Loading...
Compass East C-103I ' E ALL CONSTRUCTION IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO THE CURRENT EDITION OF THE ISPWC AND THE ACHD SUPPLEMENTAL SPECIFICATIONS. SPECIFY THAT NO EXCEPTIONS TO DISTRICT POLICY, STANDARDS AND THE ISPWC WILL BE ALLOWED UNLESS SPECIFICALLY AND PREVIOUSLY APPROVED IN WRITING BY THE DISTRICT. I X EXISTING 4" PRESSURIZED IRRIGATION LINE .3e • R48' I a � W I �§ CO. /r_�^. • X W c� N a X • w 6 ' 0 � I I a � • X 0 w W xEI PROPOSED 8" OFFSITE PUBLIC WATER MAIN EXTENSION (SEE W AVIATOR ST PLANS FOR PROPOSED IMPROVEMENTS) PROPOSED OFFSITE STORM WATER BASIN f• .--�: X X X X . . X . :: . . . . • . . • . . . . . . . common. ..�• � • • tetA- X X X X X X X X X X X X X X—M X X T EXISTING IRRIGATION CONTROL BOX 8 SPACES r' 8 SPACES ---J II X IW6 II 1"ELECTRIC SLEEVE (TYP) M II _—_— 8SPACES 19.5' 25' 19' 19' 2514 Cn I I . z I I Of I M 11 SPACES o I I I Cn I I -- • I I z I 0 ■ - o 74'I o II � I 25' INSTALL HOSE BIB • I I N II 9' 8' 8' 9' RELOCATE II TYP) -EXISTING w —�—I— FIRE HYDRANT 7 SPACES II L 8 SPACES CONNECT TO EXISTING IRRIGATION PRESSURE LINE LH x 2Id 2il lid bl lid al wgy 12" INV: 2545.79 a 1. a ET\ Sol °. EXISTING DRAINAGE SWALE EXISTING 3" �< °. PROPOSED 3" PVC C900 PRESSURIZED ` ; a PRESSURIZED IRRIGATION LINE IRRIGATION LINE °.. Alk EXISTING SCHOOL 7 SPACES X PROPOSED 8" ONSITE WATER LINE (SEE SHEET C-201) PLAYGROUND CONTRACTOR/INSTALLER TO CONNECT PLAY AREA DRAINAGE SYSTEM TO EXISTING SWALE X X l 8' -0--- r 12" I NV: 2545.92 •X • • STM • • • • • \\ �< \`\1 • • • • • • • • • • • • • • • 4 • • • i • • Sol J 1 '1 I I I I I I \`I J GENERAL NOTES: REFER TO ELECTRICAL PLANS FOR PROPOSED SITE LIGHTING. REFER TO LANDSCAPE PLAN FOR RESTORATION OF ALL NON PAVED SURFACES. CONTRACTOR IS RESPONSIBLE TO OBTAIN ALL SITE RELATED PERMITS NOT BEING OBTAINED BY THE OWNER. CONTRACTOR IS REQUIRED TO COMPLETE THE APPLICATION, AND SUBMIT NECESSARY DRAWINGS, FEES, ETC. TO THE APPROPRIATE JURISDICTION. CONTRACTOR SHALL PAY ALL FEES RELATED TO PERMIT(S) AND SECURE PERMIT(S) IN HIS NAME. CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL SITE UTILITY CONNECTIONS AND INSPECTIONS WITH THE PROPER JURISDICTION AND PAY ALL ASSOCIATED FEES. THE CONTRACTOR SHALL FIELD VERIFY LOCATION AND ELEVATION OF EXISTING WATER, SANITARY SEWER, AND STORM SEWER CROSSINGS AND CONNECTION POINTS PRIOR TO CONSTRUCTION. CONTACT ENGINEER WITH ANY DISCREPANCIES. REFERENCE SOILS REPORT FOR BORING LOGS AND PREPARATION AND CONSTRUCTION PROCEDURES FOR SUBBASE AND DESIGN SECTION OF ALL PAVED AREAS. ALL ITD REFERENCES ARE TO THE 2020 EDITION. SEE W. AVIATOR STREET IMPROVEMENT PLANS FOR OFFSITE IMPROVEMENTS. ALL DIMENSIONS SHOWN TO CONCRETE CURB AND GUTTER ARE TO BACK OF CURB UNLESS OTHERWISE NOTED. ALL PAVEMENT MARKINGS SHALL BE 4" WIDE. STANDARD PARKING SPACES SHALL BE MARKED IN WHITE AND BARRIER FREE SPACES IN BLUE. EACH