Loading...
180364 Design Review Application - Inglewood Place Subdivision - Residential (3) Planning Division DESIGN REVIEW ■ Application Checklist Community Development  Planning Division  33 E. Broadway Avenue, Ste. 102 Meridian, Idaho 83642 Phone: 208-884-5533 Fax: 208-888-6854 www.meridiancity.org (Rev. 7/25/2017) All applications are required to contain one copy of the following: Applicant (√) Description Staff (√) Completed and signed Development Review Application (If also submitting a concurrent application for Certificate of Zoning Compliance, design review will be processed along with that application. Therefore, a Development Review Application is not necessary in this case; just check the Design Review box on the Development Review Application and submit the information below.) Completed Architectural Standards Compliance Checklist (Indicate compliance with all applicable standards to include Commercial, Traditional Neighborhood or Multi-family Districts, under Non-residential or Residential categories.) Provide in a narrative letter, how the proposal addresses standards contained in the City of Meridian Architectural Standards Manual and the Unified Development Code (UDC): 1. Architectural Character: a. Cohesive Design b. Building Scale c. Building Form d. Architectural Elements e. Materials f. Signs and/or Lighting 2. Parking Lots 3. Pedestrian walkways and facilities A complete set of scaled plans including building elevations, with building materials, colors and textures, mechanical equipment, and site plans with landscaping. Reductions of the elevations (8 ½” x 11”) and electronic copies in PDF format Fee All requests for design review approval must meet the procedures set forth in UDC 11-5 and the criteria set forth in the “City of Meridian Architectural Standards Manual”, as applicable. APPLICATIONS WILL NOT BE ACCEPTED, OR MAY BE RETURNED, IF ALL APPLICABLE ITEMS ON THE CHECKLIST ARE NOT SUBMITTED. Project name: Concurrent File #: Applicant/agent: »Last Modified: 02/12/2016. Questions? Contact the Planning Division at 208.884.5533 or www.meridiancity.org Architectural Standards D esign R eview C heC klist | R esi D ential Page | 1 Cohesive Design, ResiDential stanDaRDs (CDRs) Y N N/A ID #Description Comments Staff Intent R1.00 Promote visually aesthetic building designs that incorporate quality architectural characteristics and establish built environments that are compatible with existing, planned, and anticipated adjacent land uses. Goal R1.10 Articulate building designs to frame and accentuate public spaces with pedestrian scale elements and details. R1.1A Maintain consistent and contiguous pedestrian environments across developments. Limit circuitous connections and maintain clear visibility. R1.1B Provide pedestrian connections to public spaces. R1.1C Buildings must orient, frame, and/or direct pedestrian views to adjacent cultural buildings, parks, and plazas. R1.1D Design and orient buildings not to impede access. The build- ing should enhance the appeal of open space and pedestrian environments R1.1E Incorporate architectural features on all sides of a building façade facing: the primary entrance(s) of an adjacent building, public roadways, interior site amenities, and façades that are visible from public spaces. See Architectural Elements, Building Form, and Materials sections. Goal R1.20 Within multi-family developments, enhance wayfinding and create a unique identity for each building, by incorporating complimentary variation in design. R1.2A Ensure that no two buildings viewed from a public street or public space are alike, by varying at least two of the following for each building: roof pitches, material types, color packages, structure orientation, or incorporate other unique and identifiable architectural or landscape element (such as art). Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †RESIDENTIAL STANDARDS | MULTI-FAMILY †PROJECT INFORMATION Project Name: Applicant/Agent: File # OFFICIAL USEDate: »Last Modified: 02/12/2016. Questions? Contact the Planning Division at 208.884.5533 or www.meridiancity.org Architectural Standards D esign R eview C heC klist | R esi D ential Page | 2 BuilDing FoRm, ResiDential stanDaRDs (BFRs) Y N N/A ID #Description Comments Staff Intent R3.00 Emphasize architectural building forms that support compatible building scales, provide appealing architectural character, and contribute to the quality of the neighborhood. Goal R3.10 Articulate building forms, including, but not limited to, massing, walls, and roofs, with appropriately scaled modulations that contribute to the development of visually aesthetic and well articulated building designs. Applies to building façades visible from a public street or public spaces. R3.1A Provide a complementary and proportionate level of design and detail on all public oriented façades. R3.1B Incorporate at least one type of modulation in the façade plane, including, but not limited to: projections, recesses, and step backs that articulate wall planes and break up building mass. R3.1C For applicable façades equal to or longer than 20-feet, provide a minimum total modulation area of 20% the horizontal wall span, with a minimum vertical height of at least 3-feet. Porches and balconies may count toward this. R3.1D Modulation for qualifying projections, pop outs, bays, recesses, and varied setbacks, must be a minimum depth of 1-foot from the primary façade plane. A minimum 50% of total modulation must be visible over permanent barriers, such as berms and fencing, from described areas. R3.1E Use any combination of material type, color variation, banding, stringcourse, or modulation to clearly distinguish between the ground level and upper stories. R3.1F Incorporate visually heavier and more massive elements or materials, such as stone or masonry, primarily at the base of buildings, and lighter elements and materials such as siding, above. This excludes columns, supports, modulated walls, architectural features, and roof elements. Goal R3.20 Residential designs should articulate façades into smaller components and break up monotonous wall planes by integrating horizontal and vertical elements. R3.2A Use any combination of material, color, modulation, or other articulation to delineate and break up wall planes greater than 20-feet by 10-feet or wall planes exceeding 200 total square feet (whichever is more stringent). Applies to public oriented building façades visible from a public street or public spaces. R3.2B Second-story residential façades may not extend to the front face of garage bays without additional façade modulation or additional material types and architectural accents. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †MULTI-FAMILY | CONTINUED »Last Modified: 02/12/2016. Questions? Contact the Planning Division at 208.884.5533 or www.meridiancity.org Architectural Standards D esign R eview C heC klist | R esi D ential Page | 3 BuilDing FoRm, ResiDential stanDaRDs (BFRs) Y N N/A ID #Description Comments Staff R3.2C Building façades and structures, including detached garages and carports, with a projection depth towards the front property line of more than 30% the primary façade width are not allowed. R3.2D Residential buildings with attached units must articulate the design to differentiate façades of individual units or groups of units. Must consistently incorporate any two of the following: modulation, material, or color variation. Goal R3.30 Design accessory structures to be compatible with residential build - ings. Accessory structures include, but are not limited to, sheltered mailboxes, storage areas, maintenance and recreational facilities, detached garages and carports, and secondary dwellings. R3.3A For an accessory structure, 25% or more of the roof surface area must utilize a like material or color of a primary structure, or the structure must share similar roof forms. R3.3B For an accessory structure, 25% or more of the non-roof surface area must utilize a like material of a primary structure. Carports and other post type construction are excluded if the roof material complies. Goal R3.40 Modulate and articulate roof forms to create building profile interest and to reduce the appearance of building mass and scale. Applies to public oriented façades visible from a public street, public spaces, and pedestrian environments. R3.4A Break up roof massing into primary and secondary roof elements that correspond to horizontal and vertical modulations or divi - sions in the façade, and denote key architectural elements, such as entries and porches. R3.4B For all public oriented façades, provide a complementary and proportionate level of roof form design and detail. R3.4C Align and correlate roof forms including elements over porches and entries, with the overall building design and use of materi - als. Examples include but are not limited to: continuation of roof forms with vertical elements such as columns, piers, and pilasters, or accenting gable type façades with rafters, corbels, or distinct material variations from other wall planes. R3.4D Sloped roofs shall have a significant pitch, to be no less than 5/12 (22-1/2 deg). R3.4E Sloped roofs must extend at least 12 inches beyond the face of walls. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †MULTI-FAMILY | CONTINUED »Last Modified: 02/12/2016. Questions? Contact the Planning Division at 208.884.5533 or www.meridiancity.org Architectural Standards D esign R eview C heC klist | R esi D ential Page | 4 BuilDing FoRm, ResiDential stanDaRDs (BFRs) Y N N/A ID #Description Comments Staff R3.4F Provide variations in roof profile including but not limited at least two of the following: two or more visible roof planes; dormers, lookout, turret, or cornice work such as corbels, spaced consistently along the façade plane. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. aRChiteCtuRal elements , ResiDential stanDaRDs (aeRs) Y N N/A ID #Description Comments Staff Intent R4.00 Promote attractive residential units that enhance the quality of neighborhoods and developments by integrating architectural elements and details with building designs. Goal R4.10 Use architectural elements and detailing to add interest and contribute to an aesthetic building character. Applies to building façades visible from a public street or public spaces. R4.1A Provide detailing that transition or frame façade material changes, and that integrate architectural elements such as lighting, doorways and windows. Examples include but are not limited to: cornice work, decorative caps on brick or stone, decorative lintels, porch railing, transom light, and shutters. Goal R4.20 Strategically locate focal points as key elements within the building design to enhance architectural character. Applies to building façades visible from a public street or public space. R4.2A Provide details that emphasize focal elements such as building corners, entries, or unique features. Detail examples include but are not limited to: quoin or rustication, canopies, and columns, or using roof lines and modulation to direct views. At least one focal element is required and must be accented with a contrast in color, texture, or modulation of the wall or roof plane. Goal R4.30 Incorporate windows into all applicable façade elevations and coordinate their placement and design with other architectural elements and material standards. R4.3A Windows must be provided to allow views to exterior activity areas or vistas, and must be provided on any façade facing a pedestrian area or common area used for children's recreation. R4.3B Anchor windows and other portals into building wall planes by integrating proportional detailing such as trim, lintels, shutters, railing, and ledges into the building design. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †MULTI-FAMILY | CONTINUED »Last Modified: 02/12/2016. Questions? Contact the Planning Division at 208.884.5533 or www.meridiancity.org Architectural Standards D esign R eview C heC klist | R esi D ential Page | 5 aRChiteCtuRal elements , ResiDential stanDaRDs (aeRs) Y N N/A ID #Description Comments Staff Goal R4.40 Residential entries and multifamily stairwells must provide convenient access from parking and pedestrian areas, and be integrated into the overall site and building design. R4.4A Primary building entries must be clearly defined using any unique combination of architectural elements, materials, or façade modulation meeting other architectural standards in this Manual. R4.4B Multifamily structures must provide internal site circulation to access individual residential units. R4.4C Multifamily stairwells must be integrated with the building design and provide residents protection from inclement weather. Use materials, modulation, and architectural elements which relate to and support other standards. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. mateRials, ResiDential stanDaRDs (maRs) Y N N/A ID #Description Comments Staff Intent R5.00 Ensure that materials used for residential development promote and establish an architectural character that contributes to the aesthetic qualities of neighborhoods and protects adjacent property values. Goal R5.10 Use complementary material combinations that contribute to a cohesive building design. Use materials from the following basic groups: wood, masonry, concrete, metal, and glazing. R5.1A For buildings with façades that face multiple public roadways and/or public spaces, use consistent material combinations, material quality, and architectural detailing. R5.1B Distinguish field materials from accent materials through pattern, texture, or additional detail visible from edge of nearest roadway. Alternate masonry or material courses may count toward this. R5.1C Where materials transition or terminate, provide detailing to express the natural appearance of the material. For example, wrap stone or stone-like products around visible corners to convey the appearance of mass, and not a thin veneer. R5.1D Non-durable materials, treatments, and finishes that deteriorate quickly with weather, ultra-violet light, and that are more suscep - tible to wear and tear are prohibited on permanent structures. R5.1E Unfinished or colored ordinary smooth face block, untextured concrete panels, and prefabricated steel panels are prohibited as a finish material for building façades, except an accent or secondary field material. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †MULTI-FAMILY | CONTINUED »Last Modified: 02/12/2016. Questions? Contact the Planning Division at 208.884.5533 or www.meridiancity.org Architectural Standards D esign R eview C heC klist | R esi D ential Page | 6 mateRials, ResiDential stanDaRDs (maRs) Y N N/A ID #Description Comments Staff Goal R5.20 Incorporate material and color changes as integrated details of the building design; maintain architectural integrity and promote a quality appearance and character. Applies to building façades visible from a public street, public space, and pedestrian environments. R5.2A Use a cohesive color scheme featuring a minimum of two field colors, a trim color, and an accent color or unique material. Garage door colors must coincide with this scheme or other accents. R5.2B For each wall plane area greater than 20-feet in length or height, and visible from prescribed areas, incorporate at least two distinct field materials, patterns, or colors in any combination, for at least 25% of the visible area. Windows or portals with qualifying accent materials may count toward this requirement, when meeting overall material requirements for the façade elevation. R5.2C Vinyl siding must include a mix of material patterns, including but not limited to: board and batten, horizontal and vertical lap, shake, or shingles, and meeting other material requirements. R5.2D Masonry as a qualifying accent material must be applied to 50 percent of the available wall length at a minimum height of 24 inches. (Available wall length does not include garage openings.) Goal R5.30 Use colors that complement building materials and support innova- tive and good design practices. Applies to building façades visible from a public street, public spaces, and pedestrian environments. R5.3A Use of subtle, neutral, or natural tones must be integrated with at least one accent or field material. R5.3B Use of intensely bright and fluorescent colors, as well as the widespread use of saturated hues without complementary colors, materials, and accents, is not allowed. R5.3C Materials or colors with high reflectance, such as some metals or reflective glazing, must not redirect light towards roadways, public spaces, or adjacent uses in a way which constitutes a public nuisance or safety hazard. Goal R5.40 When practical, organize building service equipment, including, but not limited to, utility, service, and mechanical, away from building entries, roadways, public spaces, and adjacent buildings. R5.4A All roof and wall mounted mechanical, electrical, communica- tions, and service equipment must be screened from public view from the adjacent public streets and properties by the use of parapets, walls, fences, enclosures, or by other suitable means. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †MULTI-FAMILY | CONTINUED »Last Modified: 02/12/2016. Questions? Contact the Planning Division at 208.884.5533 or www.meridiancity.org Architectural Standards D esign R eview C heC klist | R esi D ential Page | 7 lighting, ResiDential stanDaRDs (liRs) Y N N/A ID #Description Comments Staff Intent R6.00 Integrate architectural lighting as cohesive elements of building designs that contribute to the atmosphere of the built environ- ments and enhance safety. Goal R6.10 Use lighting on building exteriors to promote safe pedestrian environments along roadways, at intersections, and in public spaces. R6.1A Lighting fixture spacing and height along streetscapes and roadways must be placed to avoid conflicts with tree plantings. R6.1B Use energy-efficient architectural lighting. R6.1C Use lighting fixtures that are consistent with other decorative hardware on the building. For example, select lighting hardware with similar color and shape as other building hardware, use recessed lighting, incorporate uniform spacing, integrate with other accents and reveals, and coordinate specialty lights with predominate architectural features. Note: For a complete list of all Standards, along with photo examples, see the City of Meridian Architectural Standards Manual. †MULTI-FAMILY | CONTINUED »Last Modified: 02/12/2016. Questions? Contact the Planning Division at 208.884.5533 or www.meridiancity.org ~ This page left intentionally blank ~ ÓParadigm Senior Living Inc. 2019 503-222-6868 1 Development Narrative - Design Review Application 01-03-2020 1: Summary 2: Architectural Standards 1: Summary On November 12, 2019 the City of Meridian approved the Request for Annexation of 10.29 Acres of land as C-C (3.76 Acres) and R-15 (6.53 Acres) Zoning Districts; Preliminary Plat Consisting of Eight (8) Building Lots and One 1) Common Lot on 8.84 Acres of Land in the C-C and R-15 Zoning Districts; and Conditional Use Permit for a “ Nursing or Residential Care Facility” Consisting of 86 Dwelling Units on 3.48 Acres of Land in the R-15 Zoning District, by James Petersen, Inglewood Place at Meridian, LLC. Case No(s). H- 2019-0090 The Inglewood Place Subdivision is located at the North East corner of Victory Road and Eagle Road. This will be a two-phase development. Phase one will be R15 Zoned that will be developed as a Senior Living Community and phase two will be designated as a C-C Zone which could include uses such as retail, office or professional. During planning of the project great consideration was taken to provide a quality development that’s a good fit and contributes to the community. Through this process the design team has received approval for annexation by the planning department and the city council. We have also held a neighborhood meeting; our Engineer has personally met with the neighbors and with ACHD. The proposed development will be Mixed Use which is parallel with the City of Meridian’s comprehensive plan for this property. We are proposing for the East and Middle parcels to be R-15 and the West parcel adjacent to Eagle Road to be C-C zoned. 1.A: East Parcel, R-15 Zone This parcel of the property will be single level duplex’s (14 Units) for Senior Independent Living. 