Loading...
PZ - Landscape Plan-L1.0 LANDSCAPE NOTES: LANDSCAPE LEGEND 1. CONTRACTOR SHALL REPORT TO LANDSCAPE ARCHITECT ALL CONDITIONS WHICH IMPAIR AND/OR PREVENT THE PROPER EXECUTION OF THIS WORK, PRIOR TO BEGINNING WORK. ® PLANTS TO BE INSTALLED 2. NO MATERIAL SUBSTITUTIONS SHALL BE MADE WITHOUT THE LANDSCAPE ARCHITECT'S PRIOR WRITTEN APPROVAL. ALTERNATE MATERIALS OF M S 89°47'43"W 396.12' SIMILAR SIZE AND CHARACTER MAY BE CONSIDERED IF SPECIFIED PLANT MATERIALS CAN NOT BE OBTAINED. 3. COORDINATE ALL WORK WITH ALL OTHER SITE RELATED DEVELOPMENT DRAWINGS. ROOT FLARE TO BE AT SOIL LINE. 4. COORDINATE WORK SCHEDULE AND OBSERVATIONS WITH LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION START-UP. - - - - - - - - - - CUT EDGE AS DETAILED H2 H2O H2O 5. ALL PLANT MATERIAL SHALL BE INSTALLED AS PER DETAILS. )[IH2O H2O H2O H2O H2G 2 G S GAS v 6. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR TYPE AND SIZE SHOWN. PLANTS WILL BE REJECTED IF NOT ve PREVAILING WIND DIRECTION IN A SOUND AND HEALTHY CONDITION. GT 5 QUANTITY Catch Basin: 7. IN THE EVENT OF A PLANT COUNT DISCREPANCY, PLANT SYMBOLS SHALL OVERRIDE SCHEDULE QUANTITIES AND CALL OUT SYMBOL NUMBERS. RE PLANT IDENTIFICATION KEY OA71AQ Rim=2592.49' 8. ALL PLANTING BEDS SHALL BE COVERED WITH A MINIMUM OF 3"DEPTH OF LARGE(1"MINUS)BARK MULCH. SUBMIT SAMPLE FOR APPROVAL. •12� �f6�P REMOVE DEAD/DAMAGED BRANCHES AND "•:' : No Ca Inv=2590.95' SOIL LINE PRUNE TO INTERNATIONAL SOCIETY OF 9. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING AT THE DATE OF ACCEPTANCE BY THE OWNER. REPLACE ALL 7 " .Y.:` 'i. MB p PLANT MATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY WITH THE SAME SIZE AND SPECIES AT NO COST TO THE OWNER. ,. I:: •!"•";"�::,'•.. ' �'••�t. � I ARBORICULTURE STANDARDS; IMPROPERLY g " '�' !`•'•:'., �' .. PRUNED TREES(AS DETERMINED BY THE 10. FINISH GRADES SHALL PROVIDE A SMOOTH TRANSITION WITH ADJACENT SURFACES AND ENSURE POSITIVE DRAINAGE IN ACCORDANCE WITH THE I "� a'~'' •�.... 6 SITE GRADING PLAN. BUILDING LOCATION IC ""�'""" '"' ' ^'" SM LANDSCAPE ARCHITECT)SHALL BE REMOVED ° AND REPLACED. DO NOT REMOVE MAIN 11. AMEND EXISTING APPROVED TOPSOIL AT A RATIO OF THREE CUBIC YARDS OF APPROVED COMPOST PER 1000 SQUARE FEET. ROTO-TILL ORGANIC L 4 2 I I ae LEADER!! MATTER A MINIMUM OF 6 INCHES INTO TOPSOIL. 1 12. FERTILIZE ALL TREES AND SHRUBS WITH'AGRIFORM'PLANTING TABLETS. QUANTITY PER MANUFACTURER'S RECOMMENDATIONS. a� RUBBER CINCH TIE 13. ALL PLANTING BEDS SHALL HAVE A MINIMUM 18"DEPTH OF TOPSOIL. LAWN AREAS SHALL HAVE A MINIMUM 12"DEPTH OF TOPSOIL. SPREAD, PC COMPACT,AND FINE GRADE TOPSOIL TO A SMOOTH AND UNIFORM GRADE 3"BELOW ADJACENT SURFACES OF PLANTER BED AREAS, 1-1/2"BELOW .