Loading...
Application Materials Planning Division DEVELOPMENT REVIEW APPLICATION Community Development  Planning Division  33 E. Broadway Avenue, Ste. 102 Meridian, Idaho 83642 Phone: 208-884-5533 Fax: 208-888-6854 www.meridiancity.org/planning -1 Rev:(2/11/2020) STAFF USE ONLY: Project name: File number(s): Assigned Planner: Related files: Type of Review Requested (check all that apply)  Accessory Use (check only 1)  Daycare  Home Occupation  Home Occupation/Instruction for 7 or more  Administrative Design Review  DR Modification  Alternative Compliance  Annexation and Zoning  Certificate of Zoning Compliance  CZC Modification  City Council Review  Comprehensive Plan Map Amendment  Comprehensive Plan Text Amendment  Conditional Use Permit  Conditional Use Permit Modification ( only 1)  Director  Commission  Development Agreement Modification  Final Plat  Final Plat Modification  Landscape Plan Modification  Preliminary Plat  Private Street  Property Boundary Adjustment  Rezone  Short Plat  Time Extension (check only 1)  Director  Commission  Council  UDC Text Amendment  Vacation (check only 1)  Director  Commission  Variance  Other Applicant Information Applicant name: Phone: Applicant address: Email: City: State: Zip: Applicant’s interest in property:  Own  Rent  Optioned  Other Owner name: Phone: Owner address: Email: City: State: Zip: Agent/Contact name (e.g., architect, engineer, developer, representative): Firm name: Phone: Agent address: Email: City: State: Zip: Primary contact is:  Applicant  Owner  Agent/Contact Subject Property Information Location/street address: Township, range, section: Assessor’s parcel number(s): __________________________ Total acreage: Zoning district: Community Development  Planning Division  33 E. Broadway Avenue, Ste. 102 Meridian, Idaho 83642 Phone: 208-884-5533 Fax: 208-888-6854 www.meridiancity.org/planning -2- Rev:(2/11/2020) Project/subdivision name: General description of proposed project/request: Proposed zoning district(s): Acres of each zone proposed: Type of use proposed (check all that apply):  Residential  Office  Commercial  Employment  Industrial  Other Who will own & maintain the pressurized irrigation system in this development? Which irrigation district does this property lie within? Primary irrigation source: Secondary: Square footage of landscaped areas to be irrigated (if primary or secondary point of connection is City water): Residential Project Summary (if applicable) Number of residential units: Number of building lots: Number of common lots: Number of other lots: Proposed number of dwelling units and square footage of living area (for multi-family developments only): 1 bedroom: 2–3 bedrooms: 4 or more bedrooms: (up to: 500 sq. feet) (up to: 250-500 sq. feet) (up to: 500 up to 1200 sq. feet) Minimum square footage of structure (excl. garage): Maximum building height: Minimum property size (s.f): Average property size (s.f.): Gross density (Per UDC 11-1A-1): Net density (Per UDC 11-1A-1): Acreage of qualified open space: __________________ Percentage of qualified open space: __________________ Type and calculations of qualified open space provided in acres (Per UDC 11-3G-3B): Amenities provided with this development (if applicable): Type of dwelling(s) proposed:  Single-family Detached  Single-family Attached  Townhouse  Duplex  Multi-family  Vertically Integrated  Other ____________________________________ Non-residential Project Summary (if applicable) Number of building lots: Common lots: Other lots: Gross floor area proposed: Existing (if applicable): Hours of operation (days and hours): Building height: Total number of parking spaces provided: Number of compact spaces provided: Authorization Print applicant name: Applicant signature: Date: e encompass inc. an idaho corporation Dennis Lee Taggart, Architect e encompass inc. 436 West Broadway, Meridian, ID 83642-2529 * Tel: 208/344-8800 Cell: 208/890-5434 * dennisleetaggart@gmail.com Date: April 8, 2020 To: City Of Meridian Planning and Development From: Dennis Taggart, Architect Re: CERTIFICATE OF ZONING COMPLIANCE BINARY SQUARE This is a new project on a bare lot located at the Southeast corner of N. Stonehenge and E. Fairview. The property is .42 acres zoned C-G. The proposed use is a “Vanilla Shell” for future potential clients of business, retail, food service tenants. Those improvements will be by subsequent permits. The planned building is located on an approved building pad and is 40’x100’ and about 4,000 sf. The maximum building height at the highest sloping roof peak is 26’-3”+/-. There is minimum 4’ parapet at the lower “flat” roof to screen mechanical equipment. Building materials include storefront windows and doors, stucco, Hardie Board, El Dorado Stone and stucco. There are window shades and a trellis area over the central “front” (east) elevation. There is significant variation to wall heights and materials. There are vine trellis at the rear (west) elevation as well as Storefront doors and window shades We are within the setbacks for landscaping for this site. We will be removing 2 trees and one shrub.  The Shrub along Fairview is a multi-stemmed plant that does bloom in the spring. However, due to the lack of care and pruning It has a “wild” appearance and is not a good plant at our “front door” on Fairview and blocks the indentifying sign location.  