Loading...
Moorhouse Office Complex_DrawingsANDANGLEATCENTERLINEDEGREEDIAMETERPLATEPLUS OR MINUSPOUND, NUMBERANCHOR BOLTAIR CONDITIONINGACOUSTICALACOUSTICAL CEILING TILEADDITIONADJACENTABOVE FINISHED FLOORSAIR HANDLING UNITSALTERNATEALUMINUMANCHORANGLEANODIZEDAPPROXIMATEARCHITECTASPHALTASSEMBLYASSOCIATEDBOTTOMBALLED AND BURLAPPEDBOTTOM OFBOARDBITUMINOUSBUILDING LINEBUILDINGBLOCK(ING)BEAM/BENCH MARKBASE OF CURBBOTTOMBEARINGBRICKBASEMENTBUILT-UP ROOFINGCABINETCALIPERCATCH BASINCEILING DIFFUSERCEMENTCUBIC FEET -MINUTECORNER GUARDCAST IRONCONTROL JOINTCEILINGCAULKCLEARCONCRETE MASONRY UNITCLEAN OUTCOLUMNCONCRETECONNECTIONCONSTRUCTIONCONTINUOUSCONTRACT(OR)CARPETCEILING REGISTERCOUNTERSINKCERAMIC TILECENTERCONDENSING UNITCABINET UNIT HEATERCOLD WATER&<@°Ø±#A.B.A/CACOUS.A.C.T.ADDN.ADJ.A.F.F.A.H.U.ALT.ALUM.ANCH.ANG.ANOD.APPROX.ARCH.ASPH.ASSBY.ASSOC.BOT.B&BB.O.BD.BIT.B.L.BLDG.BLK'G.BM.B.O.C.BOTT.BRG.BRK.BSMT.B.U.R.CAB.CAL.C.B.C.D.CEM.C.F.M.C.G.C.I.C.J.CLG.CLK.CLR.C.M.U.C.O.COL.CONC.CONNCONST.CONT.CONTR.CPT.C.R.C.SK.C.T.CTR.C.U.C.U.H.C.W.DOUBLEDEPARTMENTDETAILDRINKING FOUNTAINDIAMETERDIMENSIONDISPENSERDEAD LOADDRAINAGE MANHOLEDOWNDISTRIBUTION PANELDOORDOWNSPOUTDRAWINGEASTEACHEXPANSION BOLTEPOXY FLOORINGEXTERIOR INSULATIONFINISH SYSTEMEXPANSION JOINTELEVATORELEVATIONELECTRICALEMERGENCYENCLOSUREENGINEERELECTRICAL PANELETHYLENE PROPYLENE DIENE MONOMEREQUALEQUIPMENTEACH WAYELECTRIC WATER COOLERELECTRIC WATER HEATEREXHAUSTEXISTINGEXPANSIONEXTERIORFIRE ALARMF.A. CONTROL PANELFLOOR DRAINFOUNDATIONFIRE EXTINGUISHERFIRE EXTINGUISHER CABINETFINISHED FLOORFINISHED GRADEFIRE HYDRANTFIRE HOSE CABINETFINISH(ED)FIXTUREFLOW LINEFLASHINGFLOOR(ING)FLUORESCENTFACE OFFACE OF CONCRETEFACE OF FINISHFACE OF MASONRYFACE OF STUDFIREPROOFFIRE PROOFFIBER REINFORCED PANELFLOOR SINKFOOT, FEETFOOTINGFURNISH(ED)FURRINGFABRIC WALL COVERINGDBL.DEPT.DET.D.F.DIA.DIM.DISP.D.L.D.MH.DN.D.P.DR.D.S.DWG.E.EA.E.B.E.F.E.I.F.S.E.J.EL.ELEV.ELEC.EMERG.ENCL.ENGR.E.P.E.P.D.M.EQ.EQUIP.E.W.E.W.C.E.W.H.EXH.(E)EXP.EXT.F.A.F.A.C.P.F.D.FDN.F.E.F.E.C.F.F.F.G.F.H.F.H.C.FIN.FIXT.F.L.FLASH.FLR.(G)FLUOR.F.O.F.O.C.F.O.F.F.O.M.F.O.S.FP.F.PR.F.R.P.F.S.FT.FTG.FURN.FRR.F.W.C.GAUGE, GAGEGALVANIZEDGRAB BARGENERAL CONTRACTORGROUND FAULT INTERRUPTERGALVANIZED IRONGYPSUMHOSE BIBBHOLLOW COREHARDWOODHARDWAREHEIGHTHIGH INTENSITY DISCHARGEHOLLOW METALHOLD OPENHORIZONTALHIGH POINTHOURHEIGHTHEAT, VENT, A/CHOT WATERINSIDE DIAMETERINCHINCANDESCENTINCLUDE (D) (ING)INSULAT(ED)(ION)INTERIORINVERTJANITORJUNCTION BOXJOINTKIP (1,000 POUNDS)KIP FEETKEYBOARDKITCHENKNOCK OUTLAMINATEDLAVATORYPOUND(S)LEAD COATED COPPERLINEAR FEETLEFT HANDLIVE LOADLONG LEG HORIZONTALLONG LEG VERTICALLOW POINTLIGHTING PANELLIGHT (ING)LIGHTWEIGHTMAGNETICMASONRYMATERIALMAXIMUMMACHINE BOLTMAIN DISTRIBUTION PANELMECHANICALMEDIUMMEMBRANEMETALMANUFACTURERMANHOLEMINIMUMMISCELLANEOUSMASONRY OPENINGMOISTURE RESISTANTMOUNTEDGA.GALV.G.B.G.C.G.F.I.G.I.GYP.H.B.H.C.HDWD.HDWR.HGT.H.I.D. H.M.H.O.HORIZ.H.P.HR.HT.HVACH.W.I.D.IN.INCAND.INCL.INSUL.INT.INV.JAN.J.B.JT.KK-FT.KB.KIT.K.O.LAM.LAV.LB.