Loading...
ACHD Transmittal (A-2020-0204)Applicant name:HELEN UBIC, U SPACE Phone: Applicant address:1310 N. 23RD ST, BOISE, ID 83702 Email:hubic@uspacearch.com Owner name:WARREN WILLIS, WELLPOINT DENTAL Phone:Fax: Owner address:2655 SANDHILL LANE, EMMETT, ID 83617 Email:warrenwillis73@outlook.com Administrative Applicant Information Type of Review Requested File number:A-2020-0204 Assigned Planner:Cameron Scott Related Files: Subject Property Information Location/street address:2750 W CHERRY LN Assessor's parcel number(s):R5399960030 Township, range, section:3N1W2 Agent name (e.g. architect, engineer, developer, representative):HELEN UBIC Firm name:Phone:Fax: Address:1108 N 7TH ST Email:hubic@uspacearch.com Contact name:Phone:Fax: Contact address:Email: Project/Application Name:Wellpoint Dental - DES, CZC Description of Work:Uploading a narrative letter. Project Description Planning Division ADMINISTRATIVE APPLICATION 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 1 APPLICATION TYPES Alternative Compliance - ALT:UNCHECKED Certificate of Zoning Compliance - CZC:CHECKED Does project have prior approval?:No Does your project contain new construction and/or modifications to an existing building or the site?: Yes Design Review - DES:CHECKED Private Street - PS:UNCHECKED Vacation - VAC:UNCHECKED ADDRESS VERIFICATION Address Verification Permit Number:LDAV-2020-0657 TYPE OF USE PROPOSED Residential:UNCHECKED Office:CHECKED Commercial:UNCHECKED Employment:UNCHECKED Industrial:UNCHECKED Single-Family Detached:UNCHECKED Single-Family Attached:UNCHECKED Townhouse:UNCHECKED Duplex:UNCHECKED Multi-Family:UNCHECKED Vertically Integrated:UNCHECKED PROPERTY INFORMATION General Location:2750 Cherry Lane. Meridian Current Land Use:vacant Total Acreage:0.6 Prior Approvals (File Numbers):n/a ZONING DISTRICT(S) R-2:UNCHECKED R-4:UNCHECKED R-8:UNCHECKED R-15:UNCHECKED R-40:UNCHECKED C-N:UNCHECKED C-C:UNCHECKED C-G:UNCHECKED L-O:CHECKED M-E:UNCHECKED Application Information 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 3 H-E:UNCHECKED I-L:UNCHECKED I-H:UNCHECKED O-T:UNCHECKED TN-C:UNCHECKED TN-R:UNCHECKED County:UNCHECKED PROJECT INFORMATION Site Plan Date (MM/DD/YYYY):10/20/2020 Landscape Plan Date (MM/DD/YYYY):10/20/2020 Elevations Date (MM/DD/YYYY):10/20/2020 Percentage of Site Devoted to Building:12.4 Percentage of Site Devoted to Landscaping:22.6 Percentage of Site Devoted to Paving:64.1 Who will own and Maintain the Pressurized Irrigation System in this Development:Building Owner Irrigation District:Nampa and Meridian district. Boise Project Board of Control Primary Irrigation Source:Nanpa and Boise Irrigation District Square Footage of Landscaped Areas to be Irrigated by City Water Connection:None Proposed Building Height:20'-2" Existing Floor Area (If Applicable):N/A Gross Floor Area Proposed:3420 Number of Standard Parking Spaces Provided:17 Number of Compact Parking Spaces Provided:0 Number of Employees:4 Number of Residential Units:0 Minimum Square Footage of Living Area (Excluding Garage):0 Gross Density:0 Net Density:0 In Reclaimed Water Buffer:No QUALIFYING OPEN SPACE Open Grassy Area (min. 50' x 100'):UNCHECKED Community Garden:UNCHECKED Ponds or Water Features:UNCHECKED Plaza:UNCHECKED Additions to Public Park:UNCHECKED Collector Street Buffer:UNCHECKED Arterial Street Buffer:UNCHECKED 8' or 6' Wide Parkways:UNCHECKED 10' Parkway Along Arterials:UNCHECKED Stormwater Detention Facility:UNCHECKED 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 5 QUALIFYING SITE AMENITIES Clubhouse:UNCHECKED Fitness Facilities:UNCHECKED Enclosed Bike Storage:UNCHECKED Public Art:UNCHECKED Picnic Area:UNCHECKED Additional 5% Open Space:UNCHECKED Communication Infrastructure:UNCHECKED Dog Owner Facilities:UNCHECKED Neighborhood Business Center:UNCHECKED Swimming Pool:UNCHECKED Children's Play Structure:UNCHECKED Sports Courts:UNCHECKED Pedestrian or Bicycle Circulation System:UNCHECKED Transit Stop:UNCHECKED Park and Ride Lot:UNCHECKED Walking Trails:UNCHECKED APPLICATION DISCLAIMER I have read and accept the above terms:CHECKED Your signature:Helen Ubic 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 7 U space architecture LLC. european inspired, environmentally responsible design 1108 N 7th St, Boise, Idaho 83702 hubic@UspaceArch.com 1 208 577 0869 Narrative letter for Certificate of Zoning Compliance Application. 1108 N 7th St, Boise ID 83702, (208) 577 0869, hubic@UspaceArch.com 26th Oct, 2020 Caleb Hood Planning Division Manager City of Meridian, Planning and Zoning Department 33 E Broadway Ave, Suite 102, Meridian, ID 83642 RE: Wellpoint Dental, Office Building, 2750 Cherry Lane, Meridian, Idaho Dear Caleb, The applicant, Ben Richeson of RNR Custom Homes, requests an Certficate of Zoning Compliance( CZC)for the construction of a 3420 square foot dental office building on 0.6 acres of land in the Lynwood Plaza subdivision, The building pad is in the L-O zoning district and the address is 2750 W. Cherry Lane. The proposed building is the fourth of five buildings situated on building pad #4, Block 1 Lot 3, positioned in the center rear of the development. It would be constructed in compliance with the approved Development Agreement, (File no. MI-03-005) which is referred to in the CZC of the first building dated April 24, 2003. The roof will be constructed of architectural grade asphalt shingles, and the walls will be brick veneer and composite cementitious siding, finished in colors and patterns which will compliment the other buildings in the Cherry Lane Center. Please refer to the Design Review application and the attached elevation drawings for more detail. There is a common ingress and egress easement, in the Center, over the parking area and the utilities are in common easements for use by all five buildings. We hope this project meets with your approval. Should you have any questions please feel free to call or email U Space Architecture to discuss this projectl further. Respectfully yours Helen Ubic, Director of U space architecture LLC, Licensed Architect AR-984851, LEED AP BD+C, Certified Sustainable Building Advisor U space architecture LLC. european inspired, environmentally responsible design 1108 N 7th St, Boise, Idaho 83702 hubic@UspaceArch.com 1 208 577 0869 Narrative Letter for Design Review 1108 N 7th St, Boise ID 83702, (208) 577 0869, hubic@UspaceArch.com 26th Oct, 2020 City of Meridian, Planning and Zoning Department 33 E Broadway Ave, Suite 102, Meridian, ID 83642 RE: Wellpoint Dental, Office Building, 2750 Cherry Lane, Meridian, Idaho Dear Design Review Staff, The applicant, Ben Richeson of RNR Custom Homes, requests an Administrative Design Review for the construction of a 3420 square foot dental office building on 0.6 acres of land in the Cherry Lane Center. The site is located at 2750 W. Cherry Lane. Since the development is in the L-O zoning district the following narrative addresses how the proposed design meets the intents and goals contained in the City of Meridian Architectural Standards Manual and the Unified Development Code (UDC). 1. Architectural Character: a. Cohesive Design The design incorporates architectural features on the façades of the building, facing interior site amenities. It is compatible with existing adjacent land uses and enhances the appeal of the open spaces nearby. b. Building Scale: In general, the design addresses appropriately the issue of building scale in relation to adjacent development. The tower entrance feature accentuates the sense of arrival and helps to frame the public space while incorporating elements that are pedestrian in scale. It relates in height to the adjacent single story built forms. There is consistent incorporation of two architectural features: repeated pattern banding in the vertical siding and fenestration patterns. c. Building Form The building addresses the Architectural Standards Manual’s form intents, keeping in mind the pedestrian nature of the surrounding development. Massing is single story with a hipped pitched roof of mostly 20ft.- 2in. in height. There is appropriately scaled variation in the ridgeline height across the roof. The eaves height articulates at the entry to address the exterior central public circulation space located to the south of the building. The ridge also changes height on the West Elevation to address the building next door. The wall planes project on the West and South Elevations by 1ft. 6in. for stretches of 20ft. or less. Roof eave overhangs are deep, and the façade materials change frequently, to modulate and break up the building mass. Fenestration establishes a visual connection that relates the waiting area to the exterior public spaces. 2 1108 N 7th St, Boise, Idaho 83702 hubic@UspaceArch.com 1 208 577 0869 d. Architectural Elements The design uses proportional architectural elements and detailing to articulate facades. The detailing uses the local vernacular of brickwork and siding patterns, both horizontal and vertical, as well as banding, to emphasis pedestrian scale. The siding, composite asphalt shingles and brick veneer used for the building are the local architectural palette. To enhance the visual interest and support activity near ground level the building has a porch or vestibule. This focal element at the public entry is accented with a change in texture, symmetric entryway lighting and modulation of the walls and roof. e. Materials The design makes use of a variety of materials. The base under the window sill is in red brick veneer which visually anchors the building on the ground and is the accent material. The upper section of the walls is in lapped horizontal composite cementitious fiber board siding (Hardie Board). The neutral grey/taupe field wall color has been selected to reflect contemporary taste and to fit in with the other Medical Office Buildings on the development. The entry way is detailed with vertical batt and board siding. The roof is dark grey architectural asphalt composite shingle which is also in keeping with the other adjacent structures. f. Signs and/or Lighting Energy efficient architectural lighting is associated with predominant architectural features. Lights are located either side of the entrance and at intervals round the rest of the building, as symmetric elements either side of fenestration and entry doors. 2. Parking Lot The parking is already provided in accordance with the Certificate of Zoning Compliance, Oakwood Enterprises LLC on April 24 2003. There are 17 stalls, 1 disabled stall with a loading zone and 2 bicycle stalls by the main entry. 3. Pedestrian walkways and facilities, The building pad is also provided with existing sidewalks according to the Certificate of Zoning Compliance given to Oakwood Enterprises LLC on April 24, 2003. These have been extended to connect with the building at the main entrance and employee entrances. I hope this description meets your requirements. Please feel free to contact U Space Architecture with any further requests for information or comments. Respectfully yours Helen Ubic, Director of U Space architecture LLC, Licensed Architect AR-984851, LEED AP BD+C, Certified Sustainable Building Advisor