ACHD Transmittal(A-2020-0199)Applicant name:
ERIC SHAW, POWDER RIVER DEVELOPMENT SERVICES/ON BEHALF OF
VERIZON WIRELESS Phone:
Applicant address:408 S. EAGLE RD. SUITE 200, EAGLE, ID 83616 Email:eric.shaw@powderriverdev.com
Owner name:PAUL DAIGLE, ADA COUNTY HIGHWAY DISTRICT Phone:Fax:
Owner address:3775 N. ADAMS ST., GARDEN CITY, ID 83714 Email:crasavage@achdidaho.org
Administrative
Applicant Information
Type of Review Requested
File number:A-2020-0199
Assigned Planner:Cameron Scott
Related Files:
Subject Property Information
Location/street address:3175 S MERIDIAN RD, STE 100
Assessor's parcel number(s):R8186120241
Township, range, section:3N1W24
Agent name (e.g. architect, engineer, developer, representative):ERIC SHAW
Firm name:
POWDER RIVER DEVELOPMENT SERVICES/ON BEHALF OF
VERIZON WIRELESS Phone:Fax:
Address:408 S. EAGLE RD. SUITE 200 Email:eric.shaw@powderriverdev.com
Contact name:Phone:Fax:
Contact address:Email:
Project Description
Planning Division
ADMINISTRATIVE APPLICATION
33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642
Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org
1
33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642
Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org
2
Project/Application Name:Verizon NWC Meridian and Victory - CZC
Description of Work:
Collocation of cell tower with existing ACHD traffic signal located at NW corner of S. Meridian Rd./W. Victory
Rd. This
address represents nearest parcel to location. City of Meridian
33 E. Broadway Ave., Meridian, Idaho 83642
Installation of: 1 Pole-top assembly with canister antenna and radio shroud along with associated
power/fiber conduits, 3 panel antennas, 2 junction boxes, 1 fronthaul, 1 fiber demarcation box and 1 Power
Disconnect Stand w/ Power Disconnect Switch- onto existing traffic light pole within the right of way.
33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642
Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org
3
33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642
Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org
4
APPLICATION TYPES
Is this application exempt from fees?:No
Certificate of Zoning Compliance - CZC:CHECKED
Does project have prior approval?:Yes
Does your project contain new construction and/or modifications to an existing
building or the site?:
No
ADDRESS VERIFICATION
Address Verification Permit Number:LDAV-2020-0651
TYPE OF USE PROPOSED
Commercial:CHECKED
Other Type of Use Proposed:Colocation of Wireless antennas on existing
structure in the Right of Way.
PROPERTY INFORMATION
General Location:Northwest corner of Meridian Rd & W Victory Rd
(near 3175 S Meridian Rd)
Current Land Use:Existing ACHD light pole in ROW
Total Acreage:n/a
Prior Approvals (File Numbers):A-2018-0356
ZONING DISTRICT(S)
L-O:CHECKED
PROJECT INFORMATION
Site Plan Date (MM/DD/YYYY):10/03/2019
Landscape Plan Date (MM/DD/YYYY):10/03/2019
Elevations Date (MM/DD/YYYY):10/03/2019
In Reclaimed Water Buffer:No
SEND NOTIFICATION
EMAIL NOTIFICATION SENT (System Use Only):CHECKED
TIME EXTENSION INFORMATION
Number of months extension:24
APPLICATION DISCLAIMER