1.B: Middle Parcel, R-15 Zone This parcel will host a three-level senior living facility for Independent Living (46 Units), Assisted Living (30 Units) and Memory Care (10 Units). These living areas will be in 4 different wings all connected to a common core area. This design is visually appealing as it breaks up the mass of a large building and creates great outdoor open space. 1.C: West Parcels, C-C Zone The west parcels of the development which will be adjacent to Eagle Road and Victory road is ideal for commercial use. Below you will see an option for this commercial parcel. We do not have end users in place for the commercial area and the vision may be different than the conceptual drawings shown. We ask that the commercial area have flexibility so that we can get the right commercial user at this location. There will be multiple sidewalks between the commercial and senior living community for senior’s ease of access to the commercial amenities. ÓParadigm Senior Living Inc. 2019 503-222-6868 2 2: Architectural Standards 4.1: Architectural Character 4:1:A: Cohesive Design R1.1 – Great consideration has been taken to allow movement of pedestrians through the site. Building are oriented to face public streets and open spaces, and no visible façade has been ‘under-designed’. R1.2 – The townhomes, of which only 3 are adjacent to a public street, come in two color schemes, and are mirrored to create variety. 4:1:B: Building Scale The site is laid out in a way where the neighboring homes are adjacent to structures of similar and 1 story scale. The taller buildings are away from existing homes, and less visible from the main streets. 4:1:C: Building Form As is important with any project, we have made sure that no boring facades exist as outlined in the Design Standards. 4:1:D: Architectural Elements Details such as brick wainscot, brick caps, trellis, porches / decks and material transitions are all used in a way to enhance the proposed building’s appearance. The townhomes have patios in the front, and the Senior Living Facility has an ornate port-cochere. 4:1:E: Materials Material choices are biased on their lasting qualities and if they fit the Meridian community. Our pallet is a combination of real brick, quality asphalt shingles and cement fiber siding. It will have an appropriate layout with brick exceeding the 50% requirement and material or color transitions often. 4:1:F: Signs and Lighting We have chosen lighting that matches the design and theme, and will provide appropriate safety for the residences, while not contributing to light pollution. 4.2: Parking Lots / Pedestrian Walkways and Facilities Parking lots are broken up to reduce their scale into a more pedestrian friendly environment. They include may surrounding pathways and the drive aisles are no less than 26’ in width. VANVAN0102040NORTHPUBLIC CONNECTION VICTORY RD EAGLE ROADPUBLIC ROADMGMTMATCH LINEMATCH LINERETAIL PADSOUTHBBQPavilionRETAIL PADCENTRALRETAIL PADNORTHOFFICE BUILDINGBABABABABABABA111111113331111114441212225566222156137EDGE OF EXISTINGACCESS DRIVE8END OF VINYLFENCE12' GRAVEL DRIVE44END OF VINYL FENCE9999999KEYED NOTESPLANTING NOTESINSTALL CONCRETE PLANTER EDGE, TYPICAL, SEE DETAIL 5/L113121.THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALLUTILITY COMPANIES FOR FIELD LOCATION OF ALL UNDERGROUNDUTILITIES, INCLUDING UTILITY DEPTHS, PRIOR TO ANY EXCAVATION.CONTRACTOR SHALL TAKE SOLE RESPONSIBILITY FOR ANY AND ALL COSTOR OTHER LIABILITY INCURRED DUE TO DAMAGE OF UTILITIES,STRUCTURES, ETC.2.CONTRACTOR SHALL BE RESPONSIBLE FOR BECOMING AWARE OFALL RELATED EXISTING CONDITIONS, UTILITIES, PIPES, AND STRUCTURES,ETC. PRIOR TO BIDDING AND CONSTRUCTION.3.IF CONFLICTS ARISE BETWEEN SITE CONDITIONS ANDCONSTRUCTION DOCUMENTS, CONTRACTOR IS REQUIRED TO CONTACTOWNER'S REPRESENTATIVE FOR RESOLUTION. FAILURE TO MAKE SUCHCONFLICTS KNOWN TO THE OWNER'S REPRESENTATIVE WILL RESULT IN THECONTRACTOR BEING LIABLE TO RECONCILE CONFLICTS TO OWNER'SSATISFACTION.4.THE CONTRACTOR IS RESPONSIBLE TO FURNISH ALL PLANT MATERIALFREE OF PESTS AND/OR PLANT DISEASES AND WITH FULL AND NATURALSHAPE. ALL PLANT MATERIAL IS SUBJECT TO OWNER'S APPROVAL PRIORTO INSTALLATION.5.PRE-SELECTED OR "TAGGED" MATERIAL MUST BE INSPECTED BY THECONTRACTOR AND CERTIFIED PEST AND DISEASE FREE.6.THE CONTRACTOR IS OBLIGATED TO MAINTAIN AND WARRANT ALLPLANT MATERIALS AS SPECIFIED.7.PROVIDE MATCHING SIZES AND FORMS FOR EACH SPECIES OFTREES AND/OR PLANTS TO BE INSTALLED ON GRID OR SPACED IN ROWSAS INDICATED ON DRAWINGS. ALL PLANT MATERIAL TO BE PLANTED INSUCH MANNER AS TO BE EQUALLY SPACED. PLANT LOCATIONS SUBJECTTO ACCEPTANCE BY THE OWNERS REPRESENTATIVE.8.THE LANDSCAPE CONTRACTOR SHALL SCHEDULE PLANTINGOPERATIONS AND TAKE ALL NECESSARY PRECAUTIONS TO AVOIDWINTER, CLIMATIC, WILDLIFE, OR OTHER DAMAGE TO PLANT MATERIAL.9.CONTRACTOR SHALL PLACE A 12" DEEP LAYER MINIMUM OFTOPSOIL TO ALL SHRUB/PERENNIAL PLANTING AREAS. IMPORT TOPSOILAS REQUIRED.10.CONTRACTOR SHALL PLACE A 4" DEEP LAYER MINIMUM OFTOPSOIL TO ALL LAWN/TURF PLANTING AREAS. IMPORT TOPSOIL ASREQUIRED.11.PITS FOR ALL PLANT MATERIAL SHALL BE DUG 3 TIMES THE DIAMETEROF THE ROOT BALL. DEPTH OF PLANT PITS TO BE AS INDICATED INPLANTING DETAILS. EXCAVATED MATERIAL SHALL BE REMOVED FROMTHE SITE.12.TREES LESS THAN TWO-INCH CALIPER MUST BE DOUBLE-STAKEDUNTIL THE TREES MATURE TO A TWO-INCH CALIPER.13.CONTRACTOR TO PRUNE TREES AS DIRECTED BY LANDSCAPEARCHITECT FOR PROPER TREE SHAPING.14.CONTRACTOR TO REMOVE ALL TAGS, TIES AND FLAGGING FROMALL PLANT MATERIAL PRIOR TO SUBSTANTIAL COMPLETION.15.PLANT BACKFILL MIXTURE SHALL BE COMPOSED OF 3 PARTSTOPSOIL TO 1 PART HUMUS, ROTARY MIXED ON-SITE PRIOR TOINSTALLATION.6' HT. ORNAMENTAL METAL FENCE, TYPICAL, SEE DETAIL 1/L1103BERM - APPROXIMATE 1' CONTOURS SHOWN, TYPICAL46' HT. SOLID VINYL FENCE, TYPICAL, SEE DETAIL 2/L1105IRRIGATION EASEMENT - NO TREES TO BE PLANTED WITHIN, SEE PLATMAP.INGRESS/EGRESS EASEMENT, SEE CIVIL PLANS. PLANTS LIMITED TOLOW GROWING SHRUBS, PERENNIALS, AND GROUND COVERSPLACE 3" LAYER OF 1" CRUSHED ROCK OVER EXISTING ACCESSDRIVE. GRADE CRUSHED ROCK TO MATCH FINISH GRADE AT ALLEDGES OF EXISTING ACCESS DRIVE.EXISTING FENCE, FIELD VERIFY.25' STREET BUFFER / LANDSCAPE BUFFER6BUFFERS:·MIN. 25' LANDSCAPE BUFFER FROM PROPERTY LINE ADJACENT TOEAGLE RD AND VICTORY RD·MIN. 25' LANDSCAPE BUFFER BETWEEN DIFFERING ZONE TYPES.PLANTING LIMITED DUE TO SEWER EASEMENT.LINEAL FEET OF STREET FRONTAGE:1,269'ACREAGE DEDICATED TO OPEN SPACE:SENIOR FACILITY0.99 ACRESMULTI-FAMILY (COTTAGES)0.46 ACRES (SEE OPEN SPACE PLAN)STREET TREES·ALONG VICTORY RD AND EAGLE RD:51·RESIDENTIAL:27·TOTAL78NUMBER OF TREES PROVIDED IN COMMON LOTS:·ZONE C-C:45·CENTRAL R-15:50·EASTERN R-15:50MITIGATION FOR REMOVAL OF EXISTING TREES:·NO EXISTING TREES ON SITELANDSCAPE DESIGN STANDARDS7898' O.C.6' SOLID VINYL FENCE26'-0"30"3"12"POST CAPTOP RAIL, 1-1/2" x 5-1/2"PICKETS, TONGUE AND GROVE, 5/8" x 11-3/8"END CHANNELPOST, 5" x 5"BOTTOM RAIL WITH METAL REINFORCING,1-1/2" x 5-1/2"FINISH GRADE12" DIA. CONCRETE POST FOOTINGNOTES:1. DIMENSIONS ARE APPROXIMATE.2. PROVIDE SHOP DRAWINGS TO LANDSCAPEARCHITECT FOR APPROVAL PRIOR TOINSTALLATION.3. COLOR: WHITE WITH EMBOSSED TEXTURE.4. TOP OF CONCRETE CURB 1" ABOVE SOILFINISH GRADE.4"12" DIA. CONCRETEFOOTING8'-0" O.C.1" SQ. PICKET, TYP3-3/4" TYP.UNDISURBED ORCOMPACTED SUBGRADE12"9"+/-FINISH GRADE 6' HT. ORNAMENTAL METAL FENCE1NOTE:1. PRE-FABRICATED FENCE TO BE AMERISTAR,AEGIS II STYLE OR APPROVED EQUAL, ASMANUFACTURED BY AMERISTAR, TULSA, OK.PHONE: 800.321.8724.2. INSTALL FENCE PER MANUFACTURER'S WRITTENINSTRUCTIONS3. ALL STEEL FENCE COMPONENTS TO BE POWDERCOATED, BLACK.5. CONTRACTOR TO SUBMIT SHOP DRAWINGS FORAPPROVAL PRIOR TO INSTALLATION.CONCRETE PATIO/DECK6'-0"6"30"3"2"FENCE OVER CONCRETEPATIO/DECKFENCE OVER LAWN WITHCONCRETE CURBCONCRETE CURB, 6" x 8"L110OVERALLLANDSCAPE PLANREVISIONS:PROJECT NO.INGLEWOOD PLACE SUBDIVISION 3250 EAST VICTORY ROAD MERIDIAN IDAHOLANDSCAPEDATE:SHEET TITLE:SHEET NUMBER:1807712 NOVEMBER 2019ArchitectureInterior DesignLandscape ArchitectureLand PlanningConstruction Management5151 South 900 East, Suite 200Salt Lake City, Ut 84117ph. 801.269.0055fax 801.269.1425www.thinkaec.comThe designs shown and described herein includingall technical drawings, graphic representation &models thereof, are the copyrighted work of ThinkArchitecture, Inc. and connot be copied,duplicated, or commercially exploited in whole orin part without the sole and express writtenpermission from THINK Architecture, Inc.These drawings are available for limited reviewand evaluation by clients, consultants, contractors,government agencies, vendors, and officepersonnel only in accordance with this notice.7 NOVEMBER 2019OVERALL LANDSCAPELA-16858S T ATE OF IDAHOLICENSED LANDSCAPE A R CHITE C T **TR O Y R SANDERS Meridian, Idaho2020 Jan 07 PROPOSED BUILDING LOCATION IS AN ESTIMATE BASED ON A CIVIL SURVEY OF THE HEIGHTS AND LOCATIONS OF ADJACENT BUILDINGS. COLORS ARE REPRESENTATIONAL ONLY. FINAL COLORS MAY VARY FROM ABOVE REPRESENTATIONINGLEWOOD PLACETOWNHOMES - MATERIAL BOARD>) 6 "@ >) 6 :64#.’;#2# -’<**# -=# >)26 +%%.#$6 -#. ")E# !"# $%&’# (’ ) *(& $%&’#6 +),% .:’;’<.6*=<#"&# <.6*= >%?%,#$%%& <"# & !"#$%&!’ ()*+C) 6 6 C) 6 C) 6 6- "& 6* "# @64#.’>#2# -’A)0’B6&6 !<# C)26 +%%.#>/#)-6 ! D#).- ( )** ,-’*.’(/#C) 6 C) 6 6- >) 6 "@ >) 6 >) 6 6 ") C/6 !"#’A%%F6 !;#.-)6 G##&+)H I#F J#)-/#.#& J%%&+*,-.*(&/"& 6* "# C) 6 6 C) 6 @64#.’>#2# -’F#.-6*)"’B6&6 !<# C)26 +%%.#$/6-# &%G#%( 0"(’ 1 2’3’(/ ,-’*.’(/4 5 1"!)’*,-’*.’(/ )(. # 6" 7 !!)/"#;")-’<#)2’+#-)"’=%%>6 !?"),,6* +#-)"’=%%>6 !@#.2% - <")-# !"#$%&!’ ()*+ Meridian, Idaho2020 Jan 07 PROPOSED BUILDING LOCATION IS AN ESTIMATE BASED ON A CIVIL SURVEY OF THE HEIGHTS AND LOCATIONS OF ADJACENT BUILDINGS. COLORS ARE REPRESENTATIONAL ONLY. FINAL COLORS MAY VARY FROM ABOVE REPRESENTATIONINGLEWOOD PLACESENIOR LIVING FACILITY - MATERIAL BOARD:64#.’;#2# -’<**# -=# >)26 +%%.#?).-/"@ AB,,#- !"# $%&’#>) 6 >) 6 6 ") 6 >) 6 "@ :64#.’;#2# -’<**# -=# >)26 +%%.#C-#2 D.## !"# $%&’# (’ ) *(& $%&’#>) 6 6 ") 6 +),% .:’;’<.6*=<#"&# <.6*= >%?%,#$%%& <"# & !"#$%&!’ ()*+C) 6 6 C) 6 C) 6 6- >) 6 "@ >) 6 :64#.’;#2# -’<**# -=# >)26 +%%.#$6 -#. ")E# !"# $%&’# (’ ) *(& $%&’#6 "& 6* "# @64#.’>#2# -’A)0’B6&6 !<# C)26 +%%.#>/#)-6 ! D#).- ( )** ,-’*.’(/#C) 6 C) 6 6- "& 6* "# C) 6 6 C) 6 @64#.’>#2# -’F#.-6*)"’B6&6 !<# C)26 +%%.#$/6-# &%G#%( 0"(’ 1 2’3’(/ ,-’*.’(/4 5 1"!)’*,-’*.’(/ )(. # 6" 7 !!)/"#;")-’<#)2’+#-)"’=%%>6 !?"),,6* +#-)"’=%%>6 !@#.2% - <")-# !"#$%&!’ ()*+Exterior Accent ColorExterior Accent ColorExterior Base ColorAccent Roof over portchesExterior Accent ColorExterior Accent Color>) 6 "@ >) 6 >) 6 6 ") C/6 !"#’A%%F6 !;#.-)6 G##&+)H I#F J#)-/#.#& J%%&+*,-.*(&/ Meridian, Idaho2020 Jan 07 PROPOSED BUILDING LOCATION IS AN ESTIMATE BASED ON A CIVIL SURVEY OF THE HEIGHTS AND LOCATIONS OF ADJACENT BUILDINGS. COLORS ARE REPRESENTATIONAL ONLY. FINAL COLORS MAY VARY FROM ABOVE REPRESENTATIONINGLEWOOD PLACEEXTERIOR LIGHTING FIXTURES           ! " #$$$%  & % '$      ()%**+%,-.  (/%**0#"& )%*12"&3 3# " 1 1&(%**02"& (%**0#4& (*%),0 5'-. -.67"#"& )%*1! " 5 744 5 744  8)("&17  5 4 6 . #  (,*#937 : '-;647  (6 .#  "'! " (,*#1  6471 # )**# 1< = &  1  4"'7< ),/*(($"6  8<65<6% & '((-   > ! 4 ? 4@A&((B*(* 3//%,,%,*/  & % ()(53 ?44  7:  & "$&7 %8 ? 7  4 " ? 7 $& 7474 :  4 %)5 4 -C7? & 4 C7?   4   . 7: 4 33  %APPLICATIONS Kichler Lighting’s 120-277V LED small wall pack fixtures provide optically controlled wide spread light distribution designed to replace up to a 70W metal halide luminaire for mounting heights of 10’ to 12’. Typical applications include shipping and storage buildings, parking structures, hotels or office parks.CONSTRUCTION Housing and gasketed doorframe assembly constructed from die-cast aluminum. Housing includes ½” coin plugs with o-rings for surface mounted conduit entry or photocell. Lens is composed of heat and impact resistant borosilicate glass. Tamper-resistant stainless steel hardware. FINISH Fixture housing and doorframe assembly feature a UV stabilized Textured Architectural Bronze™ (AZT) powder coat paint finish. MOUNTING Hinged 2-piece assembly mounts with a mounting plate (with built-in level) directly over a 4” recessed junction box (by others). Mounting height is 10’ to 12’.LED CHARACTERISTICS Color consistent LEDs. Lumen Maintenance: L70 to ≥ 55,000-hours. CRI: 70+ (see chart).OPTICAL DISTRIBUTION Type I distribution, ideal for illumination of parking area and business perimeters.ELECTRICAL 120V-277VAC (50/60 Hz). Integrated surge protection (4kV) is standard. Driver is fully potted.LISTINGS AND CERTIFICATION UL 1598 / CSA 250.0 listed for wet locations; Operating temperature -40° C to +40°; UL 8750; IP65 Rated. Select models are DLC Qualified (see Ordering Matrix). ACCESSORY 16245BK Photocell deactivates light during the day. PROJECT:TYPE:ORDERING:COMMENTS:C-Series LED120V-277V LED Traditional Wall Pack, 19W16231®+LIMITED WARRAN T Y +SE E K IC HLER.COM/WARRANTY5YEAR DRYERWASHERSHELVES15" R&SSHELVES 15" R&S W.C.SHELVES15" R&SSHELVES15" R&SW.C.WASHERSHELVES15" R&SW.C.RANGERANGE DW DWDRYER3 3 AA BB 5 5 4 4 1 1 2 2 MECH MASTER BATH MECH BEDROOM BATH GARAGE KITCHEN LIVING MASTER BEDROOM LIVING DINING KITCHEN FLEX MUD GARAGE LOGGIA VERANDA LOGGIA VERANDA FLEX BATH 1 A301 1 A301 1 A302 1 A302 2 A301 2 A301 2 A302 2 A302 C C C E B C A A701 5 6 A701 31 2 4 A702 31 2 4 A702 5 6 A702 7 8 9 A201 1 A2012 A202 1 A202 2 64'-0" 17'-0"14'-0"15'-0"18'-0" 16'-0"1'-0"56'-0"2'-0"6'-0"48'-0"5'-6"10'-6"15'-0"15'-0"12'-6"5'-6"3'-0"53'-0"7 1/4"3'-0"3'-4 3/4"7 1/4"5 1/2"1 3/4"11'-9"7 1/4"4'-10 3/4"7 1/4"7 1/4"4'-10 3/4"7 1/4"7 1/4"5'-0"7 1/4"9'-9 1/2"7 1/4"7 1/4"12'-3 1/2"7 1/4"4'-6"7 1/4"3 A501 3 A501 3 A501 3 A501 3 A501 G0035 G003 3 G003 4 G003 6 1. ALL DIMENSIONS ARE TO INTERIOR FACE-OF-STUD (F.O.S.) UNLESS NOTED OTHERWISE. 2. CEILING HEIGHTS MEASURED FROM PLYWOOD OR CONCRETE - SEE SECTIONS 3. REFER TO ENLARGED PLANS FOR ALL UNIT DIMENSIONS, WINDOW TYPES, DOORS AND WALLS. 4. REFER TO ENLARGED PLANS FOR ALL DECKS/PATIOS. 5. COORDINATE WITH ALL ENLARGED PLANS FOR ADDITIONAL INFORMATION AND DETAILS. 6. ALL TOPPING SLABS MUST BE POURED AFTER ROOF IS COMPLETE AND BUILDING IS DRIED IN. 7. SEE SHEET A002 FOR PROJECT GENERAL NOTES AND SHEET A003 FOR PROJECT KEYNOTES. REVIEW ALL NOTES PRIOR TO CONSTRUCTION. 8. COORDINATE WITH STRUCTURAL FRAMING PLANS AND SHEAR WALL PLANS FOR LOCATIONS OF COLUMNS, BEAMS, SHEAR WALLS, ETC. 9. COORDINATE WITH BUILDER/OWNER FOR ALL INTERIOR FINISHES 10. COORDINATE WITH ELECTRICAL DRAWINGS FOR ALL LIGHTING, POWER AND DATA REQUIREMENTS. 11. ALL EXTERIOR WALLS ARE ASSUMED TO BE 2X6 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE. 12. ALL INTERIOR WALLS ARE ASSUMED TO BE 2X4 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE. 13. ALL ROOF TRUSSES TO HAVE RAISED ENERGY HEEL CONSTRUCTION TO ALLOW FOR FULL DEPTH INSULATION OVER EXTERIOR WALLS (COORDINATE INSULATION REQUIREMENTS WITH RESCHECKS). FLOOR PLAN GENERAL NOTES FLOOR PLAN KEYNOTES HATCH PATTERN DESCRIPTION FLOOR PLAN LEGEND POURED IN PLACE CONCRETE WALL CARPET FINISH HATCH PATTERN DESCRIPTION WOOD STUD WALL STONE VENEER CMU BLOCK WALL METAL STUD WALL TILE FINISH EXTERIOR CONCRETE SLABS PROJECT NO. SHEET TITLE:Plot Date:Architecture Interior Design Landscape Architecture Land Planning Construction Management 5151 South 900 East, Suite 200 Salt Lake City, Ut 84117 ph. 801.269.0055 fax 801.269.1425 www.thinkaec.com The designs shown and described herein including all technical drawings, graphic representation & models thereof, are the copyrighted work of Think Architecture, Inc. and connot be copied, duplicated, or commercially exploited in whole or in part without the sole and express written permission from THINK Architecture, Inc.These drawings are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors, and office personnel only in accordance with this notice. SHEET NUMBER: REVISIONS: DATE:1/7/2020 3:59:20 PMINGLEWOOD SENIOR LIVING TOWNHOMESMERIDIAN SENIOR LIVINGJan 7, 2020 18077 LEVEL 1 FLOOR PLAN A103 CONSTRUCTION DOCUMENTS -DECEMBER 20, 20191/4" = 1'-0"A103 LEVEL 1 - FLOOR PLAN 1 KEYNOTE INSTRUCTIONAL NOTE: REFER TO MATERIAL SPECIFICATIONS DOCUMENT FOR DETAILED INFORMATION REGARDING EACH FINISH MATERIAL HATCH PATTERN DESCRIPTION ELEVATION/ SECTION MATERIAL LEGEND WOOD CEDAR SHAKE ROOFING SYSTEM ELEVATION/ SECTION KEYNOTES LAP SEAM COPPER ROOFING SYSTEM SINGLE PLY ROOFING MEMBRANE SYSTEM 2X10 CEDAR CHANNEL LAP VERTICAL SIDING SYSTEM WITH SQUARE EDGES EXTERIOR STONE VENEER LEVEL 1 -FLOOR PLAN 100'-0" LEVEL 1 -FLOOR PLAN 100'-0" UPPER ROOF BEARING 110'-0" UPPER ROOF BEARING 110'-0" 3 54122 A301 2 A302 15 A502 15 A502 7 A502 7 A502 3 A501 14 A502 1 A501 1 A501 3 A501 11 A502 2. A502 12 A502 10'-0"LEVEL 1 -FLOOR PLAN 100'-0" LEVEL 1 -FLOOR PLAN 100'-0" UPPER ROOF BEARING 110'-0" UPPER ROOF BEARING 110'-0" AB1 A301 1 A302 15 A502 7 A502 22 A501 3 A501 A502 20 8 A502 7 A502 3 A501 22 A501 7 A502 15 A502 PROJECT NO. SHEET TITLE:Plot Date:Architecture Interior Design Landscape Architecture Land Planning Construction Management 5151 South 900 East, Suite 200 Salt Lake City, Ut 84117 ph. 801.269.0055 fax 801.269.1425 www.thinkaec.com The designs shown and described herein including all technical drawings, graphic representation & models thereof, are the copyrighted work of Think Architecture, Inc. and connot be copied, duplicated, or commercially exploited in whole or in part without the sole and express written permission from THINK Architecture, Inc.These drawings are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors, and office personnel only in accordance with this notice. SHEET NUMBER: REVISIONS: DATE:1/7/2020 3:59:20 PMINGLEWOOD SENIOR LIVING TOWNHOMESMERIDIAN SENIOR LIVINGJan 7, 2020 18077 EXTERIOR ELEVATIONS A201 CONSTRUCTION DOCUMENTS -DECEMBER 20, 20191/4" = 1'-0"A201 SOUTH ELEVATION 1 1/4" = 1'-0"A201 EAST ELEVATION 2 KEYNOTE INSTRUCTIONAL NOTE: REFER TO MATERIAL SPECIFICATIONS DOCUMENT FOR DETAILED INFORMATION REGARDING EACH FINISH MATERIAL HATCH PATTERN DESCRIPTION ELEVATION/ SECTION MATERIAL LEGEND WOOD CEDAR SHAKE ROOFING SYSTEM ELEVATION/ SECTION KEYNOTES LAP SEAM COPPER ROOFING SYSTEM SINGLE PLY ROOFING MEMBRANE SYSTEM 2X10 CEDAR CHANNEL LAP VERTICAL SIDING SYSTEM WITH SQUARE EDGES EXTERIOR STONE VENEER LEVEL 1 -FLOOR PLAN 100'-0" UPPER ROOF BEARING 110'-0" 354 122 A301 2 A302 7 A502 2. A502 14 A502 15 A502 7 A502 14 A502 14 A502 17 A502 A502 20 A502 20 3 A501 17 A502 10 A501 LEVEL 1 -FLOOR PLAN 100'-0" UPPER ROOF BEARING 110'-0" A B1 A301 1 A302 15 A502 15 A502 7 A502 7 A502 A502 20 8 A502 14 A502 7 A502 7 A502 A502 20 A502 19 15 A502 PROJECT NO. SHEET TITLE:Plot Date:Architecture Interior Design Landscape Architecture Land Planning Construction Management 5151 South 900 East, Suite 200 Salt Lake City, Ut 84117 ph. 801.269.0055 fax 801.269.1425 www.thinkaec.com The designs shown and described herein including all technical drawings, graphic representation & models thereof, are the copyrighted work of Think Architecture, Inc. and connot be copied, duplicated, or commercially exploited in whole or in part without the sole and express written permission from THINK Architecture, Inc.These drawings are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors, and office personnel only in accordance with this notice. SHEET NUMBER: REVISIONS: DATE:1/7/2020 3:59:21 PMINGLEWOOD SENIOR LIVING TOWNHOMESMERIDIAN SENIOR LIVINGJan 7, 2020 18077 EXTERIOR ELEVATIONS A202 CONSTRUCTION DOCUMENTS -DECEMBER 20, 20191/4" = 1'-0"A202 NORTH ELEVATION 1 1/4" = 1'-0"A202 WEST ELEVATION 2 KEYNOTE INSTRUCTIONAL SHELVES15" R&SKOHLERW.C. W/D 15" R&S15" R&S KOHLERW.C. KOHLER W.C.WASH/DRYERKOHLERW.C.RANGE DW15" R&S15" R&SKOHLER W.C.KOHLERW.C.KOHLERW.C.KOHLERW.C.KOHLERW.C.SHELVES15" R&SKOHLER W.C. W/D15" R&S15" R&SSHELVES15" R&SKOHLER W.C. W/D 15" R&S15" R&SWASH/DRYERKOHLERW.C.RANGEDW 15" R&S15" R&S KOHLERW.C.W/DSHELVES15" R&SDWW.C.KOHLERW.C.W.C.KOHLERW.C.KOHLERW.C.KOHLER W.C. KOHLER W.C.FIREPLACEW/DSHELVES15" R&SDWW.C.W/DSHELVES15" R&SDWW.C.W/DSHELVES15" R&SDWW.C.W/DSHELVES15" R&SDWW.C.W/DSHELVES15" R&SDWW.C.W/DSHELVES15" R&SDWW.C.KOHLERW.C.KOHLERW.C.1. ALL DIMENSIONS ARE TO INTERIOR FACE-OF-STUD (F.O.S.) UNLESS NOTED OTHERWISE. 2. CEILING HEIGHTS MEASURED FROM PLYWOOD OR CONCRETE - SEE SECTIONS 3. REFER TO ENLARGED PLANS FOR ALL UNIT DIMENSIONS, WINDOW TYPES, DOORS AND WALLS. 4. REFER TO ENLARGED PLANS FOR ALL DECKS/PATIOS. 5. COORDINATE WITH ALL ENLARGED PLANS FOR ADDITIONAL INFORMATION AND DETAILS. 6. ALL TOPPING SLABS MUST BE POURED AFTER ROOF IS COMPLETE AND BUILDING IS DRIED IN. 7. SEE SHEET A002 FOR PROJECT GENERAL NOTES AND SHEET A003 FOR PROJECT KEYNOTES. REVIEW ALL NOTES PRIOR TO CONSTRUCTION. 8. COORDINATE WITH STRUCTURAL FRAMING PLANS AND SHEAR WALL PLANS FOR LOCATIONS OF COLUMNS, BEAMS, SHEAR WALLS, ETC. 9. COORDINATE WITH BUILDER/OWNER FOR ALL INTERIOR FINISHES 10. COORDINATE WITH ELECTRICAL DRAWINGS FOR ALL LIGHTING, POWER AND DATA REQUIREMENTS. 