Loading...
BEEHIVE MERIDIAN LANDSCAPE PLANS (2020-01-09)MWSDSDEPEPCOCOCOCOCOGMTROHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHPOHP GIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRR/WR/WR/W WWMTRWVSIVGFEEPEPIRROHPOHPOHPOHPOHPOHPOHPOHPIRR PIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRR LINDER ROAD SEWER & WATER EASEMENTINST.No.2018-09835722.5' LANDSCAPE BUFFER5' SLOPE EASEMENT10' UTILITY EASEMENT14' ACHD EASEMENTIPCO EASEMENT UNNAMED ACCESS DRIVE (1) FP(3) CI(1) CF(1) AB(5) CK(2) PH2(3) RGCA (1)BG (6)PH2 (1)MS (1)(3) PL(3) PH2(5) CK(2) LMHB (4)LP (2)PH2 (2)(5) LP(3) PLRG (1)PP (1)HB (5)SG (1)JB (2)(1) CF(3) CK(1) QW(1) AB(4) BHLM (5)CF (1)PH (5)RG (3)QW (1)QW (1)(4) LM(1) JS(3) HB(1) PPCF (1)LM (3)QW (1)PN (3)RG (3)CI (5)CF (1)(5) CI(1) CA(6) BG(1) PH2(17) JBBH (1)RG (4)SS (4)CF (1)(4) LM(2) PLSS (8)BG (5)(8) PL1112.7'8.8'8.8'14.5'9.1'22.9'7.3'5.7'GI (1)SM (8)LM (8)(2) PL(6) CKBH (1)PL (1)LM (8)(1) CA(6) BG(1) PH2MS (1)PN (3)CA (1)PH2 (1)BG (6)(3) LM(1) CF(7) SM(6) BH(2) JB(1) JS(3) CM(4) SM(1) PH2(4) PH(5) SS(1) CFLM (3)PH (4)Keynotes:1.CUT EDGE AT TURF BORDERING PLANTING BED. SEE DETAIL 5/L1.50.CALLOUT NUMBERS COORDINATEDTO NUMBERED NOTES BELOW.Material Legend:ROCK MULCH PERSPECIFICATION SECTION32 93 00LARGE BASALT BOULDERS,3'-4' DIA. TYP. SEE DETAIL4/L1.50.#TURF SOD PERSPECIFICATION SECTION32 92 00Landscape Plan Notes:A.REFER TO PLANT SCHEDULE, SHEET L1.50.B.CONTRACTOR TO COMPLY WITH GENERAL NOTES ON C1.00.C.CONTRACTOR TO VERIFY LOCATION OF ALL UTILITIES PRIOR TO INITIATION OF ANYDEMOLITION OR CONSTRUCTION OPERATIONS. ANY DAMAGE TO EXISTING UTILITIESSHALL BE CONTRACTOR'S RESPONSIBILITY.D.ALL PLANT MATERIAL SHALL CONFORM TO THE CURRENT AMERICAN ASSOCIATIONOF NURSERYMAN'S NATIONAL STANDARD SPECIFICATIONS.E.ALL PLANT MATERIAL SHALL BE INSTALLED AS PER DETAILS AND CONTRACTSPECIFICATIONS.F.CONTRACTOR SHALL COORDINATE PLANTING WITH IRRIGATION CONTRACTOR.G.NO SUBSTITUTIONS WILL BE ALLOWED WITHOUT THE WRITTEN CONSENT OF THELANDSCAPE ARCHITECT.H.ALL NON-TURF PLANTERS SHALL RECEIVE 4" LAYER OF DECORATIVE ROCK MULCH.I.IN THE EVENT OF A DISCREPANCY, NOTIFY THE LANDSCAPE ARCHITECTIMMEDIATELY.NOTFORCONSTRUCTIONPURPOSESPROJECT NO.DATE:DRAWN BY:CHECKED BY:DRAWING NO.:REVISIONSPROJECT: SHEET TITLE:19019BEEHIVE FEDERAL CREDIT UNION 5968 N LINDER RD.03.25.2020DTDMTANEW BUILDING FOR: MERIDIAN, IDAHO 83646 TLG PN:119189Horizontal Scale: 010'20'1" = 10'Landscape PlanFile Location:g:\2019\119189\cad\119189 cd l100 landscape plan.dwgLast Plotted By:david duperaultDate