(S)L.C.C.L.F.L.H.L.L.L.L.H.L.L.V.L.P.LT.P.LT.(G)LTWT.MAG.MAS.MAT.MAX.M.B.M.D.P.MECH.MED.MEMB.MTL.MFR.M.H.MIN.MISC.M.O.M.R.MTD.PRNORTHNOT IN CONTRACTNUMBERNOMINALNOT TO SCALEOVERON CENTER(S)OUTSIDE DIAMETEROFFICEOWNER FURNISHEDCONTRACTOR INSTALLEDOWNER FURNISHEDOWNER INSTALLEDOPEN ITEMOPENINGOPPOSITEORIENTED STRAND BOARDOUT TO OUTOUNCEPROPERTY LINEPROJECT ARCHITECTPARTICLE BOARDPOUNDS -CUBIC FOOTPERFORATEDPLATEPLASTIC LAMINATEPLASTERPLUMBINGPOUNDS -LINEAR FOOTPLYWOODPANELPOLISH(ED)POWER PANELPAIRPROJECTPARTITIONPOUNDS -SQUARE FOOTPOUNDS -SQUARE INCHPAINT/ POINTPAINTEDPLUMBING VENTPOLYVINYL CHLORIDEPAVEMENTQUARRY TILEQUANTITYRADIUSRUBBER BASEREFLECTED CEILING PLANROOF DRAINREFERENCERECESSEDRECEPTACLEREFRIGERATORREINFORCE (D) (ING)REQUIREDRESILIENTREVISIONS, REVISEDROOFINGRIGHT HANDROOMROUGH OPENINGRIGHT OF WAYRESTROOMROOF TOP UNITRAIN WATER LEADERROOF VENTNN.I.C.NO.NOM.N.T.So'O.C.O.D.OFF.O.F.C.I.O.F.O.I.O.I.OPG.OPP.O.S.B.O.T.O.OZ.P/LP.A.P.BD.P.C.F.PERF.PLP.LAM.PLAS.PLBG.P.L.F.PLYWD.PNL.POL.P.P.PR.PROJ.PRTN.P.S.F.P.S.I.PT.PTD.P.V.PVCPVMT.Q.T.QTY.RR.B.R.C.P.R.D.RE.REC.RECPT.REF.REINF.REQ.RESIL.REV.RFG.R.H.RM.R.O.R.O.W.R.R.R.T.U.R.W.L.R.V.SOUTHSANITARYSUSPENDED ACOUSTICALCEILINGSOLID CORESCHEDULESTORM DRAINSEALANTSECTIONSERVICESQUARE FEETSAFETY GLASSSHEETSHEATHINGSHOWERSIMILARSHEET METALSANITARY MANHOLESHEET METAL SCREWSSPRAY ON VINYLSPECIFICATIONSSQUARESOLID SURFACESTAINLESS STEELSTANDARDSTEELSTORAGESTRUCTURALSTORM SEWERSUSPENDEDSYMMETRICALSYSTEMTREADTOWEL BARTOP OFTONGUE AND GROOVETELEPHONETEMPERATURE, TEMPEREDTHICKTHRESHOLDTOILET PARTITIONTOILET PAPER DISPENSERTYPICALTELEVISIONUNIT HEATERUNLESS NOTED OTHERWISEUNFINISHEDULTRA VIOLETVINYL COMPOSITION TILEVENTILATIONVERTICALVESTIBULEVERIFY IN FIELDVINYLVINYL WALL COVERINGWESTWITHWATER CLOSETWOODWATER HEATERWINDOWWATERPROOFWATER RESISTANTWAINSCOTWEIGHTWATER VALVEWELDED WIRE FABRICYARDSSAN.S.A.C.S.C.SCHED.S.D.SEAL.SECT.SERV.S.F.S.G.SHT.SHTHG.SHWR.SIM.S.M.S.MH.SMSS.O.V.SPEC.SQ.SSS.STL.STD.STL.STOR.STRUCT.S.S.SUSP.SYM.SYS.T.T.B.T.O.T&GTEL.TEMP.THK.THRES.T.P.T.P.D.TYP.TVU.H.U.N.O.UNFIN.UVVCTVENT.VERT.VEST.V.I.F.VIN.V.W.C.Ww/W.C.WD.W.H.WIN.WP.W.R.WSCT.WT.W.V.W.W.F.YDABBREVIATIONS1A101SIM1INTERIOR ELEVATIONDETAILSECTIONDOOR NUMBERWINDOW NUMBERWALL TYPECOLUMN GRIDREVISIONROOM NAME LEVELA1.01TITLEGRAPHIC SYMBOLSA2.11BUILDING ELEVATION11011View Name1/8" = 1'-0"NameElevationA1011SIMMOORHOUSE OFFICE COMPLEXPARCEL# R5262270200PL2431AAACLROOM NAME SITE INFOGENERAL NOTES1. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER REMOVAL TECHNIQUES AND DISPOSAL OF DEBRIS. ANY CLEARING WORK SHALL BE COORDINATED WITH ALL AFFECTED UTILITY COMPANIES AND SHALL CONFORM WITH CITY, COUNTY, AND STATE CODES FOR DISPOSAL OF DEBRIS.2. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING, IDENTIFYING AND PROTECTING ANY UTILITIES THAT ARE TO REMAIN FROM DAMAGE. ANY UTILITY LINES THAT ARE IDENTIFIED BY THE LOCAL UTILITY COMPANIES AS ACCEPTABLE FOR REMOVAL SHALL BE DONE IN ACCORDANCE WITH THE STANDARDS ESTABLISHED BY THE UTILITY COMPANY AFFECTED.3. ALL NEW PLUMBING, GAS, MECHANICAL AND ELECTRICAL SERVICES INTO THE NEW CONSTRUCTION AREAS SHALL BE DONE IN ACCORDANCE WITH ALL STATE AND LOCAL CODES AND ORDNANCES.4. ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO THE PLANS AND CURRENT INTERNATIONAL RESIDENTIAL CODE.5. VERIFY ALL EXISTING CONDITIONS AND CHECK ALL DIMENSIONS AND ELEVATION PRIOR TO STARTING WORK. NOTIFY DESIGNER OF ANY DISCREPANCIES FOUND PRIOR TO PROCEEDING WITH WORK. 6. DIMENSIONS SHOWN DO NOT INCLUDE THE THICKNESS OF ANY APPLIED FINISH MATERIALS. DIMENSIONS ARE EITHER TO FACE OF STUD, FACE OF MASONRY, OR CENTERLINE OF OPENINGS OR STRUCTURE. SHEET INDEX2015 INTERNATIONAL BUILDING CODE (IBC)2015 INTERNATIONAL FIRE CODE (IFC)2012 INTERNATIONAL RESIDENTIAL CODE (IRC)2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) W/ 2012 AMENDMENTS FOR RESIDENTIAL PORTION2012 INTERNATIONAL MECHANICAL CODE (IMC)2012 INTERNATIONAL FUEL & GAS CODE (IFGC)2017 IDAHO STATE PLUMBING CODE (ISPC)2017 NATIONAL ELECTRICAL CODE (NEC)BUILDING CODESOCCUPANCY TYPEBSEISMIC ZONECZONINGL-OBUILDING CONSTRUCTION V-BAREA OF NEW CONSTRUCTION 4,167 MAIN LEVEL OCCUPANT LOAD:41 (1 PER 100)EXITING & EGRESS: 2 REQUIRED; 3 PROVIDEDFIRE SUPPRESSION SYSTEM: NOCHAPTER 29 (TABLE 2902.1)OCCUPANT LOAD: 41 TOTAL (20 MEN/WOMEN)WATER CLOSETS: 1 PER 25 - FIRST 50 / 1 PER 50REQUIRED:1 MEN / 1 WOMENLAVATORIES: 1 PER 40 - FIRST 80 / 1 PER 80REQUIRED:1 MEN / 1 WOMENDRINKING FOUNTAIN: 1 PER 100REQUIRED:NO D.F. REQUIRED (1 A.D.A.)SERVICE SINK REQUIRED:NOSITEPARKING REQUIREMENTS:1 STALL/500 SQFT:4167 SQ FT / 500 = 8 PARKING STALLS1 HANDICAP STALL FOR FIRST 25 STALLS = 1 HANDICAP STALLBICYCLE STALLS = 2 RACKS LOT INFORMATION:LOT SIZE:SEE PLAN SQ FT SETBACKS0' ALL SIDESEASEMENTSSEE PLANPARCEL: R5262270200SHEET NUMBERJOB NO.DRAWNDATECHECKEDARCHITECT STAMPTHIS BAR IS 1 INCHON ORIGINAL DRAWINGIF NOT 1 INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLYVERIFY SCALES01"JESSICA3/10/2020 9:57:34 AM C:\Users\Jessica\Dropbox\_ Work _\12.15 Design\2020\Moorhouse Office Complex\Moorhouse Office Complex_working set.rvtA0.0MOORHOUSE OFFICE COMPLEXLOT 2, BLOCK 1 LINDER PROFESSIONAL PLAZA