Loading...
ACHD TransmittalPlanning Division DEVELOPMENT REVIEW APPLICATION Community Development  Planning Division  33 E. Broadway Avenue, Ste. 102 Meridian, Idaho 83642 Phone: 208-884-5533 Fax: 208-888-6854 www.meridiancity.org/planning -1 Rev:(2/2/20182/7/2018) STAFF USE ONLY: Project name: File number(s): Assigned Planner: Related files: Type of Review Requested (check all that apply)  Accessory Use (check only 1)  Daycare  Home Occupation  Home Occupation/Instruction for 7 or more  Administrative Design Review  Alternative Compliance  Annexation and Zoning  Certificate of Zoning Compliance  City Council Review  Comprehensive Plan Map Amendment  Comprehensive Plan Text Amendment  Conditional Use Permit  Conditional Use Modification (check only 1)  Director  Commission  Development Agreement Modification  Final Plat  Final Plat Modification  Landscape Plan Modification  Preliminary Plat  Private Street  Property Boundary Adjustment  Rezone  Short Plat  Time Extension (check only 1)  Director  Commission  UDC Text Amendment  Vacation (check only 1)  Director  Commission  Variance  Other Applicant Information Applicant name: Phone: Applicant address: Email: City: State: Zip: Phone: Owner address: Email: City: State: Zip: Agent/Contact name (e.g., architect, engineer, developer, representative): Firm name: Phone: Agent address: Email: City: State: Zip: Primary contact is:  Applicant  Owner  Agent/Contact Subject Property Information Location/street address:2562 W EXCURSION LN MERIDIAN , ID 83642 Township, range, section: 3N 1W 14 Assessor’s parcel number(s): ___________ ______________ Total acreage: Zoning district: x Horrocks Engineers 208-895-2520 2775 W. Navigator Dr., Suite 210 scottd@horrocks.com / robs@horrocks.com Meridian ID 83642 Engineer ConsultantApplicant’s interest in property:  Own  Rent  Optioned  Other Owner name: BVASB TEN MILE PHASE 2 BUILDING LLC Meridian ID 83642 Developer BVA Development LLC 2775 W. Navigator Dr., Suite 220 Meridian ID 83642 roberta@bvadev.com / tonn@bvadev.com roberta@bvadev.com robs@horrock.com scottd@horrocks.com 208-287-0518 2929 W. Navigator Way, Suite 400 jwardle@brightoncorp.com 208-616-1050 S1214314956 C-G4.593 X kindi.moosman@horrocks.com / robs@horrocks.com roberta@bvadev.com robs@horrocks.com kindi.moosman@horrocks.com x TM Crossing Building No. 8 A-2020-0116 Stacy Hersh Community Development  Planning Division  33 E. Broadway Avenue, Ste. 102 Meridian, Idaho 83642 Phone: 208-884-5533 Fax: 208-888-6854 www.meridiancity.org/planning -2- Rev:(2/7/2018) Project/subdivision name: General description of proposed project/request: Proposed zoning district(s): Acres of each zone proposed: Type of use proposed (check all that apply):  Residential  Office  Commercial  Employment  Industrial  Other Who will own & maintain the pressurized irrigation system in this development? Which irrigation district does this property lie within? Primary irrigation source: Secondary: Square footage of landscaped areas to be irrigated (if primary or secondary point of connection is City water): Residential Project Summary (if applicable) Number of residential units: Number of building lots: Number of common lots: Number of other lots: Proposed number of dwelling units (for multi-family developments only): 1 bedroom: 2–3 bedrooms: 4 or more bedrooms: Minimum square footage of structure (excl. garage): Maximum building height: Minimum property size (s.f): Average property size (s.f.): Gross density (Per UDC 11-1A-1): Net density (Per UDC 11-1A-1): Acreage of qualified open space: __________________ Percentage of qualified open space: __________________ Type and calculations of qualified open space provided in acres (Per UDC 11-3G-3B): Amenities provided with this development (if applicable): Type of dwelling(s) proposed:  Single-family Detached  Single-family Attached  Townhouse  Duplex  Multi-family  Vertically Integrated  Other ____________________________________ Non-residential Project Summary (if applicable) Number of building lots: Common lots: Other lots: Gross floor area proposed: Existing (if applicable): Hours of operation (days and hours): Building height: Total number of parking spaces provided: Number of compact spaces provided: Authorization Print applicant name: Applicant signature: Date: N/A 6:00 AM to 11:00 PM None Scott Duffin C-G 1 0 Owner , PE on behalf of the developer and property owner 05/14/2020 s.f.NA (already zoned C-G) (already zoned C-G) 76' 4" 124,070 Kindi Moosman, Planner on behalf of the developer and property owner Ten Mile Crossing CZC, Design Review, and Alternative Compliance for Ten Mile Crossing Office Building No. 7. x Nampa Meridian Irrigation Company Ridenbaugh Canal Lateral Well 9,380 SF 373 cushingterrell.com March 10, 2020 Eagle View Landing Office Building 7 Design Review Narrative The proposed “Office Building 7” at Eagle View Landing is 5 stories, with just under 25,000 square feet per floor. The initial shell construction will contain a central core with restrooms, janitor’s closet, two elevators, and an electrical room. The site is located on the northeast quadrant of Ten Mile and I-84, in Ten Mile Crossing. This development’s location serves as a gateway to Meridian and the growing Treasure Valley. The development is being planned as such, with a mix of commercial offices and healthcare, among other future uses. Office Building 7 is designed to be integral and cohesive to this development. There is consistency in the materiality and architecture, while varying the appearance of individual buildings. Office Building 7 will be of similar scale to adjacent planned office buildings. The Office Building 7 form is similar to proposed adjacent office buildings. It utilizes an efficient rectangular form with exposed stair towers adjacent to main entrances, helping to break up the north and south elevations. High performance glazing maximizes daylight within while taking advantage of 360 degree views. It also creates banding on the outside, accented with surrounding EIFS massing, and a masonry base to ground the building while providing a more durable material adjacent to higher traffic exterior areas. EIFS banding provides façade articulation, includes locations for major tenant signage on the building, and will utilize LED accent strip lighting around the perimeter to subtly highlight architectural elements and add visual interest at night. Vertical shading