BARRIER FREE SPACE SHALL BE PROVIDED WITH A PAINTED PAVEMENT SYMBOL, A PRECAST CONCRETE BUMPER BLOCK, AND A SIGN PER THE MANUAL OF UNIFORM TRAFFIC CONTROLS. GENERAL STORM SEWER NOTES: ALL STORM SEWER PIPE SHALL BE PE. MATERIALS, INSTALLATION, AND TESTING OF THE STORM SEWER SYSTEM SHALL CONFORM TO ISPWC STANDARDS. ALL STORM WATER TO BE RETAINED ONSITE. ALL CONSTRUCTION IN THE PUBLIC RIGHT-OF-WAY SHALL CONFORM TO THE CURRENT EDITION OF THE ISPWC AND THE ACHD SUPPLEMENTAL SPECIFICATIONS. SPECIFY THAT NO EXCEPTIONS TO DISTRICT POLICY, STANDARDS AND THE ISPWC WILL BE ALLOWED UNLESS SPECIFICALLY AND PREVIOUSLY APPROVED IN WRITING BY THE DISTRICT. EXISTING LEGEND ® CONTROL POINT PROPERTY IRON ® NAIL IN WASHER MONUMENT CAP ® T-POST MONUMENT ALUMINUMBRASS AP MONUMENT MONUMENT CONCRETE BITUMINOUS o RIP RAP CURB & GUTTER LANDSCAPE CURB — — CENTER LINE PROPERTY LINE DITCH POND / EDGE OF WATER X FENCE EX IR GR EX IR GR IRRIGATION LINE - GRAVITY EX IR PR EX IR PR IRRIGATION PIPE - PRESSURIZED WTR WATER MAIN SAN SANITARY SEWER STM STORM SEWER UG-E UNDERGROUND ELECTRIC PROPOSED LEGEND T SIGN + LANDING AREA D DETECTABLE WARNING (SHEET C-501/DETAIL #9) o BUMPER BLOCK FLARED END SECTION HYDRANT (SHEET C-501/DETAIL #7) (SHEET C-501/DETAIL #5) W (SHEET C-502/SD-W8) _ SPILLWAY WATER VALVE J-1 TEE — (SHEET C-501/DETAIL #4) ® (SHEET C-502/SD-W11) STREET LIGHT CONCRETE SIDEWALK (SHEET C-501/DETAIL#1) STANDARD DUTY BITUMINOUS (SHEET C-501/DETAIL#2) RIP RAP STANDARD CURB & GUTTER, TYPE 2 (SHEET C-502 / SD-615-1) SINGLE CURB, TYPE 2 (SHEET C-502 / SD-615-1) — — CENTER LINE • • POND/BASIN . . . . . DITCH —— WATER MAIN IR GR IR GR IRRIGATION PIPE - GRAVITY IR PR IR PR IRRIGATION PIPE - PRESSURE X FENCE 50 S Cole Rd Boise, ID DIG Lu ne--im- 800 342- 58509 Cal! Before'You D T 208-342-1585 NOTE: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES, CONDUITS OR STRUCTURES SHOWN ON THESE PLANS WAS OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS AND STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR SHALL POTHOLE ALL EXISTING UTILITIES TO VERIFY THE LOCATION AND ANY DISCREPANCY BETWEEN THE PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER. Li PARADIGM DESIGN ARCHITECTS I ENGINEERS HENRICKSON 4650 E Cotton Center Blvd, Suite 110 ARCHITECTURE + PLANNING Phoenix, AZ 85040 100 Grandville, Suite 030 (602) 374-4066 Grand Rapids, MI 49503 616.458.5554 Grand Rapids I Phoenix I Traverse City www.paradigmae.com JOB #: 2001004PH FIRM #: 3856 (EXP. 01/31/2021) WILLIS M. HADLOCK JP,., P.E. ID - REGISTRATION #1 5063 EXP. DATE 0 1 /3 1/2 0 2 1 0 30' 60' SCALE: 1 "=30' 0 0 Qq CV Cn co CD i 0- M 0 Cn -0 Cn "-0 ei M L n Q '44W C L fm fn o� M � o � Cn H Z C� G W Oo W Z Wo ~ w Zo Oo J W� U Qc) J V♦ Q W 0 J O 0 C/) It w M� LL 2 U J Z) XCL CZC-BID SET 07.29.20 L J• C� • I` • DRAWN BY: JL CHECKED: DF LAYOUT & UTILITY PLAN PROJECT No. • 2001004PH Cml 03