAKES ON EACH LEG OFTHE CHANGE OF DIRECTION.HEADER TEE OR ELLXLXXXSCHEMATIC DRIP LAYOUTNTSNOTES:1.DIAGRAM SHOWN IS SCHEMATIC.LOCATE DRIP MANUAL DRAINS, AIRRELIEF VALVES AND ADJACENTDISTRIBUTION PIPING WITHIN DRIP ZONEPERIMETER- SEE IRRIGATION PLAN.2.INSTALL DRIP AIR RELIEF VALVES AT THEHIGHEST POINTS ON DISTRIBUTIONPIPING. INSTALL ONE VALVE PER EACHDRIP AREA WITHIN THE DRIP ZONE.3.INSTALL DRIP MANUAL DRAINS ATLOWEST POINTS ON DISTRIBUTIONPIPING. INSTALL ONE VALVE PER EACHDRIP AREA WITHIN THE DRIP ZONE.NOTES:1.PLAN ON ALTERATIONS TO THISDETAIL FOR YOUR INDIVIDUALPROJECT.DRIP TUBING, TYP.DISTRIBUTION PIPINGDRIP CONTROL VALVE-SEE DETAILMAINLINEDRIP MANUAL DRAIN, TYP.-SEE DETAILSUPPLY HEADER, TYP.PVC IRRIGATION SLEEVE, TYP.AS NECESSARY-SEE DETAILDRIP AIR RELIEFVALVE, TYP.-SEE DETAILDRIP MANIFOLD-SEE DETAILDISTRIBUTIONPIPINGXLXXXDRIP MANUAL DRAIN1 1/2"=1'-0"FINISH GRADEVALVE BOXBRICK SUPPORTS, TYP.3/4" CRUSHEDMINUS GRAVEL SUMP12" X 12" X 12"VALVE BOX COVERDRIP LINE TEE OR ELLMULCHNOTES:1.INSTALL VALVE AT LOWESTPOINT ON DISTRIBUTIONPIPING.2.VALVE TO BE SUPPORTED BYGRAVEL, PROVIDE BLOCKSHIM AS REQUIRED.3.VALVE AND PIPING ASSPECIFIED.3.INSTALL ONE DRAIN VALVEPER DRIP AREA- SEESCHEMATIC DRIP LAYOUTDETAIL. MULTIPLE DRIPAREAS MAY BE WITHIN ASINGLE DRIP ZONE.4.WHEREVER POSSIBLEINSTALL VALVE BOXES INPLANTING BEDS. SEEIRRIGATION PLAN FOR MOREINFORMATION.ASSUMPTIONS:1.MANUAL DRAIN VALVE BASEDON TLSOV AS MANUF. BYNETAFIM,WWW.NETAFIMUSA.COM.2.7" ROUND VALVE BOX3.SYSTEM WILL BE WINTERIZED.DRIP MANUALDRAIN©| ALL RIGHTS RESERVED®REVISIONSCHECKED BY |DRAWN BY |PROJECT # |SCENTSY OIL STORAGE ADDITION H,O,T, 1, LLP E COMMERCIAL STREET, MERIDIAN ID.CZC SUBMITTAL12.02.2020NOT FOR CONSTRUCTION - PRELIMINARY DESIGN 2020SCENOIL12.03.20 07:25 PM | L:\Scentsy\SCENOIL_CS\BIMCAD\LandArch\SCENOIL_L502.dwgL503IRRIGATIONDETAILSHANSEN-ROSA