•• 1 LAWN PA 2"x 2"WOOD STAKE(LENGTH AS ADJACENT SURFACES OF TURF SOD AREAS,AND 1"BELOW ADJACENT SURFACES OF TURF SEED AREAS. CK } 2 I e REQUIRED)-DO NOT PENETRATE ROOTBALL. 14. REUSE EXISTING TOPSOIL STOCKPILED ON THE SITE. SUPPLEMENT WITH IMPORTED TOPSOIL WHEN QUANTITIES ARE INSUFFICIENT. VERIFY 2 I o SEE NOTE 1. SET STAKES PARALLEL TO SUITABILITY AND CONDITION OF TOPSOIL AS A GROWING MEDIUM. PERFORM SOIL TEST/ANALYSIS AND PROVIDE ADDITIONAL AMENDMENT AS CK I CK d a PREVAILING WIND. DETERMINED BY SOIL TESTS. TOPSOIL SHALL BE A LOOSE, FRIABLE,SANDY LOAM, CLEAN AND FREE OF TOXIC MATERIALS, NOXIOUS WEEDS,WEED " " C B 1 a ° o SEEDS, ROCKS, GRASS OR OTHER FOREIGN MATERIAL AND A HAVE A PH OF 5.5 TO 7.0. IF ONSITE TOPSOIL DOES NOT MEET THESE MINIMUM PLANTER BED r 1 CL • STANDARDS, CONTRACTOR IS RESPONSIBLE TO EITHER: " CK I o A)PROVIDE APPROVED IMPORTED TOPSOIL, OR 1 'o p B)IMPROVE ON-SITE TOPSOIL WITH METHODS APPROVED BY THE LANDSCAPE ARCHITECT. K CL CONSTRUCT 2"EARTH BERM AT EDGE OF 15. IF IMPORTED TOPSOIL FROM OFF-SITE SOURCES IS REQUIRED, ENSURE IT IS FERTILE, FRIABLE, NATURAL LOAM,SURFACE SOIL, REASONABLY FREE CALLOUT NUMBERS 1 REFER TO NUMBERED I C o ROOTBALL, FILL TREE RING W/MULCH,AS OF SUBSOIL,CLAY LUMPS, BRUSH,WEEDS AND OTHER LITTER,AND FREE OF ROOTS,STUMPS,STONES LARGER THAN 2 INCHES IN ANY DIMENSION, CALLOUT NOTES r0 NOTES BELOW 2 F: CK oo ° SPECIFIED. AND OTHER EXTRANEOUS OR TOXIC MATTER HARMFUL TO PLANT GROWTH. o A) OBTAIN TOPSOIL FROM LOCAL SOURCES OR FROM AREAS HAVING SIMILAR SOIL CHARACTERISTICS TO THOSE FOUND ON THE PROJECT SITE. 1. PROPOSED TURF AREA '� r....:.4 1 J -� 3"THICK MULCH LAYER, KEEP MULCH 3"AWAY OBTAIN TOPSOIL ONLY FROM NATURALLY,WELL-DRAINED SITES WHERE TOPSOIL OCCURS AT A DEPTH OF NOT LESS THAN 4 INCHES. 0 2. PROPOSED 5'WIDE CONCRETE WALKWAY CK FROM TRUNK. B) REPRESENTATIVE SAMPLES SHALL BE TESTED FOR ACIDITY, FERTILITY,TOXICITY,AND GENERAL TEXTURE BY A RECOGNIZED COMMERCIAL OR r..... 1 3. PROPOSED PARKING AREA A 2 GOVERNMENT AGENCY AND COPIES OF THE TESTING AGENCY'S FINDINGS AND RECOMMENDATIONS SHALL BE FURNISHED TO THE OWNER'S CK 4 REPRESENTATIVE BY THE CONTRACTOR. NO TOPSOIL SHALL BE DELIVERED IN A FROZEN OR MUDDY CONDITION.ACIDITY/ALKALINITY RANGE-PH. 4. PROPOSED BIKE RACK 2 3 : • I z Sue's Subdivision 5.5 TO 7.6. 5. PROPOSED PATIO 1 CL gW :: 1 Bk. 80 Pg. 8571 .