Texture paint Data and examples116.17
ConFlex® UltraCrete™
Acrylic Texture Coating
CF17W0801 Fine Extra White, CF17W0811 Medium Extra White
CF17W0821 Extra Coarse Extra White
CHARACTERISTICS
ConFlex™ UltraCrete™ Acrylic Textured Coating is an 100% acrylic aggregate-filled coating used to produce a textured finish on properly prepared interior or exterior surfaces. The pleasing texture that results has the ability to minimize defects and irregularities found on poured cement aggregate block and sheetrock joints. The excellent adhesion of the product makes this suitable for side walls, as well as for ceilings. May be used on concrete, aggregate block, sheetrock, cement, primed steel, and primed wood.
Color:Many Colors
Coverage:
Textured 50-80 sq.ft. per
gallon per coat
Coverage will vary with the substrate and the texture.
Drying Schedule, 50% RH:
@ 77°F
Touch:30 minutes to 1 hour
Recoat:2 hours
Drying time is temperature, humidity and film thickness dependent.
Finish:Low Eg-Shel
Tinting with CCE:
Base oz. per gallon Strength
Extra White 0-6 SherColor
Extra White Fine CF17W0801
(may vary by product)
V.O.C. (less exempt solvents):
less than 50 grams per litre; 0.42 lbs. per gallon
As per 40 CFR 59.406
Volume Solids:41 ± 2%
Weight Solids:54 ± 2%
Weight per Gallon:10.59 lb
Flash Point:N/A
Vehicle Type: Acrylic
Shelf Life:36 months,unopened
Mildew Resistant
This coating contains agents which inhibit the growth
of mildew on the surface of this coating film.
COMPLIANCE
As of 04/07/2020, Complies with:
OTC Yes
OTC Phase II Yes
SCAQMD Yes
CARB Yes
CARB SCM 2007 Yes
Canada YesLEED® v4 & v4.1 Emissions NoLEED® v4 & v4.1 V.O.C.Yes
EPD-NSF® Certified No
MIR-Manufaturer Inventory No
MPI® Yes
APPLICATION
Temperature: air, surface, and material
Minimum 50°F
Reduction: Do not reduce
Brush and Roller: small areas only
FINE AND MEDIUM TEXTURES:
Spray Unit: Graco RTX 1500
Pressure: 30-35 p.s.i. air to the pump
Tip: 3/16-1/4 inch
Reduction: None
EXTRA COARSE TEXTURE:
Spray Unit:Graco 10:1 President Texture Pump
Spray: Unit must be specifically designed for aggregate coatings.
RECOMMENDED SYSTEMS
Concrete, Tilt-Up, Precast, CMU, Stucco, Masonry, Cement Composition:
ConFlex UltraCrete can be used without a primer on surfaces with a pH between 6 and 9. On high pH surfaces, 9 or greater, prime with:
1 coat Loxon Concrete & Masonry Primer
Or
1 coat Loxon Acrylic Block Surfacer
1-2 coats of ConFlex UltraCrete
Steel:
1 coat All Surface Enamel Primer
1-2 coats of ConFlex UltraCrete
Wood, (Exterior) Composition Board:
1 coat Exterior Oil-Based Wood Primer
1-2 coats of ConFlex UltraCrete
Drywall (Interior):
1 coat ProMar 200 Zero VOC Latex Primer
1-2 coats of ConFlex UltraCrete
Drywall (exterior):
1 coat Exterior Latex Wood Primer
1-2 coats of ConFlex UltraCrete
04/2020 www.sherwin-williams.com continued on back
ConFlex® UltraCrete™
Acrylic Texture Coating
SURFACE PREPARATION
WARNING! Removal of old paint by sanding, scraping or other means may generate dust or fumes that contain lead. Exposure to lead dust or fumes may cause brain damage or other adverse health effects, especially in children or pregnant women. Controlling exposure to lead or other hazardous substances requires the use of proper protective equipment, such as a properly fitted respirator (NIOSH approved) and proper containment and cleanup. For more information, call the National Lead Information Center at 1-800-424-LEAD (in US) or contact your local health authority.
Remove all surface contamination by washing with an appropriate cleaner, rinse thoroughly and allow to dry. Scrape and sand peeled or checked paint to a sound surface. Sand glossy surfaces dull. Seal stains from water, smoke, ink, pencil, grease, etc. with the appropriate primer-sealer. Recognize that any surface preparation short of total removal of the old coating may compromise the service length of the system.
Caulking:
Gaps between windows, doors, trim, and other through-wall openings can be filled with the appropriate caulk after priming the surface.
Cement Composition Siding-Panels:
Remove all dirt, dust, grease, oil, loose particles, laitance, foreign material, and peeling or defective coatings. Allow the surface to dry thoroughly. If the surface is new, test it for pH, if the pH is higher than 9, prime with Loxon Concrete and Masonry Primer.