Plotted:Wednesday, March 25 2020 at 03:30 PM L1.00Landscape Plan CLASS I TREESCODEBOTANICAL / COMMON NAMESIZECONTAINERREMARKSCACERCIS CANADENSIS `APPALACHIAN RED`EASTERN REDBUD2" CAL.B&B20` H X 20` WCFCARPINUS BETULUS `FRANZ FONTAINE`FRANZ FONTAINE HORNBEAM2" CAL.B&B35` H X 15` WMSMALUS X `SPRING SNOW`SPRING SNOW CRAB APPLE2" CAL.B&B20` H X 20` WCLASS II TREESCODEBOTANICAL / COMMON NAMESIZECONTAINERREMARKSABACER RUBRUM `BOWHALL`BOWHALL MAPLE2" CAL.B&B40` H X 15` WFPFRAXINUS PENNSYLVANICA `PRAIRIE SPIRE`PRAIRIE SPIRE ASH2" CAL.B&B50` H X 25` WGIGLEDITSIA TRIACANTHOS INERMIS `SKYCOLE` TMSKYLINE THORNLESS HONEY LOCUST2" CAL.B&B40` H X 30` WQWQUERCUS X WAREI `LONG` TMREGAL PRINCE OAK2" CAL.B&B50` H X 20` WEVERGREEN TREESCODEBOTANICAL / COMMON NAMESIZECONTAINERREMARKSSGSEQUOIADENDRON GIGANTEUM `PENDULUM`WEEPING GIANT SEQUOIA10` HT.B&B40` H X 12` WSHRUBSCODEBOTANICAL / COMMON NAMESIZECONTAINERREMARKSBGBUXUS MICROPHYLLA `WINTER GEM`GLOBE WINTER GEM BOXWOOD2 GAL.BHBERBERIS THUNBERGII `HELMOND PILLAR`COLUMNAR BARBERRY2 GAL.CICORNUS ALBA `IVORY HALO` TMTATARIAN DOGWOOD3 GAL.CKCALAMAGROSTIS X ACUTIFLORA `KARL FOERSTER`FEATHER REED GRASS2 GAL.CMCOREOPSIS VERTICILLATA `MOONBEAMMOONBEAM THICKLEAF TICKSEED1 GAL.HBHESPERALOE PARVIFLORA `BRAKELIGHTS` TMBRAKELIGHTS RED YUCCA5 GAL.JBJUNIPERUS SCOPULORUM `BLUE ARROW`BLUE ARROW JUNIPER5 GAL.JSJUNIPERUS SCOPULORUM `SKYROCKET`SKYROCKET JUNIPER5 GAL.LMLAVANDULA ANGUSTIFOLIA `MUNSTEAD`MUNSTEAD ENGLISH LAVENDER1 GAL.LPLAVANDULA X INTERMEDIA `PHENOMENAL`LAVENDER2 GAL.PHPANICUM VIRGATUM `HEAVY METAL`BLUE SWITCH GRASS2 GAL.PH2PINUS SYLVESTRIS `HILLSIDE CREEPER`HILLSIDE CREEPER SCOTCH PINE3 GAL.PLPHYSOCARPUS OPULIFOLIUS `LITTLE DEVIL` TMDWARF NINEBARK2 GAL.PNPHYSOCARPUS OPULIFOLIUS `SUMMER WINE`SUMMER WINE NINEBARK3 GAL.PPPINUS MUGO VAR. `PUMILIO`MUGO PINE5 GAL.RGRHUS AROMATICA `GRO-LOW`GRO-LOW FRAGRANT SUMAC2 GAL.SMSALVIA X SYLVESTRIS `MAINACHT`MAY NIGHT SALVIA1 GAL.SSSCHIZACHYRIUM SCOPARIUM `THE BLUES`THE BLUES LITTLE BLUESTEM1 GAL.PLANT SCHEDULENOTFORCONSTRUCTIONPURPOSESPROJECT NO.DATE:DRAWN BY:CHECKED BY:DRAWING NO.:REVISIONSPROJECT: SHEET TITLE:19019BEEHIVE FEDERAL CREDIT UNION 5968 N LINDER RD.03.25.2020DTDMTANEW BUILDING FOR: MERIDIAN, IDAHO 83646 TLG PN:119189NOTES:1.THE STAKING OF TREES IS TO BE THE CONTRACTOR'S OPTION; HOWEVER, THE CONTRACTOR ISRESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAINSTRAIGHT FOR A MINIMUM OF 1 YEAR. ALL STAKING SHALL BE REMOVED AT THE END OF THE ONEYEAR WARRANTY PERIOD.2.IN THE EVENT OF A QUESTION OR LACK