PZ - Site Utility Plan Sheet Notes: gxl .2 _ 0i= T H E .9 "W 12"W 12"Vk 12"W 12"W 12"W 12"W 1. THE CONTRACTOR SHALL BRING ANY CONFLICTS TO THE ATTENTION OF THE LAND2 7 1 12"W PROJECT ENGINEER PRIOR TO PROCEEDING WITH THE WORK. . E N 2. THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN - GROUp PROGRESS APPROXIMATE WAY ONLY.THE CONTRACTOR SHALL COMPLY WITH IDAHO TLG PN1120123 o SET CODE CHAPTER 22,TITLE 55 REGARDING UNDERGROUND FACILITIES DAMAGE w PREVENTION.THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF N ALL EXISTING UTILITIES BEFORE COMMENCING WORK.THE CONTRACTOR E. VILLAGE DRIVE (PUBLIC) AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED AS A RESULT OF FAILURE TO EXACTLY LOCATE AND S PRESERVE ANY AND ALL UTILITIES.THE CONTRACTOR SHALL CONTACT THE 8"SS 8"SS 8"SS 8"SS 81ISS APPROPRIATE UTILITY COMPANIES OR DIG-LINE (342-1585) FOR EXACT .2 PRINTED DATE o LOCATIONS A MINIMUM OF 48-HOURS PRIOR TO DIGGING.Cn o �' T 12.10.2020 "' 3. HORIZONTAL LAY LENGTHS OF MAIN LINES AND SERVICES ARE SHOWN FOR N - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - REFERENCE ONLY AND MAY VARY FROM ACTUAL INSTALLED LENGTH. U mw 3 4. ALL PIPE INSTALLATION AND TRENCHING SHALL CONFORM TO THE LATEST a °C D SD SD - - - - EDITION OF THE ISPWC DIVISION 300 AND SD-301. BEDDING AND BACKFILL N 2 D D D D SD SHALL BE CONSTRUCTED PER SECTIONS 305 AND 306 OF THE ISPWC.THRUST o BLOCKING SHALL BE CONSTRUCTED PER ISPWC SD-403. s - - _ 1 _ 6 _ - - APPROX. IE:2621.87 11-LF 6-IN C900 _ _ _ _ _ UG 7 �1 =92-LF OF 4-IN PVC AT 2.00% JJG� - - - " °- - - - - - - - 5. FINAL CONNECTION TO CIVIL/UTILITY/SITE SYSTEMS ARE BY BUILDING r inn ri �1RR UG Uf 5 7 �I �IRFi �IRR - - FT - �iRF� - N O - - - - - - - - - - CONTRACTOR. SITE CONTRACTOR WILL BRING PIPING TO 5'-0"OF BUILDING w O / W",R 2 (EXCEPT AS SPECIFICALLY NOTED OTHERWISE). m N G G G G G IE: 2622.10 �F I � 0 I N a� E 3 SO, OF4,11V 1 I 6. ALL WATER MAIN LINES SHALL BE ANSI/AWWA C900 OR C909 CLASS 150, x o p�C I DR18 PVC. o ui 0 I ® TR AT2��� � � 1 ;)�- � l t � ® \ 7. ALL WATER SERVICE LINES SHALL BE ANSI/AWWA C901 CLASS 150, DR7 E 0 °� 125-LF OF 4-IN PVC AT 2.00% 3 O \ POLYETHYLENE (PE) OR ANSI/AWWA C900 CLASS 150, DR18 PVC WHERE C 2 NOTED. oo O I o 4 IE: 2625.93 2 ca Cn ; \ . 