Townhome Elevations APPROVED SA 4.14.20ROOF BEARING
109'-0"
T.O. WINDOW
108'-0"
0
LEVEL 1 - FLOOR PLAN
100'z'
UPPER ROOF BEARING
110'-0"
ROOF BEARING
109'-0"
T.O. WINDOW
108,-0"
LEVEL 1 - FLOOR PLAN
00'-0"
UPPER ROOF BEARING
110'-0"
ROOF BEARING
109,-0"
T.O. WINDOW
108'-01,
LEVEL.1 - FLOOR PLAN
100'-0"
2 2
T
A3o, 2 A3o2 T
B , ,
y
y
A
1 1
B A302 A301 A
ROOF BEARING
109'-0"
T.O. WINDOW 4
108'-0"
LEVEL 1 - FLOOR PLAN
100'-0"
SOUTH ELEVATION
1 /4" =1'-0"
UPPER ROOF BEARING
110'-0"
ROOF BEARING
109'-0"
T.O. WINDOW
108'-01,
LEVEL 1 - FLOOR PLAN
100'-0" 17
EAST ELEVATION
1 /4" =1'Z'
UPPER ROOF BEARING
110'-0"
ROOF BEARING ak
109'-0"
T.O. WINDOW
108'-01,
LEVEL 1 - FLOOR PLAN
100'-0"
EAST ELEVATION - OPTION
ELEVATION/ SECTION MATERIAL LEGEND
HATCH PATTERN I DESCRIPTION I
ASPHALT SHINGLE ROOFING SYSTEM
FLAT SEAM METAL ROOFING SYSTEM
FIBER CEMENT LAP SIDING SYSTEM
FIBER CEMENT BOARD ON BATT SI DING SYSTEM
EXTERIOR MASONRY BRICK VENEER SYSTEM
NOTE: REFER TO MATERIAL SPECIFICATIONS DOCUMENT FOR DETAILED
INFORMATION REGARDING EACH FINISH MATERIAL
ELEVATION/ SECTION KEYNOTES
KEYNOTE INSTRUCTIONAL
03-01 CAST IN PLACE FOOTINGS TO BEAR ON UNDISTURBED SOIL OR ENG. COMPACTED FILL. SEE STRUCTURAL
& SPEC. MANUAL.
03-02 CAST IN PLACE FOUNDATION WALLS W/ INT. RIGID INSULATION & WATER PROOFING AS NOTED. SEE,
DETAILS, STRUCTURAL &SPEC. MANUAL.
03-04 EXTERIOR CAST IN PLACE CONCRETE SLABS TO BE 5" CONC. SLAB OVER 4" GRAVEL BASE WITH REBAR
REINFORCEMENT SEE DETAILS, STRUCTURAL & SPEC. MANUAL.
03-05 CAST IN PLACE EXT. CONCRETE STAIRS, SEE DETAILS, STRUCTURAL & SPEC. MANUAL.
04-06 BRICK MASONRY VENEER RUNNING BOND, MIXED COLOR AS SEL. BY ARCH. SEE DETAILS & SPEC.
MANUAL.
04-09 BRICK MASONRY VENEER SOLDIER COURSE, MIXED COLOR AS SELECTED BY ARCH. SEE DETAILS & SPEC.
MANUAL.
04-12 MASONARY WEEPS AT BOTTOM OF WALL AT 4'4O.C. SEE DETAILS & SPEC. MANUAL.
06-14 TIMBER BEAM, SEE DETAILS & SPEC. MANUAL. FINISH AS SEL. BY ARCH.
06-15 TIMBER HAUNCH, SEE DETAILS & SPEC. MANUAL. FINISH AS SEL. BY ARCH.
07-01 SPRAY APPLIED FOUNDATION WATERPROOFING. SEE DETAILS &SPEC. MANUAL.
07-10 FIBER -CEMENT BOARD & BATT PANEL SYSTEM. SEE DETAILS & SPEC. MANUAL.
07-11 FIBER CEMENT LAP SIDING SYSTEM. SEE DETAILS & SPEC. MANUAL.
