Loading...
M5.2_HVAC SchedulesREMARKS: 1. APPROVED ALTERNATE MANUFACTURERS: LENNOX, MITSUBISHI, PANASONIC, LG, CARRIER, OR APPROVED EQUAL BY ENGINEER. 2. PROVIDE MANUFATURERS CRANKCASE HEATER , LOW AMBIENT CONTROLS & (TO 0°F) WIND BAFFLES, REFRIGERATION LINE SET SIZED BY MANUFACTURER, AND TAMPER PROOF PORT CAPS. 3. CONTROL UNIT WITH MANUFACTURER'S WALL MOUNTED THERMOSTAT. 4. PROVIDE WITH MIRO INDUSTRIES HEAVY DUTY MECHANICAL GALVANIZED ROOF SUPPORT WITH ADJUSTABLE SUPPORT LEGS. SUPPORT SHALL EXTEND A MINIMUM OF 6" BEYOND EQUIPMENT IN EACH DIRECTION. BOLT EQUIPMENT TO MECHANICAL SUPPORT. 5. PROVIDE WITH MANUFACTURER'S CONDENSATE PUMP, CONCEAL PUMP BEHIND UNIT WITHIN MOUNTING BRACKET ASSEMBLY. 6. ELECTRICAL TO PROVIDE DISCONNECT. DUCTLESS SPLIT SYSTEM AIR CONDITIONING UNIT SCHEDULE SYMBOL AREA SERVED NOMINAL TONS UNIT TYPE SUPPLY FAN COOLING REQUIRED AT 95°F OSA, 80°F EDB, 62°F EWB ELECTRICAL OUTDOOR UNIT MINIMUM SEER INDOOR/ OUTDOOR OPERATING WEIGHT (LBS) MANUFACTURER AND MODEL REMARKS CFM HP V/Ø TOTAL MBH SENSIBLE MBH MCA MOCP V/Ø FC-101 DATA 2.0 HIGH WALL COOLING ONLY UNIT 715 N/A THROUGH OUTDOOR UNIT 23.0 16.1 18.3 20 208/1 15.0 30 / 100 DAIKIN FAN COIL MODEL FTK24NMVJU CONDENSING UNIT MODEL RK24NMVJU 1 , 2 , 3 , 4 , 5 , 6 CU-101 FC-102 DATA 1.0 HIGH WALL COOLING ONLY UNIT 425 N/A THROUGH OUTDOOR UNIT 13.0 9.5 8.6 15 208/1 15.0 25 / 75 DAIKIN FAN COIL MODEL FTK12NMVJU CONDENSING UNIT MODEL RK12NMVJU 1 , 2 , 3 , 4 , 5 , 6 CU-102 FC-103 DATA 1.0 HIGH WALL COOLING ONLY UNIT 425 N/A THROUGH OUTDOOR UNIT 13.0 9.8 8.6 15 208/1 15.0 25 / 75 DAIKIN FAN COIL MODEL FTK12NMVJU CONDENSING UNIT MODEL RK12NMVJU 1 , 2 , 3 , 4 , 5 , 6 CU-103 FC-104 DATA 1.0 HIGH WALL COOLING ONLY UNIT 425 N/A THROUGH OUTDOOR UNIT 13.0 9.8 8.6 15 208/1 15.0 25 / 75 DAIKIN FAN COIL MODEL FTK12NMVJU CONDENSING UNIT MODEL RK12NMVJU 1 , 2 , 3 , 4 , 5 , 6 CU-104 FC-105 DISH WASH 2.0 HIGH WALL COOLING ONLY UNIT 715 N/A THROUGH OUTDOOR UNIT 23.0 16.1 18.3 20 208/1 15.0 30 / 100 DAIKIN FAN COIL MODEL FTK24NMVJU CONDENSING UNIT MODEL RK24NMVJU 1 , 2 , 3 , 4 , 5 , 6 CU-105 ELECTRIC HEATER SCHEDULE SYMBOL AREA SERVED UNIT TYPE FAN ELECTRICAL MANUFACTURER AND MODEL REMARKS CFM RPM HP KW STEPS V/Ø AMPS EH-101 VESTIBULE CEILING MOUNTED 175 600 1/8 2.0 1 277/1 7.2 MARKEL MODEL 3380 SERIES 1 , 3 EH-102 VESTIBULE CEILING MOUNTED 175 600 1/8 2.0 1 277/1 7.2 MARKEL MODEL 3380 SERIES 1 , 3 EH-103 VESTIBULE CEILING MOUNTED 175 600 1/8 2.0 1 277/1 7.2 MARKEL