Loading...
Landscape PlansR/WR/WR/W R/W R/W R/W R/WIVDDS SDIRRWVIRRR/WR/WR/W R/W R/W R/W R/WIVDDS SDIRRWVIRRVAN 34 2134 21MTRMTRDSDS DS DS DSCOCOEPEPEPEPEP EPDS DSCOCOMW MWMWMWAREA 1AREA 2AREA 3 AREA 12231113TYP. OF 3(2) FA(1) QM(1) CL(1) ZG(1) AA(3) LE(3) CF(3) LACF (1)(1) FA(1) ZG(1) ZG(1) CL(1) QMAA (1)GI (3)GI (3)CK (15)LP (9)JI (5)(10) LM(6) LP(1) PP(6) LM(2) CF(1) PP(2) CF(9) LM(1) PP(2) RG(1) AA(7) SSSS (7)(1) QM(1) ZG(6) RGA.REFER TO LANDSCAPE REQUIREMENTS AND CALCULATIONS, SHEET L1.50.B.CONTRACTOR SHALL REPORT TO LANDSCAPE ARCHITECT ALL CONDITIONS WHICHIMPAIR AND/OR PREVENT THE PROPER EXECUTION OF THIS WORK, PRIOR TOBEGINNING WORK.C.NEW TREE PLANTING, SEE DETAILS 1 & 2/L1.50. CONTRACTOR SHALL STAKE ALLTREES DEEMED NECESSARY, I.E..... FROM BEING BLOWN OVER, PLANTED WITHLOOSE ROOT BALL, ETC. CONTRACTOR'S OPTION.D.NEW SHRUB PLANTING. SEE DETAIL 3 & 4/L1.50.E.ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMANSTANDARDS FOR TYPE AND SIZE SHOWN. PLANTS WILL BE REJECTED IF NOT IN ASOUND AND HEALTHY CONDITION.F.ALL PLANTING BEDS SHALL BE COVERED WITH 3" DEPTH OF MEDIUM GRIND BARKMULCH.G.ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEARBEGINNING AT THE DATE OF ACCEPTANCE BY OWNER. REPLACE ALL PLANTMATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY WITH THESAME SIZE AND SPECIES AT NO COST TO THE OWNER.H.FINISH GRADES TO BE SMOOTH AND EVEN GRADIENTS WITH POSITIVE DRAINAGE INACCORDANCE WITH SITE GRADING PLAN.I.IN ALL PLANTER BED AND LAWN AREAS, THE TOP 6 INCHES OF TOPSOIL WILL BEAMENDED AT A RATIO OF 3 CUBIC YARDS OF COMPOST/ORGANIC MATTER PER 1000SQUARE FEET. ROTO-TILL ORGANIC MATTER A MINIMUM OF 6 INCHES INTOTOPSOIL. ALL TREE PITS SHALL BE A MIX OF SEVEN PARTS TOPSOIL (AS SPECIFIEDIN THESE NOTES) AND THREE PARTS COMPOST/ORGANIC MATTER, BY VOLUME.J.FERTILIZE ALL TREES AND SHRUBS WITH 'AGRIFORM' PLANTING TABLETS.QUANTITY PER MANUFACTURER'S RECOMMENDATIONS.K.ALL PLANTING BEDS SHALL HAVE A MINIMUM OF 18" OF TOPSOIL, SOD AREAS AMINIMUM OF 12" OF TOPSOIL. SPREAD, COMPACT AND FINE GRADE TOPSOIL TO ASMOOTH AND UNIFORM GRADE 3" BELOW SURFACE OF WALKS AND CURBS INPLANTING BED AREAS, AND 1/2" IN LAWN AREAS.L.RE-USE EXISTING SURFACE TOPSOIL WHERE POSSIBLE. VERIFY SUITABILITY OFSURFACE SOIL TO PRODUCE TOPSOIL MEET REQUIREMENTS AND AMEND WHENNECESSARY. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREEOF TOXIC MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS OR OTHERFOREIGN MATERIAL AND A PH OF 5.5 TO 7.0. IF ON-SITE TOPSOIL DOES NOT MEETTHESE MINIMUM STANDARDS, CONTRACTORS ARE RESPONSIBLE TO EITHER: A)PROVIDE APPROVED IMPORTED TOPSOIL, OR B.) IMPROVE ON-SITE TOPSOIL WITHMETHODS APPROVED BY LANDSCAPE ARCHITECT. SUPPLEMENT WITH IMPORTEDTOPSOIL WHEN QUANTITIES ARE INSUFFICIENT. CLEAN TOPSOIL OF ROOTS, PLANTS,SODS, STONES, CLAY LUMPS AND OTHER EXTRANEOUS MATERIALS HARMFUL TOPLANT GROWTH.M.IF IMPORTED TOPSOIL FROM OFF-SITE SOURCES IS REQUIRED, PROVIDE NEWTOPSOIL THAT IS FERTILE, FRIABLE, NATURAL LOAM, SURFACE SOIL, REASONABLYFREE OF SUBSOIL, CLAY LUMPS, BRUSH, WEEDS AND OTHER LITTER, AND FREE OFROOTS, STUMPS, STONES LARGER THAN 2 INCHES IN ANY DIMENSION, AND OTHEREXTRANEOUS OR TOXIC MATTER HARMFUL TO PLANT GROWTH.N.OBTAIN TOPSOIL FROM LOCAL SOURCES OR FROM AREAS HAVING SIMILAR SOILCHARACTERISTICS TO THAT FOUND AT PROJECT SITE. OBTAIN TOPSOIL ONLYFROM NATURALLY, WELL-DRAINED SITES WHERE TOPSOIL OCCURS IN A DEPTH OFNOT LESS THAN 4 INCHES.O.REPRESENTATIVE SAMPLES SHALL BE TESTED FOR ACIDITY, FERTILITY ANDGENERAL TEXTURE BY A RECOGNIZED COMMERCIAL OR GOVERNMENT AGENCY ANDCOPIES OF THE TESTING AGENCY'S FINDINGS AND RECOMMENDATIONS SHALL BEFURNISHED TO THE ARCHITECTS REPRESENTATIVE BY THE CONTRACTOR. NOTOPSOIL SHALL BE DELIVERED IN A FROZEN OR MUDDY CONDITION.ACIDITY/ALKALINITY RANGE - PH. 5.5 TO 7.6.P.IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE CREATEDFROM LANDSCAPE OPERATIONS AND DISPOSE OF PROPERLY OFF SITE.Landscape NotesTURF SOD PERSPECIFICATION SECTION329200.BARK MULCH PERSPECIFICATION SECTION329300.EXISTING TREE,SEE KEYNOTES BELOW.Material Legend:Keynotes:CALLOUT NUMBERS COORDINATEDTO NUMBERED NOTES BELOW.#1.EXISTING STREET TREE TO BE REMOVED. STREET TREES ALONG LINDERUNHEALTHY OR DEAD PER MERIDIAN CITY ARBORIST MEMORANDUM; ALSO ONETREE ON AMERICAN FORK. OTHER STREET TREES TO BE REMOVED ARE 4" CALIPERTHUS EXEMPT FROM MITIGATION REQUIREMENTS.2.SIGHT TRIANGLE PER MERIDIAN CITY CODE 11-3A-3.3.EXISTING STREET TREE TO REMAIN. REFER TO TREE PROTECTION NOTES SHEETC0.00.4.TURF SEED OVER SAND WINDOW. SEE DETAIL 4/L1.50.LANDSCAPE BOULDERSPER SPECIFICATIONSECTION 329300 ANDDETAIL 5/L1.50.3" DEPTH GRAVEL MULCHPER ACHD ROWREQUIREMENTS.TURF SEED PERSPECIFICATION SECTION329200.DRY LAND SEED PERSPECIFICATION SECTION329200.DRAWING NO.:2400 E. Riverwalk DriveBoise, Idaho 83706www.lkvarchitects.com208.336.3443DATE:LKV PROJECT #:1930DRAWN BY:CHECKED BY:BLUE VALLEY ELEMENTARY SCHOOL WEST ADA SCHOOL DISTRICT W. AMERICAN FORK DR. Revisions # Description Date TLG PN: 11919003/31/2020GW/SCDDCZCHorizontal Scale: 020'40'1" = 20'Landscape Plan - Area 1File Location:g:\2019\119190\cad\_cd\119190 cd l100 landscape plan.dwgLast Plotted By:david duperaultDate Plotted:Tuesday, March 31 2020 at 03:43 PM Area 1Landscape PlanL1.01S. SPANISH FORK WAY Sean Conner03/31/2020Sean Conner R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WMBMBMBMBMBIVIVIVDDSSDSDDDDDSWMTRWMTRWMTRWMTRWVWVWVWVWVEVLTR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WMBMBMBMBMBIVIVIVDDSSDSDDDDDSWMTRWMTRWMTRWMTRWVWVWVWVWVEVLTVAN MTRMTRDS DSDSVANVANVAN DS DSCOCOCOMWMWAREA 1AREA 2AREA 4A AREA 2 2211313TYP. OF 313TYP. OF 233TYP. OF 33(1) PFFB (1)(1) CD(1) PFGI (1)SS (6)RG (3)(1) GI(3) SM(3) SS(3) RGCD (1)LP (1)LA (1)SS (3)(1) CD(1) PF(1) CD(1) PFCD (1)(1) CD(6) SS(3) RG(2) CL(1) AA(1) FA(1) ZG(1) QMAA (1)CK (15)LP (9)JI (5)(10) LM(6) LP(1) PP(1) AAAG (1)PF (2)CD (1)(7) SS(1) CI(3) SM(1) RBSS (7)CI (1)SM (3)RB (1)(7) BG(2) CI(1) AGBG (7)CI (2)AG (1)PF (1)(2) CDRG (3)(1) CI(1) LA(3) LMQW (1)PP (1)CF (1)LP (1)(3) RB(3) CI(8) JI(2) LA(6) LM(1) TG(5) RG(3) CF(3) SMSM (6)LP (6)CI (3)RB (1)QW (1)(3) LM(1) LA(1) LP(6) LM(2) LA(1) PP(12) SS(2) CD(3) RG(1) FB(3) LM(1) LA(1) LPSS (6)RG (3)CD (1)SM (3)(1) ZG(6) RGA.REFER TO LANDSCAPE REQUIREMENTS AND CALCULATIONS, SHEET L1.50.B.CONTRACTOR SHALL REPORT TO LANDSCAPE ARCHITECT ALL CONDITIONS WHICHIMPAIR AND/OR PREVENT THE PROPER EXECUTION OF THIS WORK, PRIOR TOBEGINNING WORK.C.NEW TREE PLANTING, SEE DETAILS 1 & 2/L1.50. CONTRACTOR SHALL STAKE ALLTREES DEEMED NECESSARY, I.E..... FROM BEING BLOWN OVER, PLANTED WITHLOOSE ROOT BALL, ETC. CONTRACTOR'S OPTION.D.NEW SHRUB PLANTING. SEE DETAIL 3 & 4/L1.50.E.ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMANSTANDARDS FOR TYPE AND SIZE SHOWN. PLANTS WILL BE REJECTED IF NOT IN ASOUND AND HEALTHY CONDITION.F.ALL PLANTING BEDS SHALL BE COVERED WITH 3" DEPTH OF MEDIUM GRIND BARKMULCH.G.ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEARBEGINNING AT THE DATE OF ACCEPTANCE BY OWNER. REPLACE ALL PLANTMATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY WITH THESAME SIZE AND SPECIES AT NO COST TO THE OWNER.H.FINISH GRADES TO BE SMOOTH AND EVEN GRADIENTS WITH POSITIVE DRAINAGE INACCORDANCE WITH SITE GRADING PLAN.I.IN ALL PLANTER BED AND LAWN AREAS, THE TOP 6 INCHES OF TOPSOIL WILL BEAMENDED AT A RATIO OF 3 CUBIC YARDS OF COMPOST/ORGANIC MATTER PER 1000SQUARE FEET. ROTO-TILL ORGANIC MATTER A MINIMUM OF 6 INCHES INTOTOPSOIL. ALL TREE PITS SHALL BE A MIX OF SEVEN PARTS TOPSOIL (AS SPECIFIEDIN THESE NOTES) AND THREE PARTS COMPOST/ORGANIC MATTER, BY VOLUME.J.FERTILIZE ALL TREES AND SHRUBS WITH 'AGRIFORM' PLANTING TABLETS.QUANTITY PER MANUFACTURER'S RECOMMENDATIONS.K.ALL PLANTING BEDS SHALL HAVE A MINIMUM OF 18" OF TOPSOIL, SOD AREAS AMINIMUM OF 12" OF TOPSOIL. SPREAD, COMPACT AND FINE GRADE TOPSOIL TO ASMOOTH AND UNIFORM GRADE 3" BELOW SURFACE OF WALKS AND CURBS INPLANTING BED AREAS, AND 1/2" IN LAWN AREAS.L.RE-USE EXISTING SURFACE TOPSOIL WHERE POSSIBLE. VERIFY SUITABILITY OFSURFACE SOIL TO PRODUCE TOPSOIL MEET REQUIREMENTS AND AMEND WHENNECESSARY. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREEOF TOXIC MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS OR OTHERFOREIGN MATERIAL AND A PH OF 5.5 TO 7.0. IF ON-SITE TOPSOIL DOES NOT MEETTHESE MINIMUM STANDARDS, CONTRACTORS ARE RESPONSIBLE TO EITHER: A)PROVIDE APPROVED IMPORTED TOPSOIL, OR B.) IMPROVE ON-SITE TOPSOIL WITHMETHODS APPROVED BY LANDSCAPE ARCHITECT. SUPPLEMENT WITH IMPORTEDTOPSOIL WHEN QUANTITIES ARE INSUFFICIENT. CLEAN TOPSOIL OF ROOTS, PLANTS,SODS, STONES, CLAY LUMPS AND OTHER EXTRANEOUS MATERIALS HARMFUL TOPLANT GROWTH.M.IF IMPORTED TOPSOIL FROM OFF-SITE SOURCES IS REQUIRED, PROVIDE NEWTOPSOIL THAT IS FERTILE, FRIABLE, NATURAL LOAM, SURFACE SOIL, REASONABLYFREE OF SUBSOIL, CLAY LUMPS, BRUSH, WEEDS AND OTHER LITTER, AND FREE OFROOTS, STUMPS, STONES LARGER THAN 2 INCHES IN ANY DIMENSION, AND OTHEREXTRANEOUS OR TOXIC MATTER HARMFUL TO PLANT GROWTH.N.OBTAIN TOPSOIL FROM LOCAL SOURCES OR FROM AREAS HAVING SIMILAR SOILCHARACTERISTICS TO THAT FOUND AT PROJECT SITE. OBTAIN TOPSOIL ONLYFROM NATURALLY, WELL-DRAINED SITES WHERE TOPSOIL OCCURS IN A DEPTH OFNOT LESS THAN 4 INCHES.O.REPRESENTATIVE SAMPLES SHALL BE TESTED FOR ACIDITY, FERTILITY ANDGENERAL TEXTURE BY A RECOGNIZED COMMERCIAL OR GOVERNMENT AGENCY ANDCOPIES OF THE TESTING AGENCY'S FINDINGS AND RECOMMENDATIONS SHALL BEFURNISHED TO THE ARCHITECTS REPRESENTATIVE BY THE CONTRACTOR. NOTOPSOIL SHALL BE DELIVERED IN A FROZEN OR MUDDY CONDITION.ACIDITY/ALKALINITY RANGE - PH. 5.5 TO 7.6.P.IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE CREATEDFROM LANDSCAPE OPERATIONS AND DISPOSE OF PROPERLY OFF SITE.Landscape NotesTURF SOD PERSPECIFICATION SECTION329200.BARK MULCH PERSPECIFICATION SECTION329300.EXISTING TREE,SEE KEYNOTES BELOW.Material Legend:Keynotes:CALLOUT NUMBERS COORDINATEDTO NUMBERED NOTES BELOW.#1.EXISTING STREET TREE TO BE REMOVED. STREET TREES ALONG LINDERUNHEALTHY OR DEAD PER MERIDIAN CITY ARBORIST MEMORANDUM; ALSO ONETREE ON AMERICAN FORK. OTHER STREET TREES TO BE REMOVED ARE 4" CALIPERTHUS EXEMPT FROM MITIGATION REQUIREMENTS.2.SIGHT TRIANGLE PER MERIDIAN CITY CODE 11-3A-3.3.EXISTING STREET TREE TO REMAIN. REFER TO TREE PROTECTION NOTES SHEETC0.00.4.TURF SEED OVER SAND WINDOW. SEE DETAIL 4/L1.50.LANDSCAPE BOULDERSPER SPECIFICATIONSECTION 329300 ANDDETAIL 5/L1.50.3" DEPTH GRAVEL MULCHPER ACHD ROWREQUIREMENTS.TURF SEED PERSPECIFICATION SECTION329200.DRY LAND SEED PERSPECIFICATION SECTION329200.DRAWING NO.:2400 E. Riverwalk DriveBoise, Idaho 83706www.lkvarchitects.com208.336.3443DATE:LKV PROJECT #:1930DRAWN BY:CHECKED BY:BLUE VALLEY ELEMENTARY SCHOOL WEST ADA SCHOOL DISTRICT W. AMERICAN FORK DR. Revisions # Description Date TLG PN: 11919003/31/2020GW/SCDDCZCHorizontal Scale: 020'40'1" = 20'Landscape Plan - Area 2File Location:g:\2019\119190\cad\_cd\119190 cd l100 landscape plan.dwgLast Plotted By:david duperaultDate Plotted:Tuesday, March 31 2020 at 03:44 PM Area 2Landscape PlanL1.02S. SPANISH FORK WAY W. AMERICAN FORK DR.S. FARMINGTON A V E Sean Conner03/31/2020Sean Conner R/W R/W R/W R/W R/W IVIVIVIVIVIVIVIVEP EP EP EP EP EP EP EP EP EPEPEP EP EP EP EP EP EPEPEPEPEP EP EPEPEPEPOH P OHPOHPOHPOHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP SIRRIRRIRRTEEMTRGR/W R/W R/W R/W R/W IVIVIVIVIVIVIVIVEP EP EP EP EP EP EP EP EP EPEPEP EP EP EP EP EP EPEPEPEPEP EP EPEPEPEPOH P OHPOHPOHPOHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP SIRRIRRIRRTEEMTRGEP EP EP EP EP EP EP EP EPEPEPEPEPEP EPEPEPEPEPEPEPEPEPEP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EPEPEPEPEPEPEPEPEPEP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP DSDSDSDSDS DSDSDSMWCO AREA 4BAREA 3AREA 4AAREA 3AREA 1 1TYP. OF 51(2) CF(3) LAPF (3)(1) ZG(7) LAAC (3)444A.REFER TO LANDSCAPE REQUIREMENTS AND CALCULATIONS, SHEET L1.50.B.CONTRACTOR SHALL REPORT TO LANDSCAPE ARCHITECT ALL CONDITIONS WHICHIMPAIR AND/OR PREVENT THE PROPER EXECUTION OF THIS WORK, PRIOR TOBEGINNING WORK.C.NEW TREE PLANTING, SEE DETAILS 1 & 2/L1.50. CONTRACTOR SHALL STAKE ALLTREES DEEMED NECESSARY, I.E..... FROM BEING BLOWN OVER, PLANTED WITHLOOSE ROOT BALL, ETC. CONTRACTOR'S OPTION.D.NEW SHRUB PLANTING. SEE DETAIL 3 & 4/L1.50.E.ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMANSTANDARDS FOR TYPE AND SIZE SHOWN. PLANTS WILL BE REJECTED IF NOT IN ASOUND AND HEALTHY CONDITION.F.ALL PLANTING BEDS SHALL BE COVERED WITH 3" DEPTH OF MEDIUM GRIND BARKMULCH.G.ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEARBEGINNING AT THE DATE OF ACCEPTANCE BY OWNER. REPLACE ALL PLANTMATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY WITH THESAME SIZE AND SPECIES AT NO COST TO THE OWNER.H.FINISH GRADES TO BE SMOOTH AND EVEN GRADIENTS WITH POSITIVE DRAINAGE INACCORDANCE WITH SITE GRADING PLAN.I.IN ALL PLANTER BED AND LAWN AREAS, THE TOP 6 INCHES OF TOPSOIL WILL BEAMENDED AT A RATIO OF 3 CUBIC YARDS OF COMPOST/ORGANIC MATTER PER 1000SQUARE FEET. ROTO-TILL ORGANIC MATTER A MINIMUM OF 6 INCHES INTOTOPSOIL. ALL TREE PITS SHALL BE A MIX OF SEVEN PARTS TOPSOIL (AS SPECIFIEDIN THESE NOTES) AND THREE PARTS COMPOST/ORGANIC MATTER, BY VOLUME.J.FERTILIZE ALL TREES AND SHRUBS WITH 'AGRIFORM' PLANTING TABLETS.QUANTITY PER MANUFACTURER'S RECOMMENDATIONS.K.ALL PLANTING BEDS SHALL HAVE A MINIMUM OF 18" OF TOPSOIL, SOD AREAS AMINIMUM OF 12" OF TOPSOIL. SPREAD, COMPACT AND FINE GRADE TOPSOIL TO ASMOOTH AND UNIFORM GRADE 3" BELOW SURFACE OF WALKS AND CURBS INPLANTING BED AREAS, AND 1/2" IN LAWN AREAS.L.RE-USE EXISTING SURFACE TOPSOIL WHERE POSSIBLE. VERIFY SUITABILITY OFSURFACE SOIL TO PRODUCE TOPSOIL MEET REQUIREMENTS AND AMEND WHENNECESSARY. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREEOF TOXIC MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS OR OTHERFOREIGN MATERIAL AND A PH OF 5.5 TO 7.0. IF ON-SITE TOPSOIL DOES NOT MEETTHESE MINIMUM STANDARDS, CONTRACTORS ARE RESPONSIBLE TO EITHER: A)PROVIDE APPROVED IMPORTED TOPSOIL, OR B.) IMPROVE ON-SITE TOPSOIL WITHMETHODS APPROVED BY LANDSCAPE ARCHITECT. SUPPLEMENT WITH IMPORTEDTOPSOIL WHEN QUANTITIES ARE INSUFFICIENT. CLEAN TOPSOIL OF ROOTS, PLANTS,SODS, STONES, CLAY LUMPS AND OTHER EXTRANEOUS MATERIALS HARMFUL TOPLANT GROWTH.M.IF IMPORTED TOPSOIL FROM OFF-SITE SOURCES IS REQUIRED, PROVIDE NEWTOPSOIL THAT IS FERTILE, FRIABLE, NATURAL LOAM, SURFACE SOIL, REASONABLYFREE OF SUBSOIL, CLAY LUMPS, BRUSH, WEEDS AND OTHER LITTER, AND FREE OFROOTS, STUMPS, STONES LARGER THAN 2 INCHES IN ANY DIMENSION, AND OTHEREXTRANEOUS OR TOXIC MATTER HARMFUL TO PLANT GROWTH.N.OBTAIN TOPSOIL FROM LOCAL SOURCES OR FROM AREAS HAVING SIMILAR SOILCHARACTERISTICS TO THAT FOUND AT PROJECT SITE. OBTAIN TOPSOIL ONLYFROM NATURALLY, WELL-DRAINED SITES WHERE TOPSOIL OCCURS IN A DEPTH OFNOT LESS THAN 4 INCHES.O.REPRESENTATIVE SAMPLES SHALL BE TESTED FOR ACIDITY, FERTILITY ANDGENERAL TEXTURE BY A RECOGNIZED COMMERCIAL OR GOVERNMENT AGENCY ANDCOPIES OF THE TESTING AGENCY'S FINDINGS AND RECOMMENDATIONS SHALL BEFURNISHED TO THE ARCHITECTS REPRESENTATIVE BY THE CONTRACTOR. NOTOPSOIL SHALL BE DELIVERED IN A FROZEN OR MUDDY CONDITION.ACIDITY/ALKALINITY RANGE - PH. 5.5 TO 7.6.P.IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE CREATEDFROM LANDSCAPE OPERATIONS AND DISPOSE OF PROPERLY OFF SITE.Landscape NotesTURF SOD PERSPECIFICATION SECTION329200.BARK MULCH PERSPECIFICATION SECTION329300.EXISTING TREE,SEE KEYNOTES BELOW.Material Legend:Keynotes:CALLOUT NUMBERS COORDINATEDTO NUMBERED NOTES BELOW.#1.EXISTING STREET TREE TO BE REMOVED. STREET TREES ALONG LINDERUNHEALTHY OR DEAD PER MERIDIAN CITY ARBORIST MEMORANDUM; ALSO ONETREE ON AMERICAN FORK. OTHER STREET TREES TO BE REMOVED ARE 4" CALIPERTHUS EXEMPT FROM MITIGATION REQUIREMENTS.2.SIGHT TRIANGLE PER MERIDIAN CITY CODE 11-3A-3.3.EXISTING STREET TREE TO REMAIN. REFER TO TREE PROTECTION NOTES SHEETC0.00.4.TURF SEED OVER SAND WINDOW. SEE DETAIL 4/L1.50.LANDSCAPE BOULDERSPER SPECIFICATIONSECTION 329300 ANDDETAIL 5/L1.50.3" DEPTH GRAVEL MULCHPER ACHD ROWREQUIREMENTS.TURF SEED PERSPECIFICATION SECTION329200.DRY LAND SEED PERSPECIFICATION SECTION329200.DRAWING NO.:2400 E. Riverwalk DriveBoise, Idaho 83706www.lkvarchitects.com208.336.3443DATE:LKV PROJECT #:1930DRAWN BY:CHECKED BY:BLUE VALLEY ELEMENTARY SCHOOL WEST ADA SCHOOL DISTRICT W. AMERICAN FORK DR. Revisions # Description Date TLG PN: 11919003/31/2020GW/SCDDCZCHorizontal Scale: 020'40'1" = 20'Landscape Plan - Area 3File Location:g:\2019\119190\cad\_cd\119190 cd l100 landscape plan.dwgLast Plotted By:david duperaultDate Plotted:Tuesday, March 31 2020 at 03:45 PM Area 3Landscape PlanL1.03S. LINDER RDSean Conner03/31/2020Sean Conner R/WR/WIVIVEP OHP OHP OHP OHP OHP OHP OHP SWVWVWVWVTEFOFOR/WR/WIVIVEP OHP OHP OHP OHP OHP OHP OHP SWVWVWVWVTEFOFOEP EP EP EP EPEPEPEPEP EP EP EP EP EPEPEPEP AREA 4BAREA 3AREA 4A213(2) LA(2) CDR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WIVIVIVX X X SDSDWVWVWMTRWMTRER/WR/W VITREOUS CHINAC_LAVATORYKINGSTONK-2005 VITREOUS CHINAC_LAVATORYKINGSTONK-2005 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WIVIVIVX X X SDSDWVWVWMTRWMTRER/WR/WABC D EFGHIJKLMN O P Q R STUVWXYZ12345678910EPEP EP EPEPEPE P E PEPEPE P EP TARGET1261075489325111214151334 21jumprunjumpbalance hopruntip toe34 21VITREOUS CHINAC_LAVATORYKINGSTONK-2005 VITREOUS CHINAC_LAVATORYKINGSTONK-2005 EPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEP EPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPDSDSDSDSDSDSDSDSDSDSCOMWAREA 4BAREA 3AREA 4AAREA 4AAREA 2 221113TYP. OF 23TYP. OF 53(2) CD(2) CD(2) CD(1) GI(6) SM(6) SS(3) RGPF (1)CD (1)(1) LA(1) LP(1) PF(2) CD(1) TG(1) CI(6) SM(2) LP(6) SS(3) RGRG (3)(1) CI(1) LA(3) LMQW (1)PP (1)CF (1)LP (1)44A.REFER TO LANDSCAPE REQUIREMENTS AND CALCULATIONS, SHEET L1.50.B.CONTRACTOR SHALL REPORT TO LANDSCAPE ARCHITECT ALL CONDITIONS WHICHIMPAIR AND/OR PREVENT THE PROPER EXECUTION OF THIS WORK, PRIOR TOBEGINNING WORK.C.NEW TREE PLANTING, SEE DETAILS 1 & 2/L1.50. CONTRACTOR SHALL STAKE ALLTREES DEEMED NECESSARY, I.E..... FROM BEING BLOWN OVER, PLANTED WITHLOOSE ROOT BALL, ETC. CONTRACTOR'S OPTION.D.NEW SHRUB PLANTING. SEE DETAIL 3 & 4/L1.50.E.ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMANSTANDARDS FOR TYPE AND SIZE SHOWN. PLANTS WILL BE REJECTED IF NOT IN ASOUND AND HEALTHY CONDITION.F.ALL PLANTING BEDS SHALL BE COVERED WITH 3" DEPTH OF MEDIUM GRIND BARKMULCH.G.ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEARBEGINNING AT THE DATE OF ACCEPTANCE BY OWNER. REPLACE ALL PLANTMATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY WITH THESAME SIZE AND SPECIES AT NO COST TO THE OWNER.H.FINISH GRADES TO BE SMOOTH AND EVEN GRADIENTS WITH POSITIVE DRAINAGE INACCORDANCE WITH SITE GRADING PLAN.I.IN ALL PLANTER BED AND LAWN AREAS, THE TOP 6 INCHES OF TOPSOIL WILL BEAMENDED AT A RATIO OF 3 CUBIC YARDS OF COMPOST/ORGANIC MATTER PER 1000SQUARE FEET. ROTO-TILL ORGANIC MATTER A MINIMUM OF 6 INCHES INTOTOPSOIL. ALL TREE PITS SHALL BE A MIX OF SEVEN PARTS TOPSOIL (AS SPECIFIEDIN THESE NOTES) AND THREE PARTS COMPOST/ORGANIC MATTER, BY VOLUME.J.FERTILIZE ALL TREES AND SHRUBS WITH 'AGRIFORM' PLANTING TABLETS.QUANTITY PER MANUFACTURER'S RECOMMENDATIONS.K.ALL PLANTING BEDS SHALL HAVE A MINIMUM OF 18" OF TOPSOIL, SOD AREAS AMINIMUM OF 12" OF TOPSOIL. SPREAD, COMPACT AND FINE GRADE TOPSOIL TO ASMOOTH AND UNIFORM GRADE 3" BELOW SURFACE OF WALKS AND CURBS INPLANTING BED AREAS, AND 1/2" IN LAWN AREAS.L.RE-USE EXISTING SURFACE TOPSOIL WHERE POSSIBLE. VERIFY SUITABILITY OFSURFACE SOIL TO PRODUCE TOPSOIL MEET REQUIREMENTS AND AMEND WHENNECESSARY. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREEOF TOXIC MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS OR OTHERFOREIGN MATERIAL AND A PH OF 5.5 TO 7.0. IF ON-SITE TOPSOIL DOES NOT MEETTHESE MINIMUM STANDARDS, CONTRACTORS ARE RESPONSIBLE TO EITHER: A)PROVIDE APPROVED IMPORTED TOPSOIL, OR B.) IMPROVE ON-SITE TOPSOIL WITHMETHODS APPROVED BY LANDSCAPE ARCHITECT. SUPPLEMENT WITH IMPORTEDTOPSOIL WHEN QUANTITIES ARE INSUFFICIENT. CLEAN TOPSOIL OF ROOTS, PLANTS,SODS, STONES, CLAY LUMPS AND OTHER EXTRANEOUS MATERIALS HARMFUL TOPLANT GROWTH.M.IF IMPORTED TOPSOIL FROM OFF-SITE SOURCES IS REQUIRED, PROVIDE NEWTOPSOIL THAT IS FERTILE, FRIABLE, NATURAL LOAM, SURFACE SOIL, REASONABLYFREE OF SUBSOIL, CLAY LUMPS, BRUSH, WEEDS AND OTHER LITTER, AND FREE OFROOTS, STUMPS, STONES LARGER THAN 2 INCHES IN ANY DIMENSION, AND OTHEREXTRANEOUS OR TOXIC MATTER HARMFUL TO PLANT GROWTH.N.OBTAIN TOPSOIL FROM LOCAL SOURCES OR FROM AREAS HAVING SIMILAR SOILCHARACTERISTICS TO THAT FOUND AT PROJECT SITE. OBTAIN TOPSOIL ONLYFROM NATURALLY, WELL-DRAINED SITES WHERE TOPSOIL OCCURS IN A DEPTH OFNOT LESS THAN 4 INCHES.O.REPRESENTATIVE SAMPLES SHALL BE TESTED FOR ACIDITY, FERTILITY ANDGENERAL TEXTURE BY A RECOGNIZED COMMERCIAL OR GOVERNMENT AGENCY ANDCOPIES OF THE TESTING AGENCY'S FINDINGS AND RECOMMENDATIONS SHALL BEFURNISHED TO THE ARCHITECTS REPRESENTATIVE BY THE CONTRACTOR. NOTOPSOIL SHALL BE DELIVERED IN A FROZEN OR MUDDY CONDITION.ACIDITY/ALKALINITY RANGE - PH. 5.5 TO 7.6.P.IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE CREATEDFROM LANDSCAPE OPERATIONS AND DISPOSE OF PROPERLY OFF SITE.Landscape NotesTURF SOD PERSPECIFICATION SECTION329200.BARK MULCH PERSPECIFICATION SECTION329300.EXISTING TREE,SEE KEYNOTES BELOW.Material Legend:Keynotes:CALLOUT NUMBERS COORDINATEDTO NUMBERED NOTES BELOW.