fins reduce interior solar exposure and add additional depth and visual interest. Primary building entries, with adjacent stair towers as “beacons,” define their locations from a distance. Entries are proportioned for pedestrian scale and comfortable approach for daily users. The stair towers are broken up with vertical windows that allow natural light into the stairwells, promoting occupant use over elevators throughout the day while backlighting from within to define their location at night. Building massing, materiality and proportions work together to create a unified building with a modern, clean aesthetic. ss ss ss ss ss ss ss ss ss ss ss ss ss ss 10'' sd10'' sd10'' sd10'' sd10'' sd10'' sd10'' sd10'' sd10'' sd10'' sd10'' sd10'' sd 10'' sd 8'' w8'' w8'' w8'' wirrirrirrirrirrirrirrirrirrirrirrirrirrirrirrirrirrirrirrirrirrirrirrirr irr irr irr irr irr irr irr irr irr irr irr irr irr irr irr irr irr irr irr irr irrirrirrirrirrirrirrirrirrirrirrirrirrirrirrirrirrirrirrirrirr12'' SD12'' SD SDSDSDSDSDSDSDSDCOCOS RD RD CO SDCO SDE A 8 8 9 9 B C D VESTIBULE 101 101A101B 13 LEASABLE SPACE 112 Elev E2Elev E21 2 3 4 6 7 D C A 5 AA 3.4 4.4 DD 2.8 3.8 B SDLOD LOD LOD LOD LOD LOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD L O D LODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODSS SS SS CO CO PL PLPLPL8.53'17'25'17'7.5'5'220.5'5'7.5'17'25'38'25'14.71'112.5'19'24'5.5'4.43'40.07'90'19.5'24'28.64'81'44'96'17'25'38'25' 5'7'19.34'13.66'5.5'36'25'6'90'7'24'19'28.14'108'20'24'30.1'9.14'13.66'10'15'8'12.23'24.5'4.43'4.43'5.5'5.5'63'7.95'6.05'19.5'24'25'25.52'15.5'6.56'19.5'7'5'78.83'6'25'C1C2C3C4 C8C920'20'24'20'20'26.04'20'20'24.5'17'19'12.27'Curve Table Curve # C1 C2 C3 C4 C8 C9 Length 23.55' 7.85' 7.85' 7.86' 7.85' 7.85' Radius 15.00' 5.00' 5.00' 5.00' 5.00' 5.00' Delta 89°58'12" 90°00'00" 90°00'00" 90°01'46" 90°00'00" 90°00'00" Chord Direction S45°49'20"W N44°11'34"W N45°48'26"E S44°10'41"E N45°48'26"E N44°11'34"W Chord Length 21.21' 7.07' 7.07' 7.07' 7.07' 7.07' O:\!2016\PG-852-1601 Ten Mile Crossing\02 CAD\02 Sheet Files\Building 7\ID-2241-2002_BUILDING 7 CZC.dwg - CZC - 5/20/2020 04:33pm, niko.hardman 1 5 REVISIONSREV #DATEDRAWING INFODATEDESIGNEDDRAWN*SEE GENERAL NOTES SHEETWARNING012IF THIS BAR DOES NOTMEASURE 2" THENDRAWING IS NOT TO SCALEPRELIMINARYNOT FORCONSTRUCTIONwww.horrocks.comPAGE C PROJECTCHECKEDD B A #2 3 4 2162 West Grove Pkwy., Suite 400Pleasant Grove, UT 84062(801) 763-5100ID-2241-2002RSNKH NKH5/18/20SITE PLANMERIDIAN CZCOFFICE BUILDING 7MERIDIAN, ID1 OF 1 1HORRO C K SEN G I N E E R SN 0 30'60' SCALE: 1" = 30' SITE INFORMATION TOTAL LOD AREA: 76,920 SF (1.77 AC) PROPOSED BUILDING ·TOTAL BUILDING FOOTPRINT: 24,990+/- GSF ·TOTAL BUILDING AREA (ALL FLOORS): 124,070+/- GSF ·MAXIMUM BUILDING HEIGHT: 76'-4" ·MAXIMUM ALLOWABLE BUILDING HEIGHT: 65'-0" ZONING REQUIREMENTS ·ZONING: CITY C-G, GENERAL COMMERCIAL ·BUILDING SETBACKS: - FRONT = 0' - REAR = 0' - SIDES = 0' ·LANDSCAPE SETBACKS: - LOCAL = 10' - COLLECTOR = 20' - ARTERIAL = 25' - ENTRYWAY CORRIDOR = 35' - INTERSTATE = 50' PARKING INFORMATION ·PARKING STALLS REQUIRED: 248 ·PARKING STALLS PROVIDED: 373 ·*HANDICAP STALLS REQUIRED: 8 ·**HANDICAP STALLS PROVIDED: 8 ·BICYCLE PARKING STALLS REQUIRED: 15 ·BICYCLE PARKING STALLS PROVIDED: 16 NOTES: * PER ADA REQUIREMENTS ** INCLUDES 2 VAN ACCESSIBLE STALLS NOTES 1.DIMENSIONS ARE TO FRONT FACE OF CURB FOR DRIVE ISLES. 