� 16. IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE CREATED FROM LANDSCAPE OPERATIONS AND DISPOSE OF PROPERLY OFF 6. PROPOSED COMMUNITY GARDEN AREA r..... CK o PA I o- o FINISHSITE. 7. PROPOSED TRASH ENCLOSURE 1 r o w 17. TREES SHALL NOT BE PLANTED WITHIN THE 10'-0"CLEAR ZONE OF ALL A.C.H.D. STORM DRAIN PIPE, STRUCTURES, OR FACILITIES. TREES SHALL NOT .. .. o PV . 10.0':. -o Q U BE PLANTED WITHIN 5'-0"OF AN A.C.H.D.SIDEWALK. 2 I p w _ // // 18. SEEPAGE BEDS AND OTHER STORM DRAINAGE FACILITIES MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE CONSTRUCTION 5 ::I:' AA/�A/ / COMMERCIAL SLOW RELEASE FERTILIZER AND INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM. CLr .I. �`:�� �.(.,,:�;•�'�<jr. o -III- - - - - TABLETS 19. IN THE EVENT OF A DISCREPANCY, NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY. :r.:.... ..... CD �� . :.�.. 1i? JS PFIli SIDES OF HOLE ROUGH&UNEVEN - IRRIGATION NOTES: PLANT SCHEDULE ...J : BACKFILL WITH APPROVED TOPSOIL AND I r.A 2 �: ''''` `• ~.'';:''`:' I WIDTH WIDTH WIDTH WIDT WIDTH SOIL AMENDMENTS AS SPECIFIED. 1. ALL LANDSCAPED AREAS SHALL HAVE AN AUTOMATIC UNDERGROUND MS QTY KEY BOTANICAL NAME COMMON NAME SIZE NOTES ... OF BALL OF BALL OF BALL OF BALL OF BALL BACKFILL IN 6"LIFTS,WATER EACH LAYER, SPRINKLER SYSTEM WHICH INSURES COMPLETE COVERAGE AND PV .r....:.1. : CA :; ;�..: ;;,• .�.: 5' MIN. DIA. TAMP LIGHTLY AS REQUIRED, BACKFILL PROPERLY ZONED FOR REQUIRED WATER USES. EACH HYDROZONE IS DECIDUOUS TREES I.. 1 TREE RING SOIL EVEN W/TOP OF ROOTBALL, TO BE IRRIGATED WITH SEPARATE INDIVIDUAL STATIONS. DO NOT OVER COMPACT!! r:::::.::::I•. 2 I 2. PLANTER BEDS AND LAWN AREAS ARE TO HAVE SEPARATE 4 AA Acer rubrum'Armstrong' Armstrong Red Maple 2"CAL. B&B Class II-55'H x 20'W H I PA HYDRO-ZONES. SET ROOTBALL ON NATIVE, UNDISTURBED 3 AO Acer rubrum'October Glory' October Glory Maple 2"CAL. B&B Class II-45'H x 30'W � � I 3. POP-UP SPRINKLER HEADS SHALL HAVE A MINIMUM RISER HEIGHT OF 4 . ...C.... 1 3 SOIL INCHES AT LAWN AREAS. 6 GT Gleditsia triacanthos inermis'Sunburst' Sunburst Honeylocust 2"CAL. B&B Class II-60'H x 40-W CD CL BW I 4. PLANTER BEDS ARE TO HAVE DRIP IRRIGATION SYSTEM OR POP-UP NOTES: SPRAY SYSTEM. 6 PC Prunus calleryana'Chanticleer' Chanticleer Pear 2"CAL. B&B Class II-35'H x 15-W C I 1. REMOVE BURLAP,TWINE,AND WIRE BASKET FROM TOP'/3 OF ROOTBALL. REMOVE ALL NAILS,TIES,AND PLASTIC FROM 5. ELECTRONIC WATER DISTRIBUTION/TIMING CONTROLLERS ARE TO BE 1 TICTilia cordata Littleleaf Linden 2"CAL. B&B Class II-60'H x 40'W [ A I ROOTBALL. IF SYNTHETIC BURLAP IS UTILIZED TO WRAP THE ROOTBALL, IT SHALL BE COMPLETELY REMOVED. ONLY PROVIDED. MINIMUM CONTROLLER