Loading...
PZ - Public Utility Plan LO 00 Ln i N 00 v� l i II O 1 o I • II z 0 0 O O� I � O O O (S O O O O O O N rn to � Q W �/� 0 30' 60'W co1 I c� W 11 I I I I O N co j Z • Ln d l CA w / SCALE 1" = 30' J I i r n t1 1 I I I I I I t—J I /� � II • I O o /U) o i li i iIi i � I J / 0+'00 I I 11 I I I � 1 1 r r 1+0 — I — 2+00 — 3+001 N CARISBROOKE AVE 4+00 11 to + — I — — 5+00 5+2 .78 CD ,/__-- Ln / V Ln z O CD 1 I I i �I � II •••/ II 1\� II I / // // i'i i rr nn V �, MO ell LU I I i / / i /i II O 0 0 0 0 O O O O O O O O ,,,,',,-%;-A20 /iiii� w O LL-1";e; LL CID / � //ge, i� II it / 1 el W W � � LW O CD O n n CARISBROOKE PROFILE m 0+00 1 +00 2+00 3+00 4+00 5+00 5+30 2560 2560 U � M N n C? r'7� +N CD m 2555 CD 2555 +N \ m 00 CD U CD 1.3710.1 rn CDFINISHED GRADE Y N� fv^ U 04 — — m O N - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -0.40% rn a - - - - - - - - - - - - - - - - - - - W 2550 - - - - - - - - - - - - - - - - - - - - - 2550 W � � cn I Cn z EXISTING GRADE Q w C14 I-o o N Q �J J w W O () U O M = CD O � m S V m L1J o z � Q w L�J = Q 2545 2545 � U C:) `L- 0+00 1 +00 2+00 3+00 4+00 5+00 5+30 Plans Are Accepted For Public Street Construction By stamping and signing the improvement plans, the Registered Engineer ensures the District that the plans conform to all District policies and standards. Variances or waivers must be specifically and previously approved by the District in writing. Acceptance of the improvement plans by the District does not relieve the Registered Engineer of these responsibilities. BY DATE SHEET ADA COUNTY HIGHWAY DISTRICT C3 . 0 w o CD LO it 2551 — ------------ \ ^�� �+ 0 \ 00 II 10 10 i O \\ LO LO 11 11 � E � N o BLOCK 3 BLOCK 4 S z I 12 12 00 0 I w > LLJ _ I OWNER: MARK N. HALL I— — I 1' 0 30' 60' w 13 c° I II 13 N I SCALE 1 30" = ' J I � r n IIF O V 14 14 CD + Q I � I "' J I I ii J OWNER: ANDREW ECHAVARRIA U I W ASCENT ST 1+00 2+100 LLJ \ \ 1 I I Z 0 O I \I I IQ V > Q I I fJ'--- m w / \ LL 14 13 12 11 a O8 O O O O4 0 2O O \\ 1 m Z � Iw W BLOCK 6 BL CK 6 BLOCK 6 W ` o U � ---- ----- -- `---- I I ,co - - - - - - 10 - -- - - -- - - - \ / - - ------------- — —— _— - - ---——————-- . �5'3�"P1r66.65' — -- — . , • . ,• . , . T=7 Id P d, • , • A . — . . A A.• - • -------------, a , --� yi--- _ --------------------- _ _ .. a a a W —� .---------------------------------------- / • d • ——— — W — --------- ----------------------- � �---------------- -- ----------------- -- — ---- _—N 34'724"E_ --- ---------- — W W_ -------------- — — — -- -226A QSI' — — — — — — — — --- — — — — 376.45' - ------------r-------- W. FRANKLIN ROAD (PUBLIC) ------------- W O W n ASCENT-ALLEY PROFILE 0+00 1 +00 2+00 3+00 Q 2560 2560 Q o� 2555 �� 2555 N +Lo O O N � O O m m +LO O M �' FINISHED GRADE `v o,n o �m (D M N Y m m -0.40% -0.40%--------- � L IN _0.40% w rn � r- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - — — — Cc LE UJ UJI -� M 2550 1I 7 EXISTING GRADE 2550 z W _ _ w t^ Lil ON ON J (n Q N CD Lj � Z Y O O H w W (Cn U O n CD M m 0 V m � w in Z Y � LLJ = Q W I­__ J 2545 2545 0+00 1+00 2+00 3+00 Plans Are Accepted For Public Street Construction By stamping and signing the improvement plans, the Registered Engineer ensures the District that the plans conform to all District policies and standards. Variances or waivers must be specifically and previously approved by the District in writing. Acceptance of the improvement plans by the District does not relieve the Registered Engineer of these responsibilities. BY DATE SHEET ADA COUNTY HIGHWAY DISTRICT C3 . 