The Tree adjacent to the intersection of Stonehenge and Fairview appears to have been damaged as a 6” trunk has split up about 6”-8” into two 4” diameter trunks”. It has also been trimmed up about 3’, I assume because of vision at the intersection. This tree will likely never be long lived because of the split trunk which will be weak and will begin to weep as the two trunks most likely will grown together.  The third tree along Stonehenge has developed better with an 8” trunk. Unfortunately it was placed very near to the landscape setback line which means it will continually brush against the building even at this early stage of growth. It will also be misshaped with the natural growth restriction. Relocation might be a possibility, however there are power, communication and fiber optic cable in this location and likely would be risky to utilize a tree spade. Out plan is to replace this tree with others set back from the underground utilities and that are more columnar to provide interest with much less spread. encompass e encompass inc. 436 West Broadway, Meridian, ID 83642-2529 * Tel: 208/344-8800 Cell: 208/890-5434 * dennisleetaggart@gmail.com City of Meridian Planning and Development April 9, 2020 Page 2 There are 17 parking spaces provided on-site including 1 Van ADA space with loading zone. Actual parking requirement may vary with future tenant space but the parking provided is 1 space/235 sf. This exceeds the minimum for 100% restaurant and over 2x the standard requirement. This facility will most likely be mixed use tenants. There are no drive thru service drives planned or possible. Exterior lighting will be wall mounted sconce fixtures similar to the neighboring build to the south. There are existing roadway lighting at the intersection of the existing south drive and Stonehenge as well as throughout the existing development. Very truly yours, encompass inc. encompass e encompass inc. 436 West Broadway, Meridian, ID 83642-2529 * Tel: 208/344-8800 Cell: 208/890-5434 * dennisleetaggart@gmail.com City of Meridian Planning and Development April 9, 2020 Page 3 Dennis Lee Taggart, Architect President 1 Dennis Lee Taggart From:PlanningReview [PlanningReview@achdidaho.org] Sent:Tuesday, April 14, 2020 9:53 AM To:Dennis Lee Taggart Subject:RE: BINARY SQUARE Dennis,    A traffic impact study is not required for this application.    Please let me know if you have any questions.    Mindy      Mindy Wallace, AICP  Planning Review Supervisor  Ada County Highway District  208‐387‐6178      ACHD Development Services is open for business at our new location at 1301 N. Orchard Street, Suite 200 in the CSC building. Parking and building entrance are located on west side of building.       From: Dennis Lee Taggart <dennisleetaggart@gmail.com>   Sent: Thursday, April 09, 2020 1:35 PM  To: PlanningReview <PlanningReview@achdidaho.org>  Subject: BINARY SQUARE    [THIS EMAIL ORIGINATED EXTERNALLY. PLEASE USE CAUTION WHEN OPENING ATTACHMENTS OR LINKS INSIDE THIS EMAIL.] Greetings, Please find a copy of the proposed site and floor plan for a NEW BUILDING to be located at the corner of Stonehenge and Fairview in Meridian. The site is currently bare. There are no planned new roadway access to either Stonehenge or Fairview. We are applying for a CERTIFICATE OF ZONING COMPLIANCE with the City of Meridian. The planned use is a Vanilla Shell building for future TI improvement Permits for tenants when they are determined. Please advise if any fees and other documents are required at this point. 2 Thank you, as usual, for your assistance. Dennis Dennis Lee Taggart  Architect    Arizona . California . Colorado . Idaho . Kansas . Montana . New Mexico . North Carolina .Texas . Utah N.C.A.R.B., Certified: * A.S.I.D./NCIDQ Licensed Professional e encompass inc. 436 West Broadway Ave.  Meridian, ID. 83642  USA    USA             Ofc  208‐344‐8800                      Cell  208‐890‐5434    China           (86) 1350 1214 914 Beijing                       (86) 1506 1948 343 Changzhou   Skype           dtaggart1 (208‐629‐7970 Idaho, USA Skype #)  (+852 8170 3092 Hong Kong Skype #)       Right-click here to download pictures. To help protect yOutlook prevented automatic download of this picture frIn ternet. Virus-free. www.avg.com »Last Modified: 02/12/2016. Questions? Contact the Planning Division at 208.884.5533 or www.meridiancity.org Architectural Standards D esign R eview C heC klist | n on -R esi D ential Page | 1 Cohesive Design, non -ResiDential stanDaRDs (CDs) If a “N” or “N/A” is checked, please explain in comments. Y N N/A ID #Description Comments Staff Intent 1.00 Promote visually aesthetic building designs that incorporate quality architectural characteristics and establish built environments that are compatible with existing, planned, and anticipated adjacent land uses. Goal 1.10 Articulate building designs to frame and accentuate public spaces with pedestrian scale elements and details. Goal 1.11 Building design should address building scale, mass, form, and use a variety of materials and architectural features to ensure an aesthetic contribution compatible with surrounding buildings. 1.1A Maintain consistent and contiguous pedestrian environments across developments. Limit circuitous connections and maintain clear visibility. 1.1B Provide pedestrian connections to non-private public spaces. 1.1C Incorporate architectural features on all sides of a building façade facing: the primary entrance(s) of an adjacent building, public roadways, interior site amenities, and façades that are visible from public spaces. See Architectural Elements, Building Form, and Materials sections. 