REQUIREMENTS ARE AS FOLLOWS: ... .I. I BIODEGRADABLE BURLAP SHALL BE LEFT ON THE BOTTOM OF THE ROOTBALL. a. PRECISE INDIVIDUAL STATION TIMING CONIFEROUS TREES CD I 2. THE STAKING OF TREES IS TO BE THE CONTRACTOR'S OPTION; HOWEVER,THE CONTRACTOR IS RESPONSIBLE TO ENSURE b. RUN TIME CAPABILITIES FOR EXTREMES IN PRECIPITATION RATES 1 CA Cedrus atlantica'Fastigiata' Columnar Blue Atlas Cedar 6'HGT. 40'H x 10'W 3 THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAIN STRAIGHT FOR LENGTH OF WARRANTY PERIOD OR 1 YEAR c. AT LEAST ONE PROGRAM FOR EACH HYDROZONE 3 2 AFTER SUBSTANTIAL COMPLETION WHICHEVER IS GREATER. ALL STAKING SHALL BE REMOVED AT THE END OF THE d. SUFFICIENT MULTIPLE CYCLES TO AVOID WATER RUN-OFF 18 JS Juniperus scopulorum'Skyrocket' Skyrocket Juniper 6'HGT. 15'H x 4'W CK "I BW WARRANTY PERIOD. e. POWER FAILURE BACKUP FOR ALL PROGRAMED INDIVIDUAL VALVED 3 PA Picea abies'Cupressina' Cupressina Spruce 8'HGT. 20'H x 6'W 3. IN THE EVENT OF A QUESTION OR LACK OF CLARITY ON THE DRAWINGS,THE CONTRACTOR IS TO NOTIFY THE LANDSCAPE WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO G 3 I I ARCHITECT BEFORE PROCEEDING. PROVIDE WATER TO RESPECTIVE HYDRO-ZONES. 3 PF Pinus flexilis'Vanderwolf Vanderwolf Pine 8'HGT. 26H x 1 O'W 2 .;..�. C B CK I 1 4. LANDSCAPE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT AND OWNER PRIOR TO INSTALLATION OF PLANT 6. INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND ORNAMENTAL TREES AA AO MATERIAL. INSTALLED TO PROVIDE WATER TO RESPECTIVE HYDRO ZONES. 1 1 PC 5. WRAP RUBBER CINCH TIES AROUND THE TREE TRUNKS AND STAKES USING EITHER THE STANDARD OR FIGURE EIGHT TYING 7. THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE 100% HEAD 2 MS Malus x'Spring Snow' Spring Snow Crabapple 2"CAL. B&B Class I 20'H x 15'W PF NO PC o , „ METHOD. SECURE THE TIES TO THE STAKES WITH GALVANIZED NAILS TO PREVENT SLIPPAGE. TO HEAD COVERAGE WITH TRIANGULAR SPACING. 904 13 g . 6. WATER TREE TWICE WITHIN THE FIRST 24 HOURS. 8. SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTO 5 PV Prunus virginiana'Canada Red' Canada Red Chokecherry 2"CAL. B&B Class I-25'H x 15'W -'•'` 1'� :. `•T .^:" ::;r IMPERVIOUS SURFACES(BUILDINGS,SIDEWALKS, DRIVEWAYS,AND 6 r �, �.� . , 7. IN THE EVENT HARDPAN SOILS PREVENT TREE PLANTING AS DETAILED, NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY. ASPHALT AREAS). SHRUBS/PERENNIALS/ORNAMENTAL GRASSES 1 - mmi iR1L --- -- _ s• 15 BW Buxus microphylla var.japonica'Winter Gem' Winter Gem Boxwood #5 3'H x TW Garden CONIFEROUS TREE PLANTING 25 CK Corpus sericea'Kelseyi' Kelsey Dogwood #5 2'H x 4'W Area --.