MODEL 3380 SERIES 1 , 3 EH-104 VESTIBULE CEILING MOUNTED 175 600 1/8 2.0 1 277/1 7.2 MARKEL MODEL 3380 SERIES 1 , 3 EH-105 VESTIBULE CEILING MOUNTED 175 600 1/8 2.0 1 277/1 7.2 MARKEL MODEL 3380 SERIES 1 , 3 EH-106 VESTIBULE CEILING MOUNTED 175 600 1/8 2.0 1 277/1 7.2 MARKEL MODEL 3380 SERIES 1 , 3 EH-107 VESTIBULE CEILING MOUNTED 175 600 1/8 2.0 1 277/1 7.2 MARKEL MODEL 3380 SERIES 1 , 3 EH-108 MECHANICAL ROOM WALL MOUNTED 400 1,400 N/A 5.0 1 277/1 18.1 MARKEL MODEL 5100 SERIES 1 , 4 , 5 EH-109 KITCHEN RESTROOM RECESSED WALL MOUNTED 245 1,400 1/8 2.0 1 277/1 7.2 MARKEL MODEL 3420 SERIES 1 , 2 , 3 EH-110 KITCHEN SURFACE WALL MOUNTED 245 1,400 1/8 2.0 1 277/1 7.2 MARKEL MODEL 3420 SERIES 1 , 2 , 3 EH-111 STAGE STORAGE RECESSED WALL MOUNTED 245 1,400 1/8 2.0 1 277/1 7.2 MARKEL MODEL 3420 SERIES 1 , 2 , 3 EH-112 STAGE STORAGE RECESSED WALL MOUNTED 245 1,400 1/8 2.0 1 277/1 7.2 MARKEL MODEL 3420 SERIES 1 , 2 , 3 EH-113 BOYS RESTROOM CEILING MOUNTED 175 600 1/8 2.0 1 277/1 7.2 MARKEL MODEL 3380 SERIES 1 , 3 EH-114 GIRLS RESTROOM CEILING MOUNTED 175 600 1/8 2.0 1 277/1 7.2 MARKEL MODEL 3380 SERIES 1 , 3 EH-115 RECEPTION TOE-KICK -- -- 1/8 1.0 1 120/1 8.4 MARKEL MODEL TSH SERIES 1 , 6 REMARKS: 1. APPROVED ALTERNATE MANUFACTURERS: BRASCH, QMARK, INDEECO, OUELLET, AND CHROMALOX. 2. MOUNT BOTTOM OF HEATER 18" ABOVE FINISH FLOOR. 3. PROVIDE UNIT WITH AN INTEGRAL THERMOSTAT. THERMOSTAT SHALL BE COVERED WITH A TAMPER-PROOF ACCESS COVER. 4. PROVIDE UNIT WITH A REMOTE WALL MOUNTED LINE-VOLTAGE DDC SENSOR. 5. PROVIDE UNIT WITH WALL MOUNTING BRACKET. MOUNT TOP OF HEATER AT 9'-0" ABOVE FINISHED FLOOR. 6. PROVIDE UNIT WITH REMOTE WALL MOUNTED T-STAT. EXHAUST FAN SCHEDULE SYMBOL AREA SERVED UNIT TYPE BLOWER ELECTRICAL MAXIMUM SONES OPERATING WEIGHT (LBS) MANUFACTURER AND MODEL REMARKS CFM ESP MAXIMUM RPM DRIVE HP/W V/Ø EF-101 KITCHEN RESTROOM CEILING CABINET 75 .375 900 DIRECT 53.0 W 115/1 2.3 13 COOK MODEL GC-124 1 , 2 , 4 EF-102 JANITOR ROOM CEILING CABINET 75 .375 900 DIRECT 53.0 W 115/1 2.3 13 COOK MODEL GC-124 1 , 2 , 4 EF-103 MECH / ELEC ROOM IN-LINE 800 .25 1,139 DIRECT 1/6 HP 115/1 7.4 125 COOK MODEL 120SQN10D 1 , 3 , 5 EF-104 BOYS / GIRLS RESTROOM FAMILY RESTROOM IN-LINE 975 .25 941 DIRECT 1/6 HP 115/1 5.5 150 COOK MODEL 135SQN10D 1 , 3 , 6 EF-105 TOILET ROOM CEILING CABINET 75 .375 900 DIRECT 53.0 W 115/1 2.3 13 COOK MODEL GC-124 1 , 2 , 4 EF-106 JANITOR ROOM CEILING CABINET 150 .375 1,160 DIRECT 57.7 W 115/1 3.5 15 