Loading...
ACHD Transmittal (A-2020-0224)Applicant name:JOSH SHIVERICK, CUSHING TERRELL Phone: Applicant address:800 WEST MAIN STREET SUITE 800, BOISE, ID 83702 Email:Joshshiverick@cushingterrell.com Owner name:SAM JOHNSON, HOT1 LLLP Phone:Fax: Owner address: 2701 EAST PINE AVENUE, MERIDIAN, ID 83642 Email: Administrative Applicant Information Type of Review Requested File number:A-2020-0224 Assigned Planner:Alan Tiefenbach Related Files: Subject Property Information Location/street address:501 N EAGLE RD Assessor's parcel number(s):R7724570100 Township, range, section:3N1E8 Agent name (e.g. architect, engineer, developer, representative):JOSH SHIVERICK Firm name:CUSHING TERRELL Phone:Fax: Address:800 WEST MAIN STREET SUITE 800 Email:Joshshiverick@cushingterrell.com Contact name:Phone:Fax: Contact address:Email: Project/Application Name:Scentsy Oil Storage Building Description of Work:See Narrative Project Description Planning Division ADMINISTRATIVE APPLICATION 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 1 APPLICATION TYPES Alternative Compliance - ALT:UNCHECKED Certificate of Zoning Compliance - CZC:CHECKED Does project have prior approval?:No Does your project contain new construction and/or modifications to an existing building or the site?: Yes Design Review - DES:CHECKED Private Street - PS:UNCHECKED Vacation - VAC:UNCHECKED ADDRESS VERIFICATION Address Verification Permit Number:LDAV-2020-0756 TYPE OF USE PROPOSED Residential:UNCHECKED Office:UNCHECKED Commercial:CHECKED Employment:UNCHECKED Industrial:UNCHECKED Single-Family Detached:UNCHECKED Single-Family Attached:UNCHECKED Townhouse:UNCHECKED Duplex:UNCHECKED Multi-Family:UNCHECKED Vertically Integrated:UNCHECKED PUBLIC WORKS INFRASTRUCTURE Does this project require the extension of public infrastructure?:No I agree to upload required checklist items for review:UNCHECKED I acknowledge deferral of the required checklist items, may require additional review time: UNCHECKED I agree to upload required checklist items with the building application:UNCHECKED PROPERTY INFORMATION General Location:Eagle Road Current Land Use:I-L Total Acreage:8.12 Prior Approvals (File Numbers):0 ZONING DISTRICT(S) R-2:UNCHECKED R-4:UNCHECKED R-8:UNCHECKED R-15:UNCHECKED R-40:UNCHECKED Application Information 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 3 C-N:UNCHECKED C-C:UNCHECKED C-G:UNCHECKED L-O:UNCHECKED M-E:UNCHECKED H-E:UNCHECKED I-L:CHECKED I-H:UNCHECKED O-T:UNCHECKED TN-C:UNCHECKED TN-R:UNCHECKED County:UNCHECKED PROJECT INFORMATION Site Plan Date (MM/DD/YYYY):11.20.2020 Landscape Plan Date (MM/DD/YYYY):12.02.2020 Elevations Date (MM/DD/YYYY):12.02.2020 Existing Floor Area (If Applicable):20,270 Gross Floor Area Proposed:24343 Number of Standard Parking Spaces Provided:47 In Reclaimed Water Buffer:No QUALIFYING OPEN SPACE Open Grassy Area (min. 50' x 100'):UNCHECKED Community Garden:UNCHECKED Ponds or Water Features:UNCHECKED Plaza:UNCHECKED Additions to Public Park:UNCHECKED Collector Street Buffer:UNCHECKED Arterial Street Buffer:UNCHECKED 8' or 6' Wide Parkways:UNCHECKED 10' Parkway Along Arterials:UNCHECKED Stormwater Detention Facility:UNCHECKED QUALIFYING SITE AMENITIES Clubhouse:UNCHECKED Fitness Facilities:UNCHECKED Enclosed Bike Storage:UNCHECKED Public Art:UNCHECKED Picnic Area:UNCHECKED Additional 5% Open Space:UNCHECKED Communication Infrastructure:UNCHECKED Dog Owner Facilities:UNCHECKED Neighborhood Business Center:UNCHECKED 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 5 Swimming