1.1D Buildings must orient, frame, and/or direct pedestrian views to adjacent cultural buildings, parks, and plazas. 1.1E Design and orient buildings not to impede access. The build- ing should enhance the appeal of open space and pedestrian environments Goal 1.20 Design building façades to express architectural character and incorporate the use of design principles to unify developments and buildings, and relate to adjacent and surrounding uses. 1.2A Comply and adhere with all previously required building design elements that were included as part of a Development Agree- ment, Conditional Use Permit, and/or other requirements as part of prior approval. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †NON-RESIDENTIAL STANDARDS | COMMERCIAL DISTRICTS †PROJECT INFORMATION Project Name: Applicant/Agent: File # OFFICIAL USEDate: »Last Modified: 02/12/2016. Questions? Contact the Planning Division at 208.884.5533 or www.meridiancity.org Architectural Standards D esign R eview C heC klist | n on -R esi D ential Page | 2 Cohesive Design, non -ResiDential stanDaRDs (CDs) If a “N” or “N/A” is checked, please explain in comments. Y N N/A ID #Description Comments Staff Goal 1.30 Incorporate design principles to include rhythm, repetition, framing, and/or proportion. Applies to all sides of a building façade facing public roadways, that are visible from residential neighborhoods or public spaces, or facing the public entry of an adjacent building. 1.3A Integrate at least one material change, color variation, or horizontal reveal for every 12-vertical feet of building façade; vertical spacing may be averaged over façade. 1.3B Integrate at least one material change, color variation, or vertical reveal every 50-horizontal feet of building façade; horizontal spacing may be averaged over façade elevation. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. BuilDing sCale, non -ResiDential stanDaRDs (Bss) If a “N” or “N/A” is checked, please explain in comments. Y N N/A ID #Description Comments Staff Intent 2.00 Promote building designs that use appropriate architectural and pedestrian scales to establish compatible physical and visual relationships with adjacent and surrounding developments and reinforce a cohesive built environment. Goal 2.10 Development should consider the scale of surrounding buildings, including relationships to existing residential areas, as well as an appropriate height, mass, and form scaled for the built environment. Applies to façades of development along public roads, public spaces, and adjacent to residential areas. 2.1A Buildings with rooflines 50-feet in length or greater must incor- porate roofline and parapet variations. Variations may include step-downs, step-backs, other modulation, or architectural features such as cornices, ledges, or columns, and must occur in total combination for at least 20% of the façade length. May be averaged over entire façade, but may not exceed 75-feet without a break. 2.1B For buildings with façades longer than 200-feet, reduce massing of buildings by grouping or incorporating smaller tenant spaces along the commercial façade, or by incorporating at least one significant modulation with depth at least 3% of the total façade length or 10-feet, and a width in combination at least 20% of the façade length. 2.1D Within mixed use areas and for all developments along arterial roadways, buildings over 1,000 sqft must provide a minimum 20-foot building elevation to include average parapet height, ridge of a pitched roof, or tower/turret type elements at least 20% in total of overall façade width. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †COMMERCIAL DISTRICTS | CONTINUED »Last Modified: 02/12/2016. Questions? Contact the Planning Division at 208.884.5533 or www.meridiancity.org Architectural Standards D esign R eview C heC klist | n on -R esi D ential Page | 3 BuilDing sCale, non -ResiDential stanDaRDs (Bss) If a “N” or “N/A” is checked, please explain in comments. Y N N/A ID #Description Comments Staff Goal 2.20 Physically configure building designs to reduce disproportioned architectural scale relative to adjacent uses. Applies to façades of development along public roads, public spaces, and residential areas. 2.2A For adjacent buildings with greater than 1-story height disparity (i.e. – two or more stories difference) and within 30-feet of each other, integrate and align parapet designs, material changes, fenestration alignment, material reveals, or other architectural elements and horizontal articulation, to relate varying building heights to one another. Aligned features do not have to be the same type (i.e. window pattern on one could align with parapet on another). 2.2B Use pedestrian scale and landscape design elements such as specialty lighting, awnings, trees or other site elements to visu - ally relate and transition multi-story buildings (or equivalent) to the ground plane. Goal 2.30 Incorporate pedestrian-scale architectural features to support an aesthetic character that contributes to the quality of the build- ing design and connectivity with the surrounding environment. Applies to façades in developments: visible from arterial or collector roadways, adjacent to residential developments facing roadways, facing an adjacent building's primary building entries, and adjacent to public spaces. 