1 LO 00 Ln I N \ 9 1 I II C) C) � I o 1 / I _ _ _ _ � ,�i/ // // ,/iiiiiii / II I � � �/ O O O O O � O O O O O O O O // / //� /� i////,� Q W 0 30' 60' W SCALE 1" = 30' J z rri z3+00 4+00 WEST ALLEY 5+00 z6 i7 z r , 1 77 �// -ri CD z CD III I I I j \ W /i i/' / // i/ /'/// //' / III I I II \ r ,/iii i i i,�ii/,,/i — 1I // / / V CT 0 CID Cn 1 WW �\ I SO`34'26"W 370.89' 1 I I I L/ W W LW O n ASCENT-ALLEY PROFILE C 3+00 4+00 5+00 6+00 6+23 W 2560 2560 Q 2555 2555 O M O O� +Lr) U MN r^ 0% m O V N U) N C) EXISTING GRADE ,p N m CD UJcn I 3 J W00 '""0M N � N U 2550 \ 2550 t^ t Lil� ON U (n FINISHED GRADE O m S \ v m i \ z L�j Q w ow� = Q — o U o = o 2545 2545 Plans Are Accepted For Public 3+00 4+00 5+00 6+00 6+23 Street Construction By stamping and signing the improvement plans, the Registered Engineer ensures the District that the plans conform to all District policies and standards. Variances or waivers must be specifically and previously approved by the District in writing. Acceptance of the improvement plans by the District does not relieve the Registered Engineer of these responsibilities. BY DATE ADA COUNTY HIGHWAY DISTRICT SHEET C3 . 2 LO 00 Ln i N ri It O / I — — � .-- - - - - - _--- - - -- -- - - - —— - - - - --- — — — — — — — — — — — — - 00 I. --- z I 803 / ---- � O 2�03 2:103 �103 8D3 Cn _ /N ' i' I N. ZIMMERMAN LANE ,' 2I03 2�03 2�03 > N �i' ,// I (PRIVATE) �'� LLJ 0 30' 60' � ' /�,'� EGR EGR EGR Ems= __-- EGR EGR EGR EGR Z If/ IF i EGR '----- I � � - - J It j I Ii I OP SCALE 1" - 30' I I — --- — _ �P — NO°34'26"E 809.37' — ______TO - - ---- ------- / BLOCK 2 — '� i I i II O8-- / / ' 789.37' ---- �.0 J I I j I I IC-0 dEl 0400 1+00 / EAST ALLEY n O — �— — — — i — 2+I00 — — 3+I00 _ 3+56.78 o J U z O O � I ; I � ; o l I 1► I I � > � M W O n I m 1 � 0 0 0 0 @1 O O O O O O O O n � � co Oo V C� Cr � W N 11 11 I I j I I I I M ,�/ O U J CD I I I II 1 CO � rrr j I II N O6 (nn W II III I I N O 7� I / M 3 II i W II III it I , I W ' I , / Q I I �• I W it W CD Q n ALLEY PROFILE 0+00 1 +00 2+00 3+00 3+57 2560 2560 W Q n o� 2555 cA 2555 +N O m O 003 � FINISHED GRADE N m m Q N ------------ -0.42% z N — — — — — — — — — — Cc a - - - - - - - - - - - - - - - - - - - - - - - - - W 2550 - - - - - - - - - - - - - - — — — — — — — — 2550 W cn o I00 z EXISTING GRADE a- J LCD oN N =1PCD(n CD W Y O w WCD () U O M O CD a- M m S V m W o z � Q w L�J Q r o = o U o LL- o 2545 2545 0+00 1 +00 2+00 3+00 3+57 Plans Are Accepted For Public Street Construction By stamping and signing the improvement plans, the Registered Engineer ensures the District that the plans conform to all District policies and standards. Variances or waivers must be specifically and previously approved by the District in writing. Acceptance of the improvement plans by the District does not relieve the Registered Engineer of these responsibilities. BY DATE SHEET ADA COUNTY HIGHWAY DISTRICT C3 . 