• ' EXISTING ......... I.'.' 4 2 3 TREE TO NOT TO SCALE 28 CL Calamagrostis x acutiflora'Karl Foerster' Karl Foerster Feather Reed Grass #1 5'H x TW .......... .. co F I. .. I ............. CK REMAIN 9 IC Ilex crenata'Sky Pencil' Sky Pencil Holly #5 TH x TW 3 3 JS 3 A A .. r ROOT FLARE TO BE AT SOIL LINE 6 SM Saliva x sylvestris'May Night' May Night Salvia #1 1.5'H x 1.5'W CL 1 CK CK r I 1 PREVAILING WIND DIRECTION 9 TE Thuja occidentalis'Emerald' Emerald Arborvitae #5 1 O'H x 4'W I ..�.••• •....•. r I PV r.......• PC Car Port 1 3 1 r . : ble TC SOIL LINE LANDSCAPE REQUIREMENTS AND COMPLIANCE CALCULATIONS :..: AO CL _ PF 2 c REMOVE DEAD/DAMAGED BRANCHES AN TOTAL PROJECT AREA:29,363 S.F. A MINIMUM OF ONE TREE PER 35 LINEAL FEET SHALL BE .... D l.'.'.'.'.1...:j �, PRUNE TO INTERNATIONAL SOCIETY OF HARDSCAPE AREA: 11,066 S.F. PLANTED ALONG PROPERTY BOUNDARIES. 3 1 2 :.:... '.'.'.. ARBORICULTURE STANDARDS IMPROPERLY BUILDING AREA:7,179 S.F. r...:: :.. .. ..... L � r E 2 .. . BW BW BW .].....r... _ PRUNED TREES AS DETERMINED BY THE TOTAL LANDSCAPE AREA: 11,118 S.F. (37.9%OF SITE) 99 L.F. ON NORTHERN BOUNDARY 3 ::,.,. ..;• . ...r . �I \ LANDSCAPE ARCHITECT)SHALL BE REMOVED TOTAL LANDSCAPE COVERAGE: 5,300 S.F. (47.6%) REQUIRED TREES: 3 JS I °' r.•.•.•.r oK -- AND REPLACED. OPEN SPACE CALCULATIONS. 27 S.F. PROPOSED TREES.3 L DO NOT REMOVE MAIN 78 O ':,:.; N LEADER!! 4 2 r o MINIMUM PLANT SIZES SHALL BE USED: 170.5 L.F. ON NORTHEASTERN BOUNDARY ;.,. o - - RUBBER CINCH TIE SHADE TREES: 2 INCH CALIPER REQUIRED TREES: 5 1 5' CDORNAMENTAL TREES: 2 INCH CALIPER PROPOSED TREES:5 AO Car Port ;.` t:'''.;: ":•,. �� �- 2"x 2"WOOD STAKE LENGTH AS EVERGREEN TREES: 6 FOOT HEIGHT 3 ;��• Car Port Car Po - WOODY SHRUBS. 2 GALLON POT STERN BOUNDARY 3 REQUIRED)-DO NOT PENETRATE ROOTBALL. 110 L.F. ON SOUTHER CL .••-....• 2 x JS '' -• SEE NOTE 1. SET STAKES PARALLEL TO REQUIRED TREES: 3 j..'.'.. 3 ,•:_.r...... . PV �� PREVAILING WIND. A MINIMUM OF ONE CLASS II TREE SHALL BE PLANTED PROPOSED TREES: 3 JS r. 25' 19' 3 O I ,� 3 EVERY 35 LINEAR FEET OF STREET FRONTAGE. EXISTING TREES TO RETAIN: 1 NO. REVISION/ISSUE DATE 9 I CL Z REMOVE TREE WRAP TRUNK PROTECTION, r .. .............. 14 ......... ----------- TE L � AFTER INSTALLATION 65.67 L.F.OF ROAD FRONTAGE ON NORTHERN BOUNDARY 280.75 L.F.ON WESTERN BOUNDARY 19- �25' 19' w W. AVE.) IDAHO A 8 TREES REQUIRED PC STING J CONSTRUCT 2"EARTH BERM AT EDGE OF REQUIRED CLASS ll:2 10 TREES PROVIDED o000000❑❑00000o . ROOTBALL FILL TREE RING W/MULCH, S PROPOSED CLASS II 2 000 I o000 0 1 I 2"RCP 0 ..