Pool:UNCHECKED Children's Play Structure:UNCHECKED Sports Courts:UNCHECKED Pedestrian or Bicycle Circulation System:UNCHECKED Transit Stop:UNCHECKED Park and Ride Lot:UNCHECKED Walking Trails:UNCHECKED APPLICATION DISCLAIMER I have read and accept the above terms:CHECKED Your signature:Josh Shiverick 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 7 cushingterrell.com December 2, 2020 City of Meridian Planning and Zoning Department 33 East Broadway Avenue, Suite 102 Meridian, Idaho, 83642 Dear Sir or Madam, As an authorized agent of H.O.T. 1 LLLP, Cushing Terrell is hereby submitting CZC & Design Review documents for an addition to the existing oil storage facility located 501 North Eagle Rd., Meridian, Idaho. The project lot is currently zoned I-L/L-0 and the proposed improvements are an allowable use. The property is well suited for the proposed facility. The new site improvements to the existing property will maintain and enhance the already matured landscape in this area of Meridian. The addition will add approximately 24,300 square feet to the current oil storage facility. The overall site plan and building layout enhance the area and coincide with the surrounding developments. This narrative completes our formal Certificate of Zoning Compliance & Design Review application submittal. Please provide a written response and/or approval at your earliest convenience. If you have any questions, please do not hesitate to contact me. Sincerely, Josh Hersel, Architect | Associate cc: Cushing Terrell R/W R/W R/WR/W1IVIVIVIVIVIVIVIVIVIVIVIVFLFLFLFLFLFLFLFLOHP UGPUGP UGPUGPUGPUGPUGPUGP UGPUGPUGPUGPUGPUGPUGPUGPUGP EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EG EGEP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP WW 12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W12''W FLFLFL TTTTTTTTTTTTTT TTTTTTTTTTTTTTTT T T T T T T T T T T T T T T T T T T T TTTTTTTTTTTTTTTTTTTTTTT UGPUGP UGP UGP UGP UGP UGPUGPUGPUGPUGP UGP UGPUGPUGP UGP 8''W8''W8''W8''W8''W8''W8''W8''W 8''W8''W 6''W W 8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS8''SS 8''SS 8''SS 8''SS 8''SS 8''SSGIRRGIRRGIRRGIRRGIRRGIRR GIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRR/W 4''SS 4''SS4''SS4''SSSS SS SS SSSSGIRR GIRRSDSD SDSDSD SD SD SD SD SD SD SDSDMWMWMWADRDRDDGGGGGGGMTRTTTTSSSSIRRIRRIRR26272626262626272628262726282630 2631 2 6 2 6 2626 2628262926 2 9 26 3 0 2 6 3 0 263226302629 2630 2629 2 6 2 8 2629 26302627 2627262826272628 2626262526252624 2625262626262627262826292630 2631 2632 2632 26302631 2632 2633SSMHRIM:2624.758"PVC IE-NTH:2618.526"PVC IE SE/SW:2618.90SSMHRIM:2626.648"PVC IE-STH:2612.1912"PVC IE EST:2612.1212"PVC IE WST:2612.02SSMHRIM:2628.288"PVC IE-STH:2612.7312"PVC IE EST:2612.5812"PVC IE WST:2612.47UNABLE TOLOCATE STUBFF:2627.84FF:2627.81FF:2627.76FF:2627.78FF:2627.79FF:2628.28METAL STEPSTRASHENCLOSURECONCRETERAISED CURBWALLROCK WALLN01°28'12"E 2650.18'N88°29'23"W 70.00'S88°29'18"E 730.12'N88°29'18"W 787.45'S69°05'00"E 60.47'S01°28'12"W 429.84'N01°28'12"E 2650.18'VALLEY GUTTERVALLEY GUTTERSSCOTBM-1SCRIBED "X"ELEV:2626.31'TBM-25/8" REBAR W/CAPELEV:2627.16'6''W6''W6''W6''W6''W6''WSDCBGRT:2624.216"PVC IE-NTH:2623.26SDCBGRT:2624.0612"PVC IE-SW:2620.0412"PVC IE-SE:2619.86SDMHRIM:2625.5212"PVC IE-NW:2619.3712"PVC IE-STH:2619.94SDCBGRT:2624.1012"PVC IE-NE:2620.27SDCBGRT:2627.6212"PVC IE-NTH:2621.946"PVC IE-EST:2625.1012"PVC IE-STH:2622.42SDCBGRT:2625.5912"PVC IE-NW:2622.54TRENCH DRAINTRENCH DRAINWVWVWVWVWVWVWVWVWVWMTRWVWVBOLBOLBOLBOLBOLBOLBOLBOLBOLBOLBOLBOLEEEEEEEEEEEEEEEMTRIBXRIM:2626.315"RCP IE-WST:2624.015"RCP IE-EST:2624.115'RCP IE-NTH:2622.7IBXRIM:2626.315"RCP IE-WST:2624.015"RCP IE-EST:2624.115'RCP IE-NTH:2622.7IBXRIM:2631.615"RCP IE-WST:2623.515"RCP IE-EST:2625.215'RCP IE-NTH:2622.726 2 7 2 6 2 8 50' INGRESS/EGRESS EASEMENTINST.No.7640090 70' WATER, UTILITY & ROAD EASEMENTINST.No.100017941 35' LANDSCAPEBUFFER25' IPCo EASEMENTINST.No.11101155520' PATHWAY EASEMENT'INST.No.11208227220' EASEMENT PROHIBIT BUILDINGSOR STRUCTURES10'IR R I G A T I O N E A S E M E N T INST. N o . 