SUBDIVISION00103.10.2020COVER - COMMERCIAL03.10.202003.10.202011.09.2018SHEET NAMEA0.0 COVER - COMMERCIALA0.1 LANDSCAPE PLANA0.2 SITE PLANA1.0 ENERGY REPORTA1.1 FLOOR PLANA3.1 ELEVATIONSA3.2 ELEVATIONSA3.3 COLOR ELEVATIONS & RENDERINGSA4.1 ROOF PLAN NDRAINSEEPAGE BEDPENNGROVE WAYUTILITY EASEMENT20' - 0"NEW SIDEWALKBUILDING4,167 SQFTPARKING: 1/500 =8 PARKING STALLSLAWNVISION TRIANGLEBICYCLE RACK3' - 10"6' - 0"4' - 10"WHEEL STOPS5' - 0"5' - 0"PLANTER w/ IRRIGATIONIRRIGATIONTREE SYMBOLBOTANICAL NAMECOMMON NAMESIZEWIDTH HEIGHT SPACINGQTY.HONEYLOCUSTAUTUMN BLAZESLOWMOUND MUGO PINEBURNING BUSHDAYLILYGLEDITSIA 'SKYLINE'ACER 'AUTUMN BLAZE'PINUS 'SLOWMOUND'EUONYMUS ALATALAVENDER MOONBEAM3" CAL 9 GAL, CASS 1#2#2#235'30'2'15'18"PLANT SCHEDULEAS SHOWN ON PLANAS SHOWN ON PLANAS SHOWN ON PLANAS SHOWN ON PLANAS SHOWN ON PLANMATURE45'55'3'15'18"716176REINFORCE RUBBERHOSE TREE TIES.DOUBLE #10 GA. GALV.GUYS (3 PER TREE).BURLAP WRAP.3" MULCH.3" SAUCER RIM.FERTILIZER TABLETS.2" x 30" WOOD STAKES.1' - 0"TYPICAL TREE AND SHRUB PLANTING NOTES:1. ALL TREES TO BE BALLED AND BURLAPPED. SEE DETAIL THIS SHEET TREE STAKING.2. 2" MINIMUM OF REGULAR GRIND SOIL AID TO BE PLACED ON SHRUB PLANTING AREAS.3. PROVIDE AND INSTALL (3) 2 x 2 STAKES EVENLY SPACED AT EACH TREE. TIE ALL STAKES WITH COTTON WEBBING OR OTHER APPROVED METHOD.4. PROVIDE AND INSTALL BACKFILL MIX FOR ALL PLANTS. USE 1/2 APPROVED PLANTING MIX AND 1/2 EXISTING SOIL REMOVED FROM PLANTING PITS. DIG ALL PLANT PITS TWICE THE SIZE OF ROOT BALL.5. EXISTING SOIL REMOVED FROM PLANTING PITS. DIG ALL PLANT PITS TWICE THE SIZE OF ROOT BALL.6. FINISH GRADE TOP SOIL TO A UNIFORM AND SMOOTH SURFACE. REMOVE ALL ROCKS AND FOREIGN MATERIAL 1" AND LARGER PRIOR TO LAYING SOD7. PROVIDE AND INSTALL ONE APPLICATION OF APPROVED PLANTING TABLETS FOR ALL PLANTS. PROVIDE AND INSTALL ONE INITIAL APPLICATION OF STARTER FERTILIZER FOR SOD AREAS. ALL FERTILIZERS TO BE APPROVED BY THE OWNER PRIOR TO APPLICATION AND APPLIED AT MANUFACTURERS RECOMMENDED RATE.8. ALL PLANTS AND LAWN SHALL BE GUARANTEED FOR ONE COMPLETE GROWING SEASON AFTER COMPLETION OF CONTRACT AND FINAL ACCEPTANCE.9. NEW LANDSCAPE AREAS TO BE PROVIDED WITH FULLY AUTOMATIC SPRINKLER SYSTEMS.0' - 6"LANDSCAPE PLAN CALCULATIONS:STREET BUFFER: 20; (COLLECTOR)COMMON OPEN SPACE: (4518/18281=) 25%QUALIFIED OPEN SPACE:NUMBER OF TREES PLANTED: 6SHEET NUMBERJOB NO.DRAWNDATECHECKEDARCHITECT STAMPTHIS BAR IS 1 INCHON ORIGINAL DRAWINGIF NOT 1 INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLYVERIFY SCALES01"JESSICA3/10/2020 9:57:35 AM C:\Users\Jessica\Dropbox\_ Work _\12.15 Design\2020\Moorhouse Office Complex\Moorhouse Office Complex_working set.rvtA0.1MOORHOUSE OFFICE COMPLEXLOT 2, BLOCK 1 LINDER PROFESSIONAL PLAZA