Loading...
ElevationsALUMINUMSTOREFRONTMETAL PANELALUMINUMSTOREFRONTHONED MASONRYVENEERALUMINUMSTOREFRONTSPLIT FACEMASONRY VENEERALUMINUMSTOREFRONTALUMINUMCURTAINWALLMETAL PANELMETAL DOOR PAINTEDHONED MASONRYVENEERALUMINUMSTOREFRONTSPLIT FACEMASONRY VENEERALUMINUMSTOREFRONTMETAL PANELALUMINUMSTOREFRONTMETAL DOOR PAINTEDALUMINUMSTOREFRONTMETAL PANELHONED MASONRYVENEERSPLIT FACEMASONRY VENEERALUMINUMSTOREFRONTALUMINUMCURTAINWALLMETAL PANELHONED MASONRYVENEERALUMINUMSTOREFRONTALUMINUMSTOREFRONTALUMINUMSTOREFRONTMETAL DOOR PAINTEDSPLIT FACEMASONRYSPLIT FACEMASONRYSPLIT FACEMASONRYIVIVCZC SUBMITTALPHASE 1 SPLIT FACEMASONRY VENEERALUMINUMSTOREFRONTMETAL PANELALUMINUMSTOREFRONTHONED MASONRYVENEERALUMINUMSTOREFRONTSPLIT FACEMASONRY VENEERALUMINUMSTOREFRONTALUMINUMCURTAINWALLMETAL PANELALUMINUMSTOREFRONTHONED MASONRYVENEERALUMINUMSTOREFRONTSPLIT FACEMASONRYSPLIT FACEMASONRYALUMINUMSTOREFRONTALUMINUMCURTAINWALLMETAL PANELALUMINUMSTOREFRONTSPLIT FACEMASONRYVENEERMETAL PAINTEDDOORMETALPAINTEDDOORMETAL PAINTEDDOORMETAL PAINTEDDOORSPLIT FACEMASONRY VENEERALUMINUMSTOREFRONTALUMINUMCURTAINWALLMETAL PANELHONED MASONRYVENEERALUMINUMSTOREFRONTALUMINUMSTOREFRONTSPLIT FACEMASONRYIVIVCZC SUBMITTALPHASES 1-2 REF. UP A1 A3.11 ______ B3 A3.10 ______ A8.51D4 E3 D1 E1 A3 A3.10 ______ C1 A3.11 ______D1 A3.11 ______ B D 1 2 3 4 6 CA A8.51C3 C1 A8.52 E5 A8.51 B6 A8.51 A5 A8.51 A3 A2 A8.51 A1 A8.51 A8.51 A6 A8.52 B1 C1 C3C5 A8.52 D1 D5 E6 D3 A8.52A3 B3 B5 A1 A8.52A6 A5 A3.02 C1 A3.01 A1 A3.01 C1 A3.02 A5 B4 BAND/CONTEMPORARY CLASSROOM 142 ORCHESTRA CLASSROOM 137 DANCE STUDIO 2 125 DANCE STUDIO 1 124 KILN 122B POTTERY STORAGE 122A ART STUDIO 122 SMALL CONFERENCE 113 LARGE CONFERENCE 115 STORAGE/VAULT 104 PRINCIPALS OFFICE 118 COUNSELING 114 NURSE/HEALTH SUITE 110 SECURITY OFFICE 105 REGISTRAR/BOOK KEEPING 103 COMMON BREAK AREA 109 MAIL AT ADMIN 107 STORAGE 120 PRACTICE 146 PRACTICE 144 PRACTICE 140 PRACTICE 134 PRACTICE 132 COPY CENTER 106 KITCHEN CAFE 121 STORAGE 117 CHOIR / VOCAL CLASSROOM 136 RECEPTION / CLERICAL 102 RESTROOM 130 RESTROOM 131 COUNSELING 116 RESTROOM 111 RESTROOM 112 MECH 147 PRACTICE 133 PRACTICE 135 PRACTICE 139 CLASSROOM 123 RESTROOM 110A DRESSING RM 157 DRESSING RM 158 RR 158A PRACTICE 141 PRACTICE 143 PRACTICE 145 COMMONS 126 VESTIBULE 128 VESTIBULE 101 CORRIDOR 129 CORRIDOR 108 101A 101B 102A 103 104105 120A 120B 109 110 110A 114 111 112 108 113 116 118 117 115 122B 122D 122C 126A 123 124A 125C 