07-13 FIBER CEMENT DOOR & WINDOW TRIM. SEE DETAILS & SPEC. MANUAL.
07-14 ARCH. GRADE ASPHALT ROOF SHINGLES & CONT VENT CAP. SEE DETAILS & SPEC. MANUAL.
07-15 ARCH. GRADE FLATSEAM METAL ROOFING. SEE DETAILS & SPEC. MANUAL.
07-16 ALUM. METAL FASCIA & SOFFIT. SEE DETAILS & SPEC. MANUAL.
08-16 EXTRUDED VINYL WINDOWS &SLIDING DOORS, SEE SCHEDULE, DETAILS & SPEC. MANUAL.
EL-01 CONTRACTOR SHALL VERIFY THATALL GRADE SLOPES AWAY FROM BUILDNG. SLOPE SHALL BE 6" SLOPE
IN FIRST 10'-0".
EL-08 CONTRACTOR SHALL PROVIDE FLASHING AT ALL SIDING/MATERIAL TRANSISTIONS WHETHER SHOWN OR
NOT.
Architecture
Interior Design
Landscape Architecture
Land Planning
Construction Management
7927 So. Highpoint Parkway, Suite 300
Sandy, Utah 84094
ph. 801.269.0055
fax 801.269.1425
www.thinkaec.com
The designs shown and described herein
including all technical drawings, graphic
representation & models thereof, are proprietary
& can not be copied, duplicated, or
commercially exploited in whole or in part
without the sole and express written permission
from THINK Architecture, inc.
These drawings are available for limited review
and evaluation by clients, consultants,
contractors, government agencies, vendors,
and office personnel only in accordance with
this notice.
N
Z
Q
0
--T
F
00
,L'r-v0
O
Q
LL
=
O
a
Z
F_
Lw
o
w
LJ
C/D
cN
PROJECT NO. 18077
DATE: APRIL 14, 2020
REVISIONS:
O
" SHEET TITLE:
CDEXTERIOR ELEVATIONS
CL SHEET NUMBER:
Q
w
A201
ry
I-L_I
1 /4" = 1'-0"
UPPER ROOF BEARING
110'-0"
ROOF BEARING —
109'-01,
T.O. WINDOW
LEVEL I - FLOOR PLAN
00'-0''
jii UPPER ROOF BEARING
110'-01,
ROOF BEARING —
ILI 109'-01,
T.O. WINDOW
108'-01,
LEVEL 1 - FLOOR PLAN
100'z'
UPPER ROOF BEARING
110'-01,
ROOF BEARING
ILI 109'-01,
T.O. WINDOW
108'-0"
LEVEL 1 - FLOOR PLAN —
100'-0"
►:
1 1
A A301 A302
1 1
A A301 A302 g
UPPER ROOF BEARING k
110'-0"
ROOF BEARING OL
109'-0"
T.O. WINDOW 06
108,-0"
LEVEL 1 - FLOOR PLAN OL
100'-0"
NORTH ELEVATION
1 /4" = 1'-0"
UPPER ROOF BEARING
110'-01,
— ROOF BEARING
109'-0"
T.O. WINDOW
108,-0"
LEVEL 1 - FLOOR PLAN
100'-0" If
WEST ELEVATION
1/4"= 1'-0"
UPPER ROOF BEARING
110'-01,
ROOF BEARING
109'-0"
T.O. WINDOW
108'-0"
LEVEL 1 - FLOOR PLAN
100'-0"
WEST ELEVATION - OPTION
1/41'= 1'-0"
ELEVATION/ SECTION MATERIAL LEGEND
HATCH PATTERN I DESCRIPTION I
ASPHALT SHINGLE ROOFING SYSTEM
FLAT SEAM METAL ROOFING SYSTEM
FIBER CEMENT LAP SIDING SYSTEM
FIBER CEMENT BOARD ON BATTSIDING SYSTEM
EXTERIOR MASONRY BRICK VENEER SYSTEM
NOTE: REFER TO MATERIAL SPECIFICATIONS DOCUMENT FOR DETAILED
INFORMATION REGARDING EACH FINISH MATERIAL
ELEVATION/ SECTION KEYNOTES
KEYNOTE INSTRUCTIONAL
03-01 CAST IN PLACE FOOTINGS TO BEAR ON UNDISTURBED SOIL OR ENG. COMPACTED FILL. SEE STRUCTURAL
& SPEC. MANUAL.
