Loading...
2019-40_R&A_CZC-DR_L1.0_Landscape-PlanS00°26'40''W 222.48'N88°25'08''W 182.44'N88°25'08''W 182.44'5'-0" WIDE PUBLIC UTILITY, DRAINAGE & LANDSCAPE EASEMENT25'-0" WIDE PUBLIC UTILITY, DRAINAGE & LANDSCAPE EASEMENT N89°54'09''W 158.92'20'-0" WIDE PUBLIC UTILITY, DRAINAGE & LANDSCAPE EASEMENTS00°26'40''W 190.03'N89°54'09''W 182.40'5ZS1PC3ZS3CC10ER17CS6RH10CD9SS8RH10RH10CD18SS6RH36PV10JS19PE4VM4RH3VM3RH10VM3RH10CS15JS5ER6CS11HS10PE6PV6PV8CD12HS12PE1PC4RH7SS8HS6AR10CD13PV3ZS1AR5CD3PVPLANT SCHEDULEQTYKEYBOTANICAL NAMECOMMON NAMESIZENOTESDECIDUOUS SHADE TREES7ARAcer rubrum 'Frank Jr.'Redpointe Maple2" CAL. B&BClass II - 45' H x 30' W11ZSZelkova Serrata 'Village Green'Japanese Zelkova2" CAL. B&BClass II - 40' H x 40' WORNAMENTAL TREES3CCCercis canadensis 'Forest Pansy'Forest Pansy Redbud2" CAL. B&B20' H x 20' W2PCPyrus calleryana 'Aristocrat'Aristocrat Flowering Pear2" CAL. B&B20' H x 12' WSHRUBS/PERENNIALS/ORNAMENTAL GRASSES33CBCornus sericea 'Flaviramea'Yellow Twig Dogwood#56' H x 6' W45CDCotoneaster dammeri 'Coral Beauty'Coral Beauty Cotoneaster#21' H x 5' W17ERErianthus ravennaeHardy Pampas Grass#210-12' H x 4' W31HSHelictotrichon sempervirensBlue Oat Grass#22' H x 3' W29JSJuniperus squamata 'Blue Star'Blue Star Juniper#12' H x 4' W67PVPanicum virgatum 'Heavy Metal'Heavy Metal Blue Switch Grass#25' H x 3' W36PEPerovskia atriplicifolia 'Little Spire'Little Spire Russian Sage#12' H x 2' W44RHRudbeckia hirta 'Indian Summer'Indian Summer Black-Eyed Susan#1;36" o.c.2' H x 2' W39SSSedum 'Autumn Fire'Autumn Fire Sedum#1.5' H x 3' W17VMVinca minor 'Bowles'Dwarf Periwinkle#1; 36" o.c..5' H x 3' WRudbeckia hirta 'Indian Summer'1gallon container - 36" o.c.Vinca Minor "Bowles1 gallon container - 36" o.c.LANDSCAPE LEGENDQUANTITYPLANT IDENTIFICATION KEYTREES AND PLANTS TO BE INSTALLEDCUT EDGE AS DETAILEDPROPERTY LINE (VERIFY)EXISTING VINYL FENCING - SAVE ANDPROTECT2QCMAINTAINED LAWN AREASTURF SOD AND TOPSOIL ASSPECIFIED ( MATCH EXISTINGTURF TYPE )3" CASCADE COMPOST MULCHAT 3" DEPTH OVER TOPSOIL ASSPECIFIEDEXISTING TURF TO REMAINPROPOSED FIELD TURF AREA -SEE ARCHITECTURALDRAWINGSLA-238S T ATE OF IDAHOLICENSED LANDSCAPE A RCHITECT ROD N E Y P. EVANS JR.SCALE:01"= 20'-0"20406020 LANDSCAPE PLANSHEETOF#Sheet NumberDrawing TitleMAY 2020RE20042REJOB NO:DATE:DRAWN BY:CHECKED BY:SealsCOPYRIGHTAll rights reserved.Reproduction withoutwritten permission ofArchitecture Northwest, PAis unlawful and subject tocriminal prosecution.RANDALL HAVERFIELD A.I.A.224 16th AVENUE SOUTHNAMPA, IDAHO 83651OFFICE: (208) 467-3377FAX: (208)467-4343www.arcnw.comARCHITECTUREN O R T H W E S T, P APRELIMINARYNOT FORCONSTRUCTIONSCHEMATICDESIGNPACKAGEDESCRIPTIONDATEMRK 1 2 3 07/20/20 CITY COMMENTS 07/20/20 OWNER REVISIONS 07/27/20 OWNER REVISIONS TO PARKING 1649 & 1703 EAST PINE STREET, MERIDIAN, IDAHO 83642 ROCK & ARMOR PHYSICAL THERAPY & SPORTS PERFORMANCE N E W F A C I L I T Y F O R:PRELIMINARYNOT FORC O N S T R U C T I O NCALL 2 BUSINESS DAYSIN ADVANCE BEFOREYOU DIG, GRADE, OREXCAVATE FOR THEMARKING OFUNDERGROUNDMEMBER UTILITIES Call before you dig.Know what's below.RCopyright 2020All rights reserved. Reproduction or use in any form or by any means without written permission of Rodney Evans + Partners, PLLC. is unlawful and subject to criminal prosecution.reandpartners.com + 208-514-3300 + 1014 S. La Pointe, Boise, Idaho 83706LANDSCAPE ARCHITECTURE + URBAN DESIGN + LAND PLANNING + GRAPHIC COMMUNICATION + PROJECT MANAGEMENTPROJECT INFORMATIONLANDSCAPE REQUIREMENTSTOTAL PROPERTY SIZE = 79,192S.F. - 1.818 ACRESBUILDING COVERAGE: 15,314 S.F.HARDSCAPE COVERAGE: 34,708 S.F.LANDSCAPE COVERAGE: 16,225 S.F.NUMBER OF PARKING STALLS PROVIDED: 53 STANDARD STALLS0 COMPACT STALLS3 ADA STALLSTOTAL: 56 STALLSNUMBER OF BICYCLE PARKING SPACES REQUIRED:(1 STALLS/10 REQUIRED STALLS) = BICYCLE STALLSNUMBER OF BICYCLE PARKING SPACES PROVIDED:PROPOSED ONE RACK (ONE RACK = 5 STALLS)TOTAL NUMBER OF TREES: 23 ( ADD'T 20 EXISTING TREES)TOTAL NUMBER OF TREE SPECIES: 4 ; 3 SPECIES REQUIREDPROVIDED PARKING LOT TREES - 9LANDSCAPE BUFFER REQUIREMENTS:WEST LANDSCAPE BUFFER190 LIN. FT. ALONG LOCUST GROVE25 FT. WIDTH PARKING BUFFER PROVIDED(25 FT. LANDSCAPE BUFFER REQUIRED)REQUIRED TREES - 5PROVIDED TREES - 5 ( REPLACE 3 DEAD, 1 MISSING AND 1UNHEALTHY AS PER TREE MITIGATION NOTES )NORTH BOUNDARY LANDSCAPE BUFFER301 LIN. FT. ALONG PINE AVE30 (VARIES) BUFFER PROVIDED(25 FT. BUFFER REQUIRED)REQUIRED TREES - 9PROVIDED TREES - 9 (EXISTING-REPLACE 2 DEADFLOWERING PEARS)EAST BOUNDARY LANDSCAPE BUFFER189 LIN. FT.5 FT. WIDTH BUFFER PROVIDED(5 FT. LANDSCAPE BUFFER REQUIRED)REQUIRED TREES - 5PROVIDED TREES - 5SOUTH BOUNDARY LANDSCAPE BUFFER365 LIN. FT.19 FT. BUFFER PROVIDED(10 FT. LANDSCAPE BUFFER REQUIRED)REQUIRED TREES - 10PROVIDED TREES - 13 ( EXISTING PINES)11PLANLANDSCAPECZCLANDSCAPE NOTES:1.CONTRACTOR SHALL REPORT TO LANDSCAPE ARCHITECT ALL CONDITIONS WHICH IMPAIR AND/ORPREVENT THE PROPER EXECUTION OF THIS WORK, PRIOR TO BEGINNING WORK.2.NO MATERIAL SUBSTITUTIONS SHALL BE MADE WITHOUT THE LANDSCAPE ARCHITECT'S PRIORWRITTEN APPROVAL. ALTERNATE MATERIALS OF SIMILAR SIZE AND CHARACTER MAY BECONSIDERED IF SPECIFIED PLANT MATERIALS CAN NOT BE OBTAINED.3.COORDINATE ALL WORK WITH ALL OTHER SITE RELATED DEVELOPMENT DRAWINGS.4.COORDINATE WORK SCHEDULE AND OBSERVATIONS WITH LANDSCAPE ARCHITECT PRIOR TOCONSTRUCTION START-UP.5.ALL PLANT MATERIAL SHALL BE INSTALLED AS PER DETAILS.6.ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR TYPE ANDSIZE SHOWN. PLANTS WILL BE REJECTED IF NOT IN A SOUND AND HEALTHY CONDITION.7.IN THE EVENT OF A PLANT COUNT DISCREPANCY, PLANT SYMBOLS SHALL OVERRIDE SCHEDULEQUANTITIES AND CALL OUT SYMBOL NUMBERS.8.ALL PLANTING BEDS SHALL BE COVERED WITH A MINIMUM OF 3" DEPTH OF CASCADE COMPOST BARKMULCH. APPLY PRE-EMERGENT HERBICIDE PRIOR TO MULCH APPLICATION. SUBMIT SAMPLE FORAPPROVAL.9.ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING AT THE DATEOF ACCEPTANCE BY THE OWNER. REPLACE ALL PLANT MATERIAL FOUND DEAD OR NOT IN A HEALTHYCONDITION IMMEDIATELY WITH THE SAME SIZE AND SPECIES AT NO COST TO THE OWNER.10.FINISH GRADES SHALL PROVIDE A SMOOTH TRANSITION WITH ADJACENT SURFACES AND ENSUREPOSITIVE DRAINAGE IN ACCORDANCE WITH THE SITE CIVIL GRADING PLAN.11.AMEND EXISTING APPROVED TOPSOIL AT A RATIO OF THREE CUBIC YARDS OF APPROVED COMPOSTPER 1000 SQUARE FEET. ROTO-TILL ORGANIC MATTER A MINIMUM OF 6 INCHES INTO TOPSOIL.12.FERTILIZE ALL TREES AND SHRUBS WITH 'AGRIFORM' PLANTING TABLETS. QUANTITY PERMANUFACTURER'S RECOMMENDATIONS.13.ALL PLANTING BEDS SHALL HAVE A MINIMUM 18" DEPTH OF TOPSOIL. LAWN AREAS SHALL HAVE AMINIMUM 12" DEPTH OF TOPSOIL. SPREAD, COMPACT, AND FINE GRADE TOPSOIL TO A SMOOTH ANDUNIFORM GRADE 3" BELOW ADJACENT SURFACES OF PLANTER BED AREAS, 1-1/2" BELOW ADJACENTSURFACES OF TURF SOD AREAS, AND 1" BELOW ADJACENT SURFACES OF TURF SEED AREAS.14.REUSE EXISTING TOPSOIL STOCKPILED ON THE SITE. SUPPLEMENT WITH IMPORTED TOPSOIL WHENQUANTITIES ARE INSUFFICIENT. VERIFY SUITABILITY AND CONDITION OF TOPSOIL AS A GROWINGMEDIUM. PERFORM SOIL TEST/ ANALYSIS AND PROVIDE ADDITIONAL AMENDMENT AS DETERMINEDBY SOIL TESTS. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREE OF TOXICMATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS OR OTHER FOREIGN MATERIAL AND AHAVE A PH OF 5.5 TO 7.0. IF ONSITE TOPSOIL DOES NOT MEET THESE MINIMUM STANDARDS,CONTRACTOR IS RESPONSIBLE TO EITHER:A) PROVIDE APPROVED IMPORTED TOPSOIL, ORB) IMPROVE ON-SITE TOPSOIL WITH METHODS APPROVED BY THE LANDSCAPE ARCHITECT.15.IF IMPORTED TOPSOIL FROM OFF-SITE SOURCES IS REQUIRED, ENSURE IT IS FERTILE, FRIABLE,NATURAL LOAM, SURFACE SOIL, REASONABLY FREE OF SUBSOIL, CLAY LUMPS, BRUSH, WEEDS ANDOTHER LITTER, AND FREE OF ROOTS, STUMPS, STONES LARGER THAN 2 INCHES IN ANY DIMENSION,AND OTHER EXTRANEOUS OR TOXIC MATTER HARMFUL TO PLANT GROWTH.A) OBTAIN TOPSOIL FROM LOCAL SOURCES OR FROM AREAS HAVING SIMILAR SOILCHARACTERISTICS TO THOSE FOUND ON THE PROJECT SITE. OBTAIN TOPSOIL ONLY FROMNATURALLY, WELL-DRAINED SITES WHERE TOPSOIL OCCURS AT A DEPTH OF NOT LESS THAN 4INCHES.B) REPRESENTATIVE SAMPLES SHALL BE TESTED FOR ACIDITY, FERTILITY, TOXICITY, ANDGENERAL TEXTURE BY A RECOGNIZED COMMERCIAL OR GOVERNMENT AGENCY AND COPIES OFTHE TESTING AGENCY'S FINDINGS AND RECOMMENDATIONS SHALL BE FURNISHED TO THEOWNER'S REPRESENTATIVE BY THE CONTRACTOR. NO TOPSOIL SHALL BE DELIVERED IN AFROZEN OR MUDDY CONDITION. ACIDITY/ALKALINITY RANGE - PH. 5.5 TO 7.6.16.IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE CREATED FROM LANDSCAPEOPERATIONS AND DISPOSE OF PROPERLY OFF SITE.17.TREES SHALL NOT BE PLANTED WITHIN THE 10'-0" CLEAR ZONE OF ALL STORM DRAIN PIPE,STRUCTURES, OR FACILITIES.18.STORM DRAINAGE FACILITIES MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURINGTHE CONSTRUCTION AND INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM.19.IN THE EVENT OF A DISCREPANCY, NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY.1.ALL LANDSCAPED AREAS SHALL HAVE AN AUTOMATIC UNDERGROUND SPRINKLER SYSTEM WHICHINSURES COMPLETE COVERAGE AND PROPERLY ZONED FOR REQUIRED WATER USES. EACHHYDROZONE IS TO BE IRRIGATED WITH SEPARATE INDIVIDUAL STATIONS.2.PLANTER BEDS AND LAWN AREAS ARE TO HAVE SEPARATE HYDRO-ZONES.3.POP-UP SPRINKLER HEADS SHALL HAVE A MINIMUM RISER HEIGHT OF 4 INCHES AT LAWN AREAS AND18" AT PLANTER BEDS.4.PLANTER BEDS ARE TO HAVE DRIP IRRIGATION SYSTEM OR POP-UP SPRAY SYSTEM. ANNUALS,PERENNIALS GROUND COVERS OR SHRUB MASSINGS SHALL HAVE A POP-UP SPRAY SYSTEM.5.ELECTRONIC WATER DISTRIBUTION/ TIMING CONTROLLERS ARE TO BE PROVIDED. MINIMUMCONTROLLER REQUIREMENTS ARE AS FOLLOWS:a.PRECISE INDIVIDUAL STATION TIMINGb.RUN TIME CAPABILITIES FOR EXTREMES IN PRECIPITATION RATESc.AT LEAST ONE PROGRAM FOR EACH HYDROZONEd.SUFFICIENT MULTIPLE CYCLES TO AVOID WATER RUN-OFFe.POWER FAILURE BACKUP FOR ALL PROGRAMED INDIVIDUAL VALVED WATERING STATIONS WILLBE DESIGNED AND INSTALLED TO PROVIDE WATER TO RESPECTIVE HYDRO-ZONES.6.INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO PROVIDE WATER TORESPECTIVE HYDRO-ZONES.7.THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE 100% HEAD TO HEAD COVERAGE WITHTRIANGULAR SPACING.8.SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTO IMPERVIOUS SURFACES(BUILDINGS, SIDEWALKS, DRIVEWAYS, AND ASPHALT AREAS).9.PROVIDE MINIMUM (1) QUICK COUPLER VALVE PER EACH (6) AUTOMATIC VALVE ZONES. APPROVEQ.C.V. LOCATIONS WITH LANDSCAPE ARCHITECT.IRRIGATION NOTES:1.ALL AREAS TO BE PLANTED OR HYDROSEEDED SHALL HAVE WEED ABATEMENT OPERATIONSPERFORMED ON THEM PRIOR TO PLANTING OR HYDROSEEDING.2.CONTRACTOR SHALL SPRAY ALL EXPOSED WEEDS WITH “ROUND-UP” (CONTACT HERBICIDE) ORAPPROVED EQUAL.3.DO NOT WATER FOR AT LEAST SEVEN (7) DAYS. REMOVE EXPOSED WEEDS FROM THE SITE.4.CONTRACTOR SHALL OPERATE THE AUTOMATIC IRRIGATION SYSTEM FOR A PERIOD OF FOURTEEN(14) DAYS. AT CONCLUSION OF THIS WATERING PERIOD, DISCONTINUE WATERING FOR THREE TOFIVE (3-5) DAYS.5.APPLY SECOND APPLICATION OF “ROUND-UP” TO ALL EXPOSED WEEDS. APPLY IN STRICTCONFORMANCE WITH MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS. DO NOT WATER FORAT LEAST SEVEN (7) DAYS. REMOVE WEEDS FROM THE SITE.6.IF ANY EVIDENCE OF WEED GERMINATION EXISTS AFTER TWO (2) APPLICATIONS, CONTRACTORSHALL BE DIRECTED TO PERFORM A THIRD APPLICATION.7.AT THE TIME OF PLANTING AND HYDROSEEDING, ALL PLANTING AREAS SHALL BE WEED FREE.WEED ABATEMENT NOTES:1.RETAIN AND PROTECT EXISTING TURF2.RETAIN AND PROTECT EXISTING FLOWERING PEARTREE - PROVIDE A 5'X5' SQ. MULCH BED3.PLANT (2) FLOWERING PEAR TREES - PROVIDE A 5'X5'SQ. MULCH BED4.RETAIN AND PROTECT EXISTING FLOWERING PLUMTREE - PROVIDE A 5'X5' SQ. MULCH BED5.REMOVE (5) SUNBURST HONEYLOCUSTS - (1) IS ASTUMP, (3) ARE DEAD AND (1) IS UNHEALTHY / DYING -REPLACED ALL WITH JAPANESE ZELKOVAS AS SHOWNON PLAN AND PROVIDE A 5'X5' SQ. MULCH BED6.RETAIN AND PROTECT EXISTING AUSTRIAN PINE TREE- PROVIDE A 5'X5' SQ. MULCH BED7.PROPOSED TURF AREA, PATCH BACK AT EXISTINGTURF8.PROPOSED BICYCLE STORAGE9.NOT USED10.PROPOSED TRASH ENCLOSURE11.VISION TRIANGLE12.EXISTING VINYL FENCING - SAVE AND PROTECT13.EXISTING CHAIN LINK FENCING - SAVE AND PROTECT14.PROPOSED 36' x 100' FIELD TURF AREA15. REMOVE EXISTING PINE TREE - REPLACE WITHREQUIRED TERMINAL ISLAND TREE AS NOTEDCALLOUT NOTES #CALLOUT NUMBERSREFER TO NUMBEREDNOTES BELOWTREE PROTECTION NOTES:1.PROTECT THE CRITICAL ROOT ZONE (THE AREA DIRECTLY BELOW THE DRIPLINE OF THE TREE) OF THE TREES TOREMAIN ON SITE BY:a.CONSTRUCTING A TEMPORARY CHAINLINK FENCE AROUND THE CRITICAL ROOT ZONE OF THE TREE TO BEPROTECTED PRIOR TO DEMOLITION, CONSTRUCTION, OR ANY SITE WORK.b.NOT ALLOWING COMPACTION BY EQUIPMENT TRAFFIC DURING CONSTRUCTION OR DURING DEMOLITION.c.NOT ALLOWING CONCRETE TRUCKS TO RINSE WITHIN THE PROTECTION AREA, OR ANYWHERE NEAREXISTING TREE ROOTS OR IN PLANNED PLANTING BEDS AREAS. SEE EROSION AND SEDIMENT CONTROLPLAN FOR APPROVED CONCRETE WASHOUT AREAS.d.NOT STOCKPILING MATERIALS, DEBRIS, OR DIRT WITHIN THE TREE PROTECTION AREA.e.WATERING WITHIN THE CRITICAL ROOT ZONE FROM MID-APRIL TO MID-OCTOBER AT THE RATE OF NOT LESSTHAN THE EQUIVALENT OF 1-1/2" OF WATER OVER THE ENTIRE AREA PER WEEK.f.NOT TRENCHING, EXCAVATING, FILLING, OR OTHERWISE DISTURBING THE SOIL WITHIN THE CRITICAL ROOTZONE.g.ADJUST PROPOSED IMPROVEMENT LOCATIONS AS REQUIRED TO AVOID DAMAGING TREE ROOTS.2.PROTECT THE CROWN AND TRUNK OF TREES TO BE RETAINED BY:a.OPERATING EQUIPMENT IN SUCH A WAY AS TO AVOID CONTACT WITH TREE TRUNKS OR BRANCHES.b.HAVING TREES PRUNED BY A LICENSED ARBORIST.3.ALL TREES THAT ARE DAMAGED, DESTROYED OR REMOVED DURING CONSTRUCTION SHALL BE MITIGATED USINGTHE MITIGATION STANDARDS PER THE MERIDIAN CITY CODE AS PER SECTION 11-3B-10.4.5.SEE TREE MITIGATION NOTES FOR ADDITIONAL INFORMATION.TREE MITIGATION NOTES:1.THE EXISTING TREES TO BE SAVED ARE AS FOLLOWS FROM THE INTERIOR OF THE SITE (ASNOTED ON PLAN):(13) 12" CALIPER DBH AUSTRIAN PINES - (1) TO BE REMOVED AND REPLACED WITH A REQUIRED PARKING LOT TREES (TERMINAL ISLAND)(4) 6" CAL. FLOWERING PEARS ( REPLACE (2) THAT ARE DEAD AS NOTED(5) 10" CAL. FLOWERING PLUMS2.ALONG LOCUST GROVE THERE ARE (5) SUNBURST HONEYLOCUSTS - (1) IS A STUMP, (3) AREDEAD AND (1) IS UNHEALTHY / DYING - ALL FIVE (5) WILL BE REPLACED WITH JAPANESEZELKOVAS AS SHOWN ON PLAN.3.NO TREE MITIGATION NEEDED ON SITE.151111111777332244445555666666666661567778101111121212131313L1.0SHRUB PLANTING2NOT TO SCALE1.SHRUB SHALL BEAR SAME RELATIONSHIP TO GRADE AS IT DID IN NURSERY.2.WATER SHRUB TWICE WITHIN FIRST 24 HOURS.3.THIN BRANCHES AND FOLIAGE BY 13.4.DO NOT CUT LEADERS TO RETAIN NATURAL SHRUB SHAPE.5.FOR CONTAINER GROWN PLANTS THAT ARE ROOTBOUND, SPLIT THE ROOTBALL WITH 3 EQUAL SPACEDVERTICAL CUTS.NOTES:REMOVE ANY PLASTIC, BURLAP, NAILS, OR OTHERMATERIALS FROM THE ROOTBALL WHICH MAY LIMITROOT GROWTHCONSTRUCT 2" EARTH BERM TO FORM A WATERRETENTION BASIN, FILL BERM WITH MULCH, ASSPECIFIEDMULCH, PER PLANS, 3" DEPTH OVER ENTIRE BED. DONOT COVER CROWNS OF PLANTSPROVIDE COMMERCIAL FERTILIZER TABLETS ANDBIOSTIMULANT, AS SPECIFIED, FOR EACH SHRUBBACKFILL WITH APPROVED TOPSOIL AND SOILAMENDMENTS, AS SPECIFIED. BACKFILL IN 6" LIFTS,WATER EACH LAYER, DO NOT TAMP OR OVERCOMPACT.CONSTRUCT 6" MOUND OF TOPSOILGROUNDCOVER PLANTING4NOT TO SCALESECTIONPLAN VIEW1.ALL GROUNDCOVER PLANTS TO BE PLANTED ON CENTER AND IN A TRIANGULAR PATTERN.2.APPLY SPECIFIED PRE-EMERGENT PER MANUFACTURER'S RECOMMENDATIONS TO ALL GROUNDCOVERBEDS.NOTES:FINISH GRADE PER PLANSGROUNDCOVER PLANTING PER PLANTING PLANMULCH, PER PLANS, 3" DEPTH OVER ENTIRE BED.DO NOT COVER CROWNS OF PLANTSTILL SOIL TO A DEPTH OF 12", BACKFILL WITHAPPROVED TOPSOIL AND SOIL AMENDMENTS, ASSPECIFIED.SUBGRADEA = LENGTH, AS SPECIFIED OR PER PLANT SCHEDULEB = 85% OF 'A'DECIDUOUS TREE PLANTING3NOT TO SCALESOIL LINEROOT FLARE TO BE AT SOIL LINENOTES:1.REMOVE BURLAP, TWINE, AND WIRE BASKET FROM TOP 23 OF ROOTBALL. REMOVE ALL NAILS, TIES, AND PLASTIC FROMROOTBALL. IF SYNTHETIC BURLAP IS UTILIZED TO WRAP THE ROOTBALL, IT SHALL BE COMPLETELY REMOVED. ONLYBIODEGRADABLE BURLAP SHALL BE LEFT ON THE BOTTOM OF THE ROOTBALL.2.THE STAKING OF TREES IS TO BE THE CONTRACTOR'S OPTION; HOWEVER, THE CONTRACTOR IS RESPONSIBLE TO ENSURETHAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAIN STRAIGHT FOR LENGTH OF WARRANTY PERIOD OR 1 YEARAFTER SUBSTANTIAL COMPLETION WHICHEVER IS GREATER. ALL STAKING SHALL BE REMOVED AT THE END OF THEWARRANTY PERIOD.3.IN THE EVENT OF A QUESTION OR LACK OF CLARITY ON THE DRAWINGS, THE CONTRACTOR IS TO NOTIFY THE LANDSCAPEARCHITECT BEFORE PROCEEDING.4.LANDSCAPE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT AND OWNER PRIOR TO INSTALLATION OF PLANTMATERIAL.5.WRAP RUBBER CINCH TIES AROUND THE TREE TRUNKS AND STAKES USING EITHER THE STANDARD OR FIGURE EIGHT TYINGMETHOD. SECURE THE TIES TO THE STAKES WITH GALVANIZED NAILS TO PREVENT SLIPPAGE.6.WATER TREE TWICE WITHIN THE FIRST 24 HOURS.7.IN THE EVENT HARDPAN SOILS PREVENT TREE PLANTING AS DETAILED, NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY.8.FOR TREES LOCATED WITHIN ROADSIDE PLANTERS LESS THAN 8'-0" IN WIDTH, PROVIDE TREE ROOT BARRIER (DEEPROOT#24-2 OR APPROVED EQUAL). LOCATE ROOT BARRIER AT BACK OF CURB AND EDGE OF SIDEWALK. ALL TREE INSTALLATIONSSHALL CONFORM TO ALL AGENCY APPROVAL REQUIREMENTS, CONTRACTOR SHALL VERIFY PRIOR TO ANY INSTALLATIONS.REMOVE DEAD/DAMAGED BRANCHES ANDPRUNE TO INTERNATIONAL SOCIETY OFARBORICULTURE STANDARDS; IMPROPERLYPRUNED TREES (AS DETERMINED BY THELANDSCAPE ARCHITECT) SHALL BE REMOVEDAND REPLACED. DO NOT REMOVE MAINLEADER!!RUBBER CINCH TIE2"x 2" WOOD STAKE (LENGTH ASREQUIRED)-DO NOT PENETRATE ROOTBALL.SEE NOTE 1. SET STAKES PARALLEL TOPREVAILING WIND.REMOVE TREE WRAP TRUNK PROTECTION,AFTER INSTALLATIONCONSTRUCT 2" EARTH BERM AT EDGE OFROOTBALL, FILL TREE RING W/ MULCH, ASSPECIFIED.3" THICK MULCH LAYER, KEEP MULCH 3" AWAYFROM TRUNK.FINISH GRADEPREVAILING WIND DIRECTIONCOMMERCIAL SLOW RELEASE FERTILIZERTABLETSSIDES OF HOLE ROUGH & UNEVENBACKFILL WITH APPROVED TOPSOIL ANDSOIL AMENDMENTS AS SPECIFIED.BACKFILL IN 6" LIFTS, WATER EACH LAYER,TAMP LIGHTLY AS REQUIRED, BACKFILLSOIL EVEN W/ TOP OF ROOTBALL,DO NOT OVER COMPACT!!SET ROOTBALL ON NATIVE, UNDISTURBEDSOILPLANTER BED CUT EDGE(TYPICAL AT TREES IN TURF AREAS)1NOT TO SCALEAPPROVED TOPSOIL AND SOILAMENDMENTS AS SPECIFIED3" DEPTH OF MULCH AT PLANTERBEDSFINISH GRADE,PER PLANS414