COOK MODEL GC-168 1 , 2 , 4 EF-107 MEN / WOMEN RESTROOM FACULTY IN-LINE 700 .25 1,499 DIRECT 1/6 HP 115/1 6.9 75 COOK MODEL 100SQN12D 1 , 3 , 6 EF-108 TOILET ROOM CEILING CABINET 150 .375 1,160 DIRECT 57.7 W 115/1 3.5 15 COOK MODEL GC-168 1 , 2 , 4 EF-109 TOILET ROOM CEILING CABINET 150 .375 1,160 DIRECT 57.7 W 115/1 3.5 15 COOK MODEL GC-168 1 , 2 , 4 EF-110 BOYS / GIRLS RESTROOM IN-LINE 1,050 .25 984 DIRECT 1/6 HP 115/1 6.3 150 COOK MODEL 135SQN10D 1 , 3 , 6 EF-111 BOYS IN-LINE 450 .25 1,567 DIRECT 1/6 HP 115/1 8.3 50 COOK MODEL 90SQN12D 1 , 3 , 6 EF-112 GIRLS IN-LINE 450 .25 1,567 DIRECT 1/6 HP 115/1 8.3 50 COOK MODEL 90SQN12D 1 , 3 , 6 EF-113 JANITOR ROOM CEILING CABINET 150 .375 1,160 DIRECT 57.7 W 115/1 3.5 15 COOK MODEL GC-168 1 , 2 , 4 REMARKS: 1. APPROVED ALTERNATE MANUFACTURERS: GREENHECK, PENNBARRY, TWIN CITY FAN COMPANY, SOLER & PALAU, ACME, AND BARRY BLOWER. 2. PROVIDE UNIT WITH MANUFACTURER'S STEEL ROOF JACK (SLOPED ROOF) EQUAL TO COOK MODEL RJ (W/ INTEGRAL BIRD SCREEN, FLASHING FLANGE AND BLACK EPOXY FINISH), MANUFACTURER'S WALL CAP EQUAL TO COOK MODEL WCG (W/ INTEGRAL BIRDSCREEN), BACKDRAFT DAMPER, OUTLET FLEX DUCT CONNECTION, STANDARD PLUG DISCONNECT, PRE-WIRED FAN SPEED CONTROLLER, THERMAL OVERLOAD PROTECTION, HANGING VIBRATION ISOLATORS, AND WHITE ALUMINUM GRILLE. 3. PROVIDE UNIT WITH INLET AND OUTLET FLEX DUCT CONNECTIONS, STANDARD PLUG DISCONNECT, PRE-WIRED FAN SPEED CONTROLLER, THERMAL OVERLOAD PROTECTION, AND HANGING VIBRATION ISOLATORS. 4. CONTROL FAN WITH SEPARATE WALL SWITCH. COORDINATE WITH ELECTRICAL. 5. CONTROL FAN WITH HEAT-RISE T-STAT THROUGH THE DDC SYSTEM. 6. CONTROL FAN WITH DDC SYSTEM. KITCHEN EXHAUST FAN SCHEDULE SYMBOL AREA SERVED UNIT TYPE BLOWER ELECTRICAL MAXIMUM SONES OPERATING WEIGHT (LBS) MANUFACTURER AND MODEL REMARKS CFM ESP MAXIMUM RPM DRIVE HP/W V/Ø KEF-101 KITCHEN HOODS (H-101, H-102)ROOF UP-BLAST 3,200 1.05" 1,267 DIRECT 2 HP 208/3 19.6 225 CAPTIVE AIRE MODEL DU180HFA 1 , 2 , 3 , 4 KEF-102 KITCHEN HOOD (H-103)ROOF UP-BLAST 600 0.5" 1,310 DIRECT 1/4 HP 115/1 8.9 75 CAPTIVE AIRE MODEL DU30HFA 1 , 2 , 5 REMARKS: 1. APPROVED ALTERNATE MANUFACTURERS: GREENHECK, PENNBARRY, TWIN CITY FAN COMPANY, SOLER & PALAU, ACME, AND BARRY BLOWER. 2. PROVIDE UNIT WITH MANUFACTURER'S ROOF CURB (VENTED ROOF CURB IF EXHAUST DUCT IS SHAFTED RATHER THAN WRAPPED), THERMAL OVERLOAD PROTECTION (120 VOLT ONLY), PRE-WIRED NEMA 3R ELECTRICAL DISCONNECT SWITCH, HINGED SUB BASE, GREASE TERMINATOR, AND U.L. 762 RATING. 