OF CLARITY ON THE DRAWINGS, THE CONTRACTOR IS TONOTIFY THE LANDSCAPE ARCHITECT BEFORE PROCEEDING.3.LANDSCAPE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT AND OWNER PRIOR TOINSTALLATION OF PLANT MATERIAL.4.WRAP RUBBER CINCH TIES AROUND THE TREE TRUNKS AND STAKES USING EITHER THESTANDARD OR FIGURE EIGHT TYING METHOD. SECURE THE TIES TO THE STAKES WITHGALVANIZED NAILS TO PREVENT SLIPPAGE.5.WATER TREE TWICE WITHIN THE FIRST 24 HOURS.6.IN THE EVENT HARDPAN SOILS PREVENT TREE PLANTING AS DETAILED, NOTIFY THE LANDSCAPEARCHITECT IMMEDIATELY.PREVAILING WIND DIRECTIONREMOVE DEAD/DAMAGED BRANCHES AND PRUNE TOINTERNATIONAL SOCIETY OF ARBORICULTURE STANDARDS;IMPROPERLY PRUNED TREES (AS DETERMINED BY THELANDSCAPE ARCHITECT) SHALL BE REMOVED AND REPLACED.SET ROOTBALL ON NATIVE UNDISTURBED SUBSOILCOMMERCIAL SLOW RELEASE FERTILIZER TABLETSBACKFILL WITH SOIL PLANTING MIX. SEESPECIFICATIONS FOR ADDITIONAL INFORMATION.MULCH LAYER, KEEP MULCH 3" AWAY FROMTRUNK2" x 2" x 8' CEDAR STAKE - DO NOT PENETRATE ROOTBALL.SEE NOTE 1. SET STAKES PARALLEL TO PREVAILING WIND.RUBBER CINCH TIEFINISH GRADEROOT PROBESOIL LINEUTILIZE SOIL/ROOT PROBE AROUND TRUNK(APPROX. 3-4" AWAY FROM TRUNK) TO LOCATEHIGHEST ROOTS. HIGHEST ROOTS SHOULD BEPOSITIONED AT OR SLIGHTLY ABOVE GRADE LEVEL.REMOVE BURLAP, TWINE, AND WIRE BASKET FROM TOP12 OF ROOTBALL, REMOVE ALL NAILS, TIES, AND PLASTICFROM ROOTBALL. IF SYNTHETIC BURLAP IS UTILIZED TOWRAP THE ROOTBALL, IT SHALL BE COMPLETELYREMOVED. ONLY BIODEGRADEABLE BURLAP SHALL BELEFT ON THE BOTTOM OF THE ROOTBALL.2x ROOTBALL DIAMETER3x ROOTBALL DIAMETER6"TREE WRAP TRUNK PROTECTION,REMOVE AFTER INSTALLATION3"1Deciduous Tree PlantingScale: NTSNOTES:1.THE STAKING OF TREES IS TO BE THE CONTRACTOR'S OPTION; HOWEVER, THE CONTRACTOR ISRESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAINSTRAIGHT FOR A MINIMUM OF 1 YEAR. ALL STAKING SHALL BE REMOVED AT THE END OF THE ONEYEAR WARRANTY PERIOD.2.IN THE EVENT OF A QUESTION OR LACK OF CLARITY ON THE DRAWINGS, THE CONTRACTOR IS TONOTIFY THE LANDSCAPE ARCHITECT BEFORE PROCEEDING.3.LANDSCAPE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT AND OWNER PRIOR TOINSTALLATION OF PLANT MATERIAL.4.WRAP RUBBER CINCH TIES AROUND THE TREE TRUNKS AND STAKES USING EITHER THE STANDARD ORFIGURE EIGHT TYING METHOD. SECURE THE TIES TO THE STAKES WITH GALVANIZED NAILS TOPREVENT SLIPPAGE.5.WATER TREE TWICE WITHIN THE FIRST 24 HOURS.6.IN THE EVENT HARDPAN SOILS PREVENT TREE PLANTING AS DETAILED, NOTIFY THE LANDSCAPEARCHITECT IMMEDIATELY.PREVAILING WIND