#1.EXISTING STREET TREE TO BE REMOVED. STREET TREES ALONG LINDERUNHEALTHY OR DEAD PER MERIDIAN CITY ARBORIST MEMORANDUM; ALSO ONETREE ON AMERICAN FORK. OTHER STREET TREES TO BE REMOVED ARE 4" CALIPERTHUS EXEMPT FROM MITIGATION REQUIREMENTS.2.SIGHT TRIANGLE PER MERIDIAN CITY CODE 11-3A-3.3.EXISTING STREET TREE TO REMAIN. REFER TO TREE PROTECTION NOTES SHEETC0.00.4.TURF SEED OVER SAND WINDOW. SEE DETAIL 4/L1.50.LANDSCAPE BOULDERSPER SPECIFICATIONSECTION 329300 ANDDETAIL 5/L1.50.3" DEPTH GRAVEL MULCHPER ACHD ROWREQUIREMENTS.TURF SEED PERSPECIFICATION SECTION329200.DRY LAND SEED PERSPECIFICATION SECTION329200.DRAWING NO.:2400 E. Riverwalk DriveBoise, Idaho 83706www.lkvarchitects.com208.336.3443DATE:LKV PROJECT #:1930DRAWN BY:CHECKED BY:BLUE VALLEY ELEMENTARY SCHOOL WEST ADA SCHOOL DISTRICT W. AMERICAN FORK DR. Revisions # Description Date TLG PN: 11919003/31/2020GW/SCDDCZCHorizontal Scale: 020'40'1" = 20'Landscape Plan - Area 4AHorizontal Scale: 020'40'1" = 20'Landscape Plan - Area 4BAREA 4B AREA 3AREA 4A File Location:g:\2019\119190\cad\_cd\119190 cd l100 landscape plan.dwgLast Plotted By:david duperaultDate Plotted:Tuesday, March 31 2020 at 03:46 PM Area 4Landscape PlanL1.04W. AMER ICAN FORK DR .W. AMER ICAN FORK DR .S. LINDER RDS. WOODHOUSE AVESean Conner03/31/2020Sean Conner CLASS I TREESBOTANICAL / COMMON NAMESIZECONTAINERQTYACACER PLATANOIDES `CRIMSON SENTRY` / CRIMSON SENTRY MAPLE2" CAL.B&B3AGACER GINNALA `FLAME` / FLAME AMUR MAPLE2" CAL.B&B3CDCERCIS CANADENSIS `JN2` TM / THE RISING SUN EASTERN REDBUD2" CAL.B&B19CFCARPINUS BETULUS `FRANZ FONTAINE` / FRANZ FONTAINE HORNBEAM2" CAL.B&B14CLASS II TREESBOTANICAL / COMMON NAMESIZECONTAINERQTYAAACER X FREEMANII `JEFFSRED` / AUTUMN BLAZE MAPLE2" CAL.B&B4FAFRAXINUS AMERICANA `AUTUMN PURPLE` / AUTUMN PURPLE ASH2" CAL.B&B3FBFRAXINUS PENNSYLVANICA `BERGESON` / BERGESON ASH2" CAL.B&B2GIGLEDITSIA TRIACANTHOS INERMIS `SKYCOLE` TM / SKYLINE THORNLESS HONEY LOCUST2" CAL.B&B9LALIRIODENDRON TULIPIFERA `FASTIGIATUM` / COLUMNAR TULIP POPLAR2" CAL.B&B24QWQUERCUS X WAREI `LONG` TM / REGAL PRINCE OAK2" CAL.B&B2TGTILIA CORDATA `GREENSPIRE` / GREENSPIRE LITTLELEAF LINDEN2" CAL.B&B2CLASS III TREESBOTANICAL / COMMON NAMESIZECONTAINERQTYLELIRIODENDRON TULIPIFERA `EMERALD CITY` TM / EMERALD CITY TULIP TREE2" CAL.B&B3QMQUERCUS MACROCARPA / BURR OAK2" CAL.B&B3ZGZELKOVA SERRATA `GREEN VASE` / SAWLEAF ZELKOVA2" CAL.B&B5EVERGREEN TREESBOTANICAL / COMMON NAMESIZECONTAINERQTYCLCEDRUS LIBANI VAR. STENOCOMA / TURKISH CEDAR7` HT.B&B4PFPINUS FLEXILIS `VANDERWOLF`S PYRAMID` / VANDERWOLF`S PYRAMID PINE6` HT.B&B11SHRUBSBOTANICAL / COMMON NAMESIZECONTAINERQTYBGBUXUS MICROPHYLLA `WINTER GEM` / GLOBE WINTER GEM BOXWOOD2 GAL.14CICORNUS ALBA `IVORY HALO` TM / TATARIAN DOGWOOD3 GAL.14CKCALAMAGROSTIS X ACUTIFLORA `KARL FOERSTER` / FEATHER REED GRASS2 GAL.15JIJUNIPERUS HORIZONTALIS `ICEE BLUE` TM / ICEE BLUE JUNIPER2 GAL.13LMLAVANDULA ANGUSTIFOLIA `MUNSTEAD` / MUNSTEAD ENGLISH LAVENDER1 GAL.46LPLAVANDULA X INTERMEDIA `PHENOMENAL` / LAVENDER2 GAL.28PPPINUS MUGO VAR. `PUMILIO` / MUGO PINE5 GAL.5RBRHUS TYPHINA `BALTIGER` TM / TIGER EYES SUMAC5 GAL.6RGRHUS AROMATICA `GRO-LOW` / GRO-LOW FRAGRANT SUMAC2 GAL.37SMSALVIA X SYLVESTRIS `MAINACHT` / MAY NIGHT SALVIA1 GAL.33SSSCHIZACHYRIUM SCOPARIUM `THE BLUES` / THE BLUES LITTLE BLUESTEM1 GAL.62PLANT SCHEDULELandscape Calculations:NUMBER OF STREET TREES AND LINEAL FEET OF STREETFRONTAGEWIDTH OF LANDSCAPE BUFFERS:LINDER ROADW AMERICAN FORK DRIVES SPANISH FORK LANEACREAGE & PERCENTAGE DEDICATED FOR COMMON OPENSPACENUMBER OF TREES PROVIDED IN PARKING LOT PERIMETERBUFFERWIDTH OF PARKING LOT PERIMETER LANDSCAPE BUFFERNUMBER OF PARKING STALLS AND PERCENT OF PARKINGAREA WITH INTERNAL LANDSCAPINGTOTAL NUMBER OF TREES AND TREE SPECIES MIXMITIGATION FOR REMOVAL OF EXISTING TREES, INCLUDINGNUMBER OF CALIPER INCHES BEING REMOVED60 TREES IN BUFFER (32 IN PLANTING STRIP). 2,056 LF FRONTAGE25-FT MINIMUM20-FT MINIMUM (8 PKWY / 5-FT SIDEWALK)8-FT MINIMUM (PKWY WITH CLASS II)103,124 SF (2.367AC) / 20.6%22 TREES5-FT MIN.175 STALLS8.1% INTERNAL LSCP110 TREES, 16 SPECIES (NOTINCLUDING EXISTING STREETTREES TO BE PRESERVED)SOME EXISTING STREETTREES ARE DEAD OR IN POORHEALTH. PER REVIEW WITHMERIDIAN CITY ARBORIST,DEAD OR DAMAGED EXISTINGSTREET TREES ARE TO BEREPLACED WITH NEW 2"CALIPER TREES, SPECIES TOMATCH ORIGINAL PLAN.LANDSCAPE BUFFERS ALONG STREETS (11-3B-7-3)ONE (1) TREE PER THIRTY-FIVE (35) LINEAR FEET WITH SHRUBS, LAWN, OR OTHER GROUND COVER.STREETTREES REQUIREDTREES PROVIDEDLINDER ROAD (399 LF)11 TREES12 TREESW AMERICAN FORK DRIVE (1,175 LF)34 TREES34 TREES (INCL. 6 EVERGREENS)S SPANISH FORK WAY (482 LF)14 TREES14 TREES (INCL. 2 EVERGREENS)INTERIOR PARKING LOT (11-3B-8-C-2)ONE (1) TREE AND LOW SHRUBS, LAWN, OR OTHER GROUND COVER PER EACH INTERIOR PLANTERTHAT SERVES A SINGLE ROW OF PARKING SPACES.AREA PROVIDEDTREES REQUIREDTREES PROVIDED26 INTERIOR ISLANDS26 TREES27 TREESPERIMETER PARKING LOT LANDSCAPINGONE (1) TREE PER THIRTY-FIVE (35) LINEAR FEET WITH SHRUBS, LAWN, OR OTHER GROUND COVER.PERIMETERTREES REQUIREDTREES PROVIDEDNORTHERN (723 LF)21 TREES22 TREES (INCL. 3 EVERGREENS)EXISTING NATURAL FEATURESTHERE ARE NO EXISTING NATURAL FEATURES (CANALS, WETLANDS, FLOODPLAINS, ETC.) ON THE SITE.PROPOSED FENCINGALL FENCING PROPOSED ON THE SITE IS TO BE BLACK VINYL-COATED CHAIN LINK. HEIGHTS ANDLOCATIONS AS INDICATED ON PLANS.Landscape Requirements:(PER MERIDIAN, ID CITY CODE)DRAWING NO.:2400 E. Riverwalk DriveBoise, Idaho 83706www.lkvarchitects.com208.336.3443DATE:LKV PROJECT #:1930DRAWN BY:CHECKED BY:BLUE VALLEY ELEMENTARY SCHOOL WEST ADA SCHOOL DISTRICT W. AMERICAN FORK DR. Revisions # Description Date TLG PN: 11919003/31/2020GW/SCDDCZCFile Location:g:\2019\119190\cad\_cd\119190 cd l100 landscape plan.dwgLast Plotted By:david duperaultDate Plotted:Tuesday, March 31 2020 at 03:47 PM DetailsLandscape PlanL1.50NOTES:1.THE STAKING OF TREES IS TO BE THE CONTRACTOR'S OPTION; HOWEVER, THE CONTRACTOR ISRESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAINSTRAIGHT FOR A MINIMUM OF 1 YEAR. ALL STAKING SHALL BE REMOVED AT THE END OF THE ONEYEAR WARRANTY PERIOD.2.IN THE EVENT OF A QUESTION OR LACK OF CLARITY ON THE DRAWINGS, THE CONTRACTOR IS TONOTIFY THE LANDSCAPE ARCHITECT BEFORE PROCEEDING.3.LANDSCAPE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT AND OWNER PRIOR TOINSTALLATION OF PLANT MATERIAL.4.WRAP RUBBER CINCH TIES AROUND THE TREE TRUNKS AND STAKES USING EITHER THESTANDARD OR FIGURE EIGHT TYING METHOD. SECURE THE TIES TO THE STAKES WITHGALVANIZED NAILS TO PREVENT SLIPPAGE.5.WATER TREE TWICE WITHIN THE FIRST 24 HOURS.6.IN THE EVENT HARDPAN SOILS PREVENT TREE PLANTING AS DETAILED, NOTIFY THE LANDSCAPEARCHITECT IMMEDIATELY.PREVAILING WIND DIRECTIONREMOVE DEAD/DAMAGED BRANCHES AND PRUNE TOINTERNATIONAL SOCIETY OF ARBORICULTURE STANDARDS;IMPROPERLY PRUNED TREES (AS DETERMINED BY THELANDSCAPE ARCHITECT) SHALL BE REMOVED AND REPLACED.SET ROOTBALL ON NATIVE UNDISTURBED SUBSOILCOMMERCIAL SLOW RELEASE FERTILIZER TABLETSBACKFILL WITH SOIL PLANTING MIX. SEESPECIFICATIONS FOR ADDITIONAL INFORMATION.MULCH LAYER, KEEP MULCH 3" AWAY FROMTRUNK2" x 2" x 8' CEDAR STAKE - DO NOT PENETRATE ROOTBALL.SEE NOTE 1. SET STAKES PARALLEL TO PREVAILING WIND.RUBBER CINCH TIEFINISH GRADEROOT PROBESOIL LINEUTILIZE SOIL/ROOT PROBE AROUND TRUNK(APPROX. 