Loading...
ACHD Transmittal(A-2020-0199)Applicant name: ERIC SHAW, POWDER RIVER DEVELOPMENT SERVICES/ON BEHALF OF VERIZON WIRELESS Phone: Applicant address:408 S. EAGLE RD. SUITE 200, EAGLE, ID 83616 Email:eric.shaw@powderriverdev.com Owner name:PAUL DAIGLE, ADA COUNTY HIGHWAY DISTRICT Phone:Fax: Owner address:3775 N. ADAMS ST., GARDEN CITY, ID 83714 Email:crasavage@achdidaho.org Administrative Applicant Information Type of Review Requested File number:A-2020-0199 Assigned Planner:Cameron Scott Related Files: Subject Property Information Location/street address:3175 S MERIDIAN RD, STE 100 Assessor's parcel number(s):R8186120241 Township, range, section:3N1W24 Agent name (e.g. architect, engineer, developer, representative):ERIC SHAW Firm name: POWDER RIVER DEVELOPMENT SERVICES/ON BEHALF OF VERIZON WIRELESS Phone:Fax: Address:408 S. EAGLE RD. SUITE 200 Email:eric.shaw@powderriverdev.com Contact name:Phone:Fax: Contact address:Email: Project Description Planning Division ADMINISTRATIVE APPLICATION 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 1 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 2 Project/Application Name:Verizon NWC Meridian and Victory - CZC Description of Work: Collocation of cell tower with existing ACHD traffic signal located at NW corner of S. Meridian Rd./W. Victory Rd. This address represents nearest parcel to location. City of Meridian 33 E. Broadway Ave., Meridian, Idaho 83642 Installation of: 1 Pole-top assembly with canister antenna and radio shroud along with associated power/fiber conduits, 3 panel antennas, 2 junction boxes, 1 fronthaul, 1 fiber demarcation box and 1 Power Disconnect Stand w/ Power Disconnect Switch- onto existing traffic light pole within the right of way. 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 3 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 4 APPLICATION TYPES Is this application exempt from fees?:No Certificate of Zoning Compliance - CZC:CHECKED Does project have prior approval?:Yes Does your project contain new construction and/or modifications to an existing building or the site?: No ADDRESS VERIFICATION Address Verification Permit Number:LDAV-2020-0651 TYPE OF USE PROPOSED Commercial:CHECKED Other Type of Use Proposed:Colocation of Wireless antennas on existing structure in the Right of Way. PROPERTY INFORMATION General Location:Northwest corner of Meridian Rd & W Victory Rd (near 3175 S Meridian Rd) Current Land Use:Existing ACHD light pole in ROW Total Acreage:n/a Prior Approvals (File Numbers):A-2018-0356 ZONING DISTRICT(S) L-O:CHECKED PROJECT INFORMATION Site Plan Date (MM/DD/YYYY):10/03/2019 Landscape Plan Date (MM/DD/YYYY):10/03/2019 Elevations Date (MM/DD/YYYY):10/03/2019 In Reclaimed Water Buffer:No SEND NOTIFICATION EMAIL NOTIFICATION SENT (System Use Only):CHECKED TIME EXTENSION INFORMATION Number of months extension:24 APPLICATION DISCLAIMER I have read and accept the above terms:CHECKED Your signature:Eric Shaw Application Information 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 5 33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642 Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org 6 TITLE SHEET DRIVING DIRECTIONS VICINITY MAP SITE PHOTO N APPLICABLE CODES SCOPE OF WORK SITE T-1 DRAWING INDEX 34' TALL TRAFFIC SIGNAL POLE SMALL CELL NEW BUILD VZW SITE NAME: BOI LEGACY SC LOCATION: 3175 S MERIDIAN ROAD MERIDIAN, ID 