11. ALL EXTERIOR WALLS ARE ASSUMED TO BE 2X6 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE. 12. ALL INTERIOR WALLS ARE ASSUMED TO BE 2X4 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE. 13. ALL ROOF TRUSSES TO HAVE RAISED ENERGY HEEL CONSTRUCTION TO ALLOW FOR FULL DEPTH INSULATION OVER EXTERIOR WALLS (COORDINATE INSULATION REQUIREMENTS WITH RESCHECKS). FLOOR PLAN GENERAL NOTES FLOOR PLAN KEYNOTES HATCH PATTERN DESCRIPTION FLOOR PLAN LEGEND POURED IN PLACE CONCRETE WALL CARPET FINISH HATCH PATTERN DESCRIPTION WOOD STUD WALL STONE VENEER CMU BLOCK WALL METAL STUD WALL TILE FINISH EXTERIOR CONCRETE SLABS 3 3 I I A A A206 4 A202 1 A203 3 A202 2 A202 3 A206 1 A203 1 A203 2 2 A301A 2 A301A 1 A301A 1 A301A 1 A302A 1 A302A 2 A302A 2 A302A 1 A301B MEMORY CARE ASSISTED LIVING MAIL 102 MECH 117 DRY STRG 122 1 1 C C E E B H 2 A301B BA 1 A306A 2 A306A 10'-2 3/4"10'-0 3/4"37'-4"10'-7 1/4"48'-5 1/2"10'-7 1/4"13'-10 1/8" 2 2 1'-1 1/4"5'-3 3/4"2'-6"10'-5"2'-6"3'-8"3'-8"2'-6"3'-5 1/4"5'-10 3/4"2'-6"2'-6"5'-4"5'-4"2'-6"2'-6"5'-10 3/4"4'-1 1/4"2'-6"4'-0"6'-9 1/4"2'-6"3'-10 3/4"5'-8"2'-6"2'-6"5'-4"5'-4"2'-6"2'-6"6'-1 1/4"162'-0"8'-0"48'-0"27'-0"3'-0" 103'-4 3/8" G 2'-0"4'-8"51'-4"45'-0"29'-8"29'-4"58'-0"2'-0"2'-0"41'-0"33'-8"29'-4"45'-0"13'-0"162'-0"2 A305B A A A B A A A B A A A B A A B A A B A A A B A A A B A A A A B A A B A A A B A A B A A B A A B A A B A B B B B A B A A B A A B A A B A A B A A B A A B A A B A2'-0"2'-0"2'-0"3'-0"1'-0"2'-0"- --- 5'-1 3/4"2'-6"2'-6"4'-8 1/4"5'-1 3/4"2'-6"2'-6"5'-1 3/4"4'-8 1/4"2'-6"2'-6"4'-8 1/4"5'-1 3/4"2'-6"2'-6"5'-1 3/4"4'-8 1/4"2'-6"2'-6"5'-1 3/4"4'-8 1/4"2'-6"2'-6"5'-11 7/8"4'-11"2'-6"2'-6"5'-1 3/4"4'-11"2'-6"2'-6"5'-1 1/2"24'-0"5'-11 1/4"15'-0 3/4"15'-0 1/2"14'-7 1/2"141'-1 5/8"7'-5"15'-2"13'-0"24'-4 3/4"9'-7 1/4"32'-5 1/2"10'-7 1/4"45'-7 1/4" 37'-9 1/4" 6'-1"6'-1"4'-0"2'-6"2'-6"30'-0 1/2"2'-6"2'-6"3'-11 1/2"3'-3"2'-6"7'-9"7'-9"2'-6"3'-3" 13'-0 3/4"14'-10"15'-4 1/2"14'-3 1/2"15'-3 1/2"14'-11"15'-7 1/8" 3'-10 3/4"2'-6"3'-8"3'-8"2'-6"10'-5"2'-6"9'-0"2'-6"6'-9"4'-0"2'-6"4'-1 1/4"5'-10 3/4"2'-6"2'-6"10'-8"2'-6"2'-6"11'-4"2'-6"2'-6"5'-6 3/4"4'-1 1/4"2'-6"4'-0"6'-9"2'-6"4'-1 3/4" UNIT A102 UNIT A104 UNIT A106 UNIT A108 UNIT A110 UNIT A112 UNIT A101 UNIT A103 UNIT A105 UNIT A107 UNIT A109 UNIT A111 CORRIDOR 118 UNIT M110 UNIT M109 UNIT M108 UNIT M107 UNIT M106 UNIT M105 UNIT M104 UNIT M103 UNIT M102 UNIT M101 OFFICE 115 STRG 116 STAGE KITCHEN 113 MC TUB 109 MC LINEN 110 MC RR 112 MC ACTIVITY 114 CORRIDOR 111 MEDS 105 RES. SERVICES 106 LAUNDRY 107 WOMENS 104 MENS 103 MAID 121 KTCHN OFFICE 120 STAIRS 119 20'-4"3'-8"6'-1"8'-3"9'-8"38'-0"9'-2 3/8"6'-11" - --- CORRIDOR 108 PROJECT NO. SHEET TITLE:Plot Date:Architecture Interior Design Landscape Architecture Land Planning Construction Management 5151 South 900 East, Suite 200 Salt Lake City, Ut 84117 ph. 801.269.0055 fax 801.269.1425 www.thinkaec.com The designs shown and described herein including all technical drawings, graphic representation & models thereof, are the copyrighted work of Think Architecture, Inc. and connot be copied, duplicated, or commercially exploited in whole or in part without the sole and express written permission from THINK Architecture, Inc. These drawings are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors, and office personnel only in accordance with this notice. SHEET NUMBER: REVISIONS: DATE: BUILDING KEY LEGEND AREA A 1/7/2020 3:41:02 PMINGLEWOOD PLACE - SENIOR LIVING3250 E VICTORY RDMERIDIAN IDAHOJan 7, 2020 18077 LEVEL 1 FLOOR PLAN A101A ANNEXATION SUBMITTALKEYNOTE INSTRUCTIONAL 1/8" = 1'-0"A101A LEVEL 1A - FLOOR PLAN 1 KOHLERW.C.SHELVES15" R&SW.C. W/D SHELVES15" R&SDWMAIL BOX MAIL BOX ?OVENOVEN WELLWORTHKOHLERW.C.FIREPLACEFIREPLACEWELLWORTH KOHLER W.C.MAIL BOXKOHLERW.C.KOHLERW.C.UP HATCH PATTERN DESCRIPTION FLOOR PLAN LEGEND POURED IN PLACE CONCRETE WALL CARPET FINISH HATCH PATTERN DESCRIPTION WOOD STUD WALL STONE VENEER CMU BLOCK WALL METAL STUD WALL TILE FINISH EXTERIOR CONCRETE SLABS 1. ALL DIMENSIONS ARE TO INTERIOR FACE-OF-STUD (F.O.S.) UNLESS NOTED OTHERWISE. 2. CEILING HEIGHTS MEASURED FROM PLYWOOD OR CONCRETE - SEE SECTIONS 3. REFER TO ENLARGED PLANS FOR ALL UNIT DIMENSIONS, WINDOW TYPES, DOORS AND WALLS. 4. REFER TO ENLARGED PLANS FOR ALL DECKS/PATIOS. 5. COORDINATE WITH ALL ENLARGED PLANS FOR ADDITIONAL INFORMATION AND DETAILS. 6. ALL TOPPING SLABS MUST BE POURED AFTER ROOF IS COMPLETE AND BUILDING IS DRIED IN. 7. SEE SHEET A002 FOR PROJECT GENERAL NOTES AND SHEET A003 FOR PROJECT KEYNOTES. REVIEW ALL NOTES PRIOR TO CONSTRUCTION. 8. COORDINATE WITH STRUCTURAL FRAMING PLANS AND SHEAR WALL PLANS FOR LOCATIONS OF COLUMNS, BEAMS, SHEAR WALLS, ETC. 9. COORDINATE WITH BUILDER/OWNER FOR ALL INTERIOR FINISHES 10. COORDINATE WITH ELECTRICAL DRAWINGS FOR ALL LIGHTING, POWER AND DATA REQUIREMENTS. 11. ALL EXTERIOR WALLS ARE ASSUMED TO BE 2X6 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE. 12. ALL INTERIOR WALLS ARE ASSUMED TO BE 2X4 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE. 13. ALL ROOF TRUSSES TO HAVE RAISED ENERGY HEEL CONSTRUCTION TO ALLOW FOR FULL DEPTH INSULATION OVER EXTERIOR WALLS (COORDINATE INSULATION REQUIREMENTS WITH RESCHECKS). FLOOR PLAN GENERAL NOTES FLOOR PLAN KEYNOTES 3 3 4 4 I A A - F F - A206 3 A206 1 2 A305A 2 A305A 1 A305A 1 A305A 1 A301B B B H H 2 A301B CBA 2 A307A 1 A305B 1 A305B D D G G121'-0"11 1/4" 8'-4 1/2" 11 1/4" 4" 11 1/4" 7'-9" 11 1/4" 4" 11 1/4" 8'-4 1/2" 11 1/4" 20'-2 1/2" 11 1/4" 9'-4 5/8" 11 1/4" 3" 11 1/4" 8'-8" 11 1/4" 4" 11 1/4" 8'-8" 11 1/4" 4" 11 1/4" 9'-3 5/8" 11 1/4" 25'-9"4'-0"10'-10 1/2"3'-11 3/8" 22'-6 1/8"43'-10"5'-3"2'-6"5'-3"9'-8 3/4"6'-6 7/8" 1 A303B 2 A305B 1 A304C 2 A304C A A A A A A A A 3'-8 1/2"3'-6"12'-3"95'-2 3/8" 15'-1 1/2"15'-6" 2 A303C 89'-0 7/8"6'-6 7/8" - --- IL DINE 124 PRIVATE DINE. 135 BISTRO 136 AL DINE 137 AL LOUNGE 138 MENS 103 MAIL 102 LOBBY 101 C STR 141 LOUNGE 142 IL LOUNGE 140THEATER 139 KITCHEN 123 STRG 125 - --- LOBBY VEST. 100 PROJECT NO. SHEET TITLE:Plot Date:Architecture Interior Design Landscape Architecture Land Planning Construction Management 5151 South 900 East, Suite 200 Salt Lake City, Ut 84117 ph. 801.269.0055 fax 801.269.1425 www.thinkaec.com The designs shown and described herein including all technical drawings, graphic representation & models thereof, are the copyrighted work of Think Architecture, Inc. and connot be copied, duplicated, or commercially exploited in whole or in part without the sole and express written permission from THINK Architecture, Inc. These drawings are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors, and office personnel only in accordance with this notice. SHEET NUMBER: REVISIONS: DATE: BUILDING KEY LEGEND AREA B 1/7/2020 3:41:09 PMINGLEWOOD PLACE - SENIOR LIVING3250 E VICTORY RDMERIDIAN IDAHOJan 7, 2020 18077 LEVEL 1 FLOOR PLAN A101B ANNEXATION SUBMITTALKEYNOTE INSTRUCTIONAL 1/8" = 1'-0"A101B LEVEL 1B - FLOOR PLAN 1 RANGEDWW/D W.C.RANGEDWW/DW.C.RANGEDWW/DW.C.RANGEDWW/DW.C.RANGEDWW/DW.C.SHELVES15" R&SW/DW.C.15" R&S 15" R&SW.C.RANGEDWSHELVES15" R&SW/DW.C.15" R&S15" R&SW.C.RANGEDWSHELVES15" R&SW/DW.C.15" R&S15" R&SW.C.RANGEDWRANGEDWW/D W.C.RANGEDWW/D W.C.LOCKERSKOHLERW.C.KOHLERW.C. KOHLER W.C.WASHDRYCARTFOLDINGCART CART SHELVES15" R&S W/D KOHLERW.C.15" R&S15" R&S RANGEDWSHELVES15" R&SW/D KOHLERW.C.15" R&S15" R&SRANGEDWSHELVES15" R&S W/D KOHLERW.C.15" R&S15" R&S RANGEDWSHELVES15" R&SW/D KOHLERW.C.15" R&S15" R&SRANGEDWUP 4 4 A A F F J J A2062 A206 3 A204 3 A2042 A204 1 A205 3 A2052 A205 1 2 A303A 1 A303A 2 A304A 2 A304A 1 A304A 1 A304A INDEPENDENT LIVING INDEPENDENT LIVING CB 1 A307A2 A307A - --- 5 6 7 7 8 8 D D 168'-0"168'-0"4'-0"23'-6 1/2"26'-9 1/2"4'-8"4'-0"4'-0"50'-4"8'-8"4'-8 3/4"4'-6"7'-10"2'-6"4'-8"4'-8"2'-6"7'-10"4'-6"4'-3 1/4"4'-2 1/4"2'-6"2'-6"6'-4"2'-6"5'-11"3'-0"5'-9 1/2"2'-6"2'-9"5'-6"3'-0"5'-6"6'-1"6'-7 1/2" 1 A303B 1 A303C 1 A304C 2 A304C 9'-0"41'-4"8'-8"A A A A A A B A A A A B C C CCAAABAAAA A A A A A A A A A B A CC BA AAABAAAAA8'-4"5'-1 1/2"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"10'-8 3/8"48'-0"23'-11 1/4"6'-0 3/4"7'-11 3/4"14'-0"12'-5 3/4" 9'-4 3/4"30'-0"9'-0"9'-0"15'-2 3/4"6'-0 3/4"23'-11 1/4"10'-2 3/4" 6'-10 1/2"2'-2 1/4"7'-9"2'-6"4'-11"4'-8"2'-6"7'-10"8'-9 1/4"4'-2 1/4"2'-6"2'-6"6'-4"2'-6"5'-11"2'-10"5'-9 1/2"2'-6"2'-11"5'-6"3'-0"5'-6"6'-1"6'-4 3/4" 123'-9 1/4" 4'-10 3/4"4'-6"7'-10"2'-6"4'-8"4'-8"2'-6"7'-10"4'-6"4'-6"4'-6"4'-6"7'-10"2'-6"4'-10 3/4"3'-0 3/4"3'-0"5'-11"2'-6"6'-4"2'-6"2'-6"4'-2 1/4" 4'-11 1/4"2'-6"7'-9 1/2"3'-6 1/2"5'-2 3/4"5'-0 3/4"10'-2"4'-8"4'-1 1/4"4'-2 1/4"2'-6"2'-6"6'-4"2'-6"5'-11"3'-0"3'-0 3/4"2'-8 3/4"2'-6"2'-9"5'-6"3'-0"5'-6"6'-1"5'-2 3/4"1'-2" 11'-0"9'-0 3/4"30'-2"9'-2 3/4"23'-5 3/4"14'-0 1/2"14'-0"12'-5 3/4"10'-3 1/4" 123'-5 1/2" 10'-11"2"9'-2 3/4"30'-0"32'-8 1/2"14'-0 1/2"14'-0"12'-8 1/2" - --- 2 A303C 4'-6 1/2"- ---4'-0"- --- - ---63'-0"42'-0"63'-0"4'-0"23'-6 1/2"19'-5 1/2"16'-0"3'-8 1/2"3'-6"5'-8 5/8"6'-6 3/8"- --- LAUNDRY 127 STAFF 128 ART 131 MAID 132 MENS 133 WOMENS 134 CORRIDOR 143 STAIRS 126 STRG 125 STAIRS 129 STRG 146 VEST 145 CORRIDOR 144 UNIT N114 UNIT N112 UNIT N110 UNIT N113 UNIT N111 UNIT N109 UNIT N108 UNIT N106 UNIT N104 UNIT N102 UNIT N107 UNIT N105 UNIT N103 UNIT N101 1. ALL DIMENSIONS ARE TO INTERIOR FACE-OF-STUD (F.O.S.) UNLESS NOTED OTHERWISE. 2. CEILING HEIGHTS MEASURED FROM PLYWOOD OR CONCRETE - SEE SECTIONS 3. REFER TO ENLARGED PLANS FOR ALL UNIT DIMENSIONS, WINDOW TYPES, DOORS AND WALLS. 4. REFER TO ENLARGED PLANS FOR ALL DECKS/PATIOS. 5. COORDINATE WITH ALL ENLARGED PLANS FOR ADDITIONAL INFORMATION AND DETAILS. 6. ALL TOPPING SLABS MUST BE POURED AFTER ROOF IS COMPLETE AND BUILDING IS DRIED IN. 7. SEE SHEET A002 FOR PROJECT GENERAL NOTES AND SHEET A003 FOR PROJECT KEYNOTES. REVIEW ALL NOTES PRIOR TO CONSTRUCTION. 8. COORDINATE WITH STRUCTURAL FRAMING PLANS AND SHEAR WALL PLANS FOR LOCATIONS OF COLUMNS, BEAMS, SHEAR WALLS, ETC. 9. COORDINATE WITH BUILDER/OWNER FOR ALL INTERIOR FINISHES 10. COORDINATE WITH ELECTRICAL DRAWINGS FOR ALL LIGHTING, POWER AND DATA REQUIREMENTS. 