125A 128B 128A 132 134 138 142 144 146 129A SFA-06 SFA-07 SFA-07 SFA-05 SFA-05 SFA-06 SFA-08 SFA-05 SFA-03 CWA-01 SFA-04 SFA-01 SFA-06 CWA-02SFA-02 SFA-08 SFA-08 SFA-12 SFA-11 SFA-09 SFA-10 SFA-10 A8.51 B1 B3 A8.53 3 2 A8.53 1 140 A8.92 E1 A8.92 E3 D3 A6.01 ______ _____ A6.01 D1 _____ A6.01 C1 C3 A8.92 ________________ C5 A8.92 ________________ _____ A5.02 D1 SFB-03 SFB-04 SFB-01 SFB-06 _____ A5.02 C1 21' - 11 1/4"6' - 7 1/2"17' - 7 1/2"10' - 3 1/2"31' - 8 3/4"50' - 1 1/2" 12' - 10 1/4"9' - 3 3/4"6' - 5"10' - 6 1/4"10' - 3"14' - 7 1/2"9' - 8 1/4"6' - 4 1/2"6' - 1 3/4"7' - 9 3/4"7' - 3 1/2"9' - 0"7' - 7"21' - 3 1/4"11' - 0"11' - 3 3/4"10' - 10 1/4"6' - 5"7' - 0 1/2"13' - 8 1/2"53' - 2 1/2"35' - 9 1/2" 6' - 11 1/4"9' - 6 3/4"7' - 11"16' - 11"12' - 2 1/4"6' - 2 3/4"3' - 7"5' - 8 1/4"12' - 10 3/4"15' - 5 1/4"17' - 6 1/2"31' - 0 1/2"26' - 11 1/4"5' - 2 1/2"27' - 1 3/4"11' - 6 1/2"57' - 11 3/4"4' - 11 1/4"10' - 3 1/2"10' - 4"6' - 2 1/4"9' - 3 1/4"9' - 5 1/2"18' - 5 1/2"8' - 1 1/4"8' - 5 1/2"9' - 9 1/2"2' - 3 3/4"9' - 7 1/4"1' - 1 1/4"12' - 11 1/2"9' - 10 1/4"10' - 5 1/2"12' - 11 1/2"23' - 3 1/4"1' - 4"11' - 7 1/2"10' - 0 3/4"8' - 6"53' - 9 1/4"49' - 7"12' - 11 1/4" 20' - 2"8' - 0 1/4"35' - 7 1/4" 19' - 2 1/4" 7' - 2 1/4" 36' - 5 1/4" SIM SIM A8.51 C4 A3.05 A1 102B 123A 141 139 135 133 B.4 C.6 C.8 D.4 E E.9 1.8 1.9 2.1 2.4 3.2 3.3 3.8 4.2 4.3 4.5 5 CUST 127 127 130 131 148 147 ELECTRICAL 148 125B 124B 124C 124D ART STORAGE 123A 126B 396 143 PRACTICE 138 157 158 157A 158A RR 157A 125B 136 137 A8.53 1 SIM A8.53 2 SIM 3 SIM CWA-03 S36S S36SS36S S36 S36S S36 S36 S66S S36 X-S60B X-S60BX-S60B S36S36 X-S60B S36S S36S S29S29 M80 S36S36 S29 M80 S36S36 S86 S66 S86 S36 S36S36 S36 S36 S36 S36 S36 S66 S36 S36 S36 M80 S29 M80 S29 S36S66S66 S66 S66 X-S60B X-S60B X-S60B S36 S66 S66 A8.51 B3 B1 S36 S66 S36 SS63 SS63SS63 S27 S27 S30S S27 S36 X-M12 S29S29 S29 S36 S27S36 S30S S27 S30S S30S S36 X-M12S29 S28 S36S36 S36S36 S38S38S38 S36S36 S36S36 S36S36 S60S S66 S36S36 S38 S36 S30S S36 S60S S60S S36S36 S30S S30S S61 S60S S60S S30S S36 S30S S60S X-S60B.1 X-S60B.1 X-M12 S29 X-S60B X-S60B D.9 A5.02 1 4 5 2 A5.02 3 A5.02 6 A5.02 20 21 17 19 A5.02 18 S36 S36 2' - 6" 2' - 6" 2' - 6"26' - 3 3/4"27' - 8 3/16"25' - 11 3/16"21' - 8 5/8"10 1/8"11' - 0 1/4"22' - 9 3/8"1' - 10 15/16"4' - 5 13/16"16' - 5 11/16"12' - 8 3/8"2' - 7 1/2"4' - 7 1/2"1' - 1 5/8"23' - 3 3/16"F 21' - 10 9/16"10' - 7 5/8"14' - 3 1/2"18' - 3 5/16"5' - 2 7/16"5' - 