03-02 CAST IN PLACE FOUNDATION WALLS W/ INT. RIGID INSULATION & WATER PROOFING AS NOTED. SEE,
DETAILS, STRUCTURAL &SPEC. MANUAL.
03-04 EXTERIOR CAST IN PLACE CONCRETE SLABS TO BE 5" CONC. SLAB OVER 4" GRAVEL BASE WITH REBAR
REINFORCEMENT SEE DETAILS, STRUCTURAL & SPEC. MANUAL.
04-06 BRICK MASONRY VENEER RUNNING BOND, MIXED COLOR AS SEL. BY ARCH. SEE DETAILS & SPEC.
MANUAL.
04-09 BRICK MASONRY VENEER SOLDIER COURSE, MIXED COLOR AS SELECTED BY ARCH. SEE DETAILS &SPEC.
MANUAL.
06-14 TIMBER BEAM, SEE DETAILS & SPEC. MANUAL. FINISH AS SEL. BY ARCH.
06-15 TIMBER HAUNCH, SEE DETAILS & SPEC. MANUAL. FINISH AS SEL. BY ARCH.
07-01 SPRAY APPLIED FOUNDATION WATERPROOFING. SEE DETAILS &SPEC. MANUAL.
07-10 FIBER -CEMENT BOARD & BATT PANEL SYSTEM. SEE DETAILS & SPEC. MANUAL.
07-11 FIBER CEMENT LAP SIDING SYSTEM. SEE DETAILS & SPEC. MANUAL.
07-13 FIBER CEMENT DOOR & WINDOW TRIM. SEE DETAILS & SPEC. MANUAL.
07-14 ARCH. GRADE ASPHALT ROOF SHINGLES & CONT VENT CAP. SEE DETAILS & SPEC. MANUAL.
07-15 ARCH. GRADE FLATSEAM METAL ROOFING. SEE DETAILS & SPEC. MANUAL.
07-16 ALUM. METAL FASCIA & SOFFIT. SEE DETAILS & SPEC. MANUAL.
08-16 EXTRUDED VINYL WINDOWS &SLIDING DOORS, SEE SCHEDULE, DETAILS & SPEC. MANUAL.
EL-01 CONTRACTOR SHALL VERIFY THATALLGRADE SLOPES AWAY FROM BUILDING. SLOPE SHALL BE6"SLOPE
IN FIRST 10'-0".
EL-08 CONTRACTOR SHALL PROVIDE FLASHING AT ALL SIDING/MATERIAL TRANSISTIONS WHETHER SHOWN OR
NOT.
O
N
O
N
C�
n
Q
w
W
CL
Architecture
Interior Design
Landscape Architecture
Land Planning
Construction Management
7927 So. Highpoint Parkway, Suite 300
Sandy, Utah 84094
ph. 801.269.0055
fax 801.269.1425
www.thinkaec.com
The designs shown and described herein
including all technical drawings, graphic
representation & models thereof, are proprietary
& can not be copied, duplicated, or
commercially exploited in whole or in part
without the sole and express written permission
from THINK Architecture, inc.
These drawings are available for limited review
and evaluation by clients, consultants,
contractors, government agencies, vendors,
and office personnel only in accordance with
this notice.
C)
N
Z
Q
0
1;q-
00
0
O
ii
Q
O
a
Z
0
w
C:)
�
w
LJ
C/D
cN
PROJECT NO. 18077
DATE: APRIL 14, 2020
REVISIONS:
SHEET TITLE:
EXTERIOR ELEVATIONS
SHEET NUMBER:
A202