3-4" AWAY FROM TRUNK) TO LOCATEHIGHEST ROOTS. HIGHEST ROOTS SHOULD BEPOSITIONED AT OR SLIGHTLY ABOVE GRADE LEVEL.REMOVE BURLAP, TWINE, AND WIRE BASKET FROM TOP12 OF ROOTBALL, REMOVE ALL NAILS, TIES, AND PLASTICFROM ROOTBALL. IF SYNTHETIC BURLAP IS UTILIZED TOWRAP THE ROOTBALL, IT SHALL BE COMPLETELYREMOVED. ONLY BIODEGRADEABLE BURLAP SHALL BELEFT ON THE BOTTOM OF THE ROOTBALL.2x ROOTBALL DIAMETER3x ROOTBALL DIAMETER6"TREE WRAP TRUNK PROTECTION,REMOVE AFTER INSTALLATION3"1Deciduous Tree PlantingScale: NTSNOTES:1.THE STAKING OF TREES IS TO BE THE CONTRACTOR'S OPTION; HOWEVER, THE CONTRACTOR ISRESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAINSTRAIGHT FOR A MINIMUM OF 1 YEAR. ALL STAKING SHALL BE REMOVED AT THE END OF THE ONEYEAR WARRANTY PERIOD.2.IN THE EVENT OF A QUESTION OR LACK OF CLARITY ON THE DRAWINGS, THE CONTRACTOR IS TONOTIFY THE LANDSCAPE ARCHITECT BEFORE PROCEEDING.3.LANDSCAPE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT AND OWNER PRIOR TOINSTALLATION OF PLANT MATERIAL.4.WRAP RUBBER CINCH TIES AROUND THE TREE TRUNKS AND STAKES USING EITHER THE STANDARD ORFIGURE EIGHT TYING METHOD. SECURE THE TIES TO THE STAKES WITH GALVANIZED NAILS TOPREVENT SLIPPAGE.5.WATER TREE TWICE WITHIN THE FIRST 24 HOURS.6.IN THE EVENT HARDPAN SOILS PREVENT TREE PLANTING AS DETAILED, NOTIFY THE LANDSCAPEARCHITECT IMMEDIATELY.PREVAILING WIND DIRECTIONREMOVE DEAD/DAMAGED BRANCHES AND PRUNE TOINTERNATIONAL SOCIETY OF ARBORICULTURE STANDARDS;IMPROPERLY PRUNED TREES (AS DETERMINED BY THELANDSCAPE ARCHITECT) SHALL BE REMOVED AND REPLACED.SET ROOTBALL ON NATIVE UNDISTURBED SUBSOILCOMMERCIAL SLOW RELEASE FERTILIZER TABLETSBACKFILL WITH SOIL PLANTING MIX. SEESPECIFICATIONS FOR ADDITIONAL INFORMATION.MULCH LAYER, KEEP MULCH 3" AWAY FROMTRUNK2" x 2" x 8' CEDAR STAKE - DO NOT PENETRATE ROOTBALL.SEE NOTE 1. SET STAKES PARALLEL TO PREVAILING WIND.RUBBER CINCH TIEFINISH GRADEROOT PROBESOIL LINEUTILIZE SOIL/ROOT PROBE AROUND TRUNK(APPROX. 3-4" AWAY FROM TRUNK) TO LOCATEHIGHEST ROOTS. HIGHEST ROOTS SHOULD BEPOSITIONED AT OR SLIGHTLY ABOVE GRADE LEVEL.REMOVE BURLAP, TWINE, AND WIRE BASKET FROM TOP12 OF ROOTBALL, REMOVE ALL NAILS, TIES, AND PLASTICFROM ROOTBALL. IF SYNTHETIC BURLAP IS UTILIZED TOWRAP THE ROOTBALL, IT SHALL BE COMPLETELYREMOVED. ONLY BIODEGRADEABLE BURLAP SHALL BELEFT ON THE BOTTOM OF THE ROOTBALL.2x ROOTBALL DIAMETER3x ROOTBALL DIAMETER3"3Coniferous Tree PlantingScale: NTS4" MIN. DEPTH BACKFILL WITH SOIL PLANTINGMIX. SEE SPECIFICATIONS FORADDITIONAL INFORMATION.WATER RETENTION BASIN- SEELANDSCAPE NOTES ON SHEETL0.00.MULCH LAYER 3"DEPTHCOMMERCIALFERTILIZER TABLETS2Shrub PlantingScale: NTSFINISH GRADE5'13'12"SEE DETAIL3/C5.50 6"1.FILTER SAND PER ISPWC 801.2.COMPOST SHALL BE PER SPECIFICATION SECTION 32 92 00.3.BLEND SHALL BE 23 SAND BY 13 COMPOST BY VOLUME.4.SEED PER SPECIFICATION SECTION 32 92 00.NOTES:SAND/COMPOSTBLEND, SEE NOTESTURF SEED PER SPECIFICATIONSECTION 32 92 00.LANDSCAPECIVIL4Drainage Swale with Infiltration WindowScale: NTSSean Conner03/31/2020Sean Conner R/WR/WR/W R/W R/W R/W R/WIVDDS SDIRRWVIRRDNNR/WR/WR/W R/W R/W R/W R/WIVDDS SDIRRWVIRRVAN 34 2134 21MTRMTRDSDS DS DS DSCOCOEPEPEPEPEP EPDS DSCOCOMW MWMWMWAREA 1AREA 2AREA 3 AREA 135T35H35T35H35H35H35H35H35H35H35H35T35H35H35H35H35H35H35T35H35F35H35H35H35H35F35F35F35F35F35F35F35F35F35F35F35F35F35F35F35F35F35F35F35T35F35F35F35F35F35H35H35T35H35F35H35H35F35Q35T35T30Q30HH25Q25H25H25H25H25H25H25H25H25H25H25H25H25T25H25H25H25H25H25H25H25H25H25H25T25H25H25F25F25F25F25F25F25F25F25F25F25F25F25F25F25F25F25F25F35Q35Q35Q35Q35H35H35H35H35Q35H35H35T35T35H35H35QCFS1"34"34"1"34"114"1"34"34"114"34"1"1"114"34"114"112"34"1"114"114"112"112"34"34"1"34"1"34"34"1"1"114"34"1"1"114"114"34"1"1"114"34"1"1"1"34"1"34"1"1"1"34"34"34"34"1"114"34"34"1"114"1"114"114"34"1"114"34"1"114"114"112"114"2"34"34"114"114"112"34"34"114"114"112"34"34"114"114"112"2"34"34"114"114"112"3"3"3"3"114"114"2"114"2"114"114"2"2"2"2"212"2"112"1"34"34"1"1"34"3"3"3"34"1"114"112"2"212"34"1"13"34"112"112"112"112"1"1"114"34"112"34"34"34"114"3"3"1111"345555555122.9112"14344454644.0112"464739.2112"474853.12"485045.5112"504945.5112"495145.5112"515246.8112"522"114"5323.2112"535434.4112"545534.4112"555628.1112"562"2"114"112"5729.4112"5734"1"34"1"34"1"2"112"1"3"IQA.REFER TO IRRIGATION NOTES ON L2.51 FOR MORE INFORMATION.Irrigation Notes:Keynotes:1.IRRIGATION MAINLINE, LATERALS AND VALVES SHOWN IN HARDSCAPE FORGRAPHIC PURPOSES ONLY. CONTRACTOR SHALL INSTALL AT BACK OF CURB INLANDSCAPE BED UNLESS SHOWN IN SLEEVE.2.FIELD LOCATE EXISTING 4" PRESSURE IRRIGATION MAINLINE FOR SOUTHRIDGESUBDIVISION. INSTALL LEEMCO 4x4x3 DUCTILE IRON TEE WITH ISOLATION VALVE ONPROPOSED SCHOOL LEG. WORK MUST BE COMPETED DURING IRRIGATION OFFSEASON. DOWNTIME DURING IRRIGATION SEASON IS NOT ALLOWED.3.IRRIGATION WELL BY SPF ENGINEERS. COORDINATE 4" FLANGE CONNECTION ANDMAINLINE CONTINUATION AS SHOWN ON THESE PLANS.4.INSTALL IRRIGATION CONTROLLER IN A METAL ENCLOSURE IN THIS APPROXIMATELOCATION. IRRIGATION CONTRACTOR SHALL PROVIDE ALL REQUIRED ELECTRICALCONNECTIONS REQUIRED FOR A FULLY OPERATIONAL SYSTEM. CONTRACTOR SHALLCONNECT ALL LOW VOLTAGE AND 120 VOLT POWER WIRES. ALL ABOVE GRADEWIRES SHALL BE LOCATED IN RIGID STEEL CONDUIT. INSTALL AND MAKE ALLNECESSARY CONNECTION TO IQ-NCC-EX ETHERNET CARTRIDGE AT THE ESP-LXDCONTROLLER. CONTRACTOR IS RESPONSIBLE TO SETUP AND DEMONSTRATE IQSYSTEM DURING OWNER TRAINING.5.RETAIN AND PROTECT EXISTING IRRIGATION SYSTEM IN RIGHT-OF-WAY. FIELDADJUST IRRIGATION AS NEEDED TO NEW PROPOSED SITE MODIFICATION TOPROVIDE 100% HEAD-TO-HEAD COVERAGE WITH NO OVERSPRAY ONTO HARDSCAPESURFACES.6.FIELD LOCATE EXISTING 4" PRESSURE IRRIGATION MAINLINE FOR SOUTHRIDGESUBDIVISION IN THIS APPROXIMATE LOCATION. CUT AND LOWER MAINLINE ASREQUIRED FOR NEW SITE MODIFICATIONS. INSTALL NEW WIRE PATH ALONG SIDEMAINLINE, ALL WIRE SPLICE SHALL BE PLACED IN 10" ROUND VALVE BOX.PRESSURE IRRIGATION MAINLINE LOWERING MUST OCCUR DURING IRRIGATION OFFSEASON. REINSTALL PER CITY OF MERIDIAN PRESSURE IRRIGATION STANDARDSAND NAMPA MERIDIAN IRRIGATION DISTRICT.CALLOUT NUMBERS COORDINATEDTO NUMBERED NOTES BELOW.#DRAWING NO.:2400 E. Riverwalk DriveBoise, Idaho 83706www.lkvarchitects.com208.336.3443DATE:LKV PROJECT #:1930DRAWN BY:CHECKED BY:BLUE VALLEY ELEMENTARY SCHOOL WEST ADA SCHOOL DISTRICT W. AMERICAN FORK DR. Revisions # Description Date TLG PN: 11919003/31/2020GW/SCDDCZCHorizontal Scale: 020'40'1" = 20'Irrigation Plan - Area 1File Location:g:\2019\119190\cad\_cd\119190 cd l200 irrigation plan.dwgLast Plotted By:david duperaultDate Plotted:Tuesday, March 31 2020 at 03:50 PM Area 1Irrigation PlanL2.01S. SPANISH FORK WAY Sean Conner03/31/2020Sean Conner R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WMBMBMBMBMBIVIVIVDDSSDSDDDDDSWMTRWMTRWMTRWMTRWVWVWVWVWVEVLTDNNR/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WMBMBMBMBMBIVIVIVDDSSDSDDDDDSWMTRWMTRWMTRWMTRWVWVWVWVWVEVLTVAN MTRMTRDS DSDSVANVANVAN DS DSCOCOCOMWMWAREA 1AREA 2AREA 4A AREA 2 