Loading...
A1-1_REVISED FLOOR PLANWD8' - 0"34' - 0"12' - 6"13' - 6"7' - 6"23' - 0"18' - 6"20' - 0"61' - 6"7' - 6"8' - 0"9' - 0"18' - 0"15' - 0"18' - 0"15' - 6"0' - 8"10' - 0"28' - 6"8' - 0"15' - 0"0' - 8"10' - 0"10' - 4"8' - 6"18' - 8 1/2"13' - 11 1/2"10' - 5 1/2"4' - 3 1/2"5' - 7"7' - 9 1/2"9' - 8 1/2"9' - 8 1/2"4' - 0"9' - 11 1/2"20' - 5 1/2"8' - 6"9' - 4 1/2"7' - 1 1/2"16' - 0 1/2"13' - 5 1/2"11' - 3 1/2"7' - 6"13' - 11"8' - 1"5' - 3 1/2"7' - 11 1/2"13' - 6"11' - 3 1/2"4' - 4"11' - 1"5' - 7"5' - 6"8' - 9"9' - 0 1/2"5' - 5"6' - 11 1/2"3' - 4"7' - 6"13' - 11"3' - 0"5' - 1"5' - 3 1/2"7' - 11 1/2"12' - 0"13' - 2"15' - 0"10' - 10"9' - 0 1/2"5' - 5"4' - 11 1/2"5' - 4"21' - 5"3' - 0"5' - 1"5' - 9"7' - 6"8' - 0"VESTIBULEADMINSTORAGESTORAGERECEPTIONWAITING EXAM 1EXAM 2EXAM 3FOOD STORAGESTAFFUTILITIESMECHANICALISOLATIONTREATMENTLABRxX-RAYOFFICESURGERYEXAM 4/GRIEVINGVESTIBULESURGERY PREPDOG CAGESDOG KENNELSIT8' - 0"13' - 5 1/2"11' - 3 1/2"7' - 6"13' - 11"5' - 4 1/2"8' - 0"EXAM 4EXAM 5FENCED DOG AREAFLOOR DRAIN3' - 0"4' - 6"4' - 6"3' - 0"2' - 3"3' - 6"2' - 3"3' - 0"3' - 6"7' - 9"7' - 3"3' - 6"3' - 6"5' - 0"5' - 0"4' -0" x 5' -0"8' -0" H.H.4' -0" x 5' -0"8' -0" H.H.4' -0" x 5' -0"8' -0" H.H.4' -0" x 5' -0"8' -0" H.H.4' -0" x 5' -0"8' -0" H.H.3' -0" x 4' -0"8' -0" H.H.3' -0" x 4' -0"8' -0" H.H.4' -0" x 5' -0"8' -0" H.H.8' - 0"4' - 0"4' - 6"7' - 8"15' - 4"2' - 6"12' - 6"2' - 6"11' - 0"3' -0" x 6' -6"8' -0" H.H.3' -0" x 6' -6"8' -0" H.H.3' -0" x 6' -6"8' -0" H.H.3' -0" x 5' -0"8' -0" H.H.3' -0" x 5' -0"8' -0" H.H.3' -0" x 5' -0"8' -0" H.H.3' -0" x 5' -0"8' -0" H.H.3' -0" x 5' -0"8' -0" H.H.3' -0" x 5' -0"8' -0" H.H.5' -0" x 5' -0"8' -0" H.H.3' -0" x 5' -0"8' -0" H.H.4' -0" x 5' -0"8' -0" H.H.4' -0" x 5' -0"8' -0" H.H.7' - 0"2' - 0"4' - 5"3' - 6"10' - 1"15' - 0"10' - 0"8' - 0"6' - 8"6' - 0"10' - 4"BBBAAAAABBBBBBBCAABBBBBx3' - 0"7' - 0"190BBBBBAABBBBBBBBBCBASEE: ELEVATIONS FOR FINISH COLORSTYPICAL INTERIOR WALL: WOOD STUDS AT 16" O.C. WITH 5/8" GYPSUM BOARD EACH SIDE. PROVIDE SOUND BATT INSULATION AT ALL NEW WALLS. INSTALL WALL TO STRUCTURE ABOVE. TAPE, ORANGE PEEL TEXTURE & PAINT.B2 X 4 WOOD STUDSPLUMBING WALL: WOOD STUDS AT 16" O.C. WITH 5/8" GYPSUM BOARD EACH SIDE. TAPE, ORANGE PEEL TEXTURE & PAINT.C2 X 6 WOOD STUDSINTERIOR EXTERIORA2 X 6 WOOD STUDSTYP. EXTERIOR WALL: FIBER CEMENT SIDING (REFER TO ELEVATIONS AND SECTIONS) OVER BLDG. WRAP & EXTERIOR SHEATHING ATTACHED TO 2X6 WD. STUDS @ 16" O.C. W/ (1) LAYER 5/8" GYP. BD. AT EXPOSED INTERIOR FACES. PROVIDE MIN. R-21 BATT CAVITY INSUL.WALL TYPESTYPICAL INTERIOR WALL: METAL STUDS AT 16" O.C. WITH 5/8" GYPSUM BOARD EACH SIDE. PROVIDE SOUND BATT INSULATION AT ALL NEW WALLS. INSTALL WALL TO STRUCTURE ABOVE. TAPE, ORANGE PEEL TEXTURE & PAINT.B3 5/8" METAL STUDSA6" METAL STUDSTYP. EXTERIOR WALL: FIBER CEMENT SIDING (REFER TO ELEVATIONS AND SECTIONS) OVER BLDG. WRAP & EXTERIOR SHEATHING ATTACHED TO 6" METAL STUDS @ 16" O.C. W/ (1) LAYER 5/8" GYP. BD. AT EXPOSED INTERIOR FACES. PROVIDE MIN. R-21 BATT CAVITY INSUL.