PZ - Fire Access Plan (Q) U
PARADIGM DESIGN
ARCHITECTS I ENGINEERS ini
HENRICKSON
4650 E Cotton Center Blvd, Suite 110 ARCHITECTURE + PLANNING
Phoenix,AZ 85040 100 Grandville,Suite 030
(602)374-4066 Grand Rapids,MI 49503
616.458.5554
Grand Rapids I Phoenix I Traverse City
www.paradigmae.com
JOB#1912192PH
/ I i EXISTING30'CREASON FIRM#3856 (EXP.01/31/2021)
/ I
LATERAL EASEMENT
I — I
j NO PARKING-FIRE LANE
I SIGN, 12 INCH x 18 INCH WHITE REFLECTIVE
I \� RED PAINTED CURB III I i BACKGROUND WITH RED LETTERS (TYP.)
I ALONG FIRE LANE (TYP.) i-1CD
I I I PROPOSED 30 WATER
�,/ CD
S01 00'44"W 774.77' &SEWER EASEMENT I I
f7 f O
X _ I IR IRX IR IR X IR IR X IR—IF R IR IR X IR IR X —IR X' „k�X R R R R I -I —IR IR IR— --I / d
I
I � — - - - - - - - - - - - - - - - - - - - - - - - - -- - \ � R30'- —IR —I -
$�'\\� EXISTING
WILLIS M. HADLOCK Jrz., P.E.
I
I I w 30'CREASON EXP. DATE ❑1/3 1/2D2 1
N R20'` I I LATERAL
EASEMENT
y- I I I o
- - - - � I I I I ,
IY \ H�++H I I " I I o I S M
I I Q
> co
I 150' � \ I I m
I� HOSE LAY � \\� I I I I Q 0)
o
II / / - ��\ ✓ I I I II IIII IIII
oo
M L, n3 Z
U_ I -n a
Z.I w
o HOSELAY m 60' PROPOSED I_o 1 0 LU
LU
20'WATER I I I I
I� X — —X X / I EASEMENT I I I I I o
�
PROPOSED BUILDING 1 I I I I
z
1 FFE=2529.50 I I I I z >
42,408 SFT 1 i I I I J o
w
on
FIRE HYDRANT LOCATION I I I I LO
o
FIRE HYDRANT LOCATION I I I I _ z z
O (/� O
El\ \ I I NO PARKING-FIRE LANE
- \ SIGN, 12 INCH x 18 INCH WHITE REFLECTIVE
PROPOSED 20' 1 I —J I I LU
47' — — BACKGROUND WITH RED LETTERS (TYP.)
L x, WATER EASEMENT z I I I I O Z
PROPOSED X
- - - ROW j I I I U Q 3
+ X + ——— I I
z
--- —
� - R20 R20' R41 A I I— —I —I I I I I I I I — — I I I I I I — — — — — — — — — — I I � I PROPOSED
I I I R15.5' R30' I 14'MULTI-USE Q
p
I I R15.5' i EASEMENT w a
o
cYi
L`BF BF BF BF BF "V V V V V V V V V V V T — — �' CLUNO PARKING-FIRE LANE o , — LL R46' iR30' H
' PROPOSED
�IF
SIGN 12 INCH x 18 INCH IF // I 30'SEWER C of
^ I I EASEMENT O w
WHITE REFLECTIVE i I x
BACKGROUND WITH RED PAINTED CURB , I I F I I 1 NO PARKING-FIRE LANE H
ALONG FIRE LANE (TYP.)
RED LETTERS (TYP.) I I \ \ I I SIGN, 12 INCH x 18 INCH _
LJJ I I ( _ i WHITE REFLECTIVE w o
10 BACKGROUND WITH
RED PAINTED CURB \ / I i RED LETTERS (TYP.) i
ALONG FIRE LANE (TYP.) I I� __� J- z
F IIf41
Now
�� I � a
35'LA DSL{APE B(16FE
—___— -- -- ---- — — — — — _2-5'—FRONT BUIL
-- — — ----- --- --
----------- --o--- I
\ o
II
T
c>
Lrl_ __ -------- _----- --- \
— ————————— ---- ---- _ — — — — — — — — ----_ — ------- —
27'
N o PROPOSED PROPOSED
w R INMULTI USE EASEMENT
— -
- - - — —
S01'00'44"W 540,97' o N. MC D E R MO TT R D. N01°00'44"E 774.50' S01°00'44"W 1315.33'
z
Q —
-E OH-E OH-E US d OH-E OH-E OH-E OH-E OH-E OH-E OH-E OH-E PROPOSED LEGEND
® WATER METER HYDRANT ® WATER VALVE
FIRE APPARATUS ACCESS ROAD
WATER MAIN WATER SERVICE J
HOSE LAY
_FL— — —FL— FIRE LANE(NOT MARKED IN FIELD)
n
C.�
0
50 S Cole Rd
DIGUInise, 2- 585 =
Q
Inc-lino_ 800-34185
Call Before You Dig! 208-342-1585
DRAWN BY: JL
CHECKED: DF
NOTE: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES, CONDUITS OR FIRE ACCESS PLAN
STRUCTURES SHOWN ON THESE PLANS WAS OBTAINED BY A SEARCH OF THE AVAILABLE
RECORDS. TO THE BEST OF OUR KNOWLEDGE, THERE ARE NO EXISTING UTILITIES EXCEPT AS A'
SHOWN ON THESE PLANS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY I V
MEASURES TO PROTECT THE UTILITY LINES SHOWN ON THESE DRAWINGS. THE CONTRACTOR
FURTHER ASSUMES ALL LIABILITY AND RESPONSIBILITY FOR THE UTILITY PIPES, CONDUITS AND
STRUCTURES SHOWN OR NOT SHOWN ON THESE DRAWINGS. THE CONTRACTOR SHALL PROJECT No. • 1912192PH
POTHOLE ALL EXISTING UTILITIES TO VERIFY THE LOCATION AND ANY DISCREPANCY BETWEEN
THE PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER. o ao so'
C=1 05