2.3A Consistently incorporate at least two (2) architectural features into the building design that are pedestrian scale, to include: fenestration patterns; architectural elements such as ledges, lighting, or canopies; material or pattern banding; or detailing (see Pedestrian Scale definition). Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. BuilDing FoRm, non-ResiDential stanDaRDs (BFs) If a “N” or “N/A” is checked, please explain in comments. Y N N/A ID #Description Comments Staff Intent 3.00 Promote building designs that articulate and define appropriate building forms with visual interest and enhance the character of the built environment. Goal 3.10 Articulate building forms, including but not limited to massing, walls, and roofs, with appropriately scaled modulations that contribute to the development of aesthetic building designs. Applies to façades in developments: along arterial and collector roadways, adjacent to residential developments facing roadways, facing public entries of adjacent buildings, and visible from public spaces. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †COMMERCIAL DISTRICTS | CONTINUED »Last Modified: 02/12/2016. Questions? Contact the Planning Division at 208.884.5533 or www.meridiancity.org Architectural Standards D esign R eview C heC klist | n on -R esi D ential Page | 4 BuilDing FoRm, non-ResiDential stanDaRDs (BFs) If a “N” or “N/A” is checked, please explain in comments. Y N N/A ID #Description Comments Staff 3.1A Incorporate at least one type of the following modulations in the façade plane, including but not limited to projections, recesses, and step backs that articulate wall planes and break up building mass. Examples include but are not limited to columns with trim or accent materials, change in finished material depths, building overhangs, and inset features and materials such as false windows or fenestration with architectural accents. 3.1B Qualifying modulation must be at least 6-inches in depth, be at least 8-inches in width or height (whichever is narrowest), and occur in total for 20% of overall façade elevation. For buildings with façades less than 150-feet, horizontal modulation must occur no less than every 30-feet. For buildings with façades greater than or equal to 150-feet, horizontal modulation must occur no less than every 50-feet. 3.1C Design parking structure façades as site integrated buildings, meeting applicable Manual standards for Architectural Elements and Material sections. Goal 3.20 Incorporate visual and physical distinctions in the building design that enhance building forms, articulate façades, identify entries, integrate pedestrian scale, and visually anchor the building to the ground or street level. Applies to building façades visible from a public street or public space, and to façades with public entries. 3.2A For at least 30% of applicable façades use any combination of concrete, masonry, stone, or unique variation of color, texture, or material, at least 10-inches in height, around the base of the building. May alternatively incorporate other architectural features such as ledges, façade reveals, ground level fenestra- tion, raised planters, or landscaping elements within 3-feet of finished grade. 3.2B Where building designs incorporate multiple stories, or multiple floor height equivalents, integrate at least one field or accent color, material, or architectural feature used on lower stories, on the upper stories. 3.2C Building designs with multiple stories must provide proportion- ally taller ground-level façades adjacent to public roadways and public spaces. Provide floor-to-ceiling heights, or floor-to-floor from 10 to 16 feet. 3.2D In mixed-use areas and for structures greater than four stories, design the uppermost story or façade wall plane to include material changes, horizontal articulation, and modulation meeting first story requirements, or include a patio, rooftop garden, penthouse, or strong architectural feature such as a tower element. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †COMMERCIAL DISTRICTS | CONTINUED »Last Modified: 02/12/2016. Questions? Contact the Planning Division at 208.884.5533 or www.meridiancity.org Architectural Standards D esign R eview C heC klist | n on -R esi D ential Page | 5 BuilDing FoRm, non-ResiDential stanDaRDs (BFs) If a “N” or “N/A” is checked, please explain in comments. Y N N/A ID #Description Comments Staff Goal 3.30 Building design should establish visual connections that relate internal spaces at ground- or street-level with facades adjacent to public roadways, public spaces, and along primary building entries, and that add visual interest and complexity to the first floor building design. 3.3A Use horizontal and/or vertical divisions in wall planes, such as ledges, awnings, recesses, stringcourse, molding, joint lines, or other material types, to frame and accent 30% or more of total fenestration. 3.3D Average 30% fenestration for applicable first floor façade, unless specified elsewhere. May also meet fenestration alternative (see 3.3E). Big box and buildings in industrial districts may limit applicable façade area to 30-feet around public entries. 