3 LO 00 OWNER: GLENN NEWKIRK FAMILY TRUST N LLI E 00 0 LLJ O I , ` ♦,`\`� `,,,,,,♦ I 6 BLOCK 1 `� ,\, �� \ ,`�„\����, \ �� \ SCALE 1" = 30' J LLI i J z o 0�00 W PERUGIlI+�O \ `,\,\��\\ ,\\� ���,'�' \ CD \ � 0 LU OLLI BLOCK 3 BLOCK 4 w O2 �\,\�,` \ LU O LLJ M C14 �I I BLOCK 5 ,\�,��`�`�� W L� Q O C� n-� PERUGIA PROFILE 0+00 1 +00 2+00 2+78 00 CD CD n 00o N LQ� p N O+N I O Lr)3a 6 O U U ±N n � FINISHED GRADE m +CD N N Cl M -0.40% 41 - .40% — — — — — — — — — — — — — — — — % 2550 - - - - - - - - - - - - - - - - - - _-0.40% - - - 2550 N m v O v=i EXISTING GRADE LLJ a w - °O t^ Lil ON N U N �Jv Q L N N n Z Y � O w W () U O M 2545 2545 o m CD 0+00 1+00 2+00 2+78 V mo z w Q w L o = Q o c� o L- o Plans Are Accepted For Public Street Construction By stamping and signing the improvement plans, the Registered Engineer ensures the District that the plans conform to all District policies and standards. Variances or waivers must be specifically and previously approved by the District in writing. Acceptance of the improvement plans by the District does not relieve the Registered Engineer of these responsibilities. BY DATE SHEET ADA COUNTY HIGHWAY DISTRICT C3 .4 LO 00 \ \ LID p `\ CV CY) O o LLJ \ \ \\ 0 50' 100' w � SCALE 1" = 50' I BLOCK 1 \\ 0 \ \\ Q Z O O � o 10 s \ + \ - - - - I M 0 O c- Q ILL O BLOCK 1 \\\ `\\ W I J 8 `�� \ \ m L� W W o' w \\ \ Q I \\ W W LINE A S PERUGIA \ \ I x 1 I I \ O BLOCK Q 2 BLOCK 4 J I \ I BLOC 2 \\ \ Q w I 0 0 0 \ \ c I m Uj wl \ � w I \ I BLOCK 5 10 10 O ( LI—I I 11 11 I � 12 BLOCK 12 I (� O BLOCK 4 I 13 13 w I 14 z I 14 J Y M ♦^ i MCn V N m LINE CS ASCENT LINE B Z N S I w rn I N I I I J U awo Cn 14 13 12 11 l0 9 8 7 6 5 4 3 2 1 z New ¢ w O O O O O O O O O O O Ww � C v � oIM BLOCK B C BLOCK 61 V o m o CD 0 E IDIAN - APPROVED FOR z CONSTRUCTION Q w W w � = Q J (Y - - - - - - 8 - - - - o 0 o LL o These plans and/or specifications have been reviewed for —W W _ _ compliance with Meridian City Standards and Specifcations. W- This review does not relieve the owner, engineer, or contractor — — — — — — of the responsibility to design and/or construct those facilities — I — — — — — — — — — — — — — in compliance with all current applicable federal, state and local laws, rules, regulations, ordinances, development agreements, specifications, orders or approvals, all of which the City retains — the right to enforce. Inconsistencies not noted by City staff shall SS SS o SS not be construed as approved unless specifically addressed in writing by the City. Any proposed revision to these plans must be submitted for review and compliance with the Meridian City Standards and Specifications before said revision is constructed. SHEET Name Date C4 . 