4 7/16"15' - 0 3/4"10' - 10 9/16"1' - 0 3/16"35' - 0 3/8"8 13/128"20' - 3 3/8"8' - 0"8' - 0"2' - 8"12' - 0"6' - 8"4' - 0"5' - 4"4' - 0"8' - 0"8' - 0"3' - 9 7/8"5' - 1 143/256"8' - 0"18' - 10 81/256"12' - 0"23' - 9 175/256"14' - 8"6' - 0 81/256"12' - 8"16' - 0"17' - 4"12' - 0"7' - 9 7/8"12' - 0"3' - 1 7/8"3' - 6 3/4"14' - 8"12' - 0"14' - 8"12' - 0"14' - 11 1/8"S36 122A 139' - 1 125/128" 10 1/8" E3 A2 9' - 10 11/16" 38' - 0" 4' - 8" _____ A6.01 C5 _____ A5.02 D6 105113.B (14) 105113.B (6) 105113.B (10) 105113.B 105113.B 119 (8) (13)10 1/8"91' - 1 7/8"9' - 10 3/8"102' - 5 7/8"1' - 6 1/8"10 3/128"10 1/8"90' - 0"1' - 1 7/8"10' - 8 1/2"1 1/2"22' - 5"18' - 7 161/256"11 5/8"62' - 7 125/128"10 3/128" 105113.B(5) FLOOR DRAIN. COORDINATE WITH PLUMBING DRAWINGS.FD STEEL STUD WALL AND GYPSUM BOARD WALL. COORDINATE WITH WALL TYPES. HI-R CONCRETE MASONRY UNIT WALL. RE: WALL SECTIONS, WALL TYPES, EXTERIOR & INTERIOR ELEVATIONS. COORDINATE WITH STRUCTURAL DRAWINGS. NEW PAINTED SEMI-RECESSED FIRE EXTINGUISHER CABINET AND EXTINGUISHER. PROVIDE POTTER ROEMER CABINET #1700 DOOR TYPE 'A' AND MULTI- PURPOSE DRY-CHEMICAL U.L. RATED MP10 4A-60BC (10LB.) OR EQUAL. REFER TO DRAWING AND BUILDING INFORMATION SHEET FOR MOUNTING HEIGHT. WINDOW TYPE, COORDINATE WITH FRAME TYPES SHEET. WALL TYPE, COORDINATE WITH DRAWING & BUILDING INFORMATION SHEET. DOOR SYMBOL COORDINATE WITH DOOR SCHEDULE XXX XXXx XXXXXXX CR CARD READER LEGEND MASONRY VENEER. RE: WALL SECTIONS, WALL TYPES, EXTERIOR & INTERIOR ELEVATIONS. COORDINATE WITH STRUCTURAL DRAWINGS. CONCRETE MASONRY UNIT (CMU) WALL. RE: WALL SECTIONS, WALL TYPES, EXTERIOR & INTERIOR ELEVATIONS. COORDINATE WITH STRUCTURAL DRAWINGS. GENERAL NOTES 1. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FACE OF STUDS FOR GWB WALLS / PARTITIONS OR FACE OF FINISHED MASONRY FOR CMU. 2. RE: ROOM FINISH SCHEDULE AND FINISH FLOOR PLANS FOR MATERIAL AND FINISH INFORMATION. 3. UNLESS NOTED OTHERWISE ALL GWB WALLS SHALL HAVE A 4" STUD FRAME RETURN AT ALL DOOR AND WINDOW JAMBS. 4. RE: INTERIOR ELEVATIONS FOR LOCATION OF FIXTURES NOT NOTED ON THIS SHEET. 5. RE: SHEETS G2.01 AND G2.02 FOR BUILDING OCCUPANCY PLAN. 6. FOR GLAZING RECEIVING WINDOW TREATMENTS, COORDINATE WITH SPECIFICATION SECTION DIVISION 12 -ROLLER WINDOW SHADES AND FLOOR FINISH PLAN. 7. FOR WALL TYPES COORDINATE WITH ENLARGED PLANS, AND DRAWING & BUILDING INFORMATION SHEET. 8. RE: ACCESSIBILITY COMPLIANCE SHEET FOR TYPICAL ACCESSIBILITY CLEARANCE AND COMPLIANCE REQUIREMENTS AND MISCELLANEOUS MOUNTING HEIGHTS OF TOILET ACCESSORIES. 9. PROVIDE BACKING BEHIND TYPICAL SURFACE MOUNTED EQUIPMENT AND/OR FIXTURES. SEE TYPICAL MOUNTING PLATE ELEVATION DETAIL ON INTERIOR DETAILS SHEET. 10. PROVIDE BACKING AND STRUCTURAL SUPPORT FOR ALL MAJOR EQUIPMENT. COORDINATE WITH EQUIPMENT MANUFACTURERS SUBMITTALS. 11. RE: DOOR HARDWARE SPECIFICATIONS AND DOOR SCHEDULE FOR HARDWARE GROUP INFORMATION. 12. RE: DOOR SCHEDULES AND FRAME TYPES SHEET FOR DOOR TYPES. 13. PROVIDE GROMMETS AT EACH WORK STATION SURFACE OR COMPUTER STATION WITH OPEN KNEE SPACE BELOW COUNTER. 14. AT ALL OUTSIDE EXPOSED COUNTERTOP CORNERS PROVIDE 1 1/2" RADIUS. P r o j e c t : S h e e t : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : E D C B A 1 2 3 4 5 6 6/4/2020 4:46:00 PMIDAHO FINE ARTS ACADEMY 915 EAST CENTRAL DRIVE MERIDIAN, ID 83642 LEVEL 01 -FLOOR PLAN 19008 MB Checker 5/11/2020 A2.0130% CD PACKAGE1/8" = 1'-0"A2.01 A1 LEVEL 01 - FLOOR PLAN REFERENCE NOTES KEYNOTES 105113.B "KNOCKED-DOWN, DOUBLE-TIER METAL LOCKERS"NORTH DWREF.DN A1 A3.11 ______ B3 A3.10 ______ A3 A3.10 ______ C1 A3.11 ______D1 A3.11 ______ B D 1 2 3 4 6 CA A5.01 A3 A5 A5.01 B4 A3.02 C1 A3.01 A1 A3.01 C1 A3.02 A5 A5.01D5 D3 SFA-15 SFA-16 SFA-17 SFA-16 SFA-15 SFA-15 SFA-16 SFA-15 SFA-18SFA-16SFA-17SFA-16SFA-15SFA-18SFA-16SFA-15SFA-18SFA-16SFA-17SFA-18SFA-15SFA-16SFA-18 D3 A6.01 ______ _____ A6.01 D2 _____ A6.01 C3 _____ A6.01 C2 204 205C 205A 205D 206A 214 215 208 207 206B 221 217 220A220 222 224 223 225 227 228 226 _____ A5.01 D1 _____ A5.02 D3 1' - 0" 21' - 6 3/4" 7 3/4" 2 1/2" 40' - 11"38' - 5 1/2"38' - 0" 8' - 0" 2' - 4 3/4"3' - 8 3/4"17' - 3 3/4"4' - 9 1/4"1' - 4 3/4"6' - 6 3/4"11' - 4 1/2"2 3/4"17' - 1"9 1/4"5' - 3"5' - 0 3/4"1 1/4"7"17' - 7 1/4"5' - 8 3/4"9' - 9"7' - 0 1/2"11' - 5"4' - 10 1/4"5' - 6 1/2"62' - 11 1/4"16' - 11 1/4"7' - 9"7' - 4 3/4"11' - 5 1/4"5' - 2 1/2"5' - 2 1/2"12' - 10 1/4"5' - 11 1/2"11' - 1 3/4"3 3/4"10' - 5 1/2"7' - 7 1/2"11' - 3 3/4"16' - 7 3/4"5' - 5"10' - 1 1/4"14' - 0 1/4"24' - 10"30' - 0 1/4"12' - 8 3/4"13' - 0 1/2"4' - 10 3/4"9' - 5 3/4"35' - 5" 8' - 5"3' - 2"33' - 5 1/4" 28' - 10 1/4"17' - 9 3/4"8' - 5"3' - 2"4' - 6 3/4"15' - 3 3/4" 3' - 9" 55' - 0 3/4"7' - 10" 38' - 2 1/2" 2' - 3 1/2" 7' - 4 1/4" 4 1/8" 43' - 3 3/4" 4 1/8" 7' - 9 1/2" 7 3/8" 1' - 4" 11" 38' - 3 3/8" 6' - 5"11' - 2 1/4" 1' - 10" 1' - 8 1/4" 8' - 0 3/4"43' - 10 3/4"8' - 5" 1' - 4" 2' - 0"36' - 2 1/2" 5' - 4 1/2"12' - 9 1/4"13' - 4 1/4" 3 3/4" 4' - 8 1/2"33' - 0" A1 A8.53 B3 A8.53B6 A8.53A3 A8.53 A4 A1 203 202 201 211C 211A 211B 210 209 OPP SIM SIM SIM SIM OPP SIM SIM SIM SIM SFA-17 SFA-18 SFA-16 SFA-18 SFA-16 SFA-15 SFA-18 SFA-16 SFA-18 SFA-17 SFA-16 SFA-18 SFA-15 SFA-18 SFA-16 SFA-18 SFA-16 SFA-15 SFA-18 SFA-16 SFA-19 A8.53A3 A1 A8.53A3 A1 A8.53 A1 A8.53 B5 A8.53 A3 A1 A8.53 B3 A8.53 B3 A1 A1 SIM A8.53B5 SIM 3' - 4"2' - 8"3' - 4" A3.05 A12' - 2 1/4"3' - 2" 2' - 10 3/8" B.4 C.6 C.8 D.4 E E.9 1.8 1.9 2.1 2.4 3.2 3.3 3.8 4.2 4.3 4.5 5 CLASSROOM 202 CLASSROOM 204 PREP 205A SCIENCE LAB 205 CLASSROOM 206 CLASSROOM 207 CLASSROOM 208 CLASSROOM 209 CLASSROOM 210 CLASSROOM 201 SPED 221 CLASSROOM 222 STORAGE 220 MECHANICAL 220A CLASSROOM 224 CLASSROOM 226 PRACTICE 228 PRACTICE 227 PRACTICE 225 PRACTICE 223 CORRIDOR 216 RESTROOM 219 RESTROOM 218RESTROOM 217TECH 215 CUST 214 CORRIDOR 213 STORAGE 203 1941 SF BLACK BOX 211 STORAGE 205B A5.01 B1 B2 219 218 205B D.9 A5.02 9 7 810 A5.02 11 13 1214 A5.02 15 16 X-S60IMP X-S60IMP S29 M80 S29 S36 S38S38S38S38 S36S36 S38S38 S36 S36S36S36 S38 S36 S38S38S38 S36 X-S60IMP X-S60IMP S36 S38 S36 S36 S66 S28S28S28 S38 S36 S36 X-S60IMP S36S36 S36S36 S36S36 S36S36 S29S29S29S29S29S29 S36 S36 S36 S38S38S38 S66 S68 S27 S38 S28S36S27 S36 M80 S39 S39M80S39 S36S36S36 S36S36S36S36 S36S36S36 S36S36 S39S39S39 X-S60IMP X-S60IMP X-S60IMP X-M12 X-S60BX-S60B S36 SS63SS63 SS63 X-S60B S66 S36S36 S36 S36 S39S39 S36 S36S36S36 S38S38S38S38 S38S38 S36S36 S36 S38S38S38S38 X-S60B.1 S36S36S36 S66 S38S38 S38 S38 S36 S66 S36S36 S36 X-S60B.1X-M12S29 X-M12 S36S36S36 S36S36 S36 S36 S36 7' - 10 3/16" F 26' - 3 3/4"27' - 8 3/16"25' - 11 3/16"21' - 8 5/8"10 1/8"11' - 0 1/4"22' - 9 3/8"1' - 10 15/16"4' - 5 13/16"16' - 5 11/16"12' - 8 3/8"2' - 7 1/2"4' - 7 1/2"1' - 1 5/8"23' - 3 3/16"9' - 0"2' - 0"4' - 0"2' - 0"2' - 0"8' - 0"8' - 0"3' - 0"4' - 0"4' - 0"2' - 0"3' - 0"4' - 0"8' - 0"2' - 0"2' - 0"8' - 0"3' - 0"2' - 0"2' - 0"4' - 0"3' - 1 7/8"21' - 10 9/16"10' - 7 5/8"14' - 3 1/2"18' - 3 5/16"5' - 2 7/16"5' - 4 7/16"15' - 0 3/4"10' - 10 9/16"1' - 0 3/16"35' - 0 3/8"8 13/128" 2' - 1 7/8" 2' - 0" 2' - 0"4' - 0"2' - 0"8' - 0"9' - 0" 2' - 0" 2' - 0"12' - 0"7' - 0"4' - 0"3' - 0"2' - 0"7' - 0"8' - 0"2' - 0"4' - 0" 2' - 0" 2' - 0"5' - 0"8' - 0"8' - 0"4' - 0"2' - 0"12' - 0"2' - 0"4' - 0" 2' - 0" 2' - 0"12' - 0"3' - 0"2' - 0"5' - 0"4' - 0"2' - 0"2' - 0"3' - 0"8' - 0"7' - 0"4' - 0"2' - 0"2' - 0"3' - 0"4' - 0"7' - 0"2' - 0"2' - 0"12' - 0"2' - 1 7/8"7' - 6 3/4"4' - 0"2' - 8"8' - 0"12' - 0"8' - 0"2' - 8"4' - 0"12' - 0"8' - 0"8' - 0"2' - 8"4' - 0"2' - 8"12' - 0"3' - 1 7/8" C2 E3 A2 18' - 4 1/2" 31' - 5 1/2"64' - 10 1/4"27' - 4 1/4" _____ A6.01 B5 6' - 8"10 1/8"1' - 10 1/8"90' - 0"1' - 1 7/8"8' - 4 7/16"1 1/2"11 5/8"63' - 6"1' - 6 1/8"102' - 5 7/8"9' - 10 3/8"1' - 1 7/8"90' - 0"1' - 10 1/8"1' - 10 1/8"138' - 3 109/128"1' - 10 3/128" 18' - 7 161/256" S28S28S28 105113.B (8) 105113.B (17) 105113.B (19) 105113.B (15)105113.B(8) 105113.B(11) 105113.B(11) 105113.B(43) FLOOR DRAIN. COORDINATE WITH PLUMBING DRAWINGS.FD STEEL STUD WALL AND GYPSUM BOARD WALL. COORDINATE WITH WALL TYPES. HI-R CONCRETE MASONRY UNIT WALL. RE: WALL SECTIONS, WALL TYPES, EXTERIOR & INTERIOR ELEVATIONS. COORDINATE WITH STRUCTURAL DRAWINGS. NEW PAINTED SEMI-RECESSED FIRE EXTINGUISHER CABINET AND EXTINGUISHER. PROVIDE POTTER ROEMER CABINET #1700 DOOR TYPE 'A' AND MULTI- PURPOSE DRY-CHEMICAL U.L. RATED MP10 4A-60BC (10LB.) OR EQUAL. REFER TO DRAWING AND BUILDING INFORMATION SHEET FOR MOUNTING HEIGHT. WINDOW TYPE, COORDINATE WITH FRAME TYPES SHEET. WALL TYPE, COORDINATE WITH DRAWING & BUILDING INFORMATION SHEET. DOOR SYMBOL COORDINATE WITH DOOR SCHEDULE XXX XXXx XXXXXXX CR CARD READER LEGEND MASONRY VENEER. RE: WALL SECTIONS, WALL TYPES, EXTERIOR & INTERIOR ELEVATIONS. COORDINATE WITH STRUCTURAL DRAWINGS. CONCRETE MASONRY UNIT (CMU) WALL. RE: WALL SECTIONS, WALL TYPES, EXTERIOR & INTERIOR ELEVATIONS. COORDINATE WITH STRUCTURAL DRAWINGS. GENERAL NOTES 1. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO THE FACE OF STUDS FOR GWB WALLS / PARTITIONS OR FACE OF FINISHED MASONRY FOR CMU. 2. RE: ROOM FINISH SCHEDULE AND FINISH FLOOR PLANS FOR MATERIAL AND FINISH INFORMATION. 3. UNLESS NOTED OTHERWISE ALL GWB WALLS SHALL HAVE A 4" STUD FRAME RETURN AT ALL DOOR AND WINDOW JAMBS. 4. RE: INTERIOR ELEVATIONS FOR LOCATION OF FIXTURES NOT NOTED ON THIS SHEET. 5. RE: SHEETS G2.01 AND G2.02 FOR BUILDING OCCUPANCY PLAN. 6. FOR GLAZING RECEIVING WINDOW TREATMENTS, COORDINATE WITH SPECIFICATION SECTION DIVISION 12 -ROLLER WINDOW SHADES AND FLOOR FINISH PLAN. 7. FOR WALL TYPES COORDINATE WITH ENLARGED PLANS, AND DRAWING & BUILDING INFORMATION SHEET. 8. RE: ACCESSIBILITY COMPLIANCE SHEET FOR TYPICAL ACCESSIBILITY CLEARANCE AND COMPLIANCE REQUIREMENTS AND MISCELLANEOUS MOUNTING HEIGHTS OF TOILET ACCESSORIES. 9. PROVIDE BACKING BEHIND TYPICAL SURFACE MOUNTED EQUIPMENT AND/OR FIXTURES. SEE TYPICAL MOUNTING PLATE ELEVATION DETAIL ON INTERIOR DETAILS SHEET. 10. PROVIDE BACKING AND STRUCTURAL SUPPORT FOR ALL MAJOR EQUIPMENT. COORDINATE WITH EQUIPMENT MANUFACTURERS SUBMITTALS. 11. RE: DOOR HARDWARE SPECIFICATIONS AND DOOR SCHEDULE FOR HARDWARE GROUP INFORMATION. 12. RE: DOOR SCHEDULES AND FRAME TYPES SHEET FOR DOOR TYPES. 13. PROVIDE GROMMETS AT EACH WORK STATION SURFACE OR COMPUTER STATION WITH OPEN KNEE SPACE BELOW COUNTER. 14. AT ALL OUTSIDE EXPOSED COUNTERTOP CORNERS PROVIDE 1 1/2" RADIUS. P r o j e c t : S h e e t : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : E D C B A 1 2 3 4 5 6 6/4/2020 4:46:08 PMIDAHO FINE ARTS ACADEMY 915 EAST CENTRAL DRIVE MERIDIAN, ID 83642 LEVEL 02 -FLOOR PLAN 19008 MB Checker 5/11/2020 A2.0230% CD PACKAGE1/8" = 1'-0"A2.02 A1 LEVEL 02 - FLOOR PLAN REFERENCE NOTES KEYNOTES 105113.B "KNOCKED-DOWN, DOUBLE-TIER METAL LOCKERS"NORTH T2LA GENERAL NOTES A. COORDINATE WITH MECHANICAL AND ELECTRICAL DRAWINGS FOR LOCATION AND NUMBER OF OTHER ROOF PENETRATIONS (I.E., VENT STACKS, VENT PIPES, CONDUIT PENETRATIONS, ETC.), FLASH ALL PENETRATIONS WEATHER TIGHT. COORDINATE WITH ROOF DETAILS. B. SLOPE ALL CRICKETS AS SHOWN AT A SLOPE OF 1/2" PER FOOT, EXCEPT WHERE NOTED. C. PROVIDE BUILT-UP TAPERED INSULATION ROOF CRICKETS AT ALL CURB LOCATIONS TO ALLOW POSITIVE DRAINAGE AND PREVENT PONDING. D. ALL METAL ROOF FLASHING DETAILS SHALL BE PER MANUFACTURER'S RECOMMENDATIONS AND REVIEWED BY THE ARCHITECT FOR DESIGN INTENT. E. COORDINATE ROOF DRAIN SUMP LOCATION AND REQUIRED PENETRATION WITH PLUMBING DRAWINGS. F. REVIEW STRUCTURAL DRAWINGS FOR SLOPED VERSES FLAT DECK. G. SEE STRUCTURAL FRAMING PLAN FOR ROOF DECK HEIGHTS TO ESTABLISH ROOF SLOPES AND ROOF MEMBER LOCATIONS. H. COORDINATE WITH ELECTRICAL, MECHANICAL, AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION ON ROOF PENETRATIONS. I. ALL FINISHED ROOF SLOPES TO ACHIEVE A MINIMUM OF 1/4" PER FOOT SLOPE IN DIRECTION INDICATED. IT IS THE RESPONSIBILITY OF THE ROOFING CONTRACTOR TO INSTALL ROOFING COMPONENTS TO MEET THESE REQUIREMENTS. J. ALL ROOF MEMBRANE ACCESSORIES SHALL COME FROM THE SAME MANUFACTURER OR FROM A SUPPLIER APPROVED BY THE MEMBRANE MANUFACTURER. ALL ROOF COVERING, MATERIAL AND ACCESSORIES SHALL BE COMPATIBLE. K. PROVIDE WALK PADS ON ALL SIDES OF MECHANICAL EQUIPMENT, CURBS, DOORS AND WHERE INDICATED. L. PREFABRICATED CURBS SHALL BE INSTALLED AND SET LEVEL. M. ALL DIMENSIONS ARE FOR GENERAL ARRANGEMENT AND LOCATION ONLY. ACTUAL REQUIREMENTS AND DIMENSIONS ARE TO BE VERIFIED AND COORDINATED WITH EQUIPMENT, OTHER CONSTRUCTION TRADES, SHOP DRAWINGS AND STRUCTURAL FRAMING. N. CONSTRUCTION SHALL BE IN FULL COMPLIANCE WITH ALL CURRENT LOCAL CODES AND REGULATIONS IN EFFECT AT THE TIME OF AGREEMENT BETWEEN OWNER AND CONTRACTOR. O. AT AREAS WHERE STRUCTURAL ROOF DECK IS LEVEL, PROVIDE SLOPED INSULATION TO ACHIEVE REQUIRED SLOPE. P. DETAILS IN THE PROJECT DRAWING ARE SHOWN AT SPECIFIC LOCATIONS AND ARE INTENDED TO SHOW GENERAL REQUIREMENTS THROUGHOUT. Q. RE: EXTERIOR ELEVATIONS FOR PARAPET HEIGHTS AND RIDGE HEIGHTS. R. RE: SHEET GX.XX FOR ROOF ASSEMBLIES. A1 A3.11 ______ B3 A3.10 ______ A3 A3.10 ______ C1 A3.11 ______D1 A3.11 ______ B D 1 2 3 4 6 CA A5.01 A3 A5 A5.01 B4 A3.02 C1 A3.01 A1 A3.01 C1 A3.02 A5 A5.01D5 D3 D3 A6.01 ______ D2 A2.93 ________________ E3 A2.93 ________________ A1 A8.53 B3 A8.53B6 A8.53A3 A8.53 A4 A1 A8.53 B5 A3.05 A1 _____ A2.93 D5 SIM. 1/2" / 12"1/2" / 12" 1/2" / 12" 1/2" / 12" 1/2" / 12" 1/2" / 12" 1/2" / 12"1/2" / 1'-0"1 / 2 " / 1 '- 0 " 1/2" / 1'-0"1/2" / 1'-0"1 / 2 " / 1 '- 0 "1/2" / 1'-0"1/2 " / 1'-0" 1/2 " / 1'-0" 1 / 2 " / 1 '- 0 " 1/2 " / 1'-0"1/2" / 1'-0"1/2" / 1'-0"1/2" / 1'-0"1/2" / 1'-0"1 / 2 " / 1 '- 0 "1/2" / 1'-0"1/2" / 1'-0"1 /2" / 1 '-0" 1 / 2 " / 1 '- 0 "1/2" / 1'-0"B.4 C.6 C.8 D.4 E E.9 1.8 1.9 2.1 2.4 3.2 3.3 3.8 4.2 4.3 4.5 5 44' - 3 3/4" A5.01 B1 B2 B2 A2.91 ________________ D.9 A5.02 9 7 810 A5.02 11 13 1214 A5.02 15 16 F 26' - 3 3/4"27' - 8 3/16"25' - 11 3/16"21' - 8 5/8"10 1/8"11' - 0 1/4"22' - 9 3/8"1' - 10 15/16"4' - 5 13/16"16' - 5 11/16"12' - 8 3/8"2' - 7 1/2"4' - 7 1/2"1' - 1 5/8"23' - 3 3/16"21' - 10 9/16"10' - 7 5/8"14' - 3 1/2"18' - 3 5/16"5' - 2 7/16"5' - 4 7/16"15' - 0 3/4"10' - 10 9/16"1' - 0 3/16"35' - 0 3/8"8 13/128" C2 E3 A2 RIDGERIDGE_____ A2.91 E3 TYP. _____ A2.91 E3 TYP. _____ A2.91 E3 TYP. AREA OF TAPERED ROOF INSULATION ROOF DRAIN SUMP AREA OF FLAT ROOF INSULATION FLEXIBLE WALKWAY. RE: SPEC AREA OF ROOF CRICKET LEGEND P r o j e c t : S h e e t : P r o j e c t N o : D r a w n B y : C h e c k e d B y : D a t e : R e v i s i o n s : S h e e t N o : E D C B A 1 2 3 4 5 6 6/4/2020 4:46:13 PMIDAHO FINE ARTS ACADEMY 915 EAST CENTRAL DRIVE MERIDIAN, ID 83642 ROOF -PLAN 19008 MB Checker 5/11/2020 A2.0330% CD PACKAGEREFERENCE NOTES KEYNOTES 1/8" = 1'-0"A2.03 A2 ROOF PLAN NORTH