Loading...
L2.0 IRRIGATION PLANFUTURE PAD H FUTURE PAD G FUTUREDT 3FUTUREPAD FW W W W W W W W W W W W W W W W W W W W W WWWWW WWWWWWWWP P P FUTURE PAD H FUTURE PAD G FUTUREDT 3FUTUREPAD FW W W W W W W W W W W W W W W W W W W W W WWWWW WWWWWWWWPROPOSED BUILDING E. FAIRVIEW AVE. N . W E B B W A Y D2 D3 D4 D5 R1R2 TS11 R4 TS1 TS2 TS4TS5 TS6 TS7 TS8 TS9 D1 R7 TS10 TS12 TS13 TS14 TS15 TS19 3 L2.5 4 L2.5 5 L2.5 2 L2.5 9 L2.5 10 L2.5 8 L2.5 1 L2.6 7 L2.5 6 L2.5 2 L2.6 3 L2.6 4 L2.6 TS16 1 L2.5 TS17 TS3 TS20 TS21 TS22 TS23 R5 R6 TS18 TS24 D6 ZONE # GPM PSI VALVE SIZE PAD/BLDG ZONE SCHEDULE D 1 D 2 D 3 D 4 D 5 D 6 TS 1 TS 2 TS 3 TS 4 TS 5 TS 6 TS 7 TS 8 TS 9 TS 10 TS 11 TS 12 TS 13 TS 14 TS 15 TS 16 TS 17 TS 18 TS 19 TS 20 TS 21 TS 22 TS 23 TS 24 R1 R2 R3 R4 R5 R6 R7 30 30 30 30 30 30 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 50 50 50 50 50 50 50 1" ICZ-101-LF-R-40 1" ICZ-101-LF-R-40 1" ICZ-101-LF-R-40 1" ICZ-101-LF-R-40 1" ICZ-101-LF-R-40 1" ICZ-101-LF-R-40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 ICV-101G-FS-R-AS40 SYMBOL DESCRIPTION 'HUNTER' PROS-04-PRS30-CV SERIES POP-UP SPRAY SPRINKLERS. NOZZLE AS INDICATED ON PLANS. 'HUNTER' I-20-04-PRB-R SERIES ROTOR SPRINKLERS. NOZZLE AS INDICATED ON PLANS. 'HUNTER' ICV-101G-FS-R-AS40 AND ICZ-101-40 (AT DRIP ZONES) ELECTRIC REMOTE CONTROL VALVE WITH ADJUSTABLE ACCU-SYNC PRESSURE REGULATOR. SEE ZONE SCHEDULE FOR VALVE SIZE. 'HUNTER' REMOTE CONTROL VALVE LABEL (TS = TURF SPRAY, D = DRIP). PVC LATERAL SUPPLY DRIP IRRIGATION 3/4" CLASS 200 SOLVENT WELD PVC IRRIGATION LATERAL 1" CLASS 200 SOLVENT WELD PVC IRRIGATION LATERAL 1-1/4" CLASS 200 SOLVENT WELD PVC IRRIGATION LATERAL 1-1/2" CLASS 200 SOLVENT WELD PVC IRRIGATION LATERAL 1-1/2" SCHEDULE 40 SOLVENT WELD PVC SUB-MAIN LINE. SCHEDULE 40 IRRIGATION SLEEVE, SIZE AS INDICATED ON PLANS. (Provide an additional 2" sleeve at all main line sleeve locations for control wires.) GRAY SCHEDULE 40 PVC FOR ELECTRICAL CONTROL WIRES, SIZE AS INDICATED ON PLANS. COORDINATE WITH ELECTRICAL. 1 1/4" WILKINS GATE VALVE OR APPROVED EQUAL. 1" HUNTER HQ-5LRC QUICK COUPLING VALVE W/ HK-55 KEY, AND HOSE SWIVEL, SEE DETAIL. 