0 LO 00 - 2�03 2�03 2�03 2�03 Ln N I N. ZIMMERMAN LANE 2�03 803 r (PRIVATE) -EG' --r-EGR EGR EGR EGR EGR EGR SSMH 9 `� I EGR STA: 1+38.05 i U� 1 0 I k-4-4 OP- np-� np np NO°34'26"E 809.37' C II Og BLOCK 2 789.37' + I W Z 0 o I I i C) M M- ~ +7 LINE D c° LLJ I 0 30' 60' �I s s W SSMH 2 Z J- - I I 3 STA: 5+94.88 - - - - _ � I SCALE 1 = 30, J - - - -I- - - - - I O cNn I W I I I I Q O Q 0 0 0 0 0 0 0 0 6 0 0 0 0 N 0 6 0 m Z CG 00 V Q> Cl't � Crl N V 01 C11 Im N I I co W Uj z O O O rn NI - 3 (D _ 0 I I w w p) w w V00 / z_ N I J J Q N Ial STA: 0+39 53 O STA: 1+22.55 mow// M LINE A S 1+00 LINE A W 2+�00 3+ISO 4+00 LINE A O O Q I s- s s s c� - r - - - - - - N CARISBROOKE AVE _ _ _ SSMH 3 0 SSMH 0+00.00 6 I W - STA: 4+79.33 w STA: M M M M M • I I O // m O / � W I 00 Qp 3 D I I J G0- O o .n I I N 0 zl O O O O O O O 0 0 O O 0 0 6 I I / / co Gxlkl- /i SEWER LINE A PROFILE W Q I 0+00 1 +00 2+00 3+00 4+00 5+00 6+00 6+21 1 W 0 - - - - - - - -FINISHED S-HE D-GRADE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - W - - - - - - - - - -2550 C� � EXISTING GRADE 8" WATER MAIN 8" WATER MAIN 2545 2545 0 24.01 LF 8" SEWER @ 0.42% N m 35.53 LF 8" SEWER @ 0.42% 4 z o N 111.55 LF 8" SEWER @ 0.40% W 352.78 LF 8" SEWER ® 0.40 LUN rn 79.03 LF 8" SEWER 0.4 % 4 48"0 SSMH 2 Z N oo w 2540 48"0 SSMH 5+94.88 SEWER LINE A-SW 2540 U a w o N Q 4+79.33 SEWER LINE A-SWR z ci, c' w Y of w RIM 2550.5 8" IN 2542.33-W w C) " IN 2542.33-N U v o � a = 8" IN 2541. 8-W 8 o a 48"0 SSMH 4 8" OUT 254 .68-S 8" OUT 2542.23-E CD m E48COSSMH 1+22.55 SEWER LINE A-SWR 48"0 SSMH 6 39.53 SEWER LINE A-SWR RIM 2551.8t 0+00.00 SEWER LINE A-S�I m � o RIM .00 S t 2553.0t 8" IN 2540.26-N CAW " APPROVED FOR z RI IN 2539.59-NW 8" IN 2539.84-N 8" IN 2540.26-E IDAHO E I I N.- 8" OUT 2539.49-S 8 OUT 2539.74-SE 8" IN 2540.26-W o v o o 8" OUT 2540.16-S CONSTRUCTION Q w � w These plans and/or specifications have been reviewed for 2535 2535 compliance with Meridian City Standards and Specifcations. This review does not relieve the owner, engineer, or contractor of the responsibility to design and/or construct those facilities in compliance with all current applicable federal, state and local laws, rules, regulations, ordinances, development agreements, specifications, orders or approvals, all of which the City retains the right to enforce. Inconsistencies not noted by City staff shall not be construed as approved unless specifically addressed in writing by the City. Any proposed revision to these plans must be submitted for review and compliance with the Meridian City Standards and Specifications before said revision is constructed. 2530 2530 SHEET 0+00 1 +00 2+00 3+00 4+00 5+00 6+00 6+21 Name Date C4 . 1 LO 11 N 11 00 ' LO I I N BLOCK 3 I CV 12 BLOCK 4 I � 12 W E C� — —CD 6 w b OOWNER: MARK N. HALL I O I 00 � I 13 S �O � F 14 14 �0 0 30' 60' Q �W I I I z I I - SSMH 9 SCALE 1" = 30' rrJnn STA: 1+38.05 n V M M M M OWNER: ANDREW ECHAVARRIA Of Q w J 1+ S 0 0 S 1+00 1+00 S 1+ 12 J � � I Q I � ., SSMH 4 JLU O STA: 1+22.55 STA:H 1$85.12 I v m 3 z O O CD U-) = 0 o 0 0 � I 14 13 12 11 10 9 O O O O O O O O I W c� w � wo BLOCK 6 BL C 6 BLOCK 6 I O Q � SSMH 5 m STA: 0+39.53 I I I W W �I U _ - - - - - - - - - - - - - - - - a - , : ♦ • d • •d • A d ♦ \� . \ •. d •• d d♦ • • .A. d W W — —SSMH 6 a d STA: 0+00.00 vv I — — — — — — — — — — — — — — — — — — — — — — — — W. FRANKLIN ROAD (PUBLIC) SS— �SS o SS SS 0 U SEWER LINE C PROFILE SEWER LINE B PROFILE 1 +38 1 +00 0+00 0+00 1 +00 1 +85 m O FINISHED GRADE W FINISHED GRADE C — — — — — — — — — — — — — — — — — — — — — — — — — EXISTING GRADE W 2550 2550 Q EXISTING GRADE 2550 2550 W C� 8" WATER MAIN 8" WATER MAIN 25415 