DIRECTIONREMOVE DEAD/DAMAGED BRANCHES AND PRUNE TOINTERNATIONAL SOCIETY OF ARBORICULTURE STANDARDS;IMPROPERLY PRUNED TREES (AS DETERMINED BY THELANDSCAPE ARCHITECT) SHALL BE REMOVED AND REPLACED.SET ROOTBALL ON NATIVE UNDISTURBED SUBSOILCOMMERCIAL SLOW RELEASE FERTILIZER TABLETSBACKFILL WITH SOIL PLANTING MIX. SEESPECIFICATIONS FOR ADDITIONAL INFORMATION.MULCH LAYER, KEEP MULCH 3" AWAY FROMTRUNK2" x 2" x 8' CEDAR STAKE - DO NOT PENETRATE ROOTBALL.SEE NOTE 1. SET STAKES PARALLEL TO PREVAILING WIND.RUBBER CINCH TIEFINISH GRADEROOT PROBESOIL LINEUTILIZE SOIL/ROOT PROBE AROUND TRUNK(APPROX. 3-4" AWAY FROM TRUNK) TO LOCATEHIGHEST ROOTS. HIGHEST ROOTS SHOULD BEPOSITIONED AT OR SLIGHTLY ABOVE GRADE LEVEL.REMOVE BURLAP, TWINE, AND WIRE BASKET FROM TOP12 OF ROOTBALL, REMOVE ALL NAILS, TIES, AND PLASTICFROM ROOTBALL. IF SYNTHETIC BURLAP IS UTILIZED TOWRAP THE ROOTBALL, IT SHALL BE COMPLETELYREMOVED. ONLY BIODEGRADEABLE BURLAP SHALL BELEFT ON THE BOTTOM OF THE ROOTBALL.2x ROOTBALL DIAMETER3x ROOTBALL DIAMETER3"2Coniferous Tree PlantingScale: NTS4" MIN. DEPTH BACKFILL WITH SOIL PLANTINGMIX. SEE SPECIFICATIONS FORADDITIONAL INFORMATION.WATER RETENTIONBASINMULCH LAYERCOMMERCIALFERTILIZER TABLETS3Shrub PlantingScale: NTSNOTES:1. NOTIFY LANDSCAPE ARCHITECT WHEN PLACING BOULDERS FOR APPROVAL.2. PLACE BOULDERS PRIOR TO INSTALLATION OF IRRIGATION SYSTEM.3. CLEAN ALL BOULDERS OF DIRT AND LOOSE DEBRIS.4. WHEN PLACING BOULDERS, BURY 1/4 TO 1/3 OF BOULDER BELOW FINISH GRADE.5. DO NOT SCAR OR DAMAGE BOULDERS.FINISH GRADECOMPACTED SUBGRADE ASREQUIREDBOULDER, LOCATED, SIZE AND TYPE PERPLANS.SHRUB4Boulder InstallationScale: NTSFile Location:g:\2019\119189\cad\119189 cd l100 landscape plan.dwgLast Plotted By:david duperaultDate Plotted:Wednesday, March 25 2020 at 03:30 PM L1.50Landscape Details TRANSFORMER DUMPSTERPAD 4''SS4''SS4''SS4''SS4''SS4''SSMWSDSDEPEPCOCOCOCOCOGMTRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRR/WR/WR/W WWMTRWVSIVGFEEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPEPUGP STUBIRRIRRPIPEIE(N)15"PVC:2572.26'PIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRRPIRR LINDER ROAD UNNAMED ACCESS DRIVE LINDER ROAD UNNAMED ACCESS DRIVE34"19.981"1211.51"237.761"347.461"455.431"567.021"675.701"783.461"892.251"9102.991"10116.081"11124.721"121312.21"13C 34"34"34"1"34"34"34"34"34"34"1"1"34"34"34"34"1"34"1234"34"334"34"34"34"1"1"Keynotes:1.FIELD LOCATE 34" PRESSURE IRRIGATION STUB IN THIS APPROXIMATE LOCATION.CONNECT MAINLINE AND EXTEND AS SHOWN ON PLANS.2.INSTALL IRRIGATION