83642 VERIZON SITE NAME: BOI LEGACY SC 3175 S MERIDIAN ROAD MERIDIAN, ID 83642 43.575667°, -116.394143° SITE INFORMATION CONTACT INFORMATION 10/03/19 VERIZON SITE NAME: BOI LEGACY SC 3175 S MERIDIAN ROAD MERIDIAN, ID 83642 43.575667°, -116.394143° GENERAL NOTES GN-1 10/03/19 VERIZON SITE NAME: BOI LEGACY SC 3175 S MERIDIAN ROAD MERIDIAN, ID 83642 43.575667°, -116.394143° GN-2 GENERAL NOTES ” 10/03/19 VERIZON SITE NAME: BOI LEGACY SC 3175 S MERIDIAN ROAD MERIDIAN, ID 83642 43.575667°, -116.394143° WORK AREA SITE PLAN SITE PLAN C-1 N 2SCALE: 3/32" = 1'-0" (11x17)OVERALL SITE PLAN 1SCALE: 1" = 40' (11x17) N 10/03/19 MERIDIANRD 31003200 S VERIZON SITE NAME: BOI LEGACY SC 3175 S MERIDIAN ROAD MERIDIAN, ID 83642 43.575667°, -116.394143° EXISTING ELEVATION 1 C-2EXISTING EAST ELEVATION SCALE: 3/16" = 1'-0" (11x17) 10/03/19 MERIDIANRD 31003200 S VERIZON SITE NAME: BOI LEGACY SC 3175 S MERIDIAN ROAD MERIDIAN, ID 83642 43.575667°, -116.394143° PROPOSED ELEVATION 1 C-3PROPOSED EAST ELEVATION SCALE: 3/16" = 1'-0" (11x17) A A 10/03/19 VERIZON SITE NAME: BOI LEGACY SC 3175 S MERIDIAN ROAD MERIDIAN, ID 83642 43.575667°, -116.394143° EQUIPMENT DETAILS C-42SCALE: N.T.S.POLE-TOP ATTACHMENT DETAIL (REFERENCE ONLY) 1SCALE: N.T.S. ANTENNA INFORMATION ANTENNA INFORMATION SCALE: N.T.S.3 10/03/19 VERIZON SITE NAME: BOI LEGACY SC 3175 S MERIDIAN ROAD MERIDIAN, ID 83642 43.575667°, -116.394143° EQUIPMENT DETAILS C-52SCALE: N.T.S.NOT USED 4 1SCALE: N.T.S. ANTENNA BANDING ASSEMBLY 3 ANTENNA EQUIPMENT MOUNTDISCONNECT STAND DETAIL 10/03/19 VERIZON SITE NAME: BOI LEGACY SC 3175 S MERIDIAN ROAD MERIDIAN, ID 83642 43.575667°, -116.394143° EQUIPMENT DETAILS C-61SCALE: N.T.S.RADIO CONCEALMENT ANTENNA MOUNT2SCALE: N.T.S.RADIO CONCEALMENT ANTENNA MOUNT 10/03/19 VERIZON SITE NAME: BOI LEGACY SC 3175 S MERIDIAN ROAD MERIDIAN, ID 83642 43.575667°, -116.394143° EQUIPMENT DETAILS C-72SCALE: N.T.S.FIBER DEMARCATION BOX 4SCALE: N.T.S. 1SCALE: N.T.S.3SCALE: N.T.S.RF WARNING SIGN 6 5SCALE: N.T.S.RRH INFORMATIONDWDM ENCLOSURE JUNCTION BOX INFORMATION · · LOAD CENTER CIRCUIT BREAKER DETAIL 10/03/19 At the Service disconnect:SERVICE DISCONNECTVERIZON EQUIPMENT ONLYINDEPENDENT OF TRAFFIC POLE POWER,LIGHTING, CAMERAS, SIGNALS At the ACHD service/equipment pedestal door:ADDITIONAL SERVICE DISCONNECT LOCATEDAT__________(EXAMPLES: SW CORNER, NE CORNER, SOUTH INTERSECTION ETC.)VERIZON EQUIPMENT ONLYINDEPENDENT OF TRAFFIC POLE POWER,LIGHTING, CAMERAS, SIGNALS VERIZON SITE NAME: BOI LEGACY SC 3175 S MERIDIAN ROAD MERIDIAN, ID 83642 43.575667°, -116.394143° EQUIPMENT DETAILS C-82SCALE: N.T.S. JUNCTION BOX DETAIL 4 1SCALE: N.T.S.3NOT USED 6 5 NOT USED SURGE PROTECTION DETAIL DISCONNECT STICKER DETAIL NOT USED 10/03/19 VERIZON SITE NAME: BOI LEGACY SC 3175 S MERIDIAN ROAD MERIDIAN, ID 83642 43.575667°, -116.394143° EQUIPMENT DETAILS C-92CONDUIT MOUNTING DETAIL NOT USED3SCALE: N.T.S. 1SCALE: N.T.S.CONDUIT TRENCH DETAIL 10/03/19 VERIZON SITE NAME: BOI LEGACY SC 3175 S MERIDIAN ROAD MERIDIAN, ID 83642 43.575667°, -116.394143° EQUIPMENT DETAILS C-101SCALE: N.T.S.UNDERGROUND VAULT 10/03/19 VERIZON SITE NAME: BOI LEGACY SC 3175 S MERIDIAN ROAD MERIDIAN, ID 83642 43.575667°, -116.394143° EQUIPMENT DETAILS C-111SCALE: N.T.S.BREAK AWAY DISCONNECT 10/03/19 VERIZON SITE NAME: BOI LEGACY SC 3175 S MERIDIAN ROAD MERIDIAN, ID 83642 43.575667°, -116.394143° ELECTRICAL DETAILS E-11SCALE: N.T.S.ELECTRICAL DIAGRAMS 