SUBDIVISION00103.10.2020LANDSCAPE PLAN03.10.202003.10.20201" = 10'-0"1LANDSCAPE PLAN1/4" = 1'-0"2TREE PLANTING IE=64.15 (W)IE=63.47 (S)IE=62.58 (S)IE=61.69 (S)IE=64.15 (W)IE=63.47 (S)IE=62.58 (S)IE=61.69 (S)(S89°59'01"W314.08')(S89°58'24"W167.77')L2L3C1C2C3C4L1L2L3C1C2C3C4NEW HYDRANT3BLOCK133,302SF145,943SF231,676SF418,442SF518,446SF623,140SFROS#10087N90°00'00"E167.69'(46.78')131.62'(124.40')137.19'(129.89')218.13'(225.43')66.94'N48°02'05"E52.90'49.84'50.90'S89°33'33"E100.03'S33°39'48"E44.66'(93.83')S 00°14'43" W404.60'N00°14'51"E422.27'S82°33'10"E100.74'N89°57'53"W48.00'478.08'300.94'S00°00'06"E171.18'66.61'S78°56'46"WS00°14'43"W2634.78'S89°28'30"E2625.59'2324.65'2156.70'N89°59'41"W167.51'N89°59'41"W175.45'(132.12')175.45'N89°57'53"W39.55'178.65'225.95'S00°14'45"W270.47'N90°00'00"E167.51'S00°14'45"W108.11'S00°14'45"W70.45'2573.32302572.9630IRVVP117812392 5 7 6 257625752575257525742574257425742574257425742 57 4 2574257425742573257325732573257325732 5 7 3 2573257325732573 2 5 7 3 25732572257225722572257225722 5 7 2 2571 257125702570N. PENNGROVE WAYMCMILLAN ROADLINDER ROADIR IR IRIR IR IR IR IR IR IR IR IR TH IRSSIRIRIRIRIRIRNEXISTING SHARED TRASH ENCLOSUREPROPOSED BUILDING16' - 6"PROPERTY LINE24' - 0"102' - 6 7/32"EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGFUTURE BUILDINGFUTURE BUILDINGBICYCLE RACKA0.24SimPLANTER w/ IRRIGATIONPLANTER w/ IRRIGATIONSITE PLAN CALCULATIONS:PARKING STALLS (1:500SQFT) = 4,167/500 8 STALLS REQUIRED14 PROVIDED & 1 ADABICYCLE STALLS: (1:25 PARKING STALLS) 1 BICYCLE RACK REQUIRED1 PROVIDEDBUILDING SIZE: 4,167 SQFTLOT SIZE:.419 ACRESSET BACKS:NONEEASEMENTS:SEE PLANR 0' - 5"30" FT'G1' - 0"2" SCH. 40 GALVANIZED STEEL PIPE (2 3/8' O.D.)0' - 3"4" CONC. PAVINGRE: SITE PLAN9' - 0"8'-0" VAN5'-0" STD20' - 0"4" STRIPINGCURB RAMP RE: CIVIL DRAWINGSCURBING RE: CIVIL DRAWINGS60" X 60" ACCESSIBLE SYMBOLA0.25SimACCESSIBLE PARKING ONLY 2' - 0"6'-8".0' - 4"0' - 4"1' - 6"VAN ACCESSIBLE1' - 0"16 GA. GALV. STEEL SIGN PAINTED WITH BLUE REFECTORIES PAINT INCLUDING FASTENERSINTERNATIONAL SYMBOL ACCESSIBILITY AND GRAPHICS PAINTED W/ WHITE REFLECTORIZED PAINT - GRAPHICS AS FOLLOWSRESERVED FOR ACCESSBILE PARKINGVAN ACCESSIBLE2" DIA. STD. WT. GALV. STEEL PIPELINE OF FINISHED1'-0" DIA. CONC. FOOTINGSHEET NUMBERJOB NO.DRAWNDATECHECKEDARCHITECT STAMPTHIS BAR IS 1 INCHON ORIGINAL DRAWINGIF NOT 1 INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLYVERIFY SCALES01"JESSICA3/10/2020 9:57:36 AM C:\Users\Jessica\Dropbox\_ Work _\12.15 Design\2020\Moorhouse Office Complex\Moorhouse Office Complex_working set.rvtA0.2MOORHOUSE OFFICE COMPLEXLOT 2, BLOCK 1 LINDER PROFESSIONAL PLAZA SUBDIVISION00103.10.2020SITE PLAN03.10.202003.10.20201" = 30'-0"1SITE PLAN3/4" = 1'-0"3ACCESSIBLE