Loading...
PZ - GWMonitoring.2019.10.08 NATURAL -RESOURCE 454 Consulting, Soil Evaluations & Data Collection HARLEYR.NoE Phone: 208.850.4926 October 8, 2019 Fax: 208.939-8602 Mr Jon Wardle Brighton Corporation 2929 W. Navigator Drive Suite 400 Meridian, ID 83642 RE: Final 2019 season groundwater report—Pinnacle parcel I have completed groundwater monitoring for the 2019 irrigation season on the Pinnacle property located south of Amity and divided by Locust Grove Road. You requested I read 17 piezometers on this large parcel just 3 times during the season. Attached is the data sheet with the readings. Also attached is a map of the site showing GPS locations of all piezometers. Only the pipe at I I-18 had water present at 48 inches below ground level on one reading. This test pit was located in the low corner of a field and two waste water ditches run beside the piezometer. Once water was not present in the ditches at the final reading, groundwater was not present. This indicates that location will also be dry to some depth after development. The pipe at TP 1-18 is located in a drainage area where wastewater accumulates and prevented access to that piezometer. Soils at this point are saturated throughout the summer and they do not represent conditions as they will exist in post-development. I have always contended that groundwater levels over this site are typically well below 15 feet and this 2019 data supports that statement. Monthly readings collected in 2018 which mirror the current year data. I believe the collected data over this 2 year period shows what will be post-development drainage conditions. You should be able to use 15 feet as a conservative value for design purposes at any location. If you have questions please call or send me an e-mail. transmitted via e-mail HARLEY R. NOE Professional Soil Scientist cc w/ attachments via e-mail: Daniel Frisby, Brighton Corporation 5740 N. APPLEBRoox WAY BoisE,InAHo 83713 1PI-is TP218 \TP31a TP518 TPT 18 L TP 18 8 TP12 18 " ) baloo s indicate is 4 F, Tg17 i gery TP15-tH 1l 1 TP16 18 I c Pinnacle 2019 Groundwater Monitoring All readings are depth below ground level in inches Hole Bottom 3/22 7/11 10/2 Number Depth TP1-18 W%01 86+ na na TP2-18 196 196+ 196+ 196+ TP3-18 161 161+ 161+ 161+ TP4-18 173 173+ 173+ 173+ TP5-18 DEST DEST DEST TP6-18 153 153+ 153+ 153+ TP7-18 186 186+ 186+ 186+ TP8-18 204 204+ 204+ 204+ TP9-18 201 201+ 201+ 201+ TP10-18 201 201+ 201+ 201+ TP11-18 57 57+ 46 57+ TP12-18 185+ 185+ 185+ TP13-18 33 33+ DEST DEST TP14-18 162 162+ 162+ 162+ TP15-18 136 136 136+ TP16-18 171 171+ 171+ 171+ TP17-18 184 184+ 184+ 184+ BOTTOM DEPTH value is from top of main pipe to b NOTE: a "+"following the readings indicates pipe wa! 7/11 - Water at 17-18 due to tail water ditches surrounding