35T35H35H35H35H35T35H35H35F35F35F3535F35F35T35H35T35H35T35H35H35H35H35Q35H35F35H35H35H35H35H35H35F35F35F35F35F35F35F35F35F25Q25Q25H25Q25H25H25H25H25H25H25H25H25H25H25T25H25Q25H25H25H25H25H25H25H25H25H25H25H25Q25H25H25H25H25H25H25H35Q25H25H25H25H25H25H25H35H35H35H35Q35T35T35H35H35T30F30Q30H30Q30H30H35H35H35H35H35T35T35H34"1"34"1"34"1"1"1"1"2"34"114"212"34"1"34"1"34"34"2"1112"34"1"34"114"34"34"1"1"114"34"34"114"34"114"112"34"112"2"34"34"34"2"1"34"34"1"34"114"34"34"114"34"1"34"1"1"1"34"34"34"1"34"34"1"114"34"1"34"34"114"34"112"112"34"1"34"1"34"1"34"1"1"114"114"112"34"1"34"1"114"114"112"112"34"114"34"114"112"34"114"34"114"114"112"2"34"1"34"1"1"34"1"34"1"34"1"114"112"34"1"114"34"1"114"34"34"34"34"114"1"1"34"3"3"3"34"1"114"112"2"34"212"34"114"1"34"114"1"34"1"3"34"3"112"1"1"34"1"34"34"2"112"112"34"1"2"1"112"34"112"34"114"112"34"1"1"112"34"34"34"114"34"34"2"34"34"34"112"112"212"1"114"112"3"5555555553028.0112"303139.4112"313254.82"323"3324.2112"333425.8112"343551.8112"35212"3645.5112"363730.3112"373829.1112"383929.7112"394030.3112"404128.9112"414214.41"423"114"3"4353.42"434424.0112"444521.7112"453"1"3"A.REFER TO IRRIGATION NOTES ON L2.51 FOR MORE INFORMATION.Irrigation Notes:Keynotes:1.IRRIGATION MAINLINE, LATERALS AND VALVES SHOWN IN HARDSCAPE FORGRAPHIC PURPOSES ONLY. CONTRACTOR SHALL INSTALL AT BACK OF CURB INLANDSCAPE BED UNLESS SHOWN IN SLEEVE.2.FIELD LOCATE EXISTING 4" PRESSURE IRRIGATION MAINLINE FOR SOUTHRIDGESUBDIVISION. INSTALL LEEMCO 4x4x3 DUCTILE IRON TEE WITH ISOLATION VALVE ONPROPOSED SCHOOL LEG. WORK MUST BE COMPETED DURING IRRIGATION OFFSEASON. DOWNTIME DURING IRRIGATION SEASON IS NOT ALLOWED.3.IRRIGATION WELL BY SPF ENGINEERS. COORDINATE 4" FLANGE CONNECTION ANDMAINLINE CONTINUATION AS SHOWN ON THESE PLANS.4.INSTALL IRRIGATION CONTROLLER IN A METAL ENCLOSURE IN THIS APPROXIMATELOCATION. IRRIGATION CONTRACTOR SHALL PROVIDE ALL REQUIRED ELECTRICALCONNECTIONS REQUIRED FOR A FULLY OPERATIONAL SYSTEM. CONTRACTOR SHALLCONNECT ALL LOW VOLTAGE AND 120 VOLT POWER WIRES. ALL ABOVE GRADEWIRES SHALL BE LOCATED IN RIGID STEEL CONDUIT. INSTALL AND MAKE ALLNECESSARY CONNECTION TO IQ-NCC-EX ETHERNET CARTRIDGE AT THE ESP-LXDCONTROLLER. CONTRACTOR IS RESPONSIBLE TO SETUP AND DEMONSTRATE IQSYSTEM DURING OWNER TRAINING.5.RETAIN AND PROTECT EXISTING IRRIGATION SYSTEM IN RIGHT-OF-WAY. FIELDADJUST IRRIGATION AS NEEDED TO NEW PROPOSED SITE MODIFICATION TOPROVIDE 100% HEAD-TO-HEAD COVERAGE WITH NO OVERSPRAY ONTO HARDSCAPESURFACES.6.FIELD LOCATE EXISTING 4" PRESSURE IRRIGATION MAINLINE FOR SOUTHRIDGESUBDIVISION IN THIS APPROXIMATE LOCATION. CUT AND LOWER MAINLINE ASREQUIRED FOR NEW SITE MODIFICATIONS. INSTALL NEW WIRE PATH ALONG SIDEMAINLINE, ALL WIRE SPLICE SHALL BE PLACED IN 10" ROUND VALVE BOX.PRESSURE IRRIGATION MAINLINE LOWERING MUST OCCUR DURING IRRIGATION OFFSEASON. REINSTALL PER CITY OF MERIDIAN PRESSURE IRRIGATION STANDARDSAND NAMPA MERIDIAN IRRIGATION DISTRICT.CALLOUT NUMBERS COORDINATEDTO NUMBERED NOTES BELOW.#DRAWING NO.:2400 E. Riverwalk DriveBoise, Idaho 83706www.lkvarchitects.com208.336.3443DATE:LKV PROJECT #:1930DRAWN BY:CHECKED BY:BLUE VALLEY ELEMENTARY SCHOOL WEST ADA SCHOOL DISTRICT W. AMERICAN FORK DR. Revisions # Description Date TLG PN: 11919003/31/2020GW/SCDDCZCHorizontal Scale: 020'40'1" = 20'Irrigation Plan - Area 2File Location:g:\2019\119190\cad\_cd\119190 cd l200 irrigation plan.dwgLast Plotted By:david duperaultDate Plotted:Tuesday, March 31 2020 at 03:51 PM Area 2Irrigation PlanL2.02S. SPANISH FORK WAY W. AMERICAN FORK DR.S. FARMINGTON A V E Sean Conner03/31/2020Sean Conner R/W R/W R/W R/W R/W IVIVIVIVIVIVIVIVEP EP EP EP EP EP EP EP EP EPEPEP EP EP EP EP EP EPEPEPEPEP EP EPEPEPEPOH P OHPOHPOHPOHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP SIRRIRRIRRTEEMTRGR/W R/W R/W R/W R/W IVIVIVIVIVIVIVIVEP EP EP EP EP EP EP EP EP EPEPEP EP EP EP EP EP EPEPEPEPEP EP EPEPEPEPOH P OHPOHPOHPOHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP OHP SIRRIRRIRRTEEMTRGEP EP EP EP EP EP EP EP EPEPEPEPEPEP EPEPEPEPEPEPEPEPEPEP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EPEPEPEPEPEPEPEPEPEP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP EP DSDSDSDSDS DSDSDSMWCO AREA 4BAREA 3AREA 4AAREA 3AREA 1 060612121212121212121212121212121212121212121212121212121212121212121234"1"34"1"1"114"34"1"1"212"34"1"34"34"1"1"34"1"34"1"34"1"34"1"1"1"212"212"1"1"114"34"1"1"114"114"34"212"1"114"114"112"112"1"114"112"2"212"1"112"2"1"34"114"112"2"2"1"112"1"112"2"1"112"1"112"1"112"1"114"112"2"2"1"1"112"2"2"1"112"1"2"1"112"1"3"3"3"34"3"34"212"34"114"2"114"34"114"1"34"2"1"34"114"1"112"34"2"112"34"1"114"112"1"34"212"112"2"2"2"2"112247.41"2328.1112"3454.82"4549.4112"5623.4112"6748.8112"7848.8112"8948.8112"91048.8112"101142.6112"111249.411"1213112"34"1"34"1"1"1"1"112"1"2"4''P IRR 4''P IRR 4''P IRR 4''PIR R 4''PIR R 4''PIR R 4''PIR R 4''PIR R 4''PIR R 4''PIR R 4''PIR R 4''PIR R 6BEGIN663"34"3"A.REFER TO IRRIGATION NOTES ON L2.51 FOR MORE INFORMATION.Irrigation Notes:Keynotes:1.IRRIGATION MAINLINE, LATERALS AND VALVES SHOWN IN HARDSCAPE FORGRAPHIC PURPOSES ONLY. CONTRACTOR SHALL INSTALL AT BACK OF CURB INLANDSCAPE BED UNLESS SHOWN IN SLEEVE.2.FIELD LOCATE EXISTING 4" PRESSURE IRRIGATION MAINLINE FOR SOUTHRIDGESUBDIVISION. INSTALL LEEMCO 4x4x3 DUCTILE IRON TEE WITH ISOLATION VALVE ONPROPOSED SCHOOL LEG. WORK MUST BE COMPETED DURING IRRIGATION OFFSEASON. DOWNTIME DURING IRRIGATION SEASON IS NOT ALLOWED.3.IRRIGATION WELL BY SPF ENGINEERS. COORDINATE 4" FLANGE CONNECTION ANDMAINLINE CONTINUATION AS SHOWN ON THESE PLANS.4.INSTALL IRRIGATION CONTROLLER IN A METAL ENCLOSURE IN THIS APPROXIMATELOCATION. IRRIGATION CONTRACTOR SHALL PROVIDE ALL REQUIRED ELECTRICALCONNECTIONS REQUIRED FOR A FULLY OPERATIONAL SYSTEM. CONTRACTOR SHALLCONNECT ALL LOW VOLTAGE AND 120 VOLT POWER WIRES. ALL ABOVE GRADEWIRES SHALL BE LOCATED IN RIGID STEEL CONDUIT. INSTALL AND MAKE ALLNECESSARY CONNECTION TO IQ-NCC-EX ETHERNET CARTRIDGE AT THE ESP-LXDCONTROLLER. CONTRACTOR IS RESPONSIBLE TO SETUP AND DEMONSTRATE IQSYSTEM DURING OWNER TRAINING.5.RETAIN AND PROTECT EXISTING IRRIGATION SYSTEM IN RIGHT-OF-WAY. FIELDADJUST IRRIGATION AS NEEDED TO NEW PROPOSED SITE MODIFICATION TOPROVIDE 100% HEAD-TO-HEAD COVERAGE WITH NO OVERSPRAY ONTO HARDSCAPESURFACES.6.FIELD LOCATE EXISTING 4" PRESSURE IRRIGATION MAINLINE FOR SOUTHRIDGESUBDIVISION IN THIS APPROXIMATE LOCATION. CUT AND LOWER MAINLINE ASREQUIRED FOR NEW SITE MODIFICATIONS. INSTALL NEW WIRE PATH ALONG SIDEMAINLINE, ALL WIRE SPLICE SHALL BE PLACED IN 10" ROUND VALVE BOX.PRESSURE IRRIGATION MAINLINE LOWERING MUST OCCUR DURING IRRIGATION OFFSEASON. REINSTALL PER CITY OF MERIDIAN PRESSURE IRRIGATION STANDARDSAND NAMPA MERIDIAN IRRIGATION DISTRICT.CALLOUT NUMBERS COORDINATEDTO NUMBERED NOTES BELOW.