3.3E Fenestration Alternative: Incorporate doors and windows for at least 30% of applicable first floor façade, or suggest their inclu- sion using faux treatments that incorporate at least two of the following: material changes, reveals in conjunction with color or material change, qualifying modulation such as recessed areas, architectural trellis, awnings and canopies over access areas, detached structures such as pergola, or similar architectural features and details. Goal 3.40 Building roof types, forms, and elements should provide variation and interest to building profiles and contribute to the architectural identity of the buildings, without creating an imposing scale on adjacent uses. Applies to façades: in development along arterial roadways, visible from residential development, adjacent to public spaces, facing public entries of adjacent buildings. 3.4A For flat roofs, incorporate primary and secondary roof elements including but not limited to: multiple material types along para - pets, multiple parapet elevations with at least 1-foot change in elevation, or modulation of at least 2-feet in the parapet, such as along entryway overhangs. Qualifying elements must exist for at least 20% the length of applicable façades. May also incorporate secondary roof types, such as hip roofs along overhangs. 3.4B For sloped roofs, incorporate at least two of any one roof element, including but not limited to: valleys, ridges, or gables. Qualifying elements in total must exist for at least 20% of applicable façade roof area and be visible from the same façade elevation. May also incorporate other roof styles, such as parapet walls over entryway features. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †COMMERCIAL DISTRICTS | CONTINUED »Last Modified: 02/12/2016. Questions? Contact the Planning Division at 208.884.5533 or www.meridiancity.org Architectural Standards D esign R eview C heC klist | n on -R esi D ential Page | 6 BuilDing FoRm, non-ResiDential stanDaRDs (BFs) If a “N” or “N/A” is checked, please explain in comments. Y N N/A ID #Description Comments Staff 3.4C Provide variation in roof profile over façade modulation and/ or articulation over façade material/color transitions. Options include, but are not limited to: varying parapet heights; two or more roof planes; continuation of façade modulation through roof lines; dormers; lookouts; overhang eaves; sloped roofs; or cornice work. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. aRChiteCtuRal elements, non-ResiDential stanDaRDs (ase) If a “N” or “N/A” is checked, please explain in comments. Y N N/A ID #Description Comments Staff Intent 4.00 Promote integrated architectural elements and details as compo- nents of cohesive building designs that enhance the visual interest of building façades, support activity at and/or near ground level, and provide pedestrian scale. Goal 4.10 Use proportional architectural elements and detailing to articulate façades, and contribute to an aesthetic building character with a high level of pedestrian design. Applies to façades: in development along public roadways, visible from residential development, adjacent to public spaces, facing public entries of adjacent buildings. Goal 4.11 Design and articulate architectural elements using proportions, divisions, detailing, materials, textures, and colors and appropriately integrate these elements into the building design. Applies to façades: in development along public roadways, visible from residential development, adjacent to public spaces, facing public entries of adjacent buildings. 4.1A Provide at least three detailing elements that transition façade material changes or integrate pedestrian scale elements, such as doorways, windows, or material banding, at the base of the building. Examples include but are not limited to: cornice work around primary entries, decorative caps on brick or stone banding, architectural canopies over entries, or decorative lintels above the first floor windows. 4.1B Provide building overhangs or other projections such as canopies which articulate the building façade and provide temporary relief from inclement weather. At a minimum, an overhang or projection is required within 20-feet of all public entryways, must be at least 3-feet in depth from the point of entry, and be least 6-feet in length. Entryways with vestibules or other permanent enclosed transition space are exempt. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †COMMERCIAL DISTRICTS | CONTINUED »Last Modified: 02/12/2016. Questions? Contact the Planning Division at 208.884.5533 or www.meridiancity.org Architectural Standards D esign R eview C heC klist | n on -R esi D ential Page | 7 aRChiteCtuRal elements, non-ResiDential stanDaRDs (ase) If a “N” or “N/A” is checked, please explain in comments. Y N N/A ID #Description Comments Staff 4.1C Provide details that emphasize focal elements such as public entries, building corners, or public spaces. Examples include but are not limited to: columns, quoin or rustication, canopies over entries, lintels, transom windows, or modulation of the roof plane. At least one focal element is required and must be accented with a unique combination of color, texture, materials, or modulation in the wall or roof plane. Goal 4.20 Building designs must not create blank wall segments when visible from a public street or public spaces. Consider the treatment at the base, middle, and top of the façade. 