11. ALL EXTERIOR WALLS ARE ASSUMED TO BE 2X6 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE. 12. ALL INTERIOR WALLS ARE ASSUMED TO BE 2X4 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE. 13. ALL ROOF TRUSSES TO HAVE RAISED ENERGY HEEL CONSTRUCTION TO ALLOW FOR FULL DEPTH INSULATION OVER EXTERIOR WALLS (COORDINATE INSULATION REQUIREMENTS WITH RESCHECKS). FLOOR PLAN GENERAL NOTES FLOOR PLAN KEYNOTES PROJECT NO. SHEET TITLE:Plot Date:Architecture Interior Design Landscape Architecture Land Planning Construction Management 5151 South 900 East, Suite 200 Salt Lake City, Ut 84117 ph. 801.269.0055 fax 801.269.1425 www.thinkaec.com The designs shown and described herein including all technical drawings, graphic representation & models thereof, are the copyrighted work of Think Architecture, Inc. and connot be copied, duplicated, or commercially exploited in whole or in part without the sole and express written permission from THINK Architecture, Inc. These drawings are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors, and office personnel only in accordance with this notice. SHEET NUMBER: REVISIONS: DATE: BUILDING KEY LEGEND AREA C 1/7/2020 3:41:15 PMINGLEWOOD PLACE - SENIOR LIVING3250 E VICTORY RDMERIDIAN IDAHOJan 7, 2020 18077 LEVEL 1 FLOOR PLAN A101C ANNEXATION SUBMITTAL1/8" = 1'-0"A101C LEVEL 1C - FLOOR PLAN 1 SHELVES15" R&SKOHLERW.C. W/D 15" R&S15" R&S WASH/DRYERKOHLERW.C.RANGE DW15" R&S15" R&SKOHLER W.C.SHELVES15" R&SKOHLER W.C. W/D15" R&S15" R&SSHELVES15" R&SKOHLER W.C. W/D 15" R&S15" R&SWASH/DRYERKOHLERW.C.RANGEDW 15" R&S15" R&S KOHLERW.C.W/DSHELVES15" R&SDWW.C.W/DSHELVES15" R&SDWW.C.SHELVES15" R&SDWW/DSHELVES15" R&SDWW.C.W/DSHELVES15" R&SDWW.C.W/DSHELVES15" R&SDWW.C.W/DSHELVES15" R&SDWW.C.W/DSHELVES15" R&SDWW.C.A A F F A206 4 A202 1 A203 3 A202 2 A202 3 A206 3 A206 1 A203 1 A203 2 2 A301A 2 A301A 1 A301A 1 A301A 1 A302A 1 A302A 2 A302A 2 A302A 1 A301B 1 1 C C B B 2 A301B BA 1 A306A 2 A306A A306A 5 D D 140'-8 1/4" 10'-2 3/4"3'-10 3/4"2'-6"3'-8"3'-8"2'-6"2'-6"7'-11"2'-6"9'-0"2'-6"2'-6"4'-3"4'-0"2'-6"4'-1 1/4"5'-10 3/4"2'-6"2'-6"5'-4"5'-4"2'-6"2'-6"5'-8"5'-8"2'-6"2'-6"5'-6 3/4"4'-1 1/4"2'-6"4'-0"6'-9"2'-6"4'-1 3/4" 133'-9 1/8" 1'-1 1/4"5'-3 3/4"2'-6"10'-5"2'-6"3'-8"3'-8"2'-6"3'-5 1/4"5'-10 3/4"2'-6"2'-6"5'-4"5'-4"2'-6"2'-6"5'-10 3/4"4'-1 1/4"2'-6"4'-0"6'-9"2'-6"3'-11"5'-8"2'-6"2'-6"5'-4"5'-4"2'-6"2'-6"16'-1 1/8"58'-0"2 A305B A A A B B A A A B A A A A B A A B A A B A A A B A ABAABAAB AA ABAABA AA ABAA 2'-0"2'-0"2'-0"2'-0"- --- 10'-2 3/4"10'-0 3/4"37'-4"10'-7 1/4"48'-5 1/2"10'-7 1/4"13'-4 3/4" 1'-1 1/4"24'-4 3/4"9'-7 1/4"32'-5 1/2"10'-7 1/4"56'-0 5/8"2'-0"4'-8"6'-4"16'-6"2'-11 1/2"25'-6 1/2"A 51'-4"4'-8"2'-0"- --- UNIT A202 UNIT A204 UNIT A206 UNIT A208 UNIT A210 UNIT A212 UNIT A201 UNIT A203 UNIT A205 UNIT A207 UNIT A209 UNIT A211 MECH 204 STAIRS 219 1. ALL DIMENSIONS ARE TO INTERIOR FACE-OF-STUD (F.O.S.) UNLESS NOTED OTHERWISE. 2. CEILING HEIGHTS MEASURED FROM PLYWOOD OR CONCRETE - SEE SECTIONS 3. REFER TO ENLARGED PLANS FOR ALL UNIT DIMENSIONS, WINDOW TYPES, DOORS AND WALLS. 4. REFER TO ENLARGED PLANS FOR ALL DECKS/PATIOS. 5. COORDINATE WITH ALL ENLARGED PLANS FOR ADDITIONAL INFORMATION AND DETAILS. 6. ALL TOPPING SLABS MUST BE POURED AFTER ROOF IS COMPLETE AND BUILDING IS DRIED IN. 7. SEE SHEET A002 FOR PROJECT GENERAL NOTES AND SHEET A003 FOR PROJECT KEYNOTES. REVIEW ALL NOTES PRI OR TO CONSTRUCTION. 8. COORDINATE WITH STRUCTURAL FRAMING PLANS AND SHEAR WALL PLANS FOR LOCATIONS OF COLUMNS, BEAMS, SHEAR WALLS, ETC. 9. COORDINATE WITH BUILDER/OWNER FOR ALL INTERIOR FINISHES 10. COORDINATE WITH ELECTRICAL DRAWINGS FOR ALL LI GHTING, POWER AND DATA REQUIREMENTS. 11. ALL EXTERIOR WALLS ARE ASSUMED TO BE 2X6 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE. 12. ALL INTERIOR WALLS ARE ASSUMED TO BE 2X4 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE. 13. ALL ROOF TRUSSES TO HAVE RAISED ENERGY HEEL CONSTRUCTION TO ALLOW FOR FULL DEPTH INSULATION OVER EXTERIOR WALLS (COORDINATE INSULATION REQUIREMENTS WITH RESCHECKS). FLOOR PLAN GENERAL NOTES FLOOR PLAN KEYNOTES HATCH PATTERN DESCRIPTION FLOOR PLAN LEGEND POURED IN PLACE CONCRETE WALL CARPET FINISH HATCH PATTERN DESCRIPTION WOOD STUD WALL STONE VENEER CMU BLOCK WALL METAL STUD WALL TILE FINISH EXTERIOR CONCRETE SLABS PROJECT NO. SHEET TITLE:Plot Date:Architecture Interior Design Landscape Architecture Land Planning Construction Management 5151 South 900 East, Suite 200 Salt Lake City, Ut 84117 ph. 801.269.0055 fax 801.269.1425 www.thinkaec.com The designs shown and described herein including all technical drawings, graphic representation & models thereof, are the copyrighted work of Think Architecture, Inc. and connot be copied, duplicated, or commercially exploited in whole or in part without the sole and express written permission from THINK Architecture, Inc. These drawings are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors, and office personnel only in accordance with this notice. SHEET NUMBER: REVISIONS: DATE: BUILDING KEY LEGEND AREA A 1/7/2020 3:41:21 PMINGLEWOOD PLACE - SENIOR LIVING3250 E VICTORY RDMERIDIAN IDAHOJan 7, 2020 18077 LEVEL 2 FLOOR PLAN A102A ANNEXATION SUBMITTAL1/8" = 1'-0"A102A LEVEL 2A - FLOOR PLAN 1 KEYNOTE INSTRUCTIONAL SHELVES15" R&SW.C. KOHLER W.C. KOHLER W.C. KOHLER W.C.KOHLERW.C.KOHLERW.C.KOHLERW.C.U.C.FRIDGEKOHLERW.C.U.C.FRIDGEW/DSHELVES15" R&SDWW.C.W/DSHELVES15" R&SDWW.C.W/DSHELVES15" R&SDWW.C.W/DSHELVES15" R&SDWW.C.W/DSHELVES15" R&SDWW.C.W/DSHELVES15" R&SDWW.C.UP HATCH PATTERN DESCRIPTION FLOOR PLAN LEGEND POURED IN PLACE CONCRETE WALL CARPET FINISH HATCH PATTERN DESCRIPTION WOOD STUD WALL STONE VENEER CMU BLOCK WALL METAL STUD WALL TILE FINISH EXTERIOR CONCRETE SLABS 1. ALL DIMENSIONS ARE TO INTERIOR FACE-OF-STUD (F.O.S.) UNLESS NOTED OTHERWISE. 2. CEILING HEIGHTS MEASURED FROM PLYWOOD OR CONCRETE - SEE SECTIONS 3. REFER TO ENLARGED PLANS FOR ALL UNIT DIMENSIONS, WINDOW TYPES, DOORS AND WALLS. 4. REFER TO ENLARGED PLANS FOR ALL DECKS/PATIOS. 5. COORDINATE WITH ALL ENLARGED PLANS FOR ADDITIONAL INFORMATION AND DETAILS. 6. ALL TOPPING SLABS MUST BE POURED AFTER ROOF IS COMPLETE AND BUILDING IS DRIED IN. 7. SEE SHEET A002 FOR PROJECT GENERAL NOTES AND SHEET A003 FOR PROJECT KEYNOTES. REVIEW ALL NOTES PRIOR TO CONSTRUCTION. 8. COORDINATE WITH STRUCTURAL FRAMING PLANS AND SHEAR WALL PLANS FOR LOCATIONS OF COLUMNS, BEAMS, SHEAR WALLS, ETC. 9. COORDINATE WITH BUILDER/OWNER FOR ALL INTERIOR FINISHES 10. COORDINATE WITH ELECTRICAL DRAWINGS FOR ALL LIGHTING, POWER AND DATA REQUIREMENTS. 11. ALL EXTERIOR WALLS ARE ASSUMED TO BE 2X6 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE. 12. ALL INTERIOR WALLS ARE ASSUMED TO BE 2X4 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE. 13. ALL ROOF TRUSSES TO HAVE RAISED ENERGY HEEL CONSTRUCTION TO ALLOW FOR FULL DEPTH INSULATION OVER EXTERIOR WALLS (COORDINATE INSULATION REQUIREMENTS WITH RESCHECKS). FLOOR PLAN GENERAL NOTES FLOOR PLAN KEYNOTES 3 3 4 4 1 A304B A206 3 A206 1 2 A305A 2 A305A 1 A305A 1 A305A B H CBA 2 A307A A307A 5 1 A305B 1 A305B 2 A305B 1 A304C 2 A304C A B A A B A A B A A B A A B A A B A A A A A A A A A A A A A A A A A A A 30'-9 7/8"20'-0"44'-6 7/8" 3'-4 59/128"4'-0"5'-11 107/256"4'-0"5'-11 107/256"4'-0"4'-0"6'-10 1/2"4'-0"6'-10 1/2"4'-0"6'-10 1/2"4'-0"4'-3"3'-6"4'-6"3'-6"3'-8 1/2"95'-2 3/8"MATCHLINEMATCHLINE2 A303C - --- - --- UNIT A214 UNIT A216 UNIT A218 UNIT A220 UNIT A222 UNIT A224 DATA CENTER 206 MAID 207 FITNESS 203 CORRIDOR 208 SALON 222 MEN 218 WOMENS 217 SHWER 216 SHWER 219 NURSE 215 FILES 214 MEDS 213 DR 211 SENSORY 221 SALES 222 G.M. 224 BUSINESS 223 GYM EQUIP. 202 DISCOVERY 220 LOUNGE 212 212 CORRIDOR 225 CORRIDOR 201 PROJECT NO. SHEET TITLE:Plot Date:Architecture Interior Design Landscape Architecture Land Planning Construction Management 5151 South 900 East, Suite 200 Salt Lake City, Ut 84117 ph. 801.269.0055 fax 801.269.1425 www.thinkaec.com The designs shown and described herein including all technical drawings, graphic representation & models thereof, are the copyrighted work of Think Architecture, Inc. and connot be copied, duplicated, or commercially exploited in whole or in part without the sole and express written permission from THINK Architecture, Inc. These drawings are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors, and office personnel only in accordance with this notice. SHEET NUMBER: REVISIONS: DATE: BUILDING KEY LEGEND AREA B 1/7/2020 3:41:27 PMINGLEWOOD PLACE - SENIOR LIVING3250 E VICTORY RDMERIDIAN IDAHOJan 7, 2020 18077 LEVEL 2 FLOOR PLAN A102B ANNEXATION SUBMITTALKEYNOTE INSTRUCTIONAL 1/8" = 1'-0"A102B LEVEL 2B - FLOOR PLAN 1 RANGEDWW/D W.C.RANGEDWW/DW.C.RANGEDWW/DW.C.RANGEDWW/DW.C.RANGEDWW/DW.C.SHELVES15" R&SW/DW.C.15" R&S 15" R&SW.C.RANGEDWSHELVES15" R&SW/DW.C.15" R&S15" R&SW.C.RANGEDWSHELVES15" R&SW/DW.C.15" R&S15" R&SW.C.RANGEDWRANGEDWW/D W.C.RANGEDWW/D W.C.RANGEDWW/D W.C.RANGEDWW/DW.C.SHELVES15" R&SDWSHELVES15" R&S W/D KOHLERW.C.15" R&S15" R&S RANGEDWSHELVES15" R&SW/D KOHLERW.C.15" R&S15" R&SRANGEDWSHELVES15" R&S W/D KOHLERW.C.15" R&S15" R&S RANGEDWSHELVES15" R&SW/D KOHLERW.C.15" R&S15" R&SRANGEDWDNUP 4 4 A A F J J 1 A304B 1 A304B A2062 2 A304B 2 A304B A204 3 A2042 A204 1 A205 3 A2052 A205 1 2 A303A 2 A303A 1 A303A 1 A303A 2 A304A 2 A304A 1 A304A 1 A304A CB 1 A307A2 A307A A308A 5 A309A 6 - --- 5 6 7 7 8 8 D63'-0"4'-0"23'-6 1/2"3'-7"3'-10 1/2"18'-10 1/2"5'-1 1/2"4'-0"1 A303B 112'-10 1/4" 101'-10"10'-2 3/4" 9'-4 3/4"30'-0 5/8"9'-2 1/8"8'-8 5/8"15'-3 3/8"6'-0 3/4"23'-11 1/4" 4'-10 3/4"4'-6"7'-10"2'-6"9'-4"2'-6"7'-10 5/8"4'-5 3/8"4'-8 3/4"4'-3 1/4"4'-5 3/8"7'-10 5/8"2'-6"4'-10 3/4"3'-0 3/4"3'-0"5'-11"2'-6"6'-4"2'-6"2'-6"4'-2 1/4" 123'-9 1/4" 10'-11"9'-4 3/4"30'-0"8'-9 1/4"23'-11 1/4"14'-0 1/2"14'-0"12'-8 1/2" 10'-11"4'-10 3/4"4'-6"7'-10"2'-6"9'-4"2'-6"7'-10"4'-6"4'-3 1/4"4'-2 1/4"2'-6"2'-6"6'-4"2'-6"5'-11"3'-0"5'-9 1/2"2'-6"8'-3"3'-0"5'-6"6'-1"6'-7 1/2"63'-0"4'-0"31'-0"19'-4"8'-8"27'-6"3'-6"1 A303C 1 A304C 2 A304C A A A A A B A A A A B A A BA AAABAAAAA A A A A A A A A A B A A A A A A A B A A A C C A B4'-4"4'-8"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"4'-0"11'-0" 5 1/2" 9'-2 3/4"7'-4 1/2"2'-6"4'-8"4'-8"2'-6"7'-10"4'-6"4'-6" 2 3/4" 3'-8 3/4"2'-6"2'-6"6'-4"2'-6"5'-11"8'-9 1/2"2'-6"3'-2 1/2"13'-6 1/2"6'-1" 11'-0"9'-8 1/4"29'-6 1/2"9'-2 3/4"23'-5 3/4"14'-6"13'-6 1/2" 112'-5 1/2" 10'-8 3/8" 5 1/2" 4'-5 1/4"2'-6"7'-10"4'-6"4'-2 1/4"5'-1 3/4"2'-6"7'-8"4'-6"4'-3 1/4"4'-4 1/4"2'-6"2'-6"6'-4"2'-6"5'-9"14'-0 1/2"14'-0"6'-1"6'-4 3/4" 25'-11 1/8"24'-0"8'-9 1/4"23'-11 1/4"14'-0 1/2"14'-0"12'-5 3/4"10'-3 1/4" 4'-11 5/16" - ---4'-1 1/16"2'-6"8'-0 3/4"2'-6"2'-6"2'-6"2'-6"8'-0 3/4"2'-6"4'-1 1/2"39'-4 1/16"2 A303C - --- - --- - --- - --- STAIRS 226 STRG 227 STRG 228 UNIT N209 UNIT N211 UNIT N213 UNIT N215 UNIT N216 UNIT N214 UNIT N212 UNIT N210 UNIT N201 UNIT N203 UNIT N205 UNIT N207 UNIT N208 UNIT N202 UNIT N204 UNIT N206 CORRIDOR 243 CORRIDOR 209 MAID 210 1. ALL DIMENSIONS ARE TO INTERIOR FACE-OF-STUD (F.O.S.) UNLESS NOTED OTHERWISE. 