4-IN PVC I I I o 4 IE: 2623.72 IE: 2623.11 O \ 8. BOTH DOMESTIC AND FIRE SERVICE LINES REQUIRE A BACKFLOW PREVENTION \\ DEVICE AT THE POINT OF ENTRY TO ANY BUILDING.THE TYPE OF DEVICE IS m . IE: 2623.44 I CONTINGENT UPON THE DEGREE OF HAZARD. T ° c E I Sewer Keynotes: �� o Y 3 C 3 4 I I 1. CONNECT TO EXISTING SANITARY SEWER STUB. CONTRACTOR SHALL VERIFY 0Li - I I SUITABILITY OF CONNECTION PRIOR TO CONSTRUCTION AND CONFIRM SLOPES Lo ARE ACHIEVABLE. BRING ANY DISCREPANCIES TO ENGINEER. I J1mII O L-C) Y� C I II ICn o 2. INSTALL 2500-GALLON GREASE INTERCEPTOR PER MECHANICAL PLAN. N o I o mw 3. INSTALL STANDARD 4-IN CLEAN-OUT PER ISPWC SD-506A. W ® ° i 4. COORDINATE WITH BUILDING MECHANICAL FOR CONTINUATION INTO BUILDING. E Q 12�SD 12 SD I Water Keynotes: �0 0 �- IFF2628.20 o D SD SD SO SD SD I 1. CONNECT TO EXISTING WATER METER, CONFIRM SUITABILITY OF CONNECTION N PRIOR TO COMMENCING CONSTRUCTION, BRING ANY DISCREPANCIES TO O ® I ENGINEER. Imo_ 7 8 I 2. INSTALL FIRE HYDRANT PER CITY OF MERIDIAN STANDARD DRAWING W8. 00 CIO J 3. CONNECT TO EXISTING HYDRANT LATERAL, PROVIDE AND INSTALL FITTINGS IV 4 I AS REQUIRED. C( C �iI IV El 4. COORDINATE WITH BUILDING MECHANICAL FOR CONTINUATION INTO BUILDING. 0 ui 2 5. MAINTAIN HORIZONTAL AND VERTICAL SEPARATION OF POTABLE AND o 00 NON-POTABLE WATER LINES PER ISPWC SD-407 AND CITY OF MERIDIAN I a I 0 STANDARD WATER NOTE NO. 3, REFER TO SHEET C0.00. IF SEPARATION IS NOT ACHIEVABLE, SLEEVE FIRE SERVICE AND DOMESTIC SERVICE LINES PER CITY J OF MERIDIAN SD SW1 &SW2 CIO J z _ I / z Q C ;0 ■� ■ I // 6. CONNECT TO EXISTING WATER STUB FOR FIRE SERVICE CONNECTION. W COORDINATE PIPE SIZE WITH FIRE SPRINKLER CONTRACTOR. Ill Q / o CIOo ■ // 7. INSTALL X"90'BEND AND THRUST BLOCK PER ISPWC SD-403. J W ' ® / 8. COORDINATE WITH BUILDING MECHANICAL FOR CONTINUATION AND FIRE a M /I SPRINKLER CONTRACTOR FOR FIRE SERVICE SIZING.I I � 9. INSTALL BUILDING-MOUNTED FIRE DEPARTMENT CONNECTION. COORDINATE 2 I WITH BUILDING MECHANICAL AND FIRE SPRINKLER DESIGNER FOR o I ;aa REQUIREMENTS. ° I - - I Dry Utility Keynotes: 2"SD 12"SD D D 1. EXISTING ELECTRICAL TRANSFORMER LOCATION. COORDINATE ELECTRICAL F ROUTING WITH IDAHO POWER AND SITE ELECTRICAL PLAN. ` I I + I N CHRONOLOGY ° I 2. SITE LUMINAIRE. SEE ELECTRICAL PLANS FOR MORE INFORMATION. U r CL _ ° I `" 3. GAS METER PACK. COORDINATE WITH BUILDING MECHANICAL AND INTERMOUNTAIN GAS FOR MORE INFORMATION. N 0 ° I 4. CONNECT TO EXISTING GAS STUB, SERVICE PIPE ROUTING SHOWN ONLY a ° I o CONCEPTUALLY. COORDINATE WITH BUILDING MECHANICAL AND o "' INTERMOUNTAIN GAS FOR MATERIAL, SIZING AND CONSTRUCTION OF PIPE. 0 ° I .a 0 - IV IV o I m Aw E IV I II I L - - - - - - - - - - - - - - -- - - J L - J Mw �V (2)0 U Q N I N o C PROJECT NO o 20.036 N I I I y DWN BY/ CHK BY Lp I � V = CR / JD I I N LD II ° LDTITLE I I I CUP CD C SITE UTILITY PLAN a ° y N 24X36 SHEET # CUP - Conce tual En ineerin Plan p g g o 20 40 3 C5.00 Horizontal Scale: 1" = 20'