2.RADII ARE 3.5' UNLESS OTHERWISE NOTED. ENGINEER HORROCKS ENGINEERS 2775 W. NAVIGATOR DR. SUITE 210 MERIDIAN, ID 83642 CONTACT: ROB SUNDERLAGE PE PHONE: 208-895-2520 PROPOSED CONCRETE SIDEWALK LEGEND BIKE RACK DETAIL THIS AREA NOT INCLUDED IN THIS PROPOSED SITE CZC BUT IS SHOWN BECAUSE ACCESS AND UTILITY SERVICES TO THE PROPOSED SITE ARE INCLUDED IN THIS AREA. A SEPARATE APPLICATION WILL BE MADE TO THE CITY FOR THE AREA. DEVELOPER BVA DEVELOPMENT, LLC 2775 W. NAVIGATOR DR. SUITE 220 MERIDIAN, ID 83642 PHONE: 208-616-1050 PROPOSED HEAVY DUTY ASPHALT PAVEMENT 2'35"24" NOTES: CONSTRUCT CONCRETE AND BASE THICKNESS TO SAME SPECIFICATIONS AS ADJOINING SIDEWALK GRADING SHALL NOT EXCEED 2% IN ALL DIRECTIONS INVERTED U RACKS MAY BE MOUNTED ON OR EMBEDDED IN CONCRETE FOLLOWING MANUFACTURER'S INSTRUCTIONS RACKS USED SHALL BE SCHEDULE 40 PIPE MADE OF DURABLE METAL WITH WEATHERPROOF COATING AND SHALL BE MANUFACTURED FOR THE INTENDED PURPOSE LIMIT OF DISTURBANCE (LOD)LOD LOD ASPHALT: ASPHALT MIX DESIGN SHALL MEET THE REQUIREMENTS OF ISPWC SECTION 810 CLASS III PLANT MIX. MATERIALS SHALL BE PLACED IN ACCORDANCE WITH ISPWC STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION AGGREGATE BASE: MATERIAL TO COMPLY WITH ISPWC STANDARD FOR CRUSHED AGGREGATE MATERIAL STRUTURAL SUBBASE: GRANULAR STRUCTURAL FILL MATERIAL COMPLYING WITH THE REQUIREMENTS DETAILED IN THE STRUCTURAL FILL SECTION OF THIS REPORT EXCEPY THAT THE MAXIMUM MATERIAL DIAMETER IS NO MORE THAN 2 3 THE COMPONENT THICKNESS. GRADATION AND SUITABILITY REQUIREMENTS SHALL BE PER ISPWC SECTION 801, TABLE 1. - A QUALIFIED GEOTECHNICAL ENGINEER OR ENGINEERING TECHNICIAN IS REQUIRED TO VERIFY SUBGRADE COMPETENCY AT THE TIME OF CONSTRUCTION. ALL EARTHWORK, FLEXIBLE AND RIGID PAVEMENT CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE SITE GEOTECHNICAL REPORT B191814g BY MTI DATED 11/14/19. FLEXIBLE (ASPHALT) PAVEMENT SECTION TABLE ASPHALTIC CONCRETE CRUSHED AGGREGATE BASE STRUCTURAL SUBBASE COMPACTED SUBGRADE 20.0" 4.0" 3.0" SEE PAVEMENT SUBGRADE PREPARATION SECTION HEAVY DUTY SEE PAVEMENT SUBGRADE PREPARATION SECTION 4.0" 16.0" 2.5" LIGHT DUTY PROPOSED TRASH ENCLOSURE PROPOSED BUILDING 7 PROPOSED HEAVY DUTY ASPHALT (TYP.) (DEMO EX LD ASPHALT) EXISTING HEAVY DUTY ASPHALT PROPOSED 6" SANITARY SEWER SERVICE SEWER CONNECTION EXISTING HEAVY DUTY ASPHALT EXISTING LIGHT DUTY ASPHALT EXISTING HEAVY DUTY ASPHALT EXISTING INFILTRATION BED RELOCATE EXISTING STORM DRAIN CATCH BASIN EXISTING STORM DRAIN CATCH BASIN (DEMO) EXISTING INFILTRATION BEDEXISTING LIGHT DUTY ASPHALT EXISTING HEAVY DUTY ASPHALT PROPOSED HEAVY DUTY ASPHALT (TYP.) (DEMO EX LD ASPHALT) EXISTING STORM DRAIN CATCH BASIN (DEMO) RELOCATE EXISTING STORM DRAIN CATCH BASIN PROPOSED STORM DRAIN CATCH BASIN (TYP.) RELOCATE EXISTING STORM DRAIN CATCH BASIN 8" WATER SERVICE STUB FOR FUTURE CONNECTION ADA RAMP (TYP.) ADA RAMP (TYP.) HANDICAP PARKING SPACE HANDICAP PARKING SPACE PROPOSED BICYCLE RACKS EXISTING PROPERTY LINE ADA RAMP (TYP.) EXISTING PARKING STALLS EXISTING CELL TOWER PARCEL 2,400 SF