#DRAWING NO.:2400 E. Riverwalk DriveBoise, Idaho 83706www.lkvarchitects.com208.336.3443DATE:LKV PROJECT #:1930DRAWN BY:CHECKED BY:BLUE VALLEY ELEMENTARY SCHOOL WEST ADA SCHOOL DISTRICT W. AMERICAN FORK DR. Revisions # Description Date TLG PN: 11919003/31/2020GW/SCDDCZCHorizontal Scale: 020'40'1" = 20'Irrigation Plan - Area 3File Location:g:\2019\119190\cad\_cd\119190 cd l200 irrigation plan.dwgLast Plotted By:david duperaultDate Plotted:Tuesday, March 31 2020 at 03:52 PM Area 3Irrigation PlanL2.03S. LINDER RDSean Conner03/31/2020Sean Conner R/WR/WIVIVEP OHP OHP OHP OHP OHP OHP OHP SWVWVWVWVTEFOFOR/WR/WIVIVEP OHP OHP OHP OHP OHP OHP OHP SWVWVWVWVTEFOFOEP EP EP EP EPEPEPEPEP EP EP EP EP EPEPEPEP0612 121"1"114"34"1"1"1"34"1"1"114"112"34"1"54''PIR R 4''PIR R 6ENDR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WIVIVIVX X X SDSDWVWVWMTRWMTRER/WR/W VITREOUS CHINAC_LAVATORYKINGSTONK-2005 VITREOUS CHINAC_LAVATORYKINGSTONK-2005 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W R/W R/W R/W R/W R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WIVIVIVX X X SDSDWVWVWMTRWMTRER/WR/WABC D EFGHIJKLMN O P Q R STUVWXYZ12345678910EPEP EP EPEPEPE P E PEPEPE P EP TARGET1261075489325111214151334 21jumprunjumpbalance hopruntip toe34 21VITREOUS CHINAC_LAVATORYKINGSTONK-2005 VITREOUS CHINAC_LAVATORYKINGSTONK-2005 EPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEP EPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPDSDSDSDSDSDSDSDSDSDSCOMWAREA 4BAREA 3AREA 4AAREA 4AAREA 2 12121212121212121212121212121212121235T35T35Q35H35H35H35H35H35F35H35H35F35F35F35H35H25H25H25Q25H25H25H25H25H25H25H25Q25H35Q25H25H25H25H25H25H25H25H35H35H35H35Q34"34"34"34"1"34"114"114"112"2"212"212"34"1"34"2"2"34"1"1"114"2"2"1"2"1"2"1"2"1"1"112"2"1"1"112"1"112"2"2"1"1"1"112"2"34"1"114"114"34"1"114"112"2"34"34"114"114"112"34"34"114"34"34"114"1"112"112"112"112"114"34"114"1"34"1"1"34"1"34"1"34"34"112"114"34"1"1"34"114"1"34"114"114"114"1"1"34"2"34"34"2"34"34"555551249.4112"121349.0112"131442.6112"141536.6112"151636.6112"161736.6112"171848.8112"181948.8112"192048.8112"202131.2112"212231.7112"222341.1112"232430.3112"242513.91"252615.5112"262740.5112"272825.8112"282929.7112"29112"2"112"15A.REFER TO IRRIGATION NOTES ON L2.51 FOR MORE INFORMATION.Irrigation Notes:Keynotes:1.IRRIGATION MAINLINE, LATERALS AND VALVES SHOWN IN HARDSCAPE FORGRAPHIC PURPOSES ONLY. CONTRACTOR SHALL INSTALL AT BACK OF CURB INLANDSCAPE BED UNLESS SHOWN IN SLEEVE.2.FIELD LOCATE EXISTING 4" PRESSURE IRRIGATION MAINLINE FOR SOUTHRIDGESUBDIVISION. INSTALL LEEMCO 4x4x3 DUCTILE IRON TEE WITH ISOLATION VALVE ONPROPOSED SCHOOL LEG. WORK MUST BE COMPETED DURING IRRIGATION OFFSEASON. DOWNTIME DURING IRRIGATION SEASON IS NOT ALLOWED.3.IRRIGATION WELL BY SPF ENGINEERS. COORDINATE 4" FLANGE CONNECTION ANDMAINLINE CONTINUATION AS SHOWN ON THESE PLANS.4.INSTALL IRRIGATION CONTROLLER IN A METAL ENCLOSURE IN THIS APPROXIMATELOCATION. IRRIGATION CONTRACTOR SHALL PROVIDE ALL REQUIRED ELECTRICALCONNECTIONS REQUIRED FOR A FULLY OPERATIONAL SYSTEM. CONTRACTOR SHALLCONNECT ALL LOW VOLTAGE AND 120 VOLT POWER WIRES. ALL ABOVE GRADEWIRES SHALL BE LOCATED IN RIGID STEEL CONDUIT. INSTALL AND MAKE ALLNECESSARY CONNECTION TO IQ-NCC-EX ETHERNET CARTRIDGE AT THE ESP-LXDCONTROLLER. CONTRACTOR IS RESPONSIBLE TO SETUP AND DEMONSTRATE IQSYSTEM DURING OWNER TRAINING.5.RETAIN AND PROTECT EXISTING IRRIGATION SYSTEM IN RIGHT-OF-WAY. FIELDADJUST IRRIGATION AS NEEDED TO NEW PROPOSED SITE MODIFICATION TOPROVIDE 100% HEAD-TO-HEAD COVERAGE WITH NO OVERSPRAY ONTO HARDSCAPESURFACES.6.FIELD LOCATE EXISTING 4" PRESSURE IRRIGATION MAINLINE FOR SOUTHRIDGESUBDIVISION IN THIS APPROXIMATE LOCATION. CUT AND LOWER MAINLINE ASREQUIRED FOR NEW SITE MODIFICATIONS. INSTALL NEW WIRE PATH ALONG SIDEMAINLINE, ALL WIRE SPLICE SHALL BE PLACED IN 10" ROUND VALVE BOX.PRESSURE IRRIGATION MAINLINE LOWERING MUST OCCUR DURING IRRIGATION OFFSEASON. REINSTALL PER CITY OF MERIDIAN PRESSURE IRRIGATION STANDARDSAND NAMPA MERIDIAN IRRIGATION DISTRICT.CALLOUT NUMBERS COORDINATEDTO NUMBERED NOTES BELOW.#DRAWING NO.:2400 E. Riverwalk DriveBoise, Idaho 83706www.lkvarchitects.com208.336.3443DATE:LKV PROJECT #:1930DRAWN BY:CHECKED BY:BLUE VALLEY ELEMENTARY SCHOOL WEST ADA SCHOOL DISTRICT W. AMERICAN FORK DR. Revisions # Description Date TLG PN: 11919003/31/2020GW/SCDDCZCHorizontal Scale: 020'40'1" = 20'Irrigation Plan - Area 4AHorizontal Scale: 020'40'1" = 20'Irrigation Plan - Area 4BAREA 4B AREA 3AREA 4A File Location:g:\2019\119190\cad\_cd\119190 cd l200 irrigation plan.dwgLast Plotted By:david duperaultDate Plotted:Tuesday, March 31 2020 at 03:53 PM Area 4Irrigation PlanL2.04W. AMER ICAN FORK DR .W. AMER ICAN FORK DR .S. LINDER RDS. WOODHOUSE AVESean Conner03/31/2020Sean Conner SYMBOLMANUFACTURER/MODEL/DESCRIPTIONPSIDETAILRAIN BIRD 1806-U-SAM-PRS U8 SERIESTURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED WIPER SEAL. 1/2"NPT FEMALE THREADED INLET. WITH SEAL-A-MATIC CHECK VALVE, ANDPRESSURE REGULATING.3011/L2.50RAIN BIRD 1806-U-SAM-PRS U10 SERIESTURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED WIPER SEAL. 1/2"NPT FEMALE THREADED INLET. WITH SEAL-A-MATIC CHECK VALVE, ANDPRESSURE REGULATING.3011/L2.50RAIN BIRD 1806-U-SAM-PRS U12 SERIESTURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED WIPER SEAL. 1/2"NPT FEMALE THREADED INLET. WITH SEAL-A-MATIC CHECK VALVE, ANDPRESSURE REGULATING.3011/L2.50RAIN BIRD 1806-U-SAM-PRS U15 SERIESTURF SPRAY 6.0" POP-UP SPRINKLER WITH CO-MOLDED WIPER SEAL. 1/2"NPT FEMALE THREADED INLET. WITH SEAL-A-MATIC CHECK VALVE, ANDPRESSURE REGULATING.3011/L2.50SYMBOLMANUFACTURER/MODEL/DESCRIPTIONPSIGPMDETAILRAIN BIRD 5006-SAM-PC,FC-MPRTURF ROTOR, 6.0" POP-UP, PLASTIC RISER, MATCHED PRECIPITATIONROTOR (MPR NOZZLE). ARC AND RADIUS AS PER SYMBOL. 25 FT=RED, 30FT=GREEN, 35FT=BEIGE. WITH SEAL-A-MATIC CHECK VALVE.451/L2.51RAIN BIRD 5006-SAM-PC,FC-MPRTURF ROTOR, 6.0" POP-UP, PLASTIC RISER, MATCHED PRECIPITATIONROTOR (MPR NOZZLE). ARC AND RADIUS AS PER SYMBOL. 25 FT=RED, 30FT=GREEN, 35FT=BEIGE. WITH SEAL-A-MATIC CHECK VALVE.451/L2.51RAIN BIRD 5006-SAM-PC,FC-MPRTURF ROTOR, 6.0" POP-UP, PLASTIC RISER, MATCHED PRECIPITATIONROTOR (MPR NOZZLE). ARC AND RADIUS AS PER SYMBOL. 25 FT=RED, 30FT=GREEN, 35FT=BEIGE. WITH SEAL-A-MATIC CHECK VALVE.451/L2.51RAIN BIRD F4-PC, FCTURF ROTOR, 4.0" POP-UP, PLASTIC RISER, ADJUSTABLE AND FULLCIRCLE. WITH REMOVABLE SEAL-A-MATIC CHECK VALVE, 1" FEMALETHREADED INLET.606.001/L2.51RAIN BIRD F4-PC, FCTURF ROTOR, 4.0" POP-UP, PLASTIC RISER, ADJUSTABLE AND FULLCIRCLE. WITH REMOVABLE SEAL-A-MATIC CHECK VALVE, 1" FEMALETHREADED INLET.6012.21/L2.51SYMBOLMANUFACTURER/MODEL/DESCRIPTIONDETAILRAIN BIRD PESB1", 1-1/2", 2" PLASTIC INDUSTRIAL VALVES. LOW FLOW OPERATINGCAPABILITY, GLOBE CONFIGURATION. WITH SCRUBBER TECHNOLOGY FORRELIABLE PERFORMANCE IN DIRTY WATER IRRIGATION APPLICATIONS.10/L2.50RAIN BIRD 44-RC1" BRASS QUICK-COUPLING VALVE, WITH CORROSION-RESISTANTSTAINLESS STEEL SPRING, THERMOPLASTIC RUBBER COVER, AND 2-PIECEBODY.4/L2.50MAINLINE ISOLATION VALVE6/L2.50DRAIN VALVE5/L2.50RAIN BIRD ESP-LXD-LXMMSS50 STATION 2WIRE EXT. STAINLESS STEEL CABINET. FLOW SENSING2/L2.51RAIN BIRD IQ-NCC-ENIQ NCC ETHERNET CARTRIDGE UPGRADES ESP-LX SERIES CONTROLLERSTO IQ SATELLITE CONTROLLERS. INCLUDES EMBEDDED ETHERNETNETWORK MODEM WITH RJ-45 PORT, AND PATCH CABLE. REQUIRES LANNETWORK STATIC IP ADDRESS. USED FOR DIRECT OR SERVER SATELLITEAPPLICATIONS.NETAFIM PHOTO DIODE REGISTER 3-8 3"3" TO 8" MASTER VALVE/FLOW SENSOR WITH WATER METER ANDHYDRAULIC VALVE IN A SINGLE UNIT. CAST IRON WITH BAKEDPOWDER-COATED FINISH, MINIMUM WORKING PRESSURE 14 PSI. FLANGECONNECTION, PHOTO DIODE REGISTER, HIGH FREQUENCY.7/L2.50THRUST BLOCK8/L2.50SECONDARY SOURCE WELL CONNECTION/SOUTHRIDGE SUBDIVISION 4" PI LINE1/L2.50IRRIGATION LATERAL LINE: PVC SCHEDULE 40PVC SCH. 40 PIPE SHALL BE USED WITH SOLVENT WELD SCH. 40 FITTINGSFROM 1/2" - 2-1/2" PIPE SIZES. ALL PIPE 3" AND ABOVE SHALL BE CLASS200 WITH DUCTILE JOINT RESTRAIN FITTINGS BY LEEMCO.2/L2.50IRRIGATION MAINLINE: PVC CLASS 200 SDR 21PVC CLASS 200 PIPE SHALL BE USED WITH DUCTILE IRON JOINT RESTRAINFITTINGS