Loading...
G101 - CODE EGRESS LIFE SAFETYCR102 2629.00 58I-12484 105 2626.45 58I-NC 106 2627.95 58I-12484 IVIV IVIV WW 989 SF 20 42 AREA OF ROOM SF PER OCCUPANT PER IBC TABLE 1004.1.2 NUMBER OF OCCUPANTS IN ROOM ROOM NAME CLASSROOM NUMBER OF OCCUPANTS THROUGH DOOR OPENING INDICATES PATH OF EGRESS AND DIRECTION OF TRAVEL FE DF FDC 270 OCC EXIT 0.15 CF 40.5" R 69" P DRINKING FOUNTAIN FIRE EXTINGUISHER - THE MAXIMUM TRAVEL DISTANCE TO REACH AN EXTINGUISHER FROM ANY POINT IN THE BUILDING SHALL NOT EXCEED 75 FEET - COORDINATE FINAL LOCATION WITH FIRE MARSHAL FIRE DEPARTMENT CONNECTION MAXIMUM OCCUPANT LOAD THRU EXIT MINIMUM REQUIRED EXIT WIDTH EXIT WIDTH PROVIDED; DOORS MEASURED BETWEEN DOOR FACE AND STOP CAPACITY FACTOR (STAIRS PER 1005.3.1; OTHER PER 1005.3.2 EXCEPTION 2012 IBC) SYMBOLS LEGEND # ADA UNIT LOCATION TO MEET IBC SECTION 1108.3; SEE DETAIL 3/G101 FOR ADA COMPLIANT DOOR HANDLE DETAIL AND 15/A502 FOR ADA THRESHOLD DETAIL 1A EGRESS ACCESS PATH 2A A COMMON PATH OF TRAVEL PATH ID (SEE EXIT ACCESS DISTANCE SCHEDULE) SUB-PATH BUILDING 9 4,522.41 S.F. BUILDING 10 13,642.31 S.F. BUILDING 11 5931.16 S.F. T R A V E L DIS T A NCE 7 5' - 0 "TRAVEL DISTANCE75' - 0"T R AVE L DI S T ANCE 7 5 ' - 0 " TRAVEL DISTANCE 75' - 0" TRAVEL DISTANCE 75' - 0" 1 1 1 TRAVEL DISTANCE 75' - 0" 1 1 1 30' - 3 31/32"29' - 9" 39' - 9" 40' - 3 31/32"29' - 4"24' - 4"2 Unit Size 5x10 5x12.5 10x10 10x12.5 10x15 10x25 10x30 12x15 12x20 FIRE AREA 1 6721 S.F. FIRE AREA 2 6634 S.F. 1' - 3 1/2" 3 FIRE LANE FIRE LANE FIRE LANE FIRE LANESEE ICC/ANSI GUIDELINES FOR MFD HT.WALL AS SCHED. SEE WALL TYPES. SURFACE FIRE EXTINGUISHER CABINET HAND HELD FIRE EXTINGUISHER ROUGH OPENING REQ.SEE MANUFACTURE FORREQ. ROUGH OPENING SEE MANUF. FOR PROVIDE FURRING/ BLOCKING AS REQ. REQ. ROUGH OPENING SEE MANUF. FOROVERHEAD COILING TYP.1' - 4"AS SCHEDULEDPLATE OC-2 OVERHEAD COILING ADA UNIT - TYPICAL AS SHEDULEDOC-A 3' - 4"9 1/2"1' - 3"STRAP (EXTERIOR)HANDLE (EXTERIOR) WITH ROPE (INTERIOR); ROPE ADJUSTED IN FIELD TO COMPLY WITH ADA REACH REQUIREMENTS (WHEN OPEN) DUST GUARD BOTH SIDES, SEE DETAIL DUST GUARD BOTH SIDES, SEE DETAIL SITE KEYPLAN - BLANK REGION REPRESENTS NEW CONSTRUCTION PHASE 2. - SHADED REGION REPRESENTS EXISTING CONSTRUCTION PHASE 1. 1 1 1 1 111222 W. BALDCYPRESS WAY N. RECORDS AVENUEBUILDING 12BUILDING 11BUILDING 10BUILDING 9 BUILDING 7BUILDING 6BUILDING 5BUILDING 4BUILDING 8 BUILDING 3BUILDING 1BUILDING 230' - 3"29' - 5"FIRE LANEFIRE LANEFIRE LANEFIRE LANEFIRE LANE FIRE LANE FIRE LANE20' - 0" PHASE 1 FIRE HYDRANT369' - 3" Salt Lake City 52 Exchange Place Salt Lake City, UT 84111 801.531.1144 Boise 800 W MAIN STREET SUITE 940 BOISE, ID 83702 208.424.7675 AR-985479P H NO L N D W IESOJW A NGERICE N S D RC H I E LA TECTST A TE OF I D A H ONOT FOR CONSTRUCTIONsheet number:sheet title:stamp: The information and content represented herein is considered by law the architect's instruments of service and are