'HUNTER' HCC 8 STATION BASE MODEL (HCC-800-PL) WALL MOUNT CONTROLLER WITH ICM-2200 MODULE, SEE DETAIL. MANUAL DRAIN VALVE AS DETAILED. IRRIGATION MATERIAL LEGEND 7.82 11.55 12.44 8.23 5.32 8.28 16.90 15.85 27.21 26.59 30.55 27.94 24.06 16.46 14.28 24.91 26.19 18.66 16.14 10.15 23.04 29.83 22.49 34.04 28.86 33.56 20.54 18.60 24.78 25.68 21.50 10.50 18.00 23.04 24.75 13.50 16.75 D# PAD G PAD H PAD F PAD F PAD G PAD G PAD G PAD G PAD G PAD G PAD G PAD G PAD F PAD F DT 3 DT 3 DT 3 DT 3 PAD F PAD G PAD G PAD H DT 3 DT 3 1.CONNECT NEW 1-1/2" IRRIGATION SUB MAINLINE WITH SADDLE TAP TO EXISTING PRESSURIZED IRRIGATION MAINLINE IN THIS APPROXIMATE LOCATION, SIZE TO MATCH MAINLINE (FIELD VERIFY). REFER TO CIVIL PLANS FOR ADDITIONAL INFORMATION. 2.CONNECT NEW 1-1/2" IRRIGATION SUB MAINLINE WITH SADDLE TAP TO FUTURE PRESSURIZED IRRIGATION MAINLINE IN THIS APPROXIMATE LOCATION, SIZE TO MATCH MAINLINE (FIELD VERIFY). REFER TO CIVIL PLANS FOR ADDITIONAL INFORMATION. 3.2" WIRE SLEEVE. ROUTE TO CONTROLLER LOCATION PER LOCAL CODES AS REQUIRED. 4.WALL MOUNT INDOOR IRRIGATION CONTROLLER IN FIRE RISER ROOM AS SHOWN. CONNECT 120 VOLT AS REQUIRED. ALL ABOVE GRADE WIRES SHALL BE LOCATED IN APPROPRIATELY SIZED CONDUIT (2" MINIMUM). IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WITH CERTIFIED ELECTRICAL CONTRACTOR FOR ALL ELECTRICAL CONNECTIONS. IRRIGATION CONTRACTOR SHALL ENSURE ALL CONTROLLER OPTIONS AND ZONES ARE FULLY OPERATIONAL AFTER TRENCHING HAS FINISHED. CONTROLLER LOCATION TO BE OWNER APPROVED. REVISE LOCATION AS REQUIRED. 5.EXTEND EXTRA WIRES TO THIS POINT. COIL APPROXIMATELY 24" LENGTH OF EXTRA WIRES IN SEPARATE VALVE BOX AT THIS LOCATION. 6.INSTALL 'HUNTER' POLYFLEX RISER AT END OF DRIPZONE LINE TO ENSURE PROPER FUNCTIONALITY. NOZZLE WITH (TS-T-Q). 7.INSTALL MANUAL FLUSH VALVES AT END OF DRIP ZONE LINE FOR MAINTENANCE PURPOSES. 8.IRRIGATION PIPING LAYOUT IS SCHEMATIC. WHERE MAINLINE, LATERAL LINE AND OTHER MATERIALS ARE SHOWN IN ASPHALT OR CONCRETE HARDSCAPE AREAS, IT SHALL BE LOCATED IN ADJACENT LANDSCAPE AREAS. CALLOUT NOTES CALLOUT NUMBERS REFER TO NUMBERED NOTES BELOW # DRIP MATERIAL LEGEND NETAFIM- AREA ONE NETAFIM- AREA TWO NETAFIM- AREA THREE NETAFIM- AREA FOUR NETAFIM- AREA FIVE NETAFIM- AREA SIX 2145 EAST FAIRVIEW AVEPINE 43 - PAD 'E' RETAIL SHOPSTHESE DRAWINGS AND SPECIFICATIONS, AS INSTRUMENTSOF SERVICE, ARE AND SHALL REMAIN THE PROPERTY OFTHE ARCHITECT / ENGINEER WHETHER THE PROJECT FORWHICH THEY ARE MADE IS EXECUTED OR NOT. THESEDRAWINGS AND SPECIFICATIONS SHALL NOT BE USED BYANY PERSON OR ENTITY ON OTHER PROJECTS, FORADDITIONS TO THIS PROJECT, OR COMPLETION OF THISPROJECT-WHEN PHASED-WITHOUT THE WRITTEN CONSENTOF CSHQA OR ITS AFFILIATES. Copyright © 2020MERIDIAN, IDAHO20019.0 05-01-20 ORIGINAL SHEET SIZE 