BY LEEMCO FOR ALL PIPE SIZED 3" AND LARGER. ALL PIPE 2-1/2"AND BELOW SHALL BE SCH. 40 WITH SOLVENT WELD SCH. 40 FITTINGS.2/L2.50PIPE SLEEVE: PVC CLASS 200 SDR 21PIPE SLEEVE SHALL BE TWICE THE SIZE OF DESIGNED PIPE DIAMETER FORMAINLINE AND 4" FOR LATERAL LINES. INSTALL ADDITIONAL 2" SLEEVE ATALL MAINLINE SLEEVES FOR CONTROL WIRES OR WHERE CONTROL WIRELEAVES MAINLINE ROUTE.3/L2.5025ARC30ARC35ARC0612CIQFSValve NumberValve SizeValve FlowValve Callout###"IRRIGATION SCHEDULEA.PRIMARY WATER SOURCE SHALL UTILIZE SURFACE WATER RIGHT FROMSUBDIVISIONS PRESSURIZED IRRIGATION SOURCE. SYSTEM IS DESIGN BASED ONTHE ASSUMPTION OF THE AVAILABILITY OF 60 G.P.M. AND 80 P.S.I. AT THESOURCE AND 60 P.S.I. AT THE HEADS.B.SECONDARY WATER SOURCE SHALL UTILIZED ON SITE WELL. SECONDARYSOURCE SYSTEM IS DESIGN BASED ON THE ASSUMPTION OF THE AVAILABILITY OF120 G.P.M. AND 80 P.S.I. AT THE SOURCE AND 60 P.S.I. AT THE HEADS.C.CONTRACTOR TO VERIFY LOCATION OF ALL UTILITIES PRIOR TO INITIATION OF ANYDEMOLITION OR CONSTRUCTION OPERATIONS. ANY DAMAGE TO EXISTINGUTILITIES SHALL BE CONTRACTOR'S RESPONSIBILITY.D.COORDINATE ALL IRRIGATION INSTALLATION OPERATIONS WITH CIVIL,MECHANICAL, AND ELECTRICAL ENGINEERING SHEETS.E.CONTRACTOR TO COORDINATE INSTALLATION OF IRRIGATION CONDUIT ANDSLEEVES UNDER HARD SURFACES WITH RESPECTIVE CONTRACTORS.F.ALL SLEEVES TO BE INSTALLED AS PART OF IRRIGATION CONTRACT.APPROXIMATE LOCATION OF SLEEVES ARE SHOWN ON THE IRRIGATION PLAN.FIELD VERIFY LOCATION. ALL ENDS OF SLEEVES TO BE TAPED OR CAPPED ANDMARKED WITH A 2" X 4" PAINTED STAKE EXTENDING TO 24" ABOVE GRADE.STAKES ARE NOT TO BE REMOVED UNTIL THE IRRIGATION SYSTEM IS COMPLETE.ALL SLEEVES SHALL EXTEND A MINIMUM OF 18" BEYOND BACK OF CURB OR EDGEOF PAVEMENT. PROVIDE COMPACTED BACKFILL.G.CONTRACTOR TO OBTAIN AND PAY FOR ALL PERMITS AND FEES REQUIRED FORTHIS WORK.H.IRRIGATION CONTROLLER(S) ARE TO BE LOCATED AS SHOWN ON PLAN.CONTROLLERS SHALL BE WIRED TO POWER SUPPLY BY A LICENSED ELECTRICIANPER LOCAL CODES. IRRIGATION CONTRACTOR TO PROVIDE ALL REQUIREDCONNECTIONS TO 24 VOLT IRRIGATION CONTROL WIRE INSIDE THE BUILDINGSTHROUGH APPROPRIATE SIZED CONDUIT.I.IRRIGATED AREAS CONTAINING VEGETATION WHICH POTENTIALLY MAY IMPEDEPERFORMANCE OF A POP-UP SPRINKLER ARE TO BE REPLACED WITH A 12" HIGHPOP-UP SPRINKLER.J.ALL ELECTRICAL WORK TO MEET OR EXCEED N.E.C., STATE CODES, LOCAL CODES,AND MANUFACTURER'S RECOMMENDATIONS.K.CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL ROCK AND DEBRIS BROUGHTTO THE SURFACE AS A RESULT OF TRENCHING OPERATIONS.L.CONTRACTOR SHALL REFER TO SPECIFICATIONS AND DETAIL DRAWINGS FORADDITIONAL REQUIREMENTS.M.INSTALLATION SHALL COMPLY WITH ALL NATIONAL, STATE, AND LOCAL LAWSAND ORDINANCES.N.IRRIGATION CONTRACTOR SHALL PROVIDE AN AS-BUILT IRRIGATION PLAN UPONCOMPLETION OF INSTALLATION AND PRIOR TO FINAL PAYMENT.O.THE ENTIRE SYSTEM SHALL BE GUARANTEED TO BE COMPLETE AND PERFECT INEVERY DETAIL FOR A PERIOD OF ONE YEAR FROM THE DATE OF ITS ACCEPTANCE;REPAIR OR REPLACEMENT OF ANY DEFECTS OCCURRING WITHIN THAT YEARSHALL BE FREE OF EXPENSE TO THE OWNER.P.AS PART OF THIS CONTRACT, PERFORM AT NO EXTRA COST WINTERIZATION ANDSPRING START UP OF THE SYSTEM DURING THE GUARANTEE PERIOD.Q.ALL MATERIALS SHALL BE NEW AND WITHOUT FLAWS OR DEFECTS OF THEQUALITY AND PERFORMANCE SPECIFIED, AND SHALL MEET THE REQUIREMENTSOF THIS SYSTEM. USE MATERIALS AS SPECIFIED, NO SUBSTITUTIONS SHALL BEPERMITTED WITHOUT PRIOR WRITTEN PERMISSION OF THE OWNER.R.IRRIGATION CONTRACTOR SHALL MAKE NECESSARY MINOR FIELD ADJUSTMENTSTO SPRINKLER NOZZLES, SPRINKLERS, PIPE, AND OTHER IRRIGATION EQUIPMENTLOCATIONS TO FIT THE AS-BUILT SITE. ADJUST HEAD AND PIPE LOCATIONS ASREQUIRED TO AVOID DAMAGING EXISTING TREE ROOTS. ADJUSTMENTS SHALLENSURE HEAD TO HEAD COVERAGE.S.IRRIGATION PIPING LAYOUT IS SCHEMATIC. WHERE LINES ARE SHOWN BELOWPAVEMENT ADJACENT TO LANDSCAPE AREAS, THEY ARE TO BE LOCATED IN THELANDSCAPE AREA UNLESS SHOWN WITH A SLEEVE SYMBOL.T.LOCATION OF EXISTING EQUIPMENT ARE SCHEMATIC IN NATURE. FIELD VERIFYALL BASE AND EXISTING IRRIGATION ELEMENTS AND CONDITIONS PRIOR TOCONSTRUCTION AND PROVIDE NECESSARY ADJUSTMENTS.U.IN THE EVENT OF A DISCREPANCY, IMMEDIATELY NOTIFY THE LANDSCAPEARCHITECT.V.CONTRACTOR SHALL SCHEDULE A MEETING WITH LANDSCAPE ARCHITECT ANDOWNERS REPRESENTATIVE PRIOR TO INSTALLATION OF IRRIGATION CONTROLSYSTEM TO DETERMINE PROCEDURES OF INSTALLATION OF IRRIGATION CONTROLSYSTEM.W.AREAS WHERE FULL CIRCLE HEADS ARE REQUIRED, NON-REVERSING CIRCLEHEADS SHALL BE INSTALLED. PARTIAL CIRCLE HEADS WITH REVERSINGDIRECTION ARE PROHIBITED FOR USE OF 360° ROTATION.X.PIPE VELOCITIES SHALL NOT EXCEED 5 FT/SEC.Y.ALL ABOVE GROUND 120 VOLT AND 24 VOLT WIRE SHALL BE IN PVC CONDUIT.ALL 24 VOLT WIRES SHALL BE TAPED TOGETHER AT TEN FOOT (10'-0") INTERVALS.Z.PROVIDE AND INSTALL GROUNDING ALONG THE TWO WIRE PATH PERMANUFACTURERS RECOMMENDATIONS.U.ALL MAIN LINE FITTINGS SHALL BE LEEMCO DUCTILE IRON PUSH ON TYPE ANDARE TO BE JOINED USING LEEMCO JOINT RESTRAINT SYSTEMS. INSTALL PERMANUFACTURERS RECOMMENDATIONS.V.ALL 24 VOLT POWER WIRES SHALL BE #14 AWG COPPER.Irrigation Notes:A.CONTRACTOR SHALL FIELD LOCATE ALL EXISTING IRRIGATION MAINLINES,LATERALS AND ASSOCIATED COMPONENTS THAT ARE IN NEAR VICINITY OFCONSTRUCTION LIMITS. CONTRACTOR SHALL RETAIN AND PROTECT ALLEXISTING EQUIPMENT AND PIPING THROUGHOUT THE DURATION OFCONSTRUCTION. IF IRRIGATION SYSTEM IS SHUT DOWN DUE TO CONSTRUCTIONPRACTICES, CONTRACTOR SHALL PROVIDE TEMPORARY MEASURES TOENSURE THAT 2" (MIN.) OF WATER IS APPLIED TO ALL LANDSCAPE AREASUNTIL SYSTEM IS CORRECTED.B.CONTRACTOR SHALL ENSURE 100% FUNCTIONALITY OF EXISTING SYSTEMDURING AND AFTER CONSTRUCTION.C.CONTRACTOR SHALL REPLACE/REPAIR ANY DAMAGED EXISTING PIPING ANDCOMPONENTS AT NO COST TO OWNER.Existing Irrigation Retention andPreservation:DRAWING NO.:2400 E. Riverwalk DriveBoise, Idaho 83706www.lkvarchitects.com208.336.3443DATE:LKV PROJECT #:1930DRAWN BY:CHECKED BY:BLUE VALLEY ELEMENTARY SCHOOL WEST ADA SCHOOL DISTRICT W. AMERICAN FORK DR. Revisions # Description Date TLG PN: 11919003/31/2020GW/SCDDCZCFile Location:g:\2019\119190\cad\_cd\119190 cd l200 irrigation plan.dwgLast Plotted By:david duperaultDate Plotted:Tuesday, March 31 2020 at 03:54 PM DetailsIrrigation PlanL2.516" MAX.BACK OF WALKOR CURBFINISH GRADEROTOR POP-UP SPRINKLERPREFABRICATED SWING JOINT,REFER TO TABLE BELOWPVC LATERAL LINEPVC SCH. 40 TEE(SST) OR ELBOW (ST)ROTOR SPRINKLERNTSSCALE:2L2.50SWING JOINTROTOR GPMPRODUCTSIZELENGTH0 - 6RAIN BIRD TSJHUNTER HSJ-034"12" OR 18"6 +RAIN BIRD TSJHUNTER HSJ-11"12" OR 18"1BUILDING WALLAUTOMATIC IRRIGATIONSPRINKLER CONTROLLER2" RIGID STEEL PIPEMIN.2" FROM WALL(1) FOR CONTROL WIRES(1) FOR GROUNDINGWIRESJUNCTION BOX - CAULKBOTH SIDESFINISH GRADE2" RIGID STEEL PIPE ELBOW(12" RADIUS MIN.)DIRECT BURIAL CONTROL ANDCOMMON WIRES TO CONTROLVALVES 18" MIN.BUILDING FOUNDATION5'IRRIGATION CONTROLLER - EXTERIOR WALL MOUNTNTSSCALE:2CHECK VALVE NTSSCALE:CHECK VALVE, CLA-VAL 580 SERIES ORAPPROVED EQUAL. MATCH MAINLINESIZE.LEEMCO FLANGE X BELLADAPTER. MATCH MAINLINE SIZE.FINISH GRADEHEAVY DUTY IRRIGATION BOX.MUST PROVIDE NOTEDCLEARANCES4" ALL SIDES6" DEPTH OF 3/4"CRUSHED PEA GRAVEL(4) BRICKMAINLINE PER PLANS3Sean Conner03/31/2020Sean Conner