Masonry, Concrete, CMU, Stucco:
Remove all dirt, dust, mildew, loose particles, laitance, foreign material, peeling and defective coatings, chalk, form release agents, moisture curing membranes, etc. All new surfaces must be cured according to the supplier’s recommendations—usually about 30 days. If painting cannot wait 30 days, allow the surface to cure 7 days at 75°F and prime the surface with Loxon Concrete & Masonry Primer or Loxon Acrylic Block Surfacer to fill Block, and CMU.
On tilt-up and poured-in-place concrete, commercial detergents and sandblasting may be necessary to remove sealers, release compounds, and to provide an anchor pattern. Allow the surface to dry thoroughly. Concrete and mortar must be cured at least 30 days and a pH of less than 9 to apply this product directly. Fill bugholes, air pockets, cracks, and other voids with an elastomeric patch or sealant. Rough surfaces can be filled to provide a smooth surface.
Wood:
Sand any exposed wood to a fresh surface. Patch all holes and imperfections with a wood filler or putty and sand smooth. Bare wood and all patched areas must be primed.
SURFACE PREPARATION
Mildew:
Prior to attempting to remove mildew, it is always recommended to test any cleaner on a small, inconspicuous area prior to use. Bleach and bleaching type cleaners may damage or discolor existing paint films. Bleach alternative cleaning solutions may be advised.
Mildew may be removed before painting by washing with a solution of 1 part liquid bleach and 3 parts water. Apply the solution and scrub the mildewed area. Allow the solution to remain on the surface for 10 minutes. Rinse thoroughly with water and allow the surface to dry before painting. Wear protective eyewear, waterproof gloves, and protective clothing. Quickly wash off any of the mixture that comes in contact with your skin. Do not add detergents or ammonia to the bleach-water solution.
PHYSICAL PROPERTIES
CF17W0801
(may vary by product)
Wind-Driven Rain1 :
Method:ASTM D6904-03
Result:Pass
Water Vapor Permeance2:
Method:Based on ASTM D1653 14 day cure @ 77°F & 50% RH
Result:23.0 perms
Flexibility:
Method:ASTM D522 - Method B, 180° bend, 1/4” mandrel
Result:Pass
Alkali Resistance:
Method:Based on ASTM D1308
Result:Pass
Impact Resistance:
Method:ASTM D2794
Result:Pass
Salt Spray3:
Method:ASTM B117, 300 hours Blasted Steel panels
Result:no blisters, 0 rust Creep, rating of 10
Adhesion:
Method:ASTM D3359 Method B, smooth concrete
Result:Pass
11 coat Loxon Masonry Primer at 3.2 mils D.F.T.2 coats ConFlex UltraCrete at 13.5-18 mils D.F.T.
2 1coat ConFlex UltraCrete at 9.4 mils D.F.T.
3 1 coat Pro Industrial Pro-Cryl Primer
1 coat ConFlex UltraCrete
CAUTIONS
Protect from freezing.
Not for use on horizontal surfaces (floors, roofs, decks, etc.) where water will collect.
Not for use on overhead horizontal surfaces (under sides of balconies, soffits, etc.)
Not for use below grade or underwater. Will not withstand hydrostatic pressure.
On areas subject to wear, some of the texture may be abraded off.
Before using, carefully read CAUTIONS on label.
CRYSTALLINE SILICA: Use only with adequate
ventilation. To avoid overexposure, open windows and
doors or use other means to ensure fresh air entry during
application and drying. If you experience eye watering,
headaches, or dizziness, increase fresh air, or wear
respiratory protection (NIOSH approved) or leave the
area. Adequate ventilation required when sanding or
abrading the dried film. If adequate ventilation cannot be
provided wear an approved particulate respirator (NIOSH
approved). Follow respirator manufacturer’s directions
for respirator use. Avoid contact with eyes and skin.
Wash hands after using. Keep container closed when
not in use. Do not transfer contents to other containers
for storage. FIRST AID: In case of eye contact, flush
thoroughly with large amounts of water. Get medical
attention if irritation persists. If swallowed, call Poison
Control Center, hospital emergency room, or physician
immediately. DELAYED EFFECTS FROM LONG TERM
OVEREXPOSURE. Abrading or sanding of the dry film
may release crystalline silica which has been shown
to cause lung damage and cancer under long term
exposure. WARNING: This product contains chemicals
known to the State of California to cause cancer and
birth defects or other reproductive harm. DO NOT
TAKE INTERNALLY. KEEP OUT OF THE REACH OF
CHILDREN.
HOTW 04/06/2020 CF17W0801 30 47
HOTW 04/06/2020 CF17W0811 33 46
HOTW 04/06/2020 CF17W0821 27 44
FRC,SP
CLEANUP INFORMATION
Clean spills, spatters, hands and tools immediately after use with soap and warm water. After cleaning, flush spray equipment with compliant cleanup solvent to prevent rusting of the equipment. Follow manufacturer’s safety recommendations when using solvents.
The information and recommendations set forth in this Product Data Sheet are based upon tests conducted by or on behalf of The Sherwin-Williams
Company. Such information and recommendations set forth herein are subject to change and pertain to the product offered at the time of publication.
Consult your Sherwin-Williams representative or visit www.paintdocs.com to obtain the most current version of the PDS and/or an SDS.