PARKING1/8" = 1'-0"4ACCESSIBLE PARKING1/2" = 1'-0"5ACCESSIBLE PARKING SIGN 2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)TABLE N1102.1 INSULATION & FENESTRATION REQUIREMENTCLIMATE ZONEFENESTRATIONU-FACTORCEILINGR-VALUEWOOD FRAMEWALL R-VALUEMASS WALLR-VALUEFLOORR-VALUEBASEMENT/CRAWLSPACE R-VALUESLAB R-VALUE& DEPTH50.35R-38R-2113/1730 15/19 R-10; 2FTSHEET NUMBERJOB NO.DRAWNDATECHECKEDARCHITECT STAMPTHIS BAR IS 1 INCHON ORIGINAL DRAWINGIF NOT 1 INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLYVERIFY SCALES01"JESSICA3/10/2020 9:57:36 AM C:\Users\Jessica\Dropbox\_ Work _\12.15 Design\2020\Moorhouse Office Complex\Moorhouse Office Complex_working set.rvtA1.0MOORHOUSE OFFICE COMPLEXLOT 2, BLOCK 1 LINDER PROFESSIONAL PLAZA SUBDIVISION00103.10.2020ENERGY REPORT03.10.202003.10.2020 50' - 0"84' - 0"13' - 9"10' - 3"13' - 0"13' - 0"11' - 6"4' - 9 1/2"4' - 10"3' - 2"1' - 4"6' - 0"4' - 11 1/2"8' - 0"5' - 10"7' - 9 1/2"11' - 3 1/2"4' - 0"10' - 6"10' - 0"4' - 9 1/2"5' - 6"2' - 2 1/2"13' - 5"4' - 8"9' - 5"16' - 3 1/2"12' - 0 1/2"11' - 2"11' - 2"11' - 2"11' - 2"11' - 0"11' - 6"11' - 0"13' - 6 1/2"RECEPTIONOFFICE 1JORDAN'S OFFICESUPERINTENDENT'S OFFICEDREW'S OFFICEDAVE'S OFFICECONFERENCE ROOM10' - 0"4' - 9 1/2"7' - 0"14' - 0"14' - 2 1/2"10' - 0"4' - 9 1/2"7' - 3 1/2"6' - 6 1/2"7' - 2"4' - 9 1/2"9' - 5"14' - 9 1/2"10' - 10 1/2"11' - 2"13' - 2"RECEPTIONOFFICE 2OFFICE 3OFFICE 4OFFICE 5OFFICE 1OFFICE 2OFFICE 3OFFICE 4RECEPTION & WAITINGOFFICE 6OFFICE 1BREAK ROOMMCCARTER-MOORHOUSE1464 SQFTCHIROPRACTOR1466 SQFTACCOUNTANT1109 SQFTCOMMON SPACE128 SQFT11' - 6"4' - 9 1/2"15' - 4"15' - 10 1/2"13' - 5"7' - 9 1/2"4' - 9 1/2"10' - 6"84' - 0"CONFERENCE ROOMBREAK ROOM15' - 0"11' - 0"10' - 6"GLASS WALL6' - 8"CHECK-OUTADMIN6' - 0"5' - 6"11' - 6"11' - 0"11' - 0"11' - 0"11' - 0"11' - 0"6' - 0"SOFFIT12' CEILING12' CEILINGREF.REF.REF.10' CEILING10' CEILING10' CEILING3' - 6"3' - 6"4' - 6"2' - 1"3' - 5"3' - 5"2' - 1"4' - 6"3' - 6"3' - 6"6' - 0"10' - 6"8' - 6"8' - 6"10' - 6"6' - 0"2' - 2"3' - 0"5' -0" x 5' -0"8' -0" H.H.5' -0" x 5' -0"8' -0" H.H.3' -0" x 6' -0"8' -0" H.H.3' -0" x 6' -0"8' -0" H.H.3' -0" x 6' -0"8' -0" H.H.3' -0" x 6' -0"8' -0" H.H.3' -0" x 6' -0"8' -0" H.H.3' -0" x 6' -0"8' -0" H.H.3' -0" x 6' -0"8' -0" H.H.3' -0" x 6' -0"8' -0" H.H.5' -0" x 5' -0"8' -0" H.H.5' -0" x 5' -0"8' -0" H.H.5' -0" x 4' -0"8' -0" H.H.5' -0" x 4' -0"8' -0" H.H.5' -0" x 4' -0"8' -0" H.H.5' -0" x 4' -0"8' -0" H.H.5' -0" x 4' -0"8' -0" H.H.5' -0" x 4' -0"8' -0" H.H.5' -0" x 4' -0"8' -0" H.H.5' -0" x 4' -0"8' -0" H.H.5' -0" x 4' -0"8' -0" H.H.5' -0" x 4' -0"8' -0" H.H.5' -0" x 4' -0"8' -0" H.H.5' -0" x 4' -0"8' -0" H.H.5' -0" x 4' -0"8' -0" H.H.5' -0" x 4' -0"8' -0" H.H.5' -0" x 4' -0"8' -0" H.H.5' -0" x 