10/03/19 VERIZON SITE NAME: BOI LEGACY SC 3175 S MERIDIAN ROAD MERIDIAN, ID 83642 43.575667°, -116.394143° GROUNDING PLAN G-11SCALE: N.T.S.GROUNDING PLAN NN 10/03/19 VERIZON SITE NAME:BOI LEGACY SC3175 S MERIDIAN ROADMERIDIAN, ID 8364243.575667°, -116.394143°GROUNDINGDETAILSG-221SCALE: N.T.S.SCALE: N.T.S.3465NOT USEDCADWELD CONNECTION TYPESGROUND BAR DETAILNOT USEDNOT USEDNOT USED10/03/19 City of Meridian Planning and Development Services Certificate of Zoning Compliance Subject: LETTER OF EXPLANATION (Project Narrative) Site Name: BOI Legacy SC Location info: Northwest corner of Meridian Rd & W Victory Rd (near 3175 S Meridian Rd) Powder River Development Services is representing Verizon Wireless for the Small Cell network expansion project on an existing ACHD traffic Pole in Meridian in the Public Right of Way (This project was previously approved but was delayed and prior approval expired). Due to the demand for data and cell coverage in the area, Verizon Wireless is proposing: Installation of: 1 Pole-top assembly with canister antenna and radio shroud along with associated power/fiber conduits, 3 panel antennas, 2 junction boxes, 1 fronthaul, 1 fiber demarcation box and 1 Power Disconnect Stand w/ Power Disconnect Switch- onto existing traffic light pole within the right of way. Verizon Wireless and Ada County Highway District have an agreement in place to locate their equipment on the traffic signals and light poles owned by ACHD in the Right of Way. All associated permits will be completed with the Ada County Highway District prior to construction commencing. It is the goal of Verizon Wireless to provide the area with reliable wireless services. Approving this application will allow Verizon to continue providing the best service to its customers in the surrounding area. Documents/Drawing sheets uploaded: • Narrative (Letter of Explanation with site photos) • CD Pages- Site Plan- Elevations- Map- Specs • Affidavit of Legal Interest_ACHD • CZC, HOSC (A-2018-0356) Prior expired zoning approval for reference Please notify me if additional materials/documents are required for review & approval of project, or if any of the documentation needs to be titled and formatted differently for upload with your newer online submittal process. Eric Shaw Site Acquisition Agent Powder River Development Services, LLC 408 S. Eagle Rd., Suite 200, Eagle, ID 83616 208.963.4014 Powder River Development Services, LLC 408 S. Eagle Rd., Suite 200 Eagle, ID 83616 (208) 938-8844 office (208) 938-8855 fax www.powderriverdev.com Photos of Site: Location info: Northwest corner of Meridian Rd & W Victory Rd EXISTING light pole at site location (view facing Northwest) EXISTING light pole at site location (view facing East) Page 1 DATE: 10/30/2020 TO: Eric Shaw, Powder River Development Services, LLC FROM: Cam Scott, Assistant Planner 208-884-5533 SUBJECT: A-2020-0199 Verizon NWC Meridian and Victory LOCATION: NWC S Meridian Rd. and W Victory Rd. I. PROJECT DESCRIPTION The applicant, Eric Shaw, requests Certificate of Zoning Compliance (CZC) approval to install wireless communication equipment on an existing traffic pole in the right-of-way in the L-O zoning district. The scope of work includes: • Installation of one (1) pole-top assembly with canister antenna and radio shroud along with associated power/fiber conduits, three (3) panel antennas, two (2) junction