3. PROVIDE WITH PREWIRED WITH VFD. 4. CONTROL FAN WITH KITCHEN HOOD CONTROL PANEL. 5. CONTROL FAN WITH SEPARATE WALL SWITCH. REMARKS: 1. APPROVED ALTERNATE MANUFACTURERS: GREENHECK, E-CON AIR, AND DUO-AIRE. 2. PROVIDE WITH PRE-WIRED REMOTE MOUNTED HOOD CONTROL PANEL (INCLUDING ALL STARTERS, CONTACTORS AND SURFACE-MOUNTED SWITCHES). PROVIDE REMOTE SURFACE-MOUNTED SWITCHES FOR FANS, LIGHTS AND ENERGY MANAGEMENT SYSTEM OVERRIDE. 3. PROVIDE WITH EXHAUST COLLARS AND INTERIOR LIGHTS. 4. PROVIDE HOOD WITH MANUFACTURER'S CHEMICAL FIRE SUPPRESSION SYSTEM INCLUDING MECHANICAL GAS VALVE FOR SHUTDOWN OF MAIN GAS LINE TO COOKING EQUIPMENT. SYSTEM SHALL BE CONNECTED TO BUILDING FIRE ALARM SYSTEM BY FIRE ALARM CONTRACTOR. 5. CONTROL H-101 AND H-102 WITH WALL MOUNTED KITCHEN HOOD CONTROL PANEL. 6. CONTROL H-103 WITH WALL MOUNTED SWITCH. KITCHEN EXHAUST HOOD SCHEDULE SYMBOL TYPE HOOD DIMENSIONS EXHAUST AIR MAKE-UP AIR MANUFACTURER AND MODEL REMARKS LENGTH WIDTH AIRFLOW CFM DUCT CONNECITON MAX S.P. LOSS AIRFLOW CFM DUCT CONNECTION MAX S.P. LOSS H-101 KITCHEN EXHAUST HOOD 8' - 0" 4' - 6" 1,600 12"∅ -0.78" N/A N/A N/A CAPTIVE AIRE MODEL 5424 ND-2-F 1 , 2 , 3 , 4 , 5 H-102 KITCHEN EXHAUST HOOD 8' - 0" 4' - 6" 1,600 12"∅ -0.78" N/A N/A N/A CAPTIVE AIRE MODEL 5424 ND-2-F 1 , 2 , 3 , 4 , 5 H-103 DISHWASHER HOOD 4' - 0" 4' - 0" 600 10"∅ -0.09" N/A N/A N/A CAPTIVE AIRE MODEL 4824 VHB-G 1 , 6 REMARKS: 1. APPROVED ALTERNATE MANUFACTURERS: GREENHECK, AMERICAN WARMING, AIROLITE, SAFE-AIR/DOWCO, LOUVERS & DAMPERS, ARROW UNITED, CESCO, NCA MANUFACTURING, NAILOR, POTTORFF, AND UNITED ENERTECH. 2. COLOR TO BE SELECTED BY ARCHITECT. 3. EXHAUST AND O.S.A. PROVIDE WITH FLANGED FRAME AND BIRD SCREEN, AND 120V/Ø LOW LEAKAGE MOTORIZED DAMPER. INTERLOCK MOTORIZED DAMPER WITH EF-103. LOUVER SCHEDULE SYMBOL SERVICE TYPE NOMINAL SIZE MINIMUM FREE AREA (SQ.FT.)FINISH MANUFACTURER AND MODEL REMARKS L-101 EXHAUST FIXED DRAINABLE 24"X18" 1.33 AAMA 2604 RUSKIN ELF375DX 1 , 2 , 3 L-102 INTAKE FIXED DRAINABLE 24"X18" 1.33 AAMA2604 RUSKIN ELF375DX 1 , 2 , 3 DRAWING NO.: 2400 E. Riverwalk Drive Boise, Idaho 83706 www.lkvarchitects.com 208.336.3443 DATE: LKV PROJECT #: DRAWN BY: CHECKED BY: 18-186 M5.2 HVAC SCHEDULESHVAC SCHEDULESHVAC SCHEDULESHVAC SCHEDULES 03/13/202003/13/202003/13/202003/13/2020 GPBGPBGPBGPB WACWACWACWACBLUE VALLEY ELEMENTARY SCHOOLWEST ADA SCHOOL DISTRICTW. AMERICAN FORK DR.BID SETRevisions# DescriptionDate3/12/2020