�.......L._._._.�... ------ .:.:_._.__._ ---- ------- ------ L 12592.80' z SPECIFIED. TOTAL NUMBER OF TREES REQUIRED:26 N GT x C o - w 07 164.75 L.F.OF ROAD FRONTAGE ON SOUTHERN BOUNDARY TOTAL NUMBER OF TREES PROPOSED:27 ------ belli ... .- ------ - ...................: 3 H LAYE EEP MULCH 3 AWAY W. BROADWAY OTAL NUMBER OF TREES EXISTING TO REMAIN: 1 aero,e 1 . LO m 3 THICK MULC R, K ( AVE.)) ��� you No Cap """""""""""" 65.7T Mom• 98' """" JS FROM TRUNK. REQUIRED CLASS II:5 TOTAL NUMBER OF TREES(EXISTING AND PROPOSED):28 - L ....... _ ••••`�.••••••••••••• _ ALL 2 BUSINESS DAY ••••....... o �� - : =• - 25 PROPOSED CLASS II:5 TOTAL NUMBER OF TREE SPECIES REQUIRED:5 CINADVANCE BEFORE S E-L TE 9 45 55 E 164. _ 2 1- TOTAL NUMBER OF TREE SPECIES PROPOSED:7(NOT YOU DIG,GRADE,OR 2 t- Et- fEt-LT EX: -� 2 1��2 6�2 EXCAVATE FOR THE iE - TEH- TES- FINISH GRADE COUNTING EXISTING TREES) voo_f Goo" MARKING OF 1 d 00'���'�'0� UNDERGROUND EP 2 w �w 0000�iQ� ��, 00o MEMBER uralr►Es co EP EP O GT o V/V/V/ /V/ V /V/ / ALL LANDSCAPED AREAS SHALL BE PROVIDED WITH AN o0o SCA o00 o C ti� GT A \ \ \ \ oaao❑000000 9 - H2O H2O H2O H2O 20 H2O�P H21��P -e HET-fie H2O EP H2❑ EP H2O EP H2E EP i E o H2O EP � �Q /��LLJ �/ /� //V V jV////�/ // TABLETS UNDERGROUND AUTOMATIC IRRIGATION SYSTEM. -11 O vwi -III A / SIDES OF HOLE ROUGH&UNEVEN �� E o O III / �/� / \ Ode = ~ 1 1. BACKFILL WITH APPROVED TOPSOIL AND REMOVE ANY PLASTIC, BURLAP, NAILS,OR OTHER O 660.04' Oyu 597.12' III III III III SOIL AMENDMENTS AS SPECIFIED. �I; MATERIALS FROM THE ROOTBALL WHICH MAY LIMITC111 z A o 1 BACKFILL IN 6"LIFTS,WATER EACH LAYER, `` ROOT GROWTH o S 89 v w + 45 55 W 1257.17 TAMP LIGHTLY REQUIRED, BACKFILL Q \ / o � � O WIDTH WIDTH WIDTH WIDTH WIDTH SSMH z y SOIL EVEN W/TOP OF ROOTBALL, '�` CONSTRUCT 2"EARTH BERM TO FORM A WATER O � OF BALL OF BALL OF BALL OF BALL OF BALL ��' � ' � � Rira=2593o SS SS SS SS SS SS SS SS SS SS SS SS SSA SS SS 0 .O o PUS EP EP EP EP EP EP EP EP ��P EP EP 5' MIN. DIA. f •, RETENTION BASIN, FILL BERM WITH MULCH,AS z z O o DO NOT OVER COMPACT!! �► TREE RING - •� ��- SPECIFIED w w v o Tnv=2585.58' M OtiA O SET ROOTBALL ON NATIVE, UNDISTURBED ���• , r Q Q U H o a U o B Oyu �� E SOIL � -_ T MULCH, PER PLANS,3"DEPTH OVER ENTIRE BED. DO Cn � Ca a ti h CLS Control Cap, \- NOT COVER CROWNS OF PLANTS -A-,A- OHP `tJHFq ❑HP ]HP ❑HP ❑HP ❑HP � -P OHP ❑HP ❑HP OHIP ❑HP OHI NOTES: - + PARTNERS a � � `� �' 1. REMOVE BURLAP,TWINE,AND WIRE BASKET FROM TOP%3 OF ROOTBALL. REMOVE ALL NAILS,TIES,AND PLASTIC FROM -III-III- /\\j j = - PROVIDE