24" x 36"200 BROAD STREETBOISE, IDAHOPHONE: 208-343-4635 • FAX: 208-343-1858DATEPROJECT DRAWN REVISED CHECKED SHEET TITLE SHEET 200 BROAD STREET BOISE, ID 83702(208) 343-4635 • FAX (208) 343-1858www.cshqa.comJEFF T. WARD, P.E.reandpartners.com + 208-514-3300 + 1014 S. La Pointe, Boise, Idaho 83706LANDSCAPE ARCHITECTURE+ URBAN DESIGN+ LAND PLANNING+ GRAPHIC COMMUNICATION+ PROJECT MANAGEMENTLA-238STATE O F IDA H O LICENS E D LANDSCA P E ARCHITECTRODNEY P . EVAN S JR.LP RE CONSTRUCTION DOCUMENTS SYSTEM BALANCING: INITIAL STATION RUN TIMES: CONTROLLER SETUP: SYSTEM OPERATION: DRIP ZONES: SHRUBS - 6-7 MINUTE CYCLES. SPRAY ZONES: TURF - 5 MINUTE CYCLES. ROTOR ZONES: TURF - 5 MINUTE CYCLES. SYSTEM OPERATIONAL NOTES (BASED ON HISTORICAL CLIMATE) IRRIGATION NOTES 1.SYSTEM DESIGN BASED ON THE ASSUMPTION OF THE AVAILABILITY OF 26 G.P.M. WITH 40 P.S.I. AT THE SOURCE AND 40 P.S.I. AT THE HEADS. 2.ALL LATERAL LINES THAT ARE NOT LABELED SHALL BE 3/4" DIAMETER. 3.CONTRACTOR TO VERIFY LOCATION OF ALL UTILITIES PRIOR TO INITIATION OF ANY DEMOLITION OR CONSTRUCTION OPERATIONS. ANY DAMAGE TO EXISTING UTILITIES SHALL BE CONTRACTOR'S RESPONSIBILITY. 4.COORDINATE ALL IRRIGATION INSTALLATION OPERATIONS WITH CIVIL, MECHANICAL, AND ELECTRICAL ENGINEERING SHEETS. 5.CONTRACTOR SHALL COORDINATE INSTALLATION OF IRRIGATION CONDUIT AND SLEEVES UNDER HARD SURFACES WITH RESPECTIVE CONTRACTORS. 6.ALL SLEEVES SHALL BE INSTALLED AS PART OF IRRIGATION CONTRACT. APPROXIMATE LOCATION OF SLEEVES ARE SHOWN ON THE IRRIGATION PLAN. FIELD VERIFY LOCATION. ALL ENDS OF SLEEVES SHALL BE TAPED OR CAPPED AND MARKED WITH A 2"X 4" PAINTED STAKE EXTENDING TO 24" ABOVE GRADE. STAKES SHALL NOT BE REMOVED UNTIL THE IRRIGATION SYSTEM IS COMPLETE. ALL SLEEVES SHALL EXTEND A MINIMUM OF 18" BEYOND BACK OF CURB OR EDGE OF PAVEMENT. PROVIDE COMPACTED BACKFILL AS NECESSARY AT HARD SURFACE LOCATIONS. 7.CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND FEES REQUIRED FOR THIS WORK. 8.IRRIGATION CONTROLLER(S) ARE TO BE LOCATED AS SHOWN ON THE PLAN. CONTROLLERS SHALL BE WIRED TO POWER SUPPLY BY A LICENSED ELECTRICIAN PER LOCAL CODES. IRRIGATION CONTRACTOR TO PROVIDE ALL REQUIRED CONNECTIONS TO 24 VOLT IRRIGATION CONTROL WIRE INSIDE THE BUILDING THROUGH APPROPRIATE SIZED CONDUIT. 9.ALL ELECTRICAL WORK TO MEET OR EXCEED N.E.C., STATE CODES, LOCAL CODES, AND MANUFACTURER'S RECOMMENDATIONS. 10.CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL ROCK AND DEBRIS BROUGHT TO THE SURFACE AS A RESULT OF TRENCHING OPERATIONS. 