I have read and accept the above terms:CHECKED
Your signature:Eric Shaw
Application Information
33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642
Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org
5
33 E Broadway Avenue, Suite 102ƔMeridian, Idaho 83642
Phone: (208)884-5533ƔFacsimile: (208) 888-6854ƔWebsite: www.meridaincity.org
6
TITLE SHEET
DRIVING DIRECTIONS
VICINITY MAP SITE PHOTO
N
APPLICABLE CODES
SCOPE OF WORK
SITE
T-1
DRAWING INDEX
34' TALL TRAFFIC SIGNAL POLE
SMALL CELL NEW BUILD
VZW SITE NAME:
BOI LEGACY SC
LOCATION:
3175 S MERIDIAN ROAD
MERIDIAN, ID 83642
VERIZON SITE NAME:
BOI LEGACY SC
3175 S MERIDIAN ROAD
MERIDIAN, ID 83642
43.575667°, -116.394143°
SITE INFORMATION
CONTACT INFORMATION
10/03/19
VERIZON SITE NAME:
BOI LEGACY SC
3175 S MERIDIAN ROAD
MERIDIAN, ID 83642
43.575667°, -116.394143°
GENERAL
NOTES
GN-1
10/03/19
VERIZON SITE NAME:
BOI LEGACY SC
3175 S MERIDIAN ROAD
MERIDIAN, ID 83642
43.575667°, -116.394143°
GN-2
GENERAL
NOTES
”
10/03/19
VERIZON SITE NAME:
BOI LEGACY SC
3175 S MERIDIAN ROAD
MERIDIAN, ID 83642
43.575667°, -116.394143°
WORK AREA SITE PLAN
SITE PLAN
C-1
N
2SCALE: 3/32" = 1'-0" (11x17)OVERALL SITE PLAN 1SCALE: 1" = 40' (11x17)
N
10/03/19
MERIDIANRD
31003200
S
VERIZON SITE NAME:
BOI LEGACY SC
3175 S MERIDIAN ROAD
MERIDIAN, ID 83642
43.575667°, -116.394143°
EXISTING
ELEVATION
1 C-2EXISTING EAST ELEVATION SCALE: 3/16" = 1'-0" (11x17)
10/03/19
MERIDIANRD
31003200
S
VERIZON SITE NAME:
BOI LEGACY SC
3175 S MERIDIAN ROAD
MERIDIAN, ID 83642
43.575667°, -116.394143°
PROPOSED
ELEVATION
1 C-3PROPOSED EAST ELEVATION SCALE: 3/16" = 1'-0" (11x17)
A A
10/03/19
VERIZON SITE NAME:
BOI LEGACY SC
3175 S MERIDIAN ROAD
MERIDIAN, ID 83642
43.575667°, -116.394143°
EQUIPMENT
DETAILS
C-42SCALE: N.T.S.POLE-TOP ATTACHMENT DETAIL (REFERENCE ONLY)
1SCALE: N.T.S.
ANTENNA INFORMATION
ANTENNA INFORMATION
SCALE: N.T.S.3
10/03/19
VERIZON SITE NAME:
BOI LEGACY SC
3175 S MERIDIAN ROAD
MERIDIAN, ID 83642
43.575667°, -116.394143°
EQUIPMENT
DETAILS
C-52SCALE: N.T.S.NOT USED 4
1SCALE: N.T.S.
ANTENNA BANDING ASSEMBLY
3 ANTENNA EQUIPMENT MOUNTDISCONNECT STAND DETAIL
10/03/19
VERIZON SITE NAME:
BOI LEGACY SC
3175 S MERIDIAN ROAD
MERIDIAN, ID 83642
43.575667°, -116.394143°
EQUIPMENT
DETAILS
C-61SCALE: N.T.S.RADIO CONCEALMENT ANTENNA MOUNT2SCALE: N.T.S.RADIO CONCEALMENT ANTENNA MOUNT
10/03/19
VERIZON SITE NAME:
BOI LEGACY SC
3175 S MERIDIAN ROAD
MERIDIAN, ID 83642
43.575667°, -116.394143°
EQUIPMENT
DETAILS
C-72SCALE: N.T.S.FIBER DEMARCATION BOX 4SCALE: N.T.S.
1SCALE: N.T.S.3SCALE: N.T.S.RF WARNING SIGN
6
5SCALE: N.T.S.RRH INFORMATIONDWDM ENCLOSURE
JUNCTION BOX INFORMATION
·
·
LOAD CENTER CIRCUIT BREAKER DETAIL
10/03/19
At the Service disconnect:SERVICE DISCONNECTVERIZON EQUIPMENT ONLYINDEPENDENT OF TRAFFIC POLE POWER,LIGHTING, CAMERAS, SIGNALS
At the ACHD service/equipment pedestal door:ADDITIONAL SERVICE DISCONNECT LOCATEDAT__________(EXAMPLES: SW CORNER, NE CORNER, SOUTH
INTERSECTION ETC.)VERIZON EQUIPMENT ONLYINDEPENDENT OF TRAFFIC POLE POWER,LIGHTING, CAMERAS, SIGNALS
VERIZON SITE NAME:
BOI LEGACY SC
3175 S MERIDIAN ROAD
MERIDIAN, ID 83642
43.575667°, -116.394143°
EQUIPMENT
DETAILS
C-82SCALE: N.T.S.