COMMERCIAL FERTILIZER TABLETS AND 3 LANDSCAPE PLAN _ V // BIOSTIMULANT,AS SPECIFIED, FOR EACH SHRUB reandparmers.com+208-514-3300+1014 S.La Pointe,Boise,Idaho 83706 0 a ROOTBALL. IF SYNTHETIC BURLAP IS UTILIZED TO WRAP THE ROOTBALL, IT SHALL BE COMPLETELY REMOVED. ONLY -III /\\/\ _ o BIODEGRADABLE BURLAP SHALL BE LEFT ON THE BOTTOM OF THE ROOTBALL. - �/ = = BACKFILL WITH APPROVED TOPSOIL AND SOIL 20 0 20 40 60 2. THE STAKING OF TREES IS TO BE THE CONTRACTOR'S OPTION; HOWEVER,THE CONTRACTOR IS RESPONSIBLE TO ENSURE - AMENDMENTS,AS SPECIFIED. BACKFILL IN 6"LIFTS, E -� THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAIN STRAIGHT FOR LENGTH OF WARRANTY PERIOD OR 1 YEAR � _ / / �/ // _ I AFTER SUBSTANTIAL COMPLETION WHICHEVER IS GREATER. ALL STAKING SHALL BE REMOVED AT THE END OF THE WATER EACH LAYER, DO NOT TAMP OR OVER CONNOR SQUARE APARTMENTS SCALE: 1"=20'-0° = III=1111 111= - III- COMPACT. 604 W. BROADWAY AVE. n WARRANTY PERIOD. - 3. IN THE EVENT OF A QUESTION OR LACK OF CLARITY ON THE DRAWINGS,THE CONTRACTOR IS TO NOTIFY THE LANDSCAPE - III"I 117- ARCHITECT BEFORE PROCEEDING. 12 WIDTH OF 12" CONSTRUCT 6"MOUND OF TOPSOIL MERIDIAN ID 83642 A 4. LANDSCAPE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT AND OWNER PRIOR TO INSTALLATION OF PLANT MIN. ROOTBALL MIN. MATERIAL. CONDITIONAL USE PERMIT 5. WRAP RUBBER CINCH TIES AROUND THE TREE TRUNKS AND STAKES USING EITHER THE STANDARD OR FIGURE EIGHT TYING NOTES: METHOD. SECURE THE TIES TO THE STAKES WITH GALVANIZED NAILS TO PREVENT SLIPPAGE. o 6. WATER TREE TWICE WITHIN THE FIRST 24 HOURS. 1. SHRUB SHALL BEAR SAME RELATIONSHIP TO GRADE AS IT DID IN NURSERY. 0 7. IN THE EVENT HARDPAN SOILS PREVENT TREE PLANTING AS DETAILED, NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY. 2. WATER SHRUB TWICE WITHIN FIRST 24 HOURS. LANDSCAPE PLAN 8. FOR TREES LOCATED WITHIN ROADSIDE PLANTERS LESS THAN 8'-0" IN WIDTH, PROVIDE TREE ROOT BARRIER(DEEPROOT 3. THIN BRANCHES AND FOLIAGE BYY3 CE #24-2 OR APPROVED EQUAL). LOCATE ROOT BARRIER AT BACK OF CURB AND EDGE OF SIDEWALK. ALL TREE INSTALLATIONS 4. DO NOT CUT LEADERS TO RETAIN NATURAL SHRUB SHAPE. Ln SHALL CONFORM TO ALL AGENCY APPROVAL REQUIREMENTS, CONTRACTOR SHALL VERIFY PRIOR TO ANY INSTALLATIONS. 5. FOR CONTAINER GROWN PLANTS THAT ARE ROOTBOUND, SPLIT THE ROOTBALL WITH 3 EQUAL SPACED r_ VERTICAL CUTS. N PROJECT SHEET DECIDUOUS TREE PLANTING SHRUB PLANTING 20085 CD CIA 2NOT TO SCALE 3 NOT TO SCALE DATE N 10/22/20 L 1 ° i O DRAWN BY CHECKED BY Q BSS BSS 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 AGENCY REVIEW