Loading...
REVISED Site Plan (Phase 1)METER PACKMETER PACKSCALE: 1" = 20'-0" P R O P O S E D S I T E P L A N 1.962 ACRES LOT #8 S89°35'15"E 300.00' S89°35'15"E 300.00'N00° 24'45"E285.00N00° 24'45"E285.00FIRE TRUCK TURN RADIUS BOTH ENDS OF THE BUILDING E. JEWELL STREET PRESSURIZED IRRIGATION EASEMENT FIRE TRUCK TURN RADIUS BOTH ENDS OF THE BUILDING 30'-0"30'-0" ACCESS GATEACCESS GATE DOG PARK RUN DOG PARK RUN 49'-9"49'-9"47'-0"20'-0"(LANDSCAPEEASEMENT)35'-0"(STREETSETBACK)10'-0"(IRRIGATIONEASEMENT)2 3 4 1 1 11 S I T E R E C A P TOTAL PROJECT SITE: 85,378 SQ. FT. (1.960 ACRES) AREA CALCULATIONS PROPOSED BUILDING #1 2,250 SQ. FT. PROPOSED BUILDING #2 2,571 SQ. FT. PROPOSED BUILDING #3 2,250 SQ. FT. TOTAL BUILDING FOOTPRINT AREA 7,066 SQ. FT. PARKING REQUIRED:ONE SPACE PER 500 SF OF OFFICE 1,000 SF (OFFICE) / 500 = 2 SPACES HC ACCESSIBLE 1 SPACES PROVIDED:HC ACCESSIBLE 1 SPACES STANDARD 4 SPACES TOTAL 5 SPACES BIKE PARKING-(TABLE 8-4D-3) NO PROPOSED BIKE PARKING, PER SELF STORAGE CITY ZONING- I-L SETBACKS: FRONT- 35'-0'' REAR- 0'-0'' SIDES- 0'-0'' G E N E R A L N O T E S A.ALL BIKE PARKING IS PROPOSED WITHIN THE PROPOSED BUILDINGS. B.SEE LANDSCAPE PLAN L-1.0 FOR UNDERGROUND IRRIGATION. K E Y N O T E S ELECTRICAL METER. GAS METER. PROPOSED TRASH ENCLOSURE, SEE DETAILS ON SHEET A-1.1. DUMP STATION NEW 5' WIDE SIDEWALK. ADA PARKING STALL WITH AISLE ASPHALT PAVING LANDSCAPING AREA, SEE LANDSCAPE DRAWINGS. PROPOSED FIRE HYDRANT LOCATION. 1 2 3 4 5 6 7 8 9 50'-0"PROPOSED BUILDING #2 PROPOSED BUILDING #3 PROPOSED BUILDING #1 FUTURE BUILDING AREA FUTURE BUILDING AREA FUTURE BUILDING AREA COMMON ACCESS DRIVE 25'-0"45'-0"10'-0"20'-6"19'-6"50'-3"100'-0"49'-9"19'-6"25'-8"555 6 77 77 7 888 8 2,250 S.F.2,250 S.F. 2,566 S.F. A P P L I C A N T I N F O. DEVELOPER: FRED TUCKER ADDRESS: P.O. BOX 70, PARMA, ID 83642 PHONE: 208-850-6734 20'-6"10'-0" 9 D C B A 1 2 3 4 5 6 1 2 3 4 5 6 D C B A A-1.0 SITE PLANDESCRIPTION- COMMENTSDATEDELTAJEWEL ST. STORAGEHATCH DESIGNARCHITECTURE6126 W. STATE ST.BOISE, IDAHO 83703OFFICE: (208) 475-3204FAX: (208) 475-3205THIS PLAN AND/OR DESIGN ARE NOT TO BE CHANGED ORCOPIED IN ANY FORM, NOR ARE THE DOCUMENTS TO BEASSIGNED TO A THIRD PARTY WITHOUT WRITTEN CONSENTAND PROPER COMPENSATION TO HATCH DESIGNARCHITECTURE.THE USE OF THE PLANS SHALL BE RESTRICTED TO THEORIGINAL SITE FOR WHICH THEY WERE PREPARED.DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS,INCLUDING THOSE IN ELECTRONIC FORM, PREPARED BYTHE DESIGNER AND THE DESIGNER'S CONSULTANTS AREINSTRUMENTS OF SERVICE FOR USE SOLELY WITH RESPECTTO THIS PROJECT. THE DESIGNER AND THE DESIGNER'SCONSULTANTS SHALL BE DEEMED THE AUTHORS ANDOWNERS OF THEIR RESPECTIVE INSTRUMENTS OF SERVICEAND SHALL RETAIN ALL COMMON LAW, STATUTORY ANDOTHER RESERVED RIGHTS, INCLUDING COPYRIGHTS.DATE: JOB NUMBER:19172 MAY 2020 DRAWN BY: CHECKED BY:JLH NJM, TLMCOPYRIGHT 2020HATCH DESIGNARCHITECTURESHEET SHEET NUMBER SHEET TITLENEW STORAGE FACILITY:2590 E. JEWEL ST., MERIDIAN, ID 83642