JUNCTION BOX DETAIL
4
1SCALE: N.T.S.3NOT USED
6
5
NOT USED SURGE PROTECTION DETAIL
DISCONNECT STICKER DETAIL
NOT USED
10/03/19
VERIZON SITE NAME:
BOI LEGACY SC
3175 S MERIDIAN ROAD
MERIDIAN, ID 83642
43.575667°, -116.394143°
EQUIPMENT
DETAILS
C-92CONDUIT MOUNTING DETAIL NOT USED3SCALE: N.T.S.
1SCALE: N.T.S.CONDUIT TRENCH DETAIL
10/03/19
VERIZON SITE NAME:
BOI LEGACY SC
3175 S MERIDIAN ROAD
MERIDIAN, ID 83642
43.575667°, -116.394143°
EQUIPMENT
DETAILS
C-101SCALE: N.T.S.UNDERGROUND VAULT
10/03/19
VERIZON SITE NAME:
BOI LEGACY SC
3175 S MERIDIAN ROAD
MERIDIAN, ID 83642
43.575667°, -116.394143°
EQUIPMENT
DETAILS
C-111SCALE: N.T.S.BREAK AWAY DISCONNECT
10/03/19
VERIZON SITE NAME:
BOI LEGACY SC
3175 S MERIDIAN ROAD
MERIDIAN, ID 83642
43.575667°, -116.394143°
ELECTRICAL
DETAILS
E-11SCALE: N.T.S.ELECTRICAL DIAGRAMS
10/03/19
VERIZON SITE NAME:
BOI LEGACY SC
3175 S MERIDIAN ROAD
MERIDIAN, ID 83642
43.575667°, -116.394143°
GROUNDING
PLAN
G-11SCALE: N.T.S.GROUNDING PLAN
NN
10/03/19
VERIZON SITE NAME:BOI LEGACY SC3175 S MERIDIAN ROADMERIDIAN, ID 8364243.575667°, -116.394143°GROUNDINGDETAILSG-221SCALE: N.T.S.SCALE: N.T.S.3465NOT USEDCADWELD CONNECTION TYPESGROUND BAR DETAILNOT USEDNOT USEDNOT USED10/03/19
City of Meridian
Planning and Development Services
Certificate of Zoning Compliance
Subject: LETTER OF EXPLANATION (Project Narrative)
Site Name: BOI Legacy SC
Location info: Northwest corner of Meridian Rd & W Victory Rd
(near 3175 S Meridian Rd)
Powder River Development Services is representing Verizon Wireless for the Small Cell
network expansion project on an existing ACHD traffic Pole in Meridian in the Public Right of
Way (This project was previously approved but was delayed and prior approval expired).
Due to the demand for data and cell coverage in the area, Verizon Wireless is proposing:
Installation of: 1 Pole-top assembly with canister antenna and radio shroud along with
associated power/fiber conduits, 3 panel antennas, 2 junction boxes, 1 fronthaul, 1 fiber
demarcation box and 1 Power Disconnect Stand w/ Power Disconnect Switch- onto
existing traffic light pole within the right of way.
Verizon Wireless and Ada County Highway District have an agreement in place to locate their
equipment on the traffic signals and light poles owned by ACHD in the Right of Way. All
associated permits will be completed with the Ada County Highway District prior to construction
commencing. It is the goal of Verizon Wireless to provide the area with reliable wireless
services. Approving this application will allow Verizon to continue providing the best service to
its customers in the surrounding area.
Documents/Drawing sheets uploaded:
• Narrative (Letter of Explanation with site photos)
• CD Pages- Site Plan- Elevations- Map- Specs
• Affidavit of Legal Interest_ACHD
• CZC, HOSC (A-2018-0356) Prior expired zoning approval for reference
Please notify me if additional materials/documents are required for review & approval of project,
or if any of the documentation needs to be titled and formatted differently for upload with your
newer online submittal process.