4' -0"8' -0" H.H.6' - 0"13' - 8"11' - 6"12' - 10"6' - 0"6' - 0"14' - 6"11' - 0"12' - 6"6' - 0"20' - 4"2' - 10"10' - 8"2' - 8"11' - 0"2' - 8"10' - 8"2' - 10"20' - 4"11' - 0"12' CEILING12' CEILING7' - 6"WALL SCONCECAN LIGHTS IN EAVESWALL SCONCECAN LIGHTS IN EAVESSHEET NUMBERJOB NO.DRAWNDATECHECKEDARCHITECT STAMPTHIS BAR IS 1 INCHON ORIGINAL DRAWINGIF NOT 1 INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLYVERIFY SCALES01"JESSICA3/10/2020 9:57:37 AM C:\Users\Jessica\Dropbox\_ Work _\12.15 Design\2020\Moorhouse Office Complex\Moorhouse Office Complex_working set.rvtA1.1MOORHOUSE OFFICE COMPLEXLOT 2, BLOCK 1 LINDER PROFESSIONAL PLAZA SUBDIVISION00103.10.2020FLOOR PLAN03.10.202003.10.20201/4" = 1'-0"11 - MAIN FLOOR MAIN FLOOR0' -0"ROOF PLATE10' -1 1/8"5" / 12"5" / 12"STUCCO:SHERWIN WILLIAMS SW 7551 GREEK VILLASOFFIT AND FACIA:SHERWIN WILLIAMS SW 6990 CAVIARWINDOW & DOOR FRAMES:BLACKSTONE: CREATIVE MINES LUNAR CRAFT SPLIT MODULARMETAL ROOF:BLACKASPHALT SHINGLES:SLATE BLACKSCONCEMAIN FLOOR0' -0"ROOF PLATE10' -1 1/8"STUCCO:SHERWIN WILLIAMS SW 7551 GREEK VILLASOFFIT AND FACIA:SHERWIN WILLIAMS SW 6990 CAVIARWINDOW & DOOR FRAMES:BLACKASPHALT SHINGLES:SLATE BLACKELEVATION NOTES:1. ALL ROOF COVERINGS SHALL CONFORM TO THE IRC, AND SHALL BE INSTALLED PER MANUFACTURER SPECIFICATIONS.2. FLASHING SHALL BE PROVIDED AT ALL EXTERIOR OPENINGS, DECKS. CHIMNEYS, AND ALL ROOF PENETRATIONS PER CODE.3. PROVIDE ATTIC VENTILATION IN ACCORDANCE WITH IRC SECTION 806.2 SPECIFICATIONS.4. 50% OF REQUIRED VENTILATION TO BE PROVIDED 3'-0" ABOVE THE EAVES. THE REMAINDER OF VENTILATION IS TO BE PROVIDED BY SOFFIT VENTS IN THE EAVES.5. PROVIDE ATTIC VENTS ON REAR FACE OF ROOF WHEN POSSIBLE.SHEET NUMBERJOB NO.DRAWNDATECHECKEDARCHITECT STAMPTHIS BAR IS 1 INCHON ORIGINAL DRAWINGIF NOT 1 INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLYVERIFY SCALES01"JESSICA3/10/2020 9:57:38 AM C:\Users\Jessica\Dropbox\_ Work _\12.15 Design\2020\Moorhouse Office Complex\Moorhouse Office Complex_working set.rvtA3.1MOORHOUSE OFFICE COMPLEXLOT 2, BLOCK 1 LINDER PROFESSIONAL PLAZA SUBDIVISION00103.10.2020ELEVATIONS03.10.202003.10.20201/4" = 1'-0"1SOUTH1/4" = 1'-0"2NORTH MAIN FLOOR0' -0"ROOF PLATE10' -1 1/8"STUCCO:SHERWIN WILLIAMS SW 7551 GREEK VILLASOFFIT AND FACIA:SHERWIN WILLIAMS SW 6990 CAVIARWINDOW & DOOR FRAMES:BLACKASPHALT SHINGLES:SLATE BLACKSTONE: CREATIVE MINES LUNAR CRAFT SPLIT MODULARMETAL ROOF:BLACKMAIN FLOOR0' -0"ROOF PLATE10' -1 1/8"STUCCO:SHERWIN WILLIAMS SW 7551 GREEK VILLASOFFIT AND FACIA:SHERWIN WILLIAMS SW 6990 CAVIARWINDOW & DOOR FRAMES:BLACKASPHALT SHINGLES:SLATE BLACKSTONE: CREATIVE MINES LUNAR CRAFT SPLIT MODULARMETAL ROOF:BLACKELEVATION NOTES:1. ALL ROOF COVERINGS SHALL CONFORM TO THE IRC, AND SHALL BE INSTALLED PER MANUFACTURER SPECIFICATIONS.2. FLASHING SHALL BE PROVIDED AT ALL EXTERIOR OPENINGS, DECKS. CHIMNEYS, AND ALL ROOF PENETRATIONS PER CODE.3. PROVIDE ATTIC VENTILATION IN ACCORDANCE WITH IRC SECTION 806.2 SPECIFICATIONS.4. 