Loading...
A3.2_Mechanical Platform PlanAABBEEGGTT779121215151717113QF1616HCC111114142A7.2____________________2A7.2____________________1A7.2____________________1A7.2____________________KRRP101313SSD85MJ4MATCHLINE -AREA BMATCHLINE -AREA EMATCHLINE -AREA DMATCHLINE -AREA AMATCHLINE -AREA BMATCHLINE -AREA AMATCHLINE -AREA DMATCHLINE -AREA DMATCHLINE -AREA E6N3A7.2____________________3A7.2____________________1A7.3____________________1A7.3____________________1A7.4____________________1A7.4____________________22L1A7.5____________________1A7.5____________________2A7.5____________________M100M104A7.65________________A3.141________A3.142________A3.142________A3.142________A3.1422A7.1____________________2A7.1____________________3A7.1____________________3A7.1____________________1A7.1____________________1A7.1____________________2A7.1SIM____________________2A7.1SIM____________________2A7.1SIM____________________2A7.1SIM____________________3A7.1SIM____________________3A7.1SIM____________________M101M102M103M105M106A7.66________A6.712________12' - 6"12' - 6"15' - 0"7.907.907.907.907.907.906S2RW6S2RW6S2RWX12M2X12M2X12M2X12M23A7.1SIM____________________3A7.1SIM____________________AREA 'A'AREA 'B'AREA 'D'AREA 'E'AREA 'C'1.EXTERIOR DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE FOUNDATION WALL / CMU UNLESS NOTED OTHERWISE.2.INTERIOR DIMENSIONS ARE TO FACE OF STUD UNLESS NOTED OTHERWISE.3.SEE SHEET A1.1 FOR CODE COMPLIANCE FLOOR PLAN AND BUILDING CODE COMPLIANCE SUMMARY.4.SEE SHEET A3.8 FOR TYPICAL CLASSROOMS AND INTERIOR ELEVATIONS.5.SEE SHEET A4.1 FOR ROOM FINISH SCHEDULE.6.SEE SHEET A4.2 / A4.3 FOR DOOR SCHEDULE AND DOOR AND WINDOW FRAME TYPES.7.FURNISH AND INSTALL INTERIOR SIGNS AT ALL INTERIOR DOORS AND AT OTHER LOCATIONS UP TO SPECIFIED LIMITS. SEE SHEET A3.16 -SIGNAGE FLOOR PLAN AND SPECIFICATIONS.8.FURNISH AND INSTALL WINDOW BLINDS. SEE SHEET A4.2, A4.3, AND SPECIFICATIONS.9.SEE SHEET A1.2 FOR SPECIALTY ITEM MOUNTING HEIGHTS AND INTERIOR SIGNAGE MOUNTING HEIGHTS.10.ALL FRAMES TO HAVE 4" STUD FRAME RETURN AT ALL DOORS AND WINDOW JAMBS UNLESS NOTED OTHERWISE.11. AT WOOD TRUSS LOCATIONS. RUN INTERIOR WALLS FULL HEIGHT TO UNDER SIDE OF WOOD TRUSSES. CONTINUE GYPSUM BOARD ALONG UNDERSIDE OF TRUSS, TYP UNLESS NOTED OTHERWISE.12ABUSE RESISTANT GYPSUM BOARD UP TO 4' -0" AT ALL HALLWAYS, COORIDORS, ALCOVES, AND VESTIBULES. ABUSE RESISTANCE GYPSUM BOARD FULL HEIGHT IN RESTROOMS.13.SEE SPECIFICATIONS FOR CONTROL JOINTS AT GYPSUM WALL BOARD AND CEILINGS UNLESS NOTED OTHERWISE ON DRAWINGS.14. SEE SHEET A3.15 -WALL COVERING PLAN FOR WALL COVERING @ COORIDORS AND CAFETERIA.MECHANICAL PLATFORM:2x4 PLATFORM GUARDRAIL AND TOE KICK TO BE CONTINUOUS ALONG ENTIRE PERIMETER OF PLATFORM. SEE DETAIL 4/A3.15 FOR GUARDRAIL CONSTRUCTION. PLATFORM ELEVATION. COORDINATE WITH STRUCTURAL DRAWINGS.X -XFIRE RETARDANT TREATED ROOFSHEATHING REQUIRED 4'-0" MINIMUM ON EACH SIDE OF FIRE WALL (HATCHED AREA). NO OPENINGS IN ROOF PERMITTED WITHIN 4'-0" OF EITHER SIDE OF WALLDRAWING NO.:2400 E. Riverwalk DriveBoise, Idaho 83706www.lkvarchitects.com208.336.3443DATE:LKV PROJECT #:DRAWN BY:CHECKED BY:AR-2396AMBERIS TETALCNESECHOFOIADVAN OCKERTTERADIHC 3/13/20A3.2MECHANICAL PLATFORM03/13/20201930AS/TNAVO/TNBLUE VALLEY ELEMENTARY SCHOOLWEST ADA SCHOOL DISTRICTW. AMERICAN FORK DR.BID SET1" = 20'-0"1MECHANICAL PLATFORMGeneral NotesReference NotesKeyed Notes7.90 SEE 6 SERIES FOR ROOF PLANS.Key PlanNORTHLegendRevisions# DescriptionDate