4.2A Use any combination of standards from Building Form, Architec - tural Elements, or Material sections to provide pattern, color, or material variation on all wall segments. Must not exceed 30-feet horizontally or vertically without building variation. Goal 4.30 Organize building service equipment, including, but not limited to, utility, service, and mechanical, away from building entries, roadways, public spaces, and, where appropriate, from adjacent buildings. 4.3A Use and integrate standards from the Architectural Standards Manual to screen and conceal service and mechanical equipment. Landscaping meeting the same intent may also be considered for utility meters and connections. 4.3B All ground level mechanical equipment must be screened to the height of the unit as viewed from the property line. 4.3C All rooftop mechanical equipment shall be screened as viewed from the farthest edge of the adjoining right of way. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. mateRials, non -ResiDential stanDaRDs (mas) If a “N” or “N/A” is checked, please explain in comments. Y N N/A ID #Description Comments Staff Intent 5.00 Use quality materials and colors that promote aesthetic building designs and contribute to the development of a timeless com- munity character. Goal 5.10 Use complementary material combinations that contribute to a cohesive building design. Use materials from the following basic groups: wood, masonry, concrete, stucco, metal, and glazing. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †COMMERCIAL DISTRICTS | CONTINUED »Last Modified: 02/12/2016. Questions? Contact the Planning Division at 208.884.5533 or www.meridiancity.org Architectural Standards D esign R eview C heC klist | n on -R esi D ential Page | 8 mateRials, non-ResiDential stanDaRDs (mas) If a “N” or “N/A” is checked, please explain in comments. Y N N/A ID #Description Comments Staff 5.1A For buildings with façades that face multiple public roadways and/or public spaces, use consistent material combinations, material quality, and architectural detailing. 5.1B For all façade elevations visible from public roads, public spaces, primary entrance(s) of an adjacent building, and facing residential districts, use at least two distinct field materials, colors, or material-color combinations on the building façade (see also Material definitions). 5.1D For façade elevations visible from public roadways and along primary building entryways, incorporate an accent material on the first story. 5.1E Distinguish field materials from accent materials through pat- tern, texture, or additional detail visible from edge of nearest roadway. Alternate masonry or material courses with relief from primary plane may count toward this. 5.1F Where materials transition or terminate, provide detailing to express the natural appearance of the material. For example, wrap stone or stone-like products around visible corners to convey the appearance of mass, and not as a thin veneer. 5.1G Non-durable materials, treatments, and finishes that deteriorate quickly with weather, ultra-violet light, and that are more suscep - tible to wear and tear are prohibited on permanent structures. 5.1H The use of vinyl and ordinary smooth face block, unfinished, colored, or painted, are prohibited as a field materials for building façades along public roadways, adjacent to public spaces, and when visible from residential neighborhoods. Smooth face block may be used as an accent material. 5.1I Untextured concrete panels and prefabricated steel panels are prohibited as field materials for building façades, except when used with a minimum of two other qualifying field materials and meeting all other standard fenestration and material requirements. Goal 5.20 Use colors that complement building materials and support innova- tive and good design practices. Applies to building façades visible from a public street, public spaces, and pedestrian environments. 5.2A Use of subtle, neutral, or natural tones must be integrated with at least one accent or field material. 5.2B Use of intensely saturated colors or fluorescence is prohibited as a primary material. May be used as an accent material. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †COMMERCIAL DISTRICTS | CONTINUED »Last Modified: 02/12/2016. Questions? Contact the Planning Division at 208.884.5533 or www.meridiancity.org Architectural Standards D esign R eview C heC klist | n on -R esi D ential Page | 9 mateRials, non-ResiDential stanDaRDs (mas) If a “N” or “N/A” is checked, please explain in comments. Y N N/A ID #Description Comments Staff 5.2C Materials or colors with high reflectance, such as some metals or reflective glazing, must not redirect light towards roadways, public spaces, or adjacent uses in a way which constitutes a public nuisance or safety hazard. Goal 5.30 Integrate roll-up doors, will-call doors, drive-through doors, and loading docks into the building design, and locate them in a manner which does not create pedestrian, drive aisle, or roadway conflicts. Applies to façades along arterial and collector roadways, and façades facing public spaces. 5.3A For commercial and traditional neighborhood districts, roll-up and drive-through doors are allowed when integrated into the building design, but will-call doors with roll-ups and loading docks are prohibited. Consider material variation and transitions, modulation, and other architectural features and standards for the design. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. signs & lighting, non -ResiDential stanDaRDs (sls) If a “N” or “N/A” is checked, please explain in comments. Y N N/A ID #Description Comments Staff Intent 6.00 Integrate signs and architectural lighting as cohesive elements of building designs that contribute to the atmosphere of the built environment and enhance safety. Goal 6.10 Use lighting on building exteriors to promote safe pedestrian environments along roadways, at intersections, and in public spaces. 6.1A Lighting fixture spacing and height along streetscapes and roadways must be placed to avoid conflicts with tree plantings. 6.1B Use energy-efficient architectural lighting. 6.1C Use lighting fixtures that are consistent with other decorative hardware on the building. For example, select lighting hardware with similar color and shape as other building hardware, use recessed lighting, incorporate uniform spacing, integrate with other accents and reveals, and coordinate specialty lights with predominate architectural features. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †COMMERCIAL DISTRICTS | CONTINUED       Good Morning Dennis,    The plans look great and meet all requirements of Republic Services.    We do not stamp plans but give approval through email per the plans attached and you have the  approval of Republic Services that the plans attached meet the requirements.    Any questions please reach out.    Have a great day    Jay      DLT REVISION DATE PROJECT NO. DRAWN BY: DATE: SHEET NO. OWNERSHIP OF DOCUMENTS Copyright C Architect whether the Project for which they are made is executed or not. They are not to be used byencompass, inc.DENNIS LEE TAGGART, Architectare and shall remain the property of Dennis L. Taggart, appropriate compensation to Dennis L. Taggart, Architect the Owner on this or other projects or extensions to this project except by agreement in writing and with A1 2020 Dennis L. Taggart, Architect APR 8, 2020436 WEST BROADWAY AVENUE, MERIDIAN, IDAHO 83642OFFICE (208) 344-8800e-mail dennisleetaggart@gmail.comARIZONA . CALIFORNIA . COLORADO . IDAHO . KANSAS MONTANA . NORTH CAROLINA . NEW MEXICO . TEXAS . UTAHfor1/8" Scale Floor Plans STATE OF IDAHO AR-1262 LICENSED ARCHITECT DENNIS LEE TAGGART 04-08 - 2 0 2 0 SCALE: 1/8" = 1’-0" MULTI-TENANT BUILDING -FLOOR PLAN NORTH4,000 sf BINARY SQUAREMULTI-TENANT RETAIL BUILDING2ENVISION 360, INC.104 E. Fairview Ave, Ste 233Meridian, Idaho 8364233’-4"33’-4"33’-4"100’-0"40’-0"16’-8"16’-8"ChadO MT 20.1 N.C.A.R.B., Certified: * A.S.I.D. / NCIDQ Licensed Professional 16’-4"2’-10"20’-10" 9’-10"6’-6"10’-6"10’-4"1’-10 1/2 "10’-4"10’-6"9’-4"24’-0"16’-8"14’-6"2’-2"24’-0"9’-4"5’-0"5’-0"6’-0"3’-0" 2’-0"3’-0"6’-0"3’-0"2’-10"5’-8"12’-8"6’-7"2’-10"6’-7"12’-8"5’-8"2’-10"10’-6"10’-4"1’-10 1/2 "6’-9"2’-3"2’-1 1/2 " 9’-10"6’-6"2’-10"10’-6"10’-4" 40’-0"3’-0"3’-0"10’-8"42’-0"5’-0"6’-0"5’-0"2’-0"17’-0"25’-0"9’-0"5’-0"+/-2’-3"6’-9"1’-10 1/2 " SUITE "A" SUITE "B" SUITE "C"2’-5 1/2 "2’-5 1/2 "3’-5 1/2 "8’-7"10’-8"6’-0"6’-0"10’-8"8’-7"Vine Trellis Vine Trellis Vine Trellis Vine Trellis < < < < Planter Planter Planter Planter Planter Planter Planter Planter Planter Planter Planter Planter Planter10’-0"3’-0"9’-4"9’-0" (min)9’-0" (ytyp)23’-0"(typ)23’-0" (typ) Loading / Turn-Around PlanterPlanterPlanterPlanterPlanter19’-0" (typ)5’-10"6’-0"6’-0"5’-0" See Civil Drawings For Lot Boundry Info13’-4"See Civil Drawings For Grading/Drainage And Storm Water Info Potential Future Restroom Locations By Separate TI Permit House Elec Panel Room D-1 D-2 W-1 D-3 D-4 D-5 D-6 D-7 D-8 D-9 D-10 W-2 W-3 W-4 6’-6"2’-0"Trans Pwr Box Pwr Box Relocate Tele Existing Sidewalk Existing Sidewalk Existing Sidewalk Existing Sidewalk Existing Sidewalk Existing Utilities Existing Utilities Existing Utilities Remove Tree Remove Tree N. STONHENGE WAYE. FAIRVIEW AVE. Existing In This Area The Length Of The Roadway--- ^ Power ^ Tele ^ Pressure Irrigation Locate and Adjust As Neccessary- Coordinate With Landscape Plan Coordinate With Architect/Engineers An Utilities CutBerm For Sidewalk 1/20 Max Slope CutBerm For Sidewalk 1/20 Max Slope CutBerm For Sidewalk 1/20 Max Slope CutBerm For Patio 1/20 Max Slope Existing Irrigation Back Flow Valve Bicycle Parks (2) Bicycle Parks (2) 3’-0"5’-0"6’-0"5’-0"6’-0"Remove Shrub 3’-6"2’-4"3’-6"9’-4"5’-0"3’-6"5’-0"5’-0" Ramp 1/12 Ramp 1/12 Ramp 1/12 Ramp 1/12 (3) R Dn 13’-0"6" Curb6" Curb20" high Decorative CMU Retaining Walls PlanterExistingBermExistingBermLawn OnExisting Berm12’-6" 6’x8’x16" CMU x 6’-0"h Trash Enclosure Stucco Exterior Metal Gates w/120^ Hold Open 4" Conc Floor 57’-0"67’-6 1/8 " 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16VAN17 DLT REVISION DATE PROJECT NO. DRAWN BY: DATE: SHEET NO. OWNERSHIP OF DOCUMENTS Copyright C Drawings and Specifications as instruments of service Architect whether the Project for which they are made is executed or not. They are not to be used byencompass, inc.DENNIS LEE TAGGART, Architectare and shall remain the property of Dennis L. Taggart, appropriate compensation to Dennis L. Taggart, Architect the Owner on this or other projects or extensions to this project except by agreement in writing and with N.C.A.R.B., Certified: * A.S.I.D. Licensed Professional A7 2020 Dennis L. Taggart, Architect436 WEST BROADWAY AVENUE, MERIDIAN, IDAHO 83642OFFICE (208) 344-8800e-mail dennisleetaggart@gmail.comARIZONA . CALIFORNIA . COLORADO . IDAHO . KANSAS MONTANA . NORTH CAROLINA . NEW MEXICO . TEXAS . UTAHAPR 8, 2020 1/2" Scale Details STATE OF IDAHO AR-1262 LICENSED ARCHITECT DENNIS LEE TAGGART 04-08 - 2 0 2 0 