8 8 4 6 0 3 6 20' IP C o 2629APPROX. FF: 2627.8AT DOCK DOOR8' 42' 20.83 ' 30.76'45'18'90'9'9'9'1268.07'85.21'20.41'R50'5.5'6'6'9.7'33319'422.3'56.5'11' 19'6.5'11'627'17'53.4'53.65'129.87' 129.9' 70.03' 69.99'EXISTINGBUILDINGPROPOSEDBUILDINGEXPANSIONUNION PACIFIC RAILROADN. EAGLE RD.E. COMMERCIAL ST.60'70.67'16.97'25.29'32.71'15.46'R5'R5 '17'MATCHEX CURBMATCHEX CURBNEW CONCRETE AREA FORTRUCK LOADING ZONEMATCHEX CURBMATCHEX CURBCONTINUE WALKTO EX PATHEXISTINGPARKING TOREMAINDRAWN BY |REVISIONS©| ALL RIGHTS RESERVEDCHECKED BY |®SCENTSY OIL STORAGE ADDITION H.O.T. 1 LLLPCZC SUBMITTALSET11-20-2020NOT FOR CONSTRUCTION - PERMIT SET 2020TLG PN:120156.00CONSTRUCTIONNOT FORTLGJCD1.REVISIONSSITE LAYOUTC100Horizontal Scale: 020'40'1" = 20'CZC Site LayoutKeynotes:Project Information:OWNER:H.O.T1, LLCCONTACT: SAM JOHNSON2701 E. PINE AVE.MERIDIAN, IDAHO 83642(208) 863-5889ARCHITECT:CUSHING TERRELLCONTACT: JOSHUA HERSEL800 W. MAIN ST., STE. 800BOISE, IDAHO 83702(800) 757-9522CIVIL ENGINEER: THE LAND GROUP, INC.CONTACT: JASON DENSMER, PE462 E. SHORE DR., SUITE 100EAGLE, IDAHO 83616(208) 939-4041LANDSCAPE ARCHITECT: CUSHING TERRELLCONTACT: ANGELA HANSEN800 W. MAIN ST., STE. 800BOISE, IDAHO 83702(800) 757-95221. ADA ACCESSIBLE PARKING. PAVEMENT MARKINGS AND SIGNAGE PER ADAREQUIREMENTS.2. PEDESTRIAN RAMP3. LANDSCAPE AREA. SEE LANDSCAPE PLAN FOR DETAILS.4. PROTECT EXISTING FIRE HYDRANT. INSTALL (2) BOLLARDS.5. CONCRETE TRUCK LOADING DOCK WALL WITH "RUB CURB"6. TRENCH DRAIN7. BIKE RACK PER DETAIL THIS SHEET. CAPACITY OF (2) BIKES PER RACKProject Metrics:#PROPERTY SIZE:PARCEL TOTAL:353,657-SF / 8.12-ACBUILDING SIZE: EXISTING20,270-SF PROPOSED EXPANSION24,343-SF TOTAL44,613-SFREQUIRED PARKING:23-EA(1-SPACE PER 2,000-SF OF GROSS FLOOR AREA PER U.D.C. 11-3C-6.B.2)PARKING SPACES PROVIDED:STANDARD SPACES 45-EAADA ACCESSIBLE SPACES 2-EACOMPACT SPACES0-EATOTAL47-EAREQUIRED BICYCLE PARKING:(1-SPACE PER 25 PROVIDED VEHICLE SPACES PER U.D.C. 11-3C-6.G)VEHICULAR PARKING 47-EARATIO1 PER 25REQUIRED BICYCLE SPACES 2-EABICYCLE SPACES PROVIDED 2-EAZoning Regulations:EXISTING PROPERTY ZONING:I-L (LIGHT INDUSTRIAL) & L-O (LIMITED OFFICE)DIMENSIONAL STANDARDS PER U.D.C. 11-2C-3 FOR I-L:FRONT SETBACK:0-FTREAR SETBACK:0-FTINTERIOR SIDE SETBACK: 0-FTSTREET SETBACK:35-FTLANDSCAPE BUFFERS:STREET:35-FT FROM N. EAGLE RD.10-FT FROM E. COMMERCIAL ST. (LOCAL)RESIDENTIAL USES:25-FTMAXIMUM BUILDING HEIGHT: 50-FTDIMENSIONAL STANDARDS PER U.D.C. 11-2C-3 FOR L-O:FRONT SETBACK:0-FTREAR SETBACK:0-FTINTERIOR SIDE SETBACK: 0-FTLANDSCAPE BUFFERS:STREET:35-FT FROM N. EAGLE RD.10-FT FROM E. COMMERCIAL ST. (LOCAL)MAXIMUM BUILDING HEIGHT: 35-FT 12" 6"6"1. HOOP RACK BY DERO.2. FINISH/COLOR TO BE POWDERCOATED BLACK3. SPACING REQUIREMENTS PER MANUFACTURER'S SPECIFICATIONS.4. INSTALLATION PER MANUFACTURER'S SPECIFICATIONS.NOTES:CORE DRILL 4" DIA. x 6" DEEP.FILL HOLES WITH HIGH STRENGTH 2PART EPOXY GROUT.4"CONCRETE FLATWORK PER PLANS3'4" DEPTH OF CRUSHEDAGGREGATE BASE COURSEPER ISPWC SECTION-8000Scale: NTSBike Rack 1