50% OF REQUIRED VENTILATION TO BE PROVIDED 3'-0" ABOVE THE EAVES. THE REMAINDER OF VENTILATION IS TO BE PROVIDED BY SOFFIT VENTS IN THE EAVES.5. PROVIDE ATTIC VENTS ON REAR FACE OF ROOF WHEN POSSIBLE.SHEET NUMBERJOB NO.DRAWNDATECHECKEDARCHITECT STAMPTHIS BAR IS 1 INCHON ORIGINAL DRAWINGIF NOT 1 INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLYVERIFY SCALES01"JESSICA3/10/2020 9:57:39 AM C:\Users\Jessica\Dropbox\_ Work _\12.15 Design\2020\Moorhouse Office Complex\Moorhouse Office Complex_working set.rvtA3.2MOORHOUSE OFFICE COMPLEXLOT 2, BLOCK 1 LINDER PROFESSIONAL PLAZA SUBDIVISION00103.10.2020ELEVATIONS03.10.202003.10.20201/4" = 1'-0"1EAST1/4" = 1'-0"2WEST ELEVATION NOTES:1. ALL ROOF COVERINGS SHALL CONFORM TO THE IRC, AND SHALL BE INSTALLED PER MANUFACTURER SPECIFICATIONS.2. FLASHING SHALL BE PROVIDED AT ALL EXTERIOR OPENINGS, DECKS. CHIMNEYS, AND ALL ROOF PENETRATIONS PER CODE.3. PROVIDE ATTIC VENTILATION IN ACCORDANCE WITH IRC SECTION 806.2 SPECIFICATIONS.4. 50% OF REQUIRED VENTILATION TO BE PROVIDED 3'-0" ABOVE THE EAVES. THE REMAINDER OF VENTILATION IS TO BE PROVIDED BY SOFFIT VENTS IN THE EAVES.5. PROVIDE ATTIC VENTS ON REAR FACE OF ROOF WHEN POSSIBLE.MAIN FLOOR0' -0"ROOF PLATE10' -1 1/8"5" / 12"5" / 12"STUCCO:SHERWIN WILLIAMS SW 7551 GREEK VILLASOFFIT AND FACIA:SHERWIN WILLIAMS SW 6990 CAVIARWINDOW & DOOR FRAMES:BLACKSTONE: CREATIVE MINES LUNAR CRAFT SPLIT MODULARMETAL ROOF:BLACKASPHALT SHINGLES:SLATE BLACKSCONCESHEET NUMBERJOB NO.DRAWNDATECHECKEDARCHITECT STAMPTHIS BAR IS 1 INCHON ORIGINAL DRAWINGIF NOT 1 INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLYVERIFY SCALES01"JESSICA3/10/2020 9:57:49 AM C:\Users\Jessica\Dropbox\_ Work _\12.15 Design\2020\Moorhouse Office Complex\Moorhouse Office Complex_working set.rvtA3.3MOORHOUSE OFFICE COMPLEXLOT 2, BLOCK 1 LINDER PROFESSIONAL PLAZA SUBDIVISION00103.10.2020COLOR ELEVATIONS & RENDERINGS03.10.202003.10.20201/4" = 1'-0"1SOUTH (color) HVAC UNITS IN ATTIC SPACE5" / 12"5" / 12"5" / 12"5" / 12"5" / 12"5" / 12"5" / 12"5" / 12"5" / 12"SHEET NUMBERJOB NO.DRAWNDATECHECKEDARCHITECT STAMPTHIS BAR IS 1 INCHON ORIGINAL DRAWINGIF NOT 1 INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLYVERIFY SCALES01"JESSICA3/10/2020 9:57:50 AM C:\Users\Jessica\Dropbox\_ Work _\12.15 Design\2020\Moorhouse Office Complex\Moorhouse Office Complex_working set.rvtA4.1MOORHOUSE OFFICE COMPLEXLOT 2, BLOCK 1 LINDER PROFESSIONAL PLAZA SUBDIVISION00103.10.2020ROOF PLAN03.10.202003.10.20201/4" = 1'-0"1ROOF PLAN