boxes, one (1) fronthaul, one (1) fiber demarcation box, and one (1) power disconnect stand with power disconnect switch. The site is located on the northwest corner of S Meridian Rd. and W Victory Rd. All associated permits will be completed with ACHD and Idaho Power prior to construction commencing. II. DECISION The applicant's request for Certificate of Zoning Compliance is approved with the conditions listed in this report. Note: This is not a building permit. Please contact Building Services at (208) 887-2211 to verify if you need a building permit and/or inspection. If you do need a building permit, you must complete that process before you commence the use or construction. Please contact Building Services for additional details about building permits and inspections. CERTIFICATE OF ZONING COMPLIANCE REPORT COMMUNITY DEVELOPMENT DEPARTMENT Page 2 Site Specific Conditions of Approval 1. The applicant shall complete all improvements related to public life, safety, and health as set forth in UDC 11-5C-3B. A surety agreement may be accepted for other improvements in accord with UDC 11-5C-3C. 2. The site plan prepared by Powder River Development Services, LLC on May 20, 2019, labeled C-1, is approved by the City of Meridian Planning Division as shown in Exhibit B. 3. The elevations prepared by Powder River Development Services, LLC on May 20, 2019, labeled C-2 and C-3, are approved by the City of Meridian Planning Division as shown in Exhibit B. 4. The approved site plan and/or elevations may not be altered without prior written approval of the City of Meridian Planning Division. 5. The applicant shall pay any applicable impact fees prior to the issuance of a building permit. 6. If any changes must be made to the site plan to accommodate ACHD requirements, the applicant shall submit a new site plan to the City of Meridian Planning Division for approval prior to issuance of the building permit. General Conditions of Approval 1. The project is subject to all current City of Meridian ordinances and previous conditions of approval associated with this site. 2. The issuance of this CZC does not release the applicant from any previous requirements of the other permits issued for the site. 3. The applicant and/or assigns shall have the continuing obligation to meet the specific use standards for the proposed use as set forth in UDC 11-4-3-43: Wireless Communication Facility. III. CITY COUNCIL REVIEW The applicant or a party of record may request City Council review of a decision of the Director. All requests for review shall be filed in writing with the Planning Division on or before November 16, 2020, within fifteen (15) days after the written decision is issued, and contain the information listed in UDC 11-5A-6B. If City Council review of the decision is not requested, the action of the Director represents a final decision on a land use application. You have the right to request a regulatory taking analysis under Idaho Code 67-8003. IV. EXPIRATION The Certificate of Zoning Compliance shall expire if the construction, alteration or the use has not commenced within one year of the date of issuance of the Certificate of Zoning Compliance. In accord with the above provisions, the subject Certificate of Zoning Compliance is valid until October 30, 2021. Page 3 V. EXHIBITS A. Site Plan (date: 5/24/2019) Page 4 B. Elevations (date: 5/24/2019)