Eric Shaw
Site Acquisition Agent
Powder River Development Services, LLC
408 S. Eagle Rd., Suite 200, Eagle, ID 83616
208.963.4014
Powder River Development Services, LLC
408 S. Eagle Rd., Suite 200
Eagle, ID 83616
(208) 938-8844 office
(208) 938-8855 fax
www.powderriverdev.com
Photos of Site:
Location info: Northwest corner of Meridian Rd & W Victory Rd
EXISTING light pole at site location (view facing Northwest)
EXISTING light pole at site location (view facing East)
Page 1
DATE: 10/30/2020
TO: Eric Shaw, Powder River Development
Services, LLC
FROM: Cam Scott, Assistant Planner
208-884-5533
SUBJECT: A-2020-0199
Verizon NWC Meridian and Victory
LOCATION: NWC S Meridian Rd. and W Victory Rd.
I. PROJECT DESCRIPTION
The applicant, Eric Shaw, requests Certificate of Zoning Compliance (CZC) approval to
install wireless communication equipment on an existing traffic pole in the right-of-way in
the L-O zoning district.
The scope of work includes:
• Installation of one (1) pole-top assembly with canister antenna and radio shroud along with
associated power/fiber conduits, three (3) panel antennas, two (2) junction boxes, one (1)
fronthaul, one (1) fiber demarcation box, and one (1) power disconnect stand with power
disconnect switch.
The site is located on the northwest corner of S Meridian Rd. and W Victory Rd.
All associated permits will be completed with ACHD and Idaho Power prior to construction
commencing.
II. DECISION
The applicant's request for Certificate of Zoning Compliance is approved with the conditions listed in
this report.
Note: This is not a building permit. Please contact Building Services at (208) 887-2211 to verify if
you need a building permit and/or inspection. If you do need a building permit, you must complete
that process before you commence the use or construction. Please contact Building Services for
additional details about building permits and inspections.
CERTIFICATE OF ZONING
COMPLIANCE REPORT
COMMUNITY DEVELOPMENT DEPARTMENT
Page 2
Site Specific Conditions of Approval
1. The applicant shall complete all improvements related to public life, safety, and health as set forth
in UDC 11-5C-3B. A surety agreement may be accepted for other improvements in accord with
UDC 11-5C-3C.
2. The site plan prepared by Powder River Development Services, LLC on May 20, 2019, labeled
C-1, is approved by the City of Meridian Planning Division as shown in Exhibit B.
3. The elevations prepared by Powder River Development Services, LLC on May 20, 2019, labeled
C-2 and C-3, are approved by the City of Meridian Planning Division as shown in Exhibit B.
4. The approved site plan and/or elevations may not be altered without prior written approval of the
City of Meridian Planning Division.
5. The applicant shall pay any applicable impact fees prior to the issuance of a building permit.
6. If any changes must be made to the site plan to accommodate ACHD requirements, the applicant
shall submit a new site plan to the City of Meridian Planning Division for approval prior to
issuance of the building permit.
General Conditions of Approval
1. The project is subject to all current City of Meridian ordinances and previous conditions of
approval associated with this site.
2. The issuance of this CZC does not release the applicant from any previous requirements of the
other permits issued for the site.
3. The applicant and/or assigns shall have the continuing obligation to meet the specific use
standards for the proposed use as set forth in UDC 11-4-3-43: Wireless Communication Facility.
III. CITY COUNCIL REVIEW
The applicant or a party of record may request City Council review of a decision of the Director. All
requests for review shall be filed in writing with the Planning Division on or before November 16,
2020, within fifteen (15) days after the written decision is issued, and contain the information listed in
UDC 11-5A-6B.
If City Council review of the decision is not requested, the action of the Director represents a final
decision on a land use application. You have the right to request a regulatory taking analysis under
Idaho Code 67-8003.
IV. EXPIRATION
The Certificate of Zoning Compliance shall expire if the construction, alteration or the use has not
commenced within one year of the date of issuance of the Certificate of Zoning Compliance.
In accord with the above provisions, the subject Certificate of Zoning Compliance is valid until
October 30, 2021.
Page 3
V. EXHIBITS
A. Site Plan (date: 5/24/2019)
Page 4
B. Elevations (date: 5/24/2019)