- OR -- OR -PLUMBING WALL: METAL STUDS AT 16" O.C. WITH 5/8" GYPSUM BOARD EACH SIDE. TAPE, ORANGE PEEL TEXTURE & PAINT.C6" METAL STUDS- OR -DRYWALL NOTES:1. 5/8" SHEETROCK INSTALLED ON ALL CEILINGS.2. 1/2" SHEETROCK INSTALLED ON ALL WALLS, UNLESS NOTED.3. ANY FIREWALLS WILL BE NOTED ON PLANS WITH SPECIFICATIONS FOR RATINGS.4. SHEET PERIMETERS SHALL BE NAILED AND FIELD SCREWED PER CODE REQUIREMENTS.5. STANDARD FINISHING PRACTICES OF TAPING, COATING AND SANDING.6. CORNER BEAD ON ALL CORNERS UNLESS DIRECTED BY GENERAL CONTRACTOR.7. FINISH OF DRYWALL SHALL BE 'HAND TEXTURED' w/ HAND DOBBED CEILINGS AS STANDARD, UNLESS DIRECTED BY GENERAL CONTRACTOR. NOTE: BULK OF PROJECT MAY BE 'STANDARD' WITH SPECIAL AREAS OF SMOOTH TEXTURE.8. ALL STEPPED CEILINGS ARE NOT TO RECEIVE ANY CORNER BEAD UNLESS DIRECTED BY GENERAL CONTRACTOR. ANY CORNER BEAD INSTALLED IN THESE AREAS IN ERROR SHALL BE THE RESPONSIBILITY OF THE SUB CONTRACTOR TO REMOVE AND DISPOSE OF THE MATERIALS AT THEIR EXPENSE. 9. PROVIDE WATERBOARD AT ALL TUB AND SHOWER LOCATIONS.10. DRYWALL CONTRACTOR TO PRIME FINISHED TAPED, COATED, AND SANDED AREAS PRIOR TO TEXTURING.11. DRYWALL CONTRACTOR TO REMOVE ALL DRYWALL SCRAP, DEBRIS, AND LEFT OVER MATERIALS FROM JOB.GENERAL NOTES:1. EXTERIOR WALLS 2x6, INTERIOR WALLS 2x4 UNLESS NOTED. DOUBLE TOP PLATE AND SINGLE BOTTOM PLATE. 2. FIELD VERIFY ALL DIMENSIONS.3. VERIFY ALL WINDOW AND DOOR HEADER HEIGHTS WITH GENERAL CONTRACTOR.4. WINDOW AND DOOR HEADERS TO BE 4x8 DF w/ 2X6 TOP AND BOTTOM PLATES UNDER 5'-0" SPAN. USE 4x10 w/ 2x6 TOP AND BOTTOM PLATE AS HEADERS UP TO 7'-0" SPAN w/ DOUBLE CRIPPLES. ALL LARGER SPAN HEADERS WILL BE CALLED OUT ON PLAN.5. SHEAR PANELS ARE TO BE 7/16" OSB SHEATHING w/ MIN. 6d NAILS OR MIN 1 3/4" GAUGE STAPLES 12 o.c. FIELD NAILING AND 3" PERIMETER NAILING. SEE FOUNDATION PLAN FOR STHD14 STRAP LOCATIONS.6. ROOF SYSTEM TO BE PRE-ENGINEERED MANUFACTURED WOOD TRUSSES. SEE TRUSS MANUFACTURER LAYOUTS AND SPECIFICATIONS FOR INSTALLATION. 7. USE TEMPERED GLAZING IN DOORS, SLIDING PATIO DOORS, STORM DOORS, SHOWER & BATH ENCLOSURES, WINDOWS WHERE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN 48" OF A VERTICAL EDGE OF AN ACTIVE DOOR AND FIXED PANELS GREATER THAN 9 SQ FT WITH THE LOWEST EDGE LESS THAN 18" ABOVE FLOOR. 8. IN COMBUSTIBLE CONSTRUCTION, FIRE BLOCKING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS - BOTH VERTICAL AND HORIZONTAL - AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY & THE ROOF SPACE.9. IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS UNUSABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQ.FT.SHEET NUMBERJOB NO.DRAWNDATECHECKEDARCHITECT STAMPTHIS BAR IS 1 INCHON ORIGINAL DRAWINGIF NOT 1 INCH ON THIS SHEET, ADJUST SCALES ACCORDINGLYVERIFY SCALES01"JESSICA4/9/2020 4:29:06 PM C:\Users\Jessica\Dropbox\_ Work _\12.15 Design\2020\Ada Vet Clinic\Ada Veterinary Clinic_working set.rvtA1.1ADA VETERINARY CLINIC3889 E AMITY RD MERIDIAN00303.20.2020PRELIMINARY FLOOR PLAN04.09.202003.20.20201/4" = 1'-0"11 - MAIN FLOOR