Loading...
FB Clubhouse Photometric Layout Drawn By: Date: Project Name:Ethan Griffiths 4/9/2020 Client: Alloway Electric Fairbourne Clubhouse Rev 1 1.4 1.2 0.4 0.6 1.0 1.2 1.3 1.2 0.5 0.4 0.7 1.2 1.4 1.3 1.0 0.5 0.5 0.8 1.2 1.5 1.5 1.2 0.6 0.5 0.8 1.3 1.6 1.9 1.3 0.7 0.5 0.8 1.2 1.7 1.9 1.3 0.5 0.9 1.3 1.8 1.9 1.2 0.6 0.9 1.4 1.7 2.0 1.2 0.6 1.0 1.4 1.4 1.4 1.1 0.6 0.9 1.4 1.3 1.2 1.3 0.2 0.3 0.6 0.2 0.3 0.6 0.2 0.3 0.5 0.2 0.3 0.5 0.2 0.3 0.4 0.2 0.3 0.4 0.3 0.3 0.4 0.3 0.3 0.4 0.4 0.3 0.5 0.4 0.3 0.6 0.5 0.3 0.7 0.5 0.4 0.9 0.6 0.4 1.0 0.7 0.4 1.1 0.7 0.4 Luminaire Schedule Symbol Qty Label LLF Lum. Watts Lum. Lumens Mounting Height 4 USSL-C01-D-U-T3-BZ 0.900 52 7111 25 Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min Parking Lot Illuminance Fc 1.12 2.0 0.4 2.80 5.00 Roadway Illuminance Fc 0.43 1.1 0.2 2.15 5.50