CC - Engineer Statement i
B & A Engineers , Inc.
Consulting Engineers & Land Surveyors
5505 West Franklin Rd. Boise, ID 83705
Telephone 208.343.3381 Facsimile 208.342.5792
Allmon Subdivision
Street Centerline Elevation
Engineer's Statement
Date: 13 May 2020
Prepared By: J. D. Canning, PE/PLS
Materials Testing and Inspection, Inc. completed a site geotechnical report for the
subject development on 18 November 2019. Based upon the elevation of expected
seasonal high groundwater contained within said report, 1 certify that the elevation of the
street centerlines portrayed on our project construction plans are a minimum of three
feet above said elevation. To confirm this statement, we have used the following data:
• Groundwater Depth Noted in the Report: 20 Feet Below Ground Surface
• Ground Elevation at Observation Point: 2600 Feet
• Groundwater Elevation: 2580 Feet
• Elevation of Lowest Street Centerline: 2597.49 Feet
• Difference in Elevation: *17 Feet