2. CEILING HEIGHTS MEASURED FROM PLYWOOD OR CONCRETE - SEE SECTIONS 3. REFER TO ENLARGED PLANS FOR ALL UNIT DIMENSIONS, WINDOW TYPES, DOORS AND WALLS. 4. REFER TO ENLARGED PLANS FOR ALL DECKS/PATIOS. 5. COORDINATE WITH ALL ENLARGED PLANS FOR ADDITIONAL INFORMATION AND DETAILS. 6. ALL TOPPING SLABS MUST BE POURED AFTER ROOF IS COMPLETE AND BUILDING IS DRIED IN. 7. SEE SHEET A002 FOR PROJECT GENERAL NOTES AND SHEET A003 FOR PROJECT KEYNOTES. REVIEW ALL NOTES PRIOR TO CONSTRUCTION. 8. COORDINATE WITH STRUCTURAL FRAMING PLANS AND SHEAR WALL PLANS FOR LOCATIONS OF COLUMNS, BEAMS, SHEAR WALLS, ETC. 9. COORDINATE WITH BUILDER/OWNER FOR ALL INTERIOR FINISHES 10. COORDINATE WITH ELECTRICAL DRAWINGS FOR ALL LIGHTING, POWER AND DATA REQUIREMENTS. 11. ALL EXTERIOR WALLS ARE ASSUMED TO BE 2X6 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE. 12. ALL INTERIOR WALLS ARE ASSUMED TO BE 2X4 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE. 13. ALL ROOF TRUSSES TO HAVE RAISED ENERGY HEEL CONSTRUCTION TO ALLOW FOR FULL DEPTH INSULATION OVER EXTERIOR WALLS (COORDINATE INSULATION REQUIREMENTS WITH RESCHECKS). FLOOR PLAN GENERAL NOTES FLOOR PLAN KEYNOTES PROJECT NO. SHEET TITLE:Plot Date:Architecture Interior Design Landscape Architecture Land Planning Construction Management 5151 South 900 East, Suite 200 Salt Lake City, Ut 84117 ph. 801.269.0055 fax 801.269.1425 www.thinkaec.com The designs shown and described herein including all technical drawings, graphic representation & models thereof, are the copyrighted work of Think Architecture, Inc. and connot be copied, duplicated, or commercially exploited in whole or in part without the sole and express written permission from THINK Architecture, Inc. These drawings are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors, and office personnel only in accordance with this notice. SHEET NUMBER: REVISIONS: DATE: BUILDING KEY LEGEND AREA C 1/7/2020 3:41:34 PMINGLEWOOD PLACE - SENIOR LIVING3250 E VICTORY RDMERIDIAN IDAHOJan 7, 2020 18077 LEVEL 2 FLOOR PLAN A102C ANNEXATION SUBMITTAL1/8" = 1'-0"A102C LEVEL 2C - FLOOR PLAN 1 RANGEDWW/D W.C.RANGEDWW/DW.C.RANGEDWW/DW.C.RANGEDWW/DW.C.RANGEDWW/DW.C.SHELVES15" R&SW/DW.C.15" R&S 15" R&SW.C.RANGEDWSHELVES15" R&SW/DW.C.15" R&S15" R&SW.C.RANGEDWSHELVES15" R&SW/DW.C.15" R&S15" R&SW.C.RANGEDWRANGEDWW/D W.C.RANGEDWW/D W.C.RANGEDWW/D W.C.RANGEDWW/DW.C. SHELVES15" R&S W/D KOHLERW.C.15" R&S15" R&S RANGEDWSHELVES15" R&SW/D KOHLERW.C.15" R&S15" R&SRANGEDWSHELVES15" R&S W/D KOHLERW.C.15" R&S15" R&S RANGEDWSHELVES15" R&SW/D KOHLERW.C.15" R&S15" R&SRANGEDWDN A2013 4 4 A A D2103 F F J J 1 A304B 1 A304B 2 -D2141D2171 2A2062 2 A304B 2 A304B A204 3 A2042 A204 1 A205 3 A2052 A205 1 2 A303A 1 A303A 2 A304A1 A304A B B 1 A307A2 A307A 4'-6"A308A 6 A309A 5 A307A 6 - --- 5 5 6 6 7 7 8 8 D D 1 A303B 2 A305B 1 A303C 1 A304C 2 A304C 23'-6 1/2"26'-9 1/2"4'-8"4'-0"63'-0"31'-3"31'-9"102'-7 1/2"10'-2 3/4" 4'-10 3/4"4'-6"7'-10"2'-6"9'-4"2'-6"7'-10"8'-9 1/4"4'-8 3/4"4'-6"7'-10"2'-6"4'-10 3/4"3'-0 3/4"3'-0"5'-11"2'-6"6'-4"2'-6"2'-6"4'-2 1/4"10'-2 3/4"4'-0"4'-0"4'-0"4'-0"4'-0"112'-5 1/2" 10'-8 3/8"4'-10 3/4"2'-6"7'-10"4'-6"9'-2"2'-6"7'-10"4'-6"4'-3 1/4"4'-2 1/4"2'-6"2'-6"6'-4"2'-6"5'-11"3'-0"5'-9 1/2"2'-6"2'-9"14'-0"6'-1"6'-4 3/4" 10'-8 3/8"15'-2 3/4"8'-9 1/4"15'-2 3/4"8'-9 1/4"23'-11 1/4"14'-0 1/2"14'-0" 4'-8 3/4"4'-6"7'-10"2'-6"9'-4"2'-6"7'-10"4'-6"4'-3 1/4"4'-2 1/4"2'-6"2'-6"6'-4"2'-6"5'-11"3'-0"5'-9 1/2"2'-6"2'-9"14'-0"4'-10"2'-6"5'-1 3/4" 112'-5 1/2" 12'-5 3/4" 112'-10 1/4" 4'-10 3/4"4'-6"7'-10"2'-6"9'-4"2'-6"7'-10"4'-6"4'-3 1/4"4'-2 1/4"2'-6"2'-6"6'-4"2'-6"5'-11"3'-0"5'-9 1/2"2'-6"2'-9"5'-6"3'-0"5'-6"6'-1"6'-7 1/2" - --- 2 A303C 11'-0" 0" 9'-2 3/4"30'-0"8'-9 1/4"23'-11 1/4"14'-0 1/2"14'-0"12'-5 3/4" 9'-4 3/4"30'-0"8'-9 1/4"9'-2 3/4"15'-2 3/4"6'-0 3/4"23'-11 1/4"10'-2 3/4"63'-0"4'-0"50'-4"8'-8"9'-0"9'-4 3/4"30'-0"8'-9 1/4"23'-11 1/4"14'-0 1/2"14'-0"12'-8 1/2" - --- - --- - --- - --- UNIT N316 UNIT N301 UNIT N303 UNIT N305 UNIT N307 UNIT N302 UNIT N304 UNIT N306 UNIT N308 UNIT N309 UNIT N311 UNIT N313 UNIT N315 UNIT N314 UNIT N312 UNIT N310 1. ALL DIMENSIONS ARE TO INTERIOR FACE-OF-STUD (F.O.S.) UNLESS NOTED OTHERWISE. 2. CEILING HEIGHTS MEASURED FROM PLYWOOD OR CONCRETE - SEE SECTIONS 3. REFER TO ENLARGED PLANS FOR ALL UNIT DIMENSIONS, WINDOW TYPES, DOORS AND WALLS. 4. REFER TO ENLARGED PLANS FOR ALL DECKS/PATIOS. 5. COORDINATE WITH ALL ENLARGED PLANS FOR ADDITIONAL INFORMATION AND DETAILS. 6. ALL TOPPING SLABS MUST BE POURED AFTER ROOF IS COMPLETE AND BUILDING IS DRIED IN. 7. SEE SHEET A002 FOR PROJECT GENERAL NOTES AND SHEET A003 FOR PROJECT KEYNOTES. REVIEW ALL NOTES PRIOR TO CONSTRUCTION. 8. COORDINATE WITH STRUCTURAL FRAMING PLANS AND SHEAR WALL PLANS FOR LOCATIONS OF COLUMNS, BEAMS, SHEAR WALLS, ETC. 9. COORDINATE WITH BUILDER/OWNER FOR ALL INTERIOR FINISHES 10. COORDINATE WITH ELECTRICAL DRAWINGS FOR ALL LI GHTING, POWER AND DATA REQUIREMENTS. 11. ALL EXTERIOR WALLS ARE ASSUMED TO BE 2X6 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE. 12. ALL INTERIOR WALLS ARE ASSUMED TO BE 2X4 STUD WALLS UNLESS SHOWN/NOTED OTHERWISE. 13. ALL ROOF TRUSSES TO HAVE RAISED ENERGY HEEL CONSTRUCTION TO ALLOW FOR FULL DEPTH INSULATION OVER EXTERIOR WALLS (COORDINATE INSULATION REQUIREMENTS WITH RESCHECKS). FLOOR PLAN GENERAL NOTES FLOOR PLAN KEYNOTES PROJECT NO. SHEET TITLE:Plot Date:Architecture Interior Design Landscape Architecture Land Planning Construction Management 5151 South 900 East, Suite 200 Salt Lake City, Ut 84117 ph. 801.269.0055 fax 801.269.1425 www.thinkaec.com The designs shown and described herein including all technical drawings, graphic representation & models thereof, are the copyrighted work of Think Architecture, Inc. and connot be copied, duplicated, or commercially exploited in whole or in part without the sole and express written permission from THINK Architecture, Inc. These drawings are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors, and office personnel only in accordance with this notice. SHEET NUMBER: REVISIONS: DATE: BUILDING KEY LEGEND AREA C 1/7/2020 3:41:41 PMINGLEWOOD PLACE - SENIOR LIVING3250 E VICTORY RDMERIDIAN IDAHOJan 7, 2020 18077 LEVEL 3 FLOOR PLAN A102D ANNEXATION SUBMITTAL1/8" = 1'-0"A102D LEVEL 3 - FLOOR PLAN 1 KEYNOTE INSTRUCTIONAL Key Value Keynote Text NOTE: REFER TO MATERIAL SPECIFICATIONS DOCUMENT FOR DETAILED INFORMATION REGARDING EACH FINISH MATERIAL HATCH PATTERN DESCRIPTION ELEVATION/ SECTION MATERIAL LEGEND WOOD CEDAR SHAKE ROOFING SYSTEM ELEVATION/ SECTION KEYNOTES LAP SEAM COPPER ROOFING SYSTEM SINGLE PLY ROOFING MEMBRANE SYSTEM 2X10 CEDAR CHANNEL LAP VERTICAL SIDING SYSTEM WITH SQUARE EDGES EXTERIOR STONE VENEER LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 1 -T.O. SLAB 100'-0" LEVEL 1 -T.O. SLAB 100'-0" UPPER ROOF BEARING 131'-4 7/8" UPPER ROOF BEARING 131'-4 7/8" 3 4 LEVEL 3 -T.O. PLY 122'-3 3/4" LEVEL 3 -T.O. PLY 122'-3 3/4"LEVEL 3 BEARING 120'-9" T.O. CHIMNEY 137'-7 5/128" T.O. CHIMNEY 137'-7 5/128" 1 2 56 78 MEMORY CARE ROOF BEARING 110'-1 1/8" MEMORY CARE ROOF BEARING 110'-1 1/8" AL WING ROOF BEARING 120'-9" AL WING ROOF BEARING 120'-9" COMMON AREA ROOF BEARING 121'-9" COMMON AREA ROOF BEARING 121'-9" LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 1 -T.O. SLAB 100'-0" LEVEL 1 -T.O. SLAB 100'-0" UPPER ROOF BEARING 131'-4 7/8" UPPER ROOF BEARING 131'-4 7/8" IA LEVEL 3 -T.O. PLY 122'-3 3/4" LEVEL 3 -T.O. PLY 122'-3 3/4"LEVEL 3 BEARING 120'-9" F J T.O. CHIMNEY 137'-7 5/128" T.O. CHIMNEY 137'-7 5/128" C EB HDG MEMORY CARE ROOF BEARING 110'-1 1/8" MEMORY CARE ROOF BEARING 110'-1 1/8" AL WING ROOF BEARING 120'-9" AL WING ROOF BEARING 120'-9" COMMON AREA ROOF BEARING 121'-9" COMMON AREA ROOF BEARING 121'-9" LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 1 -T.O. SLAB 100'-0" LEVEL 1 -T.O. SLAB 100'-0" UPPER ROOF BEARING 131'-4 7/8" UPPER ROOF BEARING 131'-4 7/8" I A LEVEL 3 -T.O. PLY 122'-3 3/4" LEVEL 3 -T.O. PLY 122'-3 3/4"LEVEL 3 BEARING 120'-9" FJ 1 A304B T.O. CHIMNEY 137'-7 5/128" T.O. CHIMNEY 137'-7 5/128" CE BHDG MEMORY CARE ROOF BEARING 110'-1 1/8" MEMORY CARE ROOF BEARING 110'-1 1/8" AL WING ROOF BEARING 120'-9" AL WING ROOF BEARING 120'-9" COMMON AREA ROOF BEARING 121'-9" COMMON AREA ROOF BEARING 121'-9" LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 1 -T.O. SLAB 100'-0" LEVEL 1 -T.O. SLAB 100'-0" UPPER ROOF BEARING 131'-4 7/8" UPPER ROOF BEARING 131'-4 7/8" 34 LEVEL 3 -T.O. PLY 122'-3 3/4" LEVEL 3 -T.O. PLY 122'-3 3/4"LEVEL 3 BEARING 120'-9" T.O. CHIMNEY 137'-7 5/128" T.O. CHIMNEY 137'-7 5/128" 125678 MEMORY CARE ROOF BEARING 110'-1 1/8" MEMORY CARE ROOF BEARING 110'-1 1/8" AL WING ROOF BEARING 120'-9" AL WING ROOF BEARING 120'-9" COMMON AREA ROOF BEARING 121'-9" COMMON AREA ROOF BEARING 121'-9" PROJECT NO. SHEET TITLE:Plot Date:Architecture Interior Design Landscape Architecture Land Planning Construction Management 5151 South 900 East, Suite 200 Salt Lake City, Ut 84117 ph. 801.269.0055 fax 801.269.1425 www.thinkaec.com The designs shown and described herein including all technical drawings, graphic representation & models thereof, are the copyrighted work of Think Architecture, Inc. and connot be copied, duplicated, or commercially exploited in whole or in part without the sole and express written permission from THINK Architecture, Inc. These drawings are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors, and office personnel only in accordance with this notice. SHEET NUMBER: REVISIONS: DATE:1/7/2020 3:42:07 PMINGLEWOOD PLACE - SENIOR LIVING3250 E VICTORY RDMERIDIAN IDAHOJan 7, 2020 18077 OVERALL EXTERIOR ELEVATIONS A201 ANNEXATION SUBMITTAL1/16" = 1'-0"A201 EAST ELEVATION 1 1/16" = 1'-0"A201 SOUTH ELEVATION 2 KEYNOTE INSTRUCTIONAL 1/16" = 1'-0"A201 NORTH ELEVATION 3 1/16" = 1'-0"A201 WEST ELEVATION 4 NOTE: REFER TO MATERIAL SPECIFICATIONS DOCUMENT FOR DETAILED INFORMATION REGARDING EACH FINISH MATERIAL HATCH PATTERN DESCRIPTION ELEVATION/ SECTION MATERIAL LEGEND WOOD CEDAR SHAKE ROOFING SYSTEM ELEVATION/ SECTION KEYNOTES LAP SEAM COPPER ROOFING SYSTEM SINGLE PLY ROOFING MEMBRANE SYSTEM 2X10 CEDAR CHANNEL LAP VERTICAL SIDING