2545 254 15 2545 0 �•w■ U V T N m Q N N FL ~ cn10 N N � I = w W 0 Q U N 4.05 LF 8" SEWER ® 0.41� 181.12 LF 8" SEWE © 0.41% Q — N cn a 2540 2540 (~ -_ W c0 Q w 48"� SSMH 9 2540 48 540 0 SSMH 8 iz w �J o (n U o o 1+38.05 SEWER LINE C SWR 48"� SSMH 4 1+85.12 SEWER LINE B-SWR CD M RIM 2552.4t RIM 2551.1 t C° 1+22.55 SEWER LINE A SWR 48"0 SSMH 4 V 8" OUT 2540.81-E RIM 2551.8t 1+22.55 SEWER LINE A-SWR 8" OUT 2541.00-W RIM 2551.8t i� m � / 8" IN 2540.26-N E IDIAN_ APPROVED FOR 8" IN 2540.26-E 8" IN 2540.26-N I D A H O Q w L 8" IN 2540.26-W 8" IN 2540.26-E CONSTRUCTION � = Q J v 8" OUT 2540.16-S 8" IN 2540.26-W 8" OUT 2540.16-S These plans and/or specifications have been reviewed for compliance with Meridian City Standards and Specifcations. 2535 2535 2535 2535 This review does not relieve the owner, engineer, or contractor of the responsibility to design and/or construct those facilities in compliance with all current applicable federal, state and local laws, rules, regulations, ordinances, development agreements, specifications, orders or approvals, all of which the City retains the right to enforce. Inconsistencies not noted by City staff shall not be construed as approved unless specifically addressed in writing by the City. Any proposed revision to these plans must be submitted for review and compliance with the Meridian City Standards and Specifications before said revision is constructed. 2530 2530 2530 2530 SHEET 1 +38 1 +00 0+00 Name Date 0+00 1 +00 1 +85Z�_- j C4 . 2 LO 00 Ln 2103 2�C3 2iO3 2�03 � � N EGR EGR EGR EGR cn C'7 O O 00 -NO°34'26"E 809.37' 1771 1z 789.37' G �- — O O Cn LLJ M M 0 30' 60' � LU T0 0 S 1+0 cn 1+ 4 O 7 SSMH 2 SSMH 7 SCALE 1" = 30' LJ STA: 5+94.88 STA: 1+48.41 V 0 J J / Q O O — I O O O O O _0 co z G.q j z o 0 0 w � W m / O s LL SSMH 3 ;)K / STA: 4+79.33 / °y // / w M /// m W W / / U / ellQ W SEWER LINE D PROFILE 0+00 1 +00 1 +48 W CD n FINISHED GRADE W W Q 2550 - - - - - - - - - - _ — _ 2550 EXISTING GRADE g" WATER MAIN 254 545 41 �F g„ SEWER ® 1.85% m 144. 48"0 SSMH 7 Z N r 1+48.41 SEWER LINE D-SWR w rn RIM 2551.5t a' � rn o 8" OUT 2545.00-S `n � W � 00 � po U' o Z 48"0 SSMH 2 Q 4J C 4 oN N 2540 5+94.88 SEWER LINE A-SWR 2540 z N CDw ¢ Uj � Z � 00 RIM 2550.8± oCQ 8" IN 2542.33-W o a 8" IN 2542.33-N m 8" OUT 2542.23-E V m o i (�/-W IDIAN - APPROVED FOR zLi IDAHO Q W W Li CONSTRUCTION � = Q J o � oLL_ o These plans and/or specifications have been reviewed for compliance with Meridian City Standards and Specifcations. 2535 2535 This review does not relieve the owner, engineer, or contractor of the responsibility to design and/or construct those facilities in compliance with all current applicable federal, state and local laws, rules, regulations, ordinances, development agreements, specifications, orders or approvals, all of which the City retains the right to enforce. Inconsistencies not noted by City staff shall not be construed as approved unless specifically addressed in writing by the City. Any proposed revision to these plans must be submitted for review and compliance with the Meridian City Standards and Specifications before said revision is constructed. 2530 2530 Name Date SHEET 0+00 1 +00 1 +48 C4 . 3