4’-0"6"16’-0"2’-0"4’-0"4’-0"4’-0"2’-0"Exterior Wall Assembly 2x6 Blocking At Mounting Brackets Lattice Frame And 2"x2" WW Wire Powder CoatFinish To Be SherwinWilliams - SW 7069 Iron Ore (2) 1/2"~ Thru Bolts To Trellis Frame and (2) 1.2"~ Lag Bolts Thru To Blocking 2x6 Blocking At Mounting Brackets 3x3x1/8 Lattice Frame All Around and 3x3x1/8 x 5"Lg Wall Bracket With Slotted Holes For Trellis Bolts With Wall Leg To Inside Of Trellis Frame 3x3x1/8 Trellis Frame All Around and 3x3x1/8 x 5"Lg Wall Bracket With Slotted Holes For Trellis Bolts With Wall Leg To Inside Of Trellis Frame (2) 1/2"~ Thru Bolts To Trellis Frame and (2) 1.2"~ Lag Bolts Thru To Blocking Exterior Wall Assembly Trellis Frame And 2"x2" WW Wire Powder Coat Finish To Be SherwinWilliams - SW 7069 Iron Ore 3" Angle Frame All Around Mounting Brackets- See Details 2"x2" Woven Wire Mesh Lattice Screen SCALE: 1/2" = 1’-0" VINE LATTICE VINE LATTICE SECTION VINE LATTICE PLAN SCALE: 1" = 1’-0" SCALE: 1" = 1’-0"13’-6"3’-6"4’-0"12’-0"21’-0"Extend Roofing To Top Of Conc Wall Panel With 2: Wall Cap Flashing At highestPoint ofRoofEFIS Stucco w/1" Insulation Fire Block at Ceiling and +10 ff 7"6’-0"6’-0"14" Max12" Typ3/4" ~ Rungs34"-38"Provide Blocking at Each Ladder Bracket Lockable No-Access Hinged Cover Lockable No-Access Hinged Cover 2’-0" 3’-0" Parapet Opening Outside Max 16" Min Clr Vine Lattice Service Door Open Parapet To Roof Access Brace Bottom Of Rail To Wall Below Grip Flash Low Parapet Opening SCALE: 1/2" = 1’-0" ROOF ACCESS LADDER ELEVATION SECTION forBINARY SQUAREMULTI-TENANT RETAIL BUILDING2ENVISION 360, INC.104 E. Fairview Ave, Ste 233Meridian, Idaho 83642ChadO MT 20.1 UTILITY UTILITY REPRESENTATIVES REPRESENTATIVES PHONE WATER IV TP EROSION CONTROL MERIDIAN, IDAHO 83642 1321 E. RFAIRVIEW AVE CITY OF MERIDIAN, ADA COUNTY, IDAHO LOT 1 BLOCK 1 BINARY SQUARE SUBDIVISION BINARY SQUARE TITLE SHEET FOR LYING IN THE 1/4, SECTION 7, T3N., R1E., B.M. “ ” TP TOS EL. 2605.30 MATCH EXISTING TOC EL. ±2606.07 MATCH EXISTING TOC EL. ±2606.21 MATCH EXISTING TOC EL. ±2605.72 MATCH EXISTING TOC EL. ±2605.66 MATCH EXISTING TOC EL. ±2605.51 MATCH EXISTING TOC EL. ±2605.46 MATCH EXISTING TOC EL. ±2605.20 MATCH EXISTING TOC EL. ±2605.31 MATCH EXISTING TOC EL. ±2607.78 MATCH EXISTING TOC EL. ±2607.80 TOW EL. 2607.96 TOW EL. 2608.03TOW EL. 2607.61 TOW EL. 2607.48 EG EL. 2606.98 EG EL. 2607.11 EG EL. 2607.54 EG EL. 2607.46 EG EL. 2607.58 EG EL. 2607.58TOW EL. 2608.08 MATCH EXISTING TOC EL. ±2605.56 TP 010 10 20 405 TP 010 10 20 405 DLT REVISION DATE PROJECT NO. DRAWN BY: DATE: SHEET NO. OWNERSHIP OF DOCUMENTS Copyright C Architect whether the Project for which they are made is executed or not. They are not to be used byencompass, inc.DENNIS LEE TAGGART, Architectare and shall remain the property of Dennis L. Taggart, appropriate compensation to Dennis L. Taggart, Architect the Owner on this or other projects or extensions to this project except by agreement in writing and with 2020 Dennis L. Taggart, Architect APR 8, 2020436 WEST BROADWAY AVENUE, MERIDIAN, IDAHO 83642OFFICE (208) 344-8800e-mail dennisleetaggart@gmail.comARIZONA . CALIFORNIA . COLORADO . IDAHO . KANSAS MONTANA . NORTH CAROLINA . NEW MEXICO . TEXAS . UTAHforSTATE OF IDAHO AR-1262 LICENSED ARCHITECT DENNIS LEE TAGGART 04-08 - 2 0 2 0 SCALE: 1/8" = 1’-0"NORTH4,000 sf BINARY SQUAREMULTI-TENANT RETAIL BUILDING2ENVISION 360, INC.104 E. Fairview Ave, Ste 233Meridian, Idaho 8364240’-0" ChadO MT 20.1 N.C.A.R.B., Certified: * A.S.I.D. / NCIDQ Licensed Professional 6’-0"40’-0"3’-0"10’-8"42’-0"5’-0"6’-0"5’-0"2’-0"17’-0"25’-0"9’-0"5’-0"+/- SUITE "A" SUITE "B" SUITE "C" Vine Trellis < Planter Planter PlanterPlanter Planter Planter Planter Planter Planter Planter10’-0"9’-4"9’-0" (min)9’-0" (ytyp)23’-0"(typ)Loading / Turn-Around PlanterPlanterPlanterPlanterPlanter19’-0" (typ)5’-10"6’-0"6’-0"5’-0" See Civil Drawings For Lot Boundry Info13’-4"See Civil Drawings For Grading/Drainage And Storm Water Info W-2 6’-6"Trans Pwr Box Pwr Box Existing Sidewalk Existing Sidewalk Existing Sidewalk Existing Sidewalk Existing Sidewalk Existing Utilities Existing Utilities Existing Utilities Remove Tree Remove Tree N. STONHENGE WAYE. FAIRVIEW AVE. Existing In This Area The Length Of The Roadway--- ^ Power ^ Tele ^ Pressure Irrigation Locate and Adjust As Neccessary- Coordinate With Landscape Plan Coordinate With Architect/Engineers An Utilities CutBerm For Patio 1/20 Max Slope Existing Irrigation Back Flow Valve Bicycle Parks (2) Bicycle Parks (2) 3’-0"5’-0"6’-0"5’-0"6’-0"Remove Shrub 3’-6"2’-4"3’-6"9’-4"5’-0"3’-6"5’-0"5’-0" Ramp 1/12 Ramp 1/12 Ramp 1/12 Ramp 1/12 (3) R Dn 6" Curb6" Curb20" high Decorative CMU Retaining Walls ExistingBermLawn OnExisting Berm23’-0" Typ 12’-6" 6’x8’x16" CMU x 6’-0"h Trash Enclosure Stucco Exterior Metal Gates w/120^ Hold Open 4" Conc Floor 2’-0"3’-0"3’-0" 4’-4"ExistingBermPlanter25’-0"Landscape EasementLandscape Easement 10’-0" New Sidewalk Entry No Guardrail Required (6" Max Slope At Ramp Runs) CutBerm For Sidewalk 1/12 6’-Run Max Slope CutBerm For Sidewalk 1/12 6’-Run Max Slope 11’-0"2’-4"+/-LandscapeSetackPlanter PlanterPlanter PlanterPlanterPlanterPlanterPlanter Planter Building PadBuilding Pad100’-0"Building Pad Utility Easement-See Civil Drawings <ExistingBermPlanterCutBerm For Sidewalk 1/12 6’-Run Max Slope Remove Tree MULTI-TENANT BUILDING -SITE PLAN AS-1 1/8" Scale Site Plan 57’-0"67’-6 1/8 " 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16VAN17