11.CONTRACTOR SHALL REFER TO SPECIFICATIONS AND DETAIL DRAWINGS FOR ADDITIONAL REQUIREMENTS. 12.ALL 24 VOLT POWER WIRES SHALL BE #14 AWG COPPER. ALL ABOVE GROUND 120 VOLT AND 24 VOLT WIRE SHALL BE IN PVC CONDUIT. ONE POWER WIRE SHALL BE PROVIDED BACK TO THE CONTROLLER FOR EACH VALVE. ALL COMMON WIRES SHALL BE #12 AWG COPPER. ALL 24 VOLT WIRES SHALL BE TAPED TOGETHER AT TEN FOOT (10'-0") INTERVALS. 13.INSTALLATION SHALL COMPLY WITH ALL NATIONAL, STATE, AND LOCAL LAWS AND ORDINANCES. 14.IRRIGATION CONTRACTOR SHALL PROVIDE A COMPLETE AS-BUILT DRAWING IN PDF FORMAT UPON COMPLETION OF INSTALLATION AND PRIOR TO FINAL PAYMENT. 15.THE ENTIRE SYSTEM SHALL BE GUARANTEED TO BE COMPLETE AND PERFECT IN EVERY DETAIL FOR A PERIOD OF ONE YEAR FROM THE DATE OF ITS ACCEPTANCE; REPAIR OR REPLACEMENT OF ANY DEFECTS OCCURRING WITHIN THOSE TWO YEARS SHALL BE FREE OF EXPENSE TO THE OWNER. 16.AS PART OF THIS CONTRACT, PERFORM AT NO EXTRA COST WINTERIZATION AND SPRING START UP OF THE SYSTEM DURING THE GUARANTEE PERIOD (1 YEAR). 17.ALL MATERIALS SHALL BE NEW AND WITHOUT FLAWS OR DEFECTS OF THE QUALITY AND PERFORMANCE SPECIFIED, AND SHALL MEET THE REQUIREMENTS OF THIS SYSTEM. USE MATERIALS AS SPECIFIED, NO SUBSTITUTIONS SHALL BE PERMITTED WITHOUT PRIOR WRITTEN PERMISSION OF THE OWNER OR LANDSCAPE ARCHITECT. 18.IRRIGATION CONTRACTOR SHALL MAKE NECESSARY MINOR FIELD ADJUSTMENTS TO SPRINKLER NOZZLES, SPRINKLERS, PIPE, AND OTHER IRRIGATION EQUIPMENT LOCATIONS TO FIT THE AS-BUILT SITE. ADJUST HEAD AND PIPE LOCATIONS AS REQUIRED TO AVOID DAMAGING EXISTING TREE ROOTS. ADJUSTMENTS SHALL ENSURE HEAD TO HEAD COVERAGE AND NOT OVERSPRAY THE BUILDING OR OTHER IMPROVEMENTS. 19.IRRIGATION PIPING LAYOUT IS SCHEMATIC. WHERE LINES ARE SHOWN BELOW PAVEMENT ADJACENT TO LANDSCAPE AREAS, THEY SHALL BE LOCATED IN THE LANDSCAPE AREA UNLESS SHOWN WITH A SLEEVE SYMBOL. 20.BASE PLAN AND LOCATION OF EXISTING EQUIPMENT ARE SCHEMATIC IN NATURE. FIELD VERIFY ALL BASE AND EXISTING IRRIGATION ELEMENTS AND CONDITIONS PRIOR TO CONSTRUCTION AND PROVIDE NECESSARY ADJUSTMENTS. 21.IN THE EVENT OF A DISCREPANCY, IMMEDIATELY NOTIFY THE LANDSCAPE ARCHITECT. 1.THE PLANTER BEDS SHALL BE IRRIGATED WITH A NETAFIM DRIP IRRIGATION SYSTEM OR APPROVED EQUAL. THE CONTRACTOR IS RESPONSIBLE TO INSTALL THE DRIP SYSTEM AS PER DETAILS PROVIDED, MANUFACTURER'S RECOMMENDATIONS AND THE FOLLOWING REQUIREMENTS: A.NETAFIM TECHLINE HCVXR DRIP TUBING SHALL BE USED FOR FORMAL PLANTER BED AREAS, .53 GPH EMITTER @ 18" EMITTER SPACING AND 18" ROW SPACING SHALL BE USED. B.A LOW VOLUME CONTROL ZONE KIT SHALL BE INSTALLED PER EACH ZONE. SEE NOTES, LEGENDS AND DETAILS. C.ALL ZONES SHALL BE INSTALLED WITH A MANUAL LINE FLUSHING VALVE. SEE DETAIL. D.ALL DRIP TUBING SHALL BE BURIED AND STAKED TO PREVENT EXPOSURE OF PIPE THROUGH MULCH AS DETAILED. 2.THE CONTRACTOR SHALL BE RESPONSIBLE TO INSTALL THE DRIP SYSTEM SO THAT THE OPTIMUM AMOUNT OF WATER IS APPLIED TO ENSURE THE HEALTH OF ALL PLANT MATERIAL. EXTRA EMITTERS ARE TO BE INSTALLED AT ALL TREES PLANTED WITHIN THE PLANTER BEDS TO INSURE PROPER WATERING IF NECESSARY. 3.THE CONTRACTOR IS RESPONSIBLE TO SCHEDULE A MEETING WITH THE LANDSCAPE ARCHITECT AND THE OWNER'S REPRESENTATIVE BEFORE PROCEEDING WITH ANY IRRIGATION INSTALLATION IN ORDER TO REVIEW WORK TO BE DONE. 4.ALL PVC LATERAL LINES FROM VALVES TO HEADERS ARE TO BE BURIED AT MINIMUM DEPTH OF TWELVE INCHES (12"). SIZE AS NECESSARY. (SEE PIPE SIZING NOTES ON THIS SHEET.) 5.AFTER INSTALLATION OF THE IRRIGATION SYSTEM THE CONTRACTOR IS RESPONSIBLE TO PROVIDE THE OWNER WITH AS-BUILT DRAWINGS AND INSTRUCTIONS FOR MAINTENANCE OF THE DRIP SYSTEM. 6.PROVIDE NETAFIM TUBING AS PER DETAILS TO ENSURE EACH SHRUB AND TREE RECEIVES ADEQUATE IRRIGATION. BURY NETAFIM AS SPECIFED. ADJUST NETAFIM LOCATION TO OBTAIN COMPLETE COVERAGE. REFER TO NOTES FOR SPECIFICATIONS. DRIP IRRIGATION NOTES AS THE SYSTEM OPERATES, SOME ZONES WILL BE WET WHILE OTHERS ARE DRY. ADJUST ONLY THOSE STATIONS WHICH REQUIRE ADDITIONAL OR LESS WATER. FOR EXAMPLE, IF STATION #, A SPRAY ZONE IS ALWAYS DRY, CHANGE THE STATION RUN TIME FROM FIFTEEN (15) MINUTES TO SIXTEEN (16) MINUTES. CONTINUE MAKING ADJUSTMENTS UNTIL THE ZONE MOISTURE CONTENT IS ACCEPTABLE. USE NOZZLE CHANGES OR NOZZLE SCREW ADJUSTMENTS TO ADJUST WET AND DRY AREAS WITHIN A ZONE. A CYCLING TECHNIQUE WILL BE USED FOR APPLICATION OF WATER, EACH STATION RUN TIME WILL BE APPLIED WITH THREE (3) DIFFERENT START TIMES. THEREFORE STATION RUN TIMES REFLECT ONE THIRD (1/3) THE TOTAL APPLICATION. PEAK WATER APPLICATION WILL REQUIRE IRRIGATION EVERY NIGHT. SET CONTROLLERS FOR START TIME #1 AT 7:30P.M., START TIME #2 AT 12:00A.M., AND START TIME #3 AT 5:30A.M. EXTEND WATER WINDOW IF REQUIRED TO MEET PEAK WATER REQUIREMENTS. SCALE: 0 1"= 30'-0" 30 60 9030 OVERALL IRRIGATION PLAN 1 1 2 2 2 4 35 6 7676767 6 7 6 7 6 7 6 7 6 7 6 7 6 7 8 8 8 8 8 8 8 8 8 6 7