CONTROLLER IN A PAINTED METAL ENCLOSURE IN THISAPPROXIMATE LOCATION. IRRIGATION CONTRACTOR SHALL PROVIDE ALL REQUIREDELECTRICAL CONNECTIONS REQUIRED FOR A FULLY OPERATIONAL SYSTEM.CONTRACTOR SHALL CONNECT ALL LOW VOLTAGE AND 120 VOLT POWER WIRES.ALL ABOVE GRADE WIRES SHALL BE LOCATED IN RIGID STEEL CONDUIT. INSTALL (2)BLUE 14 GAUGE WIRES FROM THE CONTROLLER TO THE LAST VALVE FROM EACHCONTROLLER FOR FUTURE USE.3.1" CONDUIT THROUGH MECHANICAL ENCLOSURE WALL TO ACCOMMODATEELECTRICAL AND DATA CONNECTIONS FOR IRRIGATION CONTROLLER. COORDINATEWITH ARCHITECTURAL PLANS.CALLOUT NUMBERS COORDINATEDTO NUMBERED NOTES BELOW.#Sheet Notes:A.REFER TO IRRIGATION NOTES AND SCHEDULE, SHEET L2.50.NOTFORCONSTRUCTIONPURPOSESPROJECT NO.DATE:DRAWN BY:CHECKED BY:DRAWING NO.:REVISIONSPROJECT: SHEET TITLE:19019BEEHIVE FEDERAL CREDIT UNION 5968 N LINDER RD.03.25.2020DTDMTANEW BUILDING FOR: MERIDIAN, IDAHO 83646 TLG PN:119189Horizontal Scale: 010'20'1" = 10'Irrigation PlanFile Location:g:\2019\119189\cad\119189 cd l200 irrigation plan.dwgLast Plotted By:david duperaultDate Plotted:Wednesday, March 25 2020 at 03:30 PM L2.00Irrigation Plan SYMBOLMANUFACTURER/MODEL/DESCRIPTIONPSIDETAILHUNTER PROS-04-PRS30-CV ADJUSTABLE ARCTURF SPRAY, 30 PSI REGULATED 4.0" POP-UP. WITH FACTORY INSTALLEDDRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANTMATERIAL.302/L2.51SYMBOLMANUFACTURER/MODEL/DESCRIPTIONDETAILHUNTER PCZ-101-25DRIP CONTROL VALVE KIT. 1" PGV GLOBE VALVE WITH 1" HY100 FILTERSYSTEM. PRESSURE REGULATION: 25PSI. FLOW RANGE: 0.5 GPM TO 15GPM. 150 MESH STAINLESS STEEL SCREEN.3/L2.51AREA TO RECEIVE DRIPLINENETAFIM TLCV-06-18TECHLINE PRESSURE COMPENSATING LANDSCAPE DRIPLINE WITH CHECKVALVE. 0.6 GPH EMITTERS AT 18" O.C. DRIPLINE LATERALS SPACED AT18" APART, WITH EMITTERS OFFSET FOR TRIANGULAR PATTERN. 17MM.4/L2.51SYMBOLMANUFACTURER/MODEL/DESCRIPTIONDETAILHUNTER PGV-101G1" PLASTIC ELECTRIC REMOTE CONTROL VALVE, FOR RESIDENTIAL/LIGHTCOMMERCIAL USE. FEMALE NPT INLET/OUTLET. GLOBE CONFIGURATION,WITH FLOW CONTROL.1/L2.51HUNTER HQ-44RCQUICK COUPLER VALVE, YELLOW RUBBER COVER, RED BRASS ANDSTAINLESS STEEL, WITH 1" NPT INLET, 2-PIECE BODY.6/L2.50SHUT OFF VALVE4/L2.50DRAIN VALVE5/L2.50HUNTER I2C-1600-PL16 STATION OUTDOOR MODULAR CONTROLLER. WITH ONE ICM-800MODULE. COMMERCIAL USE. PLASTIC CABINET.7/L2.50BC SUBDIVISION PRESSURE LINE STUB / POINT OF CONNECTION1/L2.50IRRIGATION LATERAL LINE: PVC SCHEDULE 40PVC SCH. 40 PIPE SHALL BE USED WITH SOLVENT WELD SCH. 40 FITTINGSFROM 1/2" - 2-1/2" PIPE SIZES. ALL PIPE 3" AND ABOVE