the property of Babcock Design. They are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors, and office personnel only in accordance with this notice. They are intended for use only for the project specified and are to be used for no other purpose or project including additions to or modification of the completed project. No part thereof may be copied, reproduced, photographed, modified, published, uploaded, transmitted, disclosed, sold, distributed to others in any way including in digital form, or otherwise used without the prior written consent of Babcock Design. revisions: date: COPYRIGHT © 2019 BABCOCK DESIGN original drawing is 30" x 42"for:x approval stamp: sheet information: project information: babcockdesign.com project number: project status: current as of: stamp: 7/31/2020 10:56:07 AM USTICK SELF-STORAGE PHASE IICODE - EGRESS LIFE SAFETY G1011523 E. SEASIDE CT.BOISE, ID 83706PERMIT-BID SET 05.28.20 19531 ELEVATE INVESTMENTS, LLCNOTE: THESE NOTES APPLY TO THIS SHEET ONLY. SHEET NOTES 1 WALL MOUNT FIRE EXTINGUISHER CABINET (NON-CORROSIVE MATERIAL). COORDINATE LOCATIONS WITH NOKE DOOR ACCESS SYSTEM VENDOR. 2 2HR FIRE RATED WALL PER PLAN. PER IBC 705.8.1, EXCEPTION 2 EXTERIOR BEARING AND NON-BEARING WALLS THAT ARE NOT REQURIED TO BE FIRE-RESISTANCE RATED ARE PERMITTED TO HAVE UNLIMITED UNPROTECTED OPENINGS. 3 PROPERTY LINE CODE REVIEW - GENERAL NOTES 1. DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS REQUIRED & NOT FOUND, NOTIFY ARCHITECT IMMEDIATELY FOR CLARIFICATION. 2. SEE SHEET G001 FOR GENERAL CODE AND PROJECT SPECIFIC CODE INFORMATION. 3. SEE SHEET G002 FOR GENERAL NOTES 4. ALL STEEL BEAMS TO HAVE 2-HR SPRAY APPLIED FIRE PROOFING AND COLUMNS TO HAVE 3-HR SPRAY APPLIED FIRE PROOFING, TYPICAL ALL FLOORS, UNLESS NOTED OTHERWISE. 5. UNDERSIDE OF ROOF DECKS TO HAVE 1-HR SPRAY APPLIED FIRE PROOFING, UNLESS NOTED OTHERWISE. 6. CONTRACTOR TO COORDINATE ALL FLOOR PENETRATIONS WITH ALL TRADES. ALL PENETRATIONS ARE TO BE 2-HOUR FIRE STOPPED. 7. HIGHER RATED FIRE WALLS TAKE PRECEDENCE OVER LOWER RATED WALLS AND ARE TO CONTINUE THROUGH ALL SUCH INTERSECTIONS. 8. ALL BUILDINGS SHOWN HAVE ARE DIRECTLY ACCESSIBLE FROM THE OUTSIDE. 9. SEE A100 SHEETS FOR WALL TYPE DESIGNATIONS. 10. SEE A450 SHEETS FOR SHAFT SECTIONS. 11. SEE A500 SHEETS FOR FIRE PROOFING DETAILS. 12. SEE A600 SHEETS FOR WALL ASSEMBLIES, TOP OF WALL DETAILS, UL LISTINGS, ETC. FIRE RATING LEGEND 2 HR FIRE BARRIER NON RATED 1/16" = 1'-0"1 CODE EGRESS SAFETY BUILDING SF TOTAL ROOM OCCUPANCY AREA BUILDING 9 Accessory Storage Areas, Mechanical Equipment Room 4643 SF 4643 SF BUILDING 10 Accessory Storage Areas, Mechanical Equipment Room 12430 SF 12430 SF BUILDING 11 Accessory Storage Areas, Mechanical Equipment Room 5392 SF 5392 SF 1 1/2" = 1'-0"2 F.E. CABINET SURFACE MOUNTED FP-M-08NORTH 1/4" = 1'-0"3 SPECIALTY DOOR TYPES OP-BDG-07num.description date 1" = 60'-0"4 PHASE I & II SITE PLAN NORTH