SYSTEM WITH SQUARE EDGES EXTERIOR STONE VENEERLEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 1 -T.O. SLAB 100'-0" LEVEL 1 -T.O. SLAB 100'-0" UPPER ROOF BEARING 131'-4 7/8" UPPER ROOF BEARING 131'-4 7/8" LEVEL 3 -T.O. PLY 122'-3 3/4" LEVEL 3 -T.O. PLY 122'-3 3/4"LEVEL 3 BEARING 120'-9" T.O. CHIMNEY 137'-7 5/128" 2 A301A 1 A301A 1 A306A 2 A306A - --- MEMORY CARE ROOF BEARING 110'-1 1/8" MEMORY CARE ROOF BEARING 110'-1 1/8" AL WING ROOF BEARING 120'-9" AL WING ROOF BEARING 120'-9" COMMON AREA ROOF BEARING 121'-9" COMMON AREA ROOF BEARING 121'-9" LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 1 -T.O. SLAB 100'-0" LEVEL 1 -T.O. SLAB 100'-0" UPPER ROOF BEARING 131'-4 7/8" UPPER ROOF BEARING 131'-4 7/8" A LEVEL 3 -T.O. PLY 122'-3 3/4" LEVEL 3 -T.O. PLY 122'-3 3/4"LEVEL 3 BEARING 120'-9" T.O. CHIMNEY 137'-7 5/128" 1 A301B CB 2 A301B MEMORY CARE ROOF BEARING 110'-1 1/8" MEMORY CARE ROOF BEARING 110'-1 1/8" AL WING ROOF BEARING 120'-9" AL WING ROOF BEARING 120'-9" COMMON AREA ROOF BEARING 121'-9" COMMON AREA ROOF BEARING 121'-9" LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 1 -T.O. SLAB 100'-0" LEVEL 1 -T.O. SLAB 100'-0" UPPER ROOF BEARING 131'-4 7/8" UPPER ROOF BEARING 131'-4 7/8" 3 LEVEL 3 -T.O. PLY 122'-3 3/4" LEVEL 3 -T.O. PLY 122'-3 3/4"LEVEL 3 BEARING 120'-9" T.O. CHIMNEY 137'-7 5/128" 2 A301A 1 A301A 1 1 A306A 2 A306A 2- --- MEMORY CARE ROOF BEARING 110'-1 1/8" MEMORY CARE ROOF BEARING 110'-1 1/8" AL WING ROOF BEARING 120'-9" AL WING ROOF BEARING 120'-9" COMMON AREA ROOF BEARING 121'-9" COMMON AREA ROOF BEARING 121'-9" PROJECT NO. SHEET TITLE:Plot Date:Architecture Interior Design Landscape Architecture Land Planning Construction Management 5151 South 900 East, Suite 200 Salt Lake City, Ut 84117 ph. 801.269.0055 fax 801.269.1425 www.thinkaec.com The designs shown and described herein including all technical drawings, graphic representation & models thereof, are the copyrighted work of Think Architecture, Inc. and connot be copied, duplicated, or commercially exploited in whole or in part without the sole and express written permission from THINK Architecture, Inc. These drawings are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors, and office personnel only in accordance with this notice. SHEET NUMBER: REVISIONS: DATE:1/7/2020 3:42:14 PMINGLEWOOD PLACE - SENIOR LIVING3250 E VICTORY RDMERIDIAN IDAHOJan 7, 2020 18077 AL EXTERIOR ELEVATIONS A202 ANNEXATION SUBMITTALKEYNOTE INSTRUCTIONAL 1/8" = 1'-0"A202 AL EAST ELEVATION 1 1/8" = 1'-0"A202 AL SOUTH ELEVATION 2 1/8" = 1'-0"A202 AL WEST ELEVATION 3 NOTE: REFER TO MATERIAL SPECIFICATIONS DOCUMENT FOR DETAILED INFORMATION REGARDING EACH FINISH MATERIAL HATCH PATTERN DESCRIPTION ELEVATION/ SECTION MATERIAL LEGEND WOOD CEDAR SHAKE ROOFING SYSTEM ELEVATION/ SECTION KEYNOTES LAP SEAM COPPER ROOFING SYSTEM SINGLE PLY ROOFING MEMBRANE SYSTEM 2X10 CEDAR CHANNEL LAP VERTICAL SIDING SYSTEM WITH SQUARE EDGES EXTERIOR STONE VENEERLEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 1 -T.O. SLAB 100'-0" LEVEL 1 -T.O. SLAB 100'-0" UPPER ROOF BEARING 131'-4 7/8" UPPER ROOF BEARING 131'-4 7/8" LEVEL 3 -T.O. PLY 122'-3 3/4" LEVEL 3 -T.O. PLY 122'-3 3/4"LEVEL 3 BEARING 120'-9" T.O. CHIMNEY 137'-7 5/128" 1 A302A 2 A302A MEMORY CARE ROOF BEARING 110'-1 1/8" MEMORY CARE ROOF BEARING 110'-1 1/8" AL WING ROOF BEARING 120'-9" AL WING ROOF BEARING 120'-9" COMMON AREA ROOF BEARING 121'-9" COMMON AREA ROOF BEARING 121'-9" LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 1 -T.O. SLAB 100'-0" LEVEL 1 -T.O. SLAB 100'-0" I LEVEL 3 -T.O. PLY 122'-3 3/4" LEVEL 3 -T.O. PLY 122'-3 3/4"LEVEL 3 BEARING 120'-9" FE HG MEMORY CARE ROOF BEARING 110'-1 1/8" MEMORY CARE ROOF BEARING 110'-1 1/8" AL WING ROOF BEARING 120'-9" AL WING ROOF BEARING 120'-9" COMMON AREA ROOF BEARING 121'-9" COMMON AREA ROOF BEARING 121'-9" - --- LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 1 -T.O. SLAB 100'-0" UPPER ROOF BEARING 131'-4 7/8" LEVEL 3 -T.O. PLY 122'-3 3/4"LEVEL 3 BEARING 120'-9" T.O. CHIMNEY 137'-7 5/128" 1 A302A 2 A302A 2 MEMORY CARE ROOF BEARING 110'-1 1/8" AL WING ROOF BEARING 120'-9" COMMON AREA ROOF BEARING 121'-9" PROJECT NO. SHEET TITLE:Plot Date:Architecture Interior Design Landscape Architecture Land Planning Construction Management 5151 South 900 East, Suite 200 Salt Lake City, Ut 84117 ph. 801.269.0055 fax 801.269.1425 www.thinkaec.com The designs shown and described herein including all technical drawings, graphic representation & models thereof, are the copyrighted work of Think Architecture, Inc. and connot be copied, duplicated, or commercially exploited in whole or in part without the sole and express written permission from THINK Architecture, Inc. These drawings are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors, and office personnel only in accordance with this notice. SHEET NUMBER: REVISIONS: DATE:1/7/2020 3:42:21 PMINGLEWOOD PLACE - SENIOR LIVING3250 E VICTORY RDMERIDIAN IDAHOJan 7, 2020 18077 MC EXTERIOR ELEVATIONS A203 ANNEXATION SUBMITTAL1/8" = 1'-0"A203 MC EAST ELEVATION 1 1/8" = 1'-0"A203 MC SOUTH ELEVATION 2 1/8" = 1'-0"A203 MC WEST ELEVATION 3 KEYNOTE INSTRUCTIONAL NOTE: REFER TO MATERIAL SPECIFICATIONS DOCUMENT FOR DETAILED INFORMATION REGARDING EACH FINISH MATERIAL HATCH PATTERN DESCRIPTION ELEVATION/ SECTION MATERIAL LEGEND WOOD CEDAR SHAKE ROOFING SYSTEM ELEVATION/ SECTION KEYNOTES LAP SEAM COPPER ROOFING SYSTEM SINGLE PLY ROOFING MEMBRANE SYSTEM 2X10 CEDAR CHANNEL LAP VERTICAL SIDING SYSTEM WITH SQUARE EDGES EXTERIOR STONE VENEER LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 1 -T.O. SLAB 100'-0" UPPER ROOF BEARING 131'-4 7/8" LEVEL 3 -T.O. PLY 122'-3 3/4" LEVEL 3 BEARING 120'-9" T.O. CHIMNEY 137'-7 5/128" 2 A303A 1 A303A 1 A307A - --- 5 7 1 A303C MEMORY CARE ROOF BEARING 110'-1 1/8" AL WING ROOF BEARING 120'-9" COMMON AREA ROOF BEARING 121'-9" 2 A303C - --- - --- LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 1 -T.O. SLAB 100'-0" UPPER ROOF BEARING 131'-4 7/8" A LEVEL 3 -T.O. PLY 122'-3 3/4"LEVEL 3 BEARING 120'-9" T.O. CHIMNEY 137'-7 5/128" C B D 1 A303B MEMORY CARE ROOF BEARING 110'-1 1/8" AL WING ROOF BEARING 120'-9" COMMON AREA ROOF BEARING 121'-9" - --- - --- LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 1 -T.O. SLAB 100'-0" UPPER ROOF BEARING 131'-4 7/8" 4 LEVEL 3 -T.O. PLY 122'-3 3/4"LEVEL 3 BEARING 120'-9" T.O. CHIMNEY 137'-7 5/128" 2 A303A 1 A303A 1 A307A 2 A307A - --- 56 7 8 1 A303C MEMORY CARE ROOF BEARING 110'-1 1/8" AL WING ROOF BEARING 120'-9" COMMON AREA ROOF BEARING 121'-9" 2 A303C - ---21'-9"- --- PROJECT NO. SHEET TITLE:Plot Date:Architecture Interior Design Landscape Architecture Land Planning Construction Management 5151 South 900 East, Suite 200 Salt Lake City, Ut 84117 ph. 801.269.0055 fax 801.269.1425 www.thinkaec.com The designs shown and described herein including all technical drawings, graphic representation & models thereof, are the copyrighted work of Think Architecture, Inc. and connot be copied, duplicated, or commercially exploited in whole or in part without the sole and express written permission from THINK Architecture, Inc. These drawings are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors, and office personnel only in accordance with this notice. SHEET NUMBER: REVISIONS: DATE:1/7/2020 3:42:31 PMINGLEWOOD PLACE - SENIOR LIVING3250 E VICTORY RDMERIDIAN IDAHOJan 7, 2020 18077 IL1 EXTERIOR ELEVATIONS A204 ANNEXATION SUBMITTAL1/8" = 1'-0"A204 IL1 EAST ELEVATION 1 1/8" = 1'-0"A204 IL1 NORTH ELEVATION 2 1/8" = 1'-0"A204 IL1 WEST ELEVATION 3 KEYNOTE INSTRUCTIONAL NOTE: REFER TO MATERIAL SPECIFICATIONS DOCUMENT FOR DETAILED INFORMATION REGARDING EACH FINISH MATERIAL HATCH PATTERN DESCRIPTION ELEVATION/ SECTION MATERIAL LEGEND WOOD CEDAR SHAKE ROOFING SYSTEM ELEVATION/ SECTION KEYNOTES LAP SEAM COPPER ROOFING SYSTEM SINGLE PLY ROOFING MEMBRANE SYSTEM 2X10 CEDAR CHANNEL LAP VERTICAL SIDING SYSTEM WITH SQUARE EDGES EXTERIOR STONE VENEER LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 1 -T.O. SLAB 100'-0" UPPER ROOF BEARING 131'-4 7/8" 4 LEVEL 3 -T.O. PLY 122'-3 3/4"LEVEL 3 BEARING 120'-9" T.O. CHIMNEY 137'-7 5/128" 2 A304A 1 A304A 1 A307A 56 8 MEMORY CARE ROOF BEARING 110'-1 1/8" AL WING ROOF BEARING 120'-9" COMMON AREA ROOF BEARING 121'-9" - --- LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 1 -T.O. SLAB 100'-0" LEVEL 1 -T.O. SLAB 100'-0" UPPER ROOF BEARING 131'-4 7/8" UPPER ROOF BEARING 131'-4 7/8" I LEVEL 3 -T.O. PLY 122'-3 3/4" LEVEL 3 -T.O. PLY 122'-3 3/4"LEVEL 3 BEARING 120'-9" F J 1 A304B T.O. CHIMNEY 137'-7 5/128" 2 A304B G 1 A304C2 A304C MEMORY CARE ROOF BEARING 110'-1 1/8" MEMORY CARE ROOF BEARING 110'-1 1/8" AL WING ROOF BEARING 120'-9" AL WING ROOF BEARING 120'-9" COMMON AREA ROOF BEARING 121'-9" COMMON AREA ROOF BEARING 121'-9" - --- LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 2 -T.O. PLY 111'-7 7/8" LEVEL 1 -T.O. SLAB 100'-0" LEVEL 1 -T.O. SLAB 100'-0" UPPER ROOF BEARING 131'-4 7/8" UPPER ROOF BEARING 131'-4 7/8" LEVEL 3 -T.O. PLY 122'-3 3/4" LEVEL 3 -T.O. PLY 122'-3 3/4"LEVEL 3 BEARING 120'-9" T.O. CHIMNEY 137'-7 5/128" 2 A304A 1 A304A 1 A307A 568 MEMORY CARE ROOF BEARING 110'-1 1/8" MEMORY CARE ROOF BEARING 110'-1 1/8" AL WING ROOF BEARING 120'-9" AL WING ROOF BEARING 120'-9" COMMON AREA ROOF BEARING 121'-9" COMMON AREA ROOF BEARING 121'-9" - --- PROJECT NO. SHEET TITLE:Plot Date:Architecture Interior Design Landscape Architecture Land Planning Construction Management 5151 South 900 East, Suite 200 Salt Lake City, Ut 84117 ph. 801.269.0055 fax 801.269.1425 www.thinkaec.com The designs shown and described herein including all technical drawings, graphic representation & models thereof, are the copyrighted work of Think Architecture, Inc. and connot be copied, duplicated, or commercially exploited in whole or in part without the sole and express written permission from THINK Architecture, Inc. These drawings are available for limited review and evaluation by clients, consultants, contractors, government agencies, vendors, and office personnel only in accordance with this notice. SHEET NUMBER: REVISIONS: DATE:1/7/2020 3:42:41 PMINGLEWOOD PLACE - SENIOR LIVING3250 E VICTORY RDMERIDIAN IDAHOJan 7, 2020 18077 IL2 EXTERIOR ELEVATIONS A205 ANNEXATION SUBMITTAL1/8" = 1'-0"A205 IL2 EAST ELEVATION 1 1/8" = 1'-0"A205 IL2 NORTH ELEVATION 2 1/8" = 1'-0"A205 IL2 WEST ELEVATION 3 KEYNOTE INSTRUCTIONAL