SHALL BE CLASS200 WITH DUCTILE JOINT RESTRAIN FITTINGS BY LEEMCO.2/L2.50IRRIGATION MAINLINE: PVC SCHEDULE 40PVC SCH. 40 PIPE SHALL BE USED WITH SOLVENT WELD SCH. 40 FITTINGSFROM 1/2" - 2-1/2" PIPE SIZES. ALL PIPE 3" AND ABOVE SHALL BE CLASS200 WITH DUCTILE JOINT RESTRAIN FITTINGS BY LEEMCO.2/L2.50PIPE SLEEVE: PVC CLASS 200 SDR 21PIPE SLEEVE SHALL BE TWICE THE SIZE OF DESIGNED PIPE DIAMETER FORMAINLINE AND 4" FOR LATERAL LINES. INSTALL ADDITIONAL 2" SLEEVE ATALL MAINLINE SLEEVES FOR CONTROL WIRES OR WHERE CONTROL WIRELEAVES MAINLINE ROUTE.3/L2.50CValve NumberValve SizeValve FlowValve Callout###"IRRIGATION SCHEDULEA.SYSTEM DESIGN BASED ON THE ASSUMPTION OF THE AVAILABILITY OF 15G.P.M. AND 60 P.S.I.B.CONTRACTOR TO VERIFY LOCATION OF ALL UTILITIES PRIOR TO INITIATIONOF ANY DEMOLITION OR CONSTRUCTION OPERATIONS. ANY DAMAGE TOEXISTING UTILITIES SHALL BE CONTRACTOR'S RESPONSIBILITY.C.COORDINATE ALL IRRIGATION INSTALLATION OPERATIONS WITH CIVIL,MECHANICAL, AND ELECTRICAL ENGINEERING SHEETS.D.CONTRACTOR TO COORDINATE INSTALLATION OF IRRIGATION CONDUITAND SLEEVES UNDER HARD SURFACES WITH RESPECTIVE CONTRACTORS.E.ALL SLEEVES TO BE INSTALLED AS PART OF IRRIGATION CONTRACT.APPROXIMATE LOCATION OF SLEEVES ARE SHOWN ON THE IRRIGATIONPLAN. FIELD VERIFY LOCATION. ALL ENDS OF SLEEVES TO BE TAPED ORCAPPED AND MARKED WITH A 2"X 4" PAINTED STAKE EXTENDING TO 24"ABOVE GRADE. STAKES ARE NOT TO BE REMOVED UNTIL THE IRRIGATIONSYSTEM IS COMPLETE. ALL SLEEVES SHALL EXTEND A MINIMUM OF 18"BEYOND BACK OF CURB OR EDGE OF PAVEMENT. PROVIDE COMPACTEDBACKFILL.F.CONTRACTOR TO OBTAIN AND PAY FOR ALL PERMITS AND FEES REQUIREDFOR THIS WORK.G.IRRIGATION CONTROLLER(S) ARE TO BE LOCATED AS SHOWN ON PLAN.CONTROLLERS SHALL BE WIRED TO POWER SUPPLY BY A LICENSEDELECTRICIAN PER LOCAL CODES. IRRIGATION CONTRACTOR TO PROVIDEALL REQUIRED CONNECTIONS TO 24 VOLT IRRIGATION CONTROL WIREINSIDE THE BUILDINGS THROUGH APPROPRIATE SIZED CONDUIT.H.ALL ELECTRICAL WORK TO MEET OR EXCEED N.E.C., STATE CODES, LOCALCODES, AND MANUFACTURER'S RECOMMENDATIONS.I.CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL ROCK AND DEBRISBROUGHT TO THE SURFACE AS A RESULT OF TRENCHING OPERATIONS.J.CONTRACTOR SHALL REFER TO SPECIFICATIONS AND DETAIL DRAWINGSFOR ADDITIONAL REQUIREMENTS.K.ALL 24 VOLT POWER WIRES SHALL BE #14 AWG COPPER. ALL ABOVEGROUND 120 VOLT AND 24 VOLT WIRE SHALL BE IN PVC CONDUIT. ALL 24VOLT WIRES SHALL BE TAPED TOGETHER AT TEN FOOT (10'-0")INTERVALS.L.INSTALLATION SHALL COMPLY WITH ALL NATIONAL, STATE, AND LOCALLAWS AND ORDINANCES.M.IRRIGATION CONTRACTOR SHALL PROVIDE AN AS-BUILT IRRIGATION PLANUPON COMPLETION OF INSTALLATION AND PRIOR TO FINAL PAYMENT.N.THE ENTIRE SYSTEM SHALL BE GUARANTEED TO BE COMPLETE ANDSOUND IN EVERY DETAIL FOR A PERIOD OF ONE YEAR FROM THE DATE OFITS ACCEPTANCE; REPAIR OR REPLACEMENT OF ANY DEFECTSOCCURRING WITHIN THAT YEAR SHALL BE FREE OF EXPENSE TO THEOWNER.O.AS PART OF THIS CONTRACT, PERFORM AT NO EXTRA COSTWINTERIZATION AND SPRING START UP OF THE SYSTEM DURING THEGUARANTEE PERIOD.P.ALL MATERIALS SHALL BE NEW AND WITHOUT FLAWS OR DEFECTS OFTHE QUALITY AND PERFORMANCE SPECIFIED, AND SHALL MEET THEREQUIREMENTS OF THIS SYSTEM. USE MATERIALS AS SPECIFIED, NOSUBSTITUTIONS SHALL BE PERMITTED WITHOUT PRIOR WRITTENPERMISSION OF THE OWNER.Q.IRRIGATION CONTRACTOR SHALL MAKE NECESSARY MINOR FIELDADJUSTMENTS TO SPRINKLER NOZZLES, SPRINKLERS, PIPE, AND OTHERIRRIGATION EQUIPMENT LOCATIONS TO FIT THE AS-BUILT SITE. ADJUSTHEAD AND PIPE LOCATIONS AS REQUIRED TO AVOID DAMAGING EXISTINGTREE ROOTS. ADJUSTMENTS SHALL ENSURE HEAD TO HEAD COVERAGE.R.IRRIGATION PIPING LAYOUT IS SCHEMATIC. WHERE LINES ARE SHOWNBELOW PAVEMENT ADJACENT TO LANDSCAPE AREAS, THEY ARE TO BELOCATED IN THE LANDSCAPE AREA UNLESS SHOWN WITH A SLEEVESYMBOL.R.A.IRRIGATION MAINLINE SHALL BE SLEEVED UNDER ALL HARDSCAPE.SLEEVING MAY NOT BE SHOWN FOR MAINLINE FOR GRAPHICALPURPOSES.S.LOCATION OF EXISTING EQUIPMENT ARE SCHEMATIC IN NATURE. FIELDVERIFY ALL BASE AND EXISTING IRRIGATION ELEMENTS AND CONDITIONSPRIOR TO CONSTRUCTION AND PROVIDE NECESSARY ADJUSTMENTS.V.IN THE EVENT OF A DISCREPANCY, IMMEDIATELY NOTIFY THE LANDSCAPEARCHITECT.Z.CONTRACTOR SHALL SCHEDULE A MEETING WITH LANDSCAPEARCHITECT AND OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION OFIRRIGATION CONTROL SYSTEM TO DETERMINE PROCEDURES OFINSTALLATION OF IRRIGATION CONTROL SYSTEM.AE.PIPE VELOCITIES SHALL NOT EXCEED 5 FT/SEC.AF.AREAS WHERE FULL CIRCLE HEADS ARE REQUIRED, NON-REVERSINGCIRCLE HEADS SHALL BE INSTALLED. PARTIAL CIRCLE HEADS WITHREVERSING DIRECTION ARE PROHIBITED FOR USE OF 360° ROTATION.Irrigation Notes:A.REMOTE CONTROL VALVES:A.A.INSTALL (1) REMOTE CONTROL VALVE PER VALVE BOX. ENSURE THAT ADEQUATESPACE IS PROVIDED AROUND ENTIRE VALVE FOR EASE OF MAINTENANCE. ROUNDVALVE BOXES ARE NOT PERMITTED.A.B.VALVE BOXES SHALL BE GREEN OR BLACK WITH GREEN LIDS.B.IRRIGATION CONTROL WIRE:B.A.ALL WIRE SPLICES SHALL BE INSTALLED WITH A WATERPROOF WIRE CONNECTORAND DBY/R CAP OR BLAZING NUT WIRE SPLICE CONNECTOR.B.B.ALL WIRE SPLICES SHALL BE LOCATED IN VALVE BOXES AND INDICATED ON AS-BUILTDRAWINGS. PROVIDE AS A MINIMUM, 36" OF EXTRA WIRE AT ALL WIRE SPLICES ANDREMOTE CONTROL VALVE CONNECTIONS.B.C.CONTROL WIRE SHALL BE INSTALLED WITH PROPOSED MAINLINE. IF CONTROL WIRELEAVES PIPING TRENCH, WIRE SHALL BE INSTALLED AT A MINIMUM DEPTH OF 12".C.PIPING (USE THE FOLLOWING):C.A.2-1/2" AND SMALLER: SDR 21 SCH. 40 PVC, SOLVENT-CEMENT JOINTS:C.B.TRENCHES SHALL BE PHOTO DOCUMENTED AND PHOTOS SUBMITTED TO ARCHITECTPRIOR TO BACKFILLING.C.C.TRENCH BACKFILL CONSISTING OF SAND, FINE GRAVEL OR SELECT EARTH FREE OFLARGE LUMPS OR ROCKS LARGER THAN 34" SHALL BE USED IN AND AROUNDINSTALLED PIPE.Irrigation Execution:Drip Irrigation Notes:A.ALL PLANTER BEDS ARE TO BE IRRIGATED WITH DRIP IRRIGATION AS INDICATED ONPLANS. THE CONTRACTOR IS RESPONSIBLE TO INSTALL THE DRIP SYSTEM AS PERMANUFACTURERS RECOMMENDATIONS AND THE FOLLOWING REQUIREMENTS:A.A.EACH DRIP ZONE SHALL RECEIVE A DRIP ZONE CONTROL KIT WITH PRESSUREREGULATION AND 120 MESH (MIN.) STAINLESS STEEL FILTRATION SCREEN.A.B.ALL TUBING IS TO BE STAKED DOWN WITH 6" SOIL STAPLES AT 24" (MIN.)INTERVALS. ALL FITTINGS SHALL RECEIVE (2) STAPLES IN OPPOSING DIRECTIONS.B.IF WEED BARRIER FABRIC IS USED IN LANDSCAPE BEDS, DRIP IRRIGATION SHALL BEINSTALLED UNDERNEATH FABRIC AND STAPLED AS INDICATED ABOVE.C.ALL LATERAL LINES FROM VALVES TO HEADERS ARE TO BE BURIED AT DEPTH INDICATEDIN TRENCH SECTION DETAIL. SIZE AS NECESSARY.D.AFTER INSTALLATION OF THE IRRIGATION SYSTEM THE CONTRACTOR IS RESPONSIBLE TOPROVIDE THE OWNER WITH AS-BUILT DRAWINGS AND INSTRUCTIONS FOR MAINTENANCEOF THE DRIP SYSTEM.NOTFORCONSTRUCTIONPURPOSESPROJECT NO.DATE:DRAWN BY:CHECKED BY:DRAWING NO.:REVISIONSPROJECT: SHEET TITLE:19019BEEHIVE FEDERAL CREDIT UNION 5968 N LINDER RD.03.25.2020DTDMTANEW BUILDING FOR: MERIDIAN, IDAHO 83646 TLG PN:119189POINT OF CONNECTION (PRESSURE IRRIGATION)NTSSCALE:PVCMAINLINEQUICKCOUPLERISOLATIONVALVEDRAINVALVE5L2.502L2.506L2.504L2.501TRENCH SECTIONNTSSCALE:LOCATOR TAPE - 6" DEPTH(PLACED ABOVE MAINLINE ONLY)LATERAL - 12" DEPTHMAINLINE - 18" DEPTHTAPE AND BUNDLE CONTROLWIRE AT 10'-0" O.C. INTERVALS,PLACE TO SIDE OF MAINLINEFINISH GRADE AT TOP OF TRENCH SHALL MATCHSURROUNDING FINISH GRADEFINISH GRADESAND OR ROCK FREE SOILAROUND ALL PIPE18"6"6"6"2MIN. 24" COVERMIN. 18"EXTENSIONPVC LATERAL ORMAINLINEPVC SLEEVE TWICE THE SIZEOF IRRIGATION LATERAL ORMAINLINEPAINTED 2" x 4" STAKEEXTENDED 24" ABOVE GRADESLEEVING SECTIONNTSSCALE:CONTROL WIRE SLEEVE. WIRE SHALLNOT BE RAN IN SAME SLEEVE ASIRRIGATION PIPING.3ISOLATION VALVENