L2.01 Irrigation DetailsJOB NO: DATE: DRAWN BY: CHECKED BY: # DRAWING TITLE SHEET NUMBER JB EV/ KS 11.24.2020 19-1429 D e s c r i p t i o nDATEMRK REVISIONSMcCLURE DENTAL LAB1747 S. SPRING VALLEY LANEMERIDIAN, IDAHO 836421 ABCDEFGH2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 STACK ROCK GROUP - BID SETWILLET C HOWARD, PLA OFFICE: (208) 345.0500 EMAIL: WILL@STACKROCKGROUP.COM www.STACKROCKGROUP.COM THE GRAPHICS AND DESIGNS O N T H I S S H E E T A R E DE LIVE RAB LE S THA T RE MA IN A T A L L TI M E S PR OP E R T Y O F S T A C K R O C K G R O U P , I N C . REPRODUCTION OR REUSE OF T H I S P R O D U C T C O N T A I N E D H E R E I N I S P R O H I B I T E D W I T H O U T T H E W R I T T E N C O N S E N T O F S T A C K R O C K G R O U P , I N C . ©2020 STACK ROCK GROUP, INC. LANDSCAPE ARCHITECTURE & MASTER PLANNING (208) 345-0500 404 S 8th St. #154 Boise, ID 83702 StackRockGroup.com PRELIMINARY NOT FOR CONSTRUCTION L2.01 IRRIGATION DETAILS TRENCH SECTION DETAIL 3" = 1'-0" MAINLINE TAPE CONTROLLER WIRE TO MAINLINE @ 10' o.c.. 2" OF SAND OR FINE SOIL ALL AROUND PIPES. ROCK FREE BACKFILL LATERAL LINE FINISH GRADE 1'-0"6"NOTE: GLUE ALL PIPE & FITTINGS PER MANUFACTURE REQUIREMENTS 1 328409.76-21 DEPTH AS PER SPECIFICATIONSWIDTH VARIES 4"MINFINISH GRADE NATIVE SOIL BACKFILL COMPACT TO 95% COMPACTION PVC MAIN LINE BACKFILL WITH 100% CLEAN FILL. MECHANICALLY COMPACT TO 95% COMPACTION. ALLOW 48 HOURS TO SETTLE, AND COMPACT WITH NATIVE SOIL. 4" MIN. BEDDING 4" MIN.4" MIN. SLEEVE AT ROAD 1 1/2" = 1'-0" NOTE: SLEEVES MUST BE 2X THE PIPE SIZE 2 328409.76-22 3/4"-1 1/4" POINT OF CONNECTION 1" = 1'-0" BUCKNER BRASS ANGLE VALVE. SIZE PER IRRIGATION PLAN 2" LONG BRASS NIPPLE. BRASS REDUCING TEE PLACED ON IT'S SIDE WITH 3 4" BRASS CROSS HANDLE GATE VALVE. THREADED SCH. 80 NIPP TO EXTEND OUT OF 10" PIPE A MINIMUM OF 6". SOLVENT WELD SCH. 40 90 DEG ELL. TO BACKFLOW DEVICE WATER SERVICE LINE PROVIDED BY OTHERS. VERIFY SIZE ON SITE. STAINLESS STEEL HOSE CLAMPS. VERIFY SIZE BASED ON WATER LINE DIMENSION. ALTERNATE DIRECTION OF CLAMP. (2) ON EACH SIDE OF TEE. 3"X8" MASONRY BRICK OVER COMPACTED BASE. 3 TOTAL. BRASS INSERT TEE UP TO 1 1 4" IN SIZE. LARGER SIZES MAY UTILIZE DIFFERENT FITTINGS. 10" ROUND RIGID PLASTIC VALVE BOX 10" PVC PIPE 160 PSI MIN. EXTEND 4" BELOW WATER LINE. 36" MIN. FINISH GRADE COMPACTED BACKFILL TO 90% PROCTOR. WATER SETTLE AND LET SIT FOR 48 HOURS BEFORE RESTORING. COMPACTED SUBGRADE NOTES: 1.CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS, INSPECTIONS, AND FEES. 2.NOTCH 10" PVC 1 2" MIN. LARGER THAN ALL PIPES ENTERING AND LEAVING SLEEVE. AT NO TIME SHALL 10" PIPE TOUCH WATERLINE OR SERVICE LINE TO BACKFLOW. 4" DEPTH CRUSHED 3 4" WASHED GRAVEL. 2" BELOW ALL FITTINGS.4"3 328409.73-02 COVER SIZE + 6" RP BACKFLOW W/ ENCLOSURE 1" = 1'-0" REDUCED PRESSURE BACKFLOW DEVICE AS SPECIFIED. BACKFLOW COVER AS SPECIFIED. GALVANIZED NIPPLES AND ELL AS REQUIRED. GALVANIZED UNIONS AT EACH SIDE. GALVANIZED RISERS. 4" THICK MIN. CONCRETE PAD. GALVANIZED ELL AND NIPPLE, TYPICAL. PVC COUPLER OR REDUCER AS REQ., TYP. MAIN LINE, SIZE AS PER PLANS.CONCRETE THRUST BLOCKS, 90 LBS OF CONCRETE EACH. SERVICE SIDE. LENGTH AND WIDTHHEIGHT ASPER LOCALCODE.3 4" WINTERIZATION PORT. 4 32 8409.46-03 1 1/2" = 1'-0" NO KINK HOSE BIB VALVE IN BOX PVC MALE ADAPTER. GALVANIZED RISER AND ELBOW, HOSE BIB INLET SIZE. MAIN LINE. 60 LB. CONCRETE TORQUE 1/2" WIRE CLOTH GOPHER SCREEN, WRAP UP SIDES. FOUR COMMON BRICKS AS SUPPORT UNDER BOX. BLOCK. 10" DIAMETER VALVE BOX. FINISHED GRADE. NO KINK HOSE BIB AS SPECIFIED. FLUSH TO GRADE AT TURF. 1" ABOVE GRADE AT SHRUBS.2" CLR328406.46-07 5 PVC MAINLINE. DRIPLINE SPACING AS NOTED. AIR/VACUUM RELIEF VALVE PLUMBED TO TECLINE AT EACH HIGH POINT. A CENTER FEED EXAMPLE A END FEED EXAMPLE F LINE FLUSHING VALVE PLUMBED TO PVC OR POLY LINE AT LOW END, AS NOTED. TYPICAL TECHLINE TUBING LATERALS WITH EMITTER SPACING AS NOTED. TIE DOWN STAKE AT ALL TEES, ELLS, AND AT 5' O.C. AT CLAY, 4' O.C. AT LOAM, OR 3' O.C. AT SAND. DRIP VALVE / FILTER / REGULATOR. 12" POLYETHYLENE OR PVC HEADER. TYPICAL OFFSET 2" FROM HARDSCAPE, 4" FROM PLANTED AREA. TYPICAL START CONNECTION SXSXT TEE W/ TECHLINE MALE ADAPTER. TYPICAL LATERAL PIPE FROM VALVE ASSEMBLY, SIZE PER PLANS. BLANK TECHLINE TUBING CENTERED ON MOUND OR BERM. F 1.DRIPLINE LATERALS SHOULD FOLLOW THE CONTOURS OF THE SLOPE WHENEVER POSSIBLE. 2.INSTALL AIR RELIEF VALVE AT HIGHEST POINT. 3.TECHLINE NORMAL SPACING WITHIN THE TOP 2 3 OF SLOPE, 4.INSTALL TECHLINE AT NORMAL SPACING PLUS 25% AT THE BOTTOM 13 OF THE SLOPE. 5.WHEN ELEVATION CHANGE IS 10 FT OR MORE, ZONE THE BOTTOM 13 ON A SEPARATE VALVE. SLOPED CONDITION NOTES:TYPICAL OFFSET 2" FROM HARDSCAPE, 4" FROM PLANTED AREA. WATER SOURCE: DRIP VALVE OR LATERAL FROM VALVE. TYPICAL SUPPLY HEADER. IN-LINE SPRING CHECK VALVE FOR LOW HEAD DRAINAGE. TYPICAL TECHLINE DRIPPER LINE TUBING. TYPICAL PVC OR POLY SUPPLY OR EXHAUST HEADER. F LINE FLUSING VALVE PLUMBED TO PVC OR POLY. A AIR/VACUUM RELIEF VALVE, INSTALL AT HIGH POINT OF SYSTEM. F F F A A A A F FSLOPE 3%+LAYOUT ISLAND DOWN SLOPE - 1 MEDIAN ISLAND,SLOPE 3%+F F A DOWN SLOPE - 2 MEDIAN ISLAND, A F TRIANGULAR IRREGULAR AREAS: F A ODD CURVES IRREGULAR AREAS: A A F F TOTAL LENGTH OF TECHLINE TUBING IN THIS AREA CAN NOT EXCEED THE MAX. LENGTH OF RUN. TYPICAL START CONNECTION ON EXHAUST HEADER. TYPICAL START CONNECTION ON SUPPLY HEADER. SEE SUB-HEADER DETAIL. TYPICAL TECHLINE START CONNECTION. PARKING ISLAND TYPICAL LAYOUT DRIPPER SPACING 12"18"24" DRIPPER FLOW 0.4 0.6 0.9 0.4 0.6 0.9 0.6 0.9 RATE (GPH) 15 292 233 175 410 322 247 405 308 25 397 321 238 558 438 335 553 423 35 486 365 279 656 514 394 649 497 45 520 407 311 732 574 439 725 555 TECHLINE MAXIMUM LENGTH OF SINGLE LATERAL (FT)INLET PRESSURE(PSI) 0.4 GPH DRIPPER 0.6 GPH DRIPPER 0.9 GPH DRIPPER GPH GPM GPH GPM GPH GPM 12"40.00 0.67 61.00 1.02 92.00 1.53 18"26.67 0.44 41.00 0.68 61.00 1.02 24"N/A N/A 31.00 0.51 46.00 0.77 DRIPPER SPACING TECHLINE FLOW PER 100 FEET TYPICAL NETAFIM TECHLINE REQUIREMENTS 3" = 1'-0" EXAMPLES LEGEND BURY DRIP 2" BELOW FINISH GRADE. INSTALL MULCH PER PLANS. 2" MULCH AS SPECIFIED VERY IMPORTANT *** 6 32 8413.56-09 9 8 4 7 6 5 8 2 4 3 1 9 DRIP ZONE KIT MODEL ICZ-101-XX WITH FILTER (TIP 45 DEGREES) REGULATOR 25 OR 40 PSI 2 1 5 3 6 7 6 HUNTER ICZ DRIP CONTROL ZONE 1 1/2" = 1'-0" FINISHED GRADE JUMBO VALVE BOX WATERPROOF CONNECTORS(2) 18-24" COILED WIRE SCH 80 T.O.E. NIPPLE MAIN LINE PIPE & FITTINGS BRICK SUPPORTS (4) 3 4" MINUS WASHED GRAVEL 7 328413.76-31 1 1/2" = 1'-0" DRIP FLUSH CAP ASSEMBLY 10" DIAMETER VALVE BOX. COIL 18" TO 24" OF DRIP TUBING IN THE BOX. REMOVABLE FLUSH CAP. ABOVE GRADE 12" DRIP TUBING.2"SET VALVE BOX 2" ABOVE FINISHED GRADE OF SHRUB AREA. 4" THICK LAYER OF WASHED GRAVEL. THE BOX SHALL REST UPON THE ROCK BED. DO NOT EXTEND GRAVEL INTO BOX. DRIP TUBING COUPLING. 1.LOCATE FLASH CAP ASSEMBLY AT THE END OF EACH DRIP LINE. 2.ENSURE THAT THE COILED DRIP TUBING IS OF SUFFICIENT LENGTH TO COMPLETELY EXTEND OUT OF THE VALVE BOX WHEN FLUSHING. FX-IR-FX-DRIP-04 8 1" = 1'-0" WALL MOUNT CONTROLLER RCV WIRES. 1 1/2" DIAMETER RIGID STEEL CONDUIT FOR BELOW GRADE. USE PVC SCH. 40 TO WALL. INSTALL BACKUP BATTERIES AS REQUIRED. GROUND AS PER MFG. SPECIFICATIONS. 1/2" DIAMETER RIGID STEEL CONDUIT FOR 110 VAC ELECTRICAL SOURCE. INSTALL AS SET CONTROLLER 60" ABOVE FINISHED GRADE UNLESS OTHERWISE NOTED. CONTROLLER AS SPECIFIED. SECURELY BOLT CONTROLLER CODES. FINISHED GRADE. LONG SWEEP ELL. PER LOCAL ELECTRICAL FX-IR-FX-CONT-07 9 7 2 6 3 1 1 4 5 2 6 45 7 3 UP TO 800' AWAY HUNTER PRO-C CONTROLLER WIRELESS SOLAR SYNC RECEIVER MOUNTED ON THE WALL NEXT TO THE CONTROLLER SUITABLE POST, POLE, OR GUTTER MOUNT. MOUNT IN LOCATION WHERE SENSOR CAN RECEIVE FULL SUN, IS OPEN TO RAINFALL AND OUT OF SPRINKLER SPRAY PATTERN MODEL: WIRELESS SOLAR SYNC SENSOR. MOUNT UP TO 800' FROM RECEIVER VALVE CONTROL WIRE CONDUIT MODEL: SOLAR SYNC MODULE MOUNT LESS THAN 6' AWAY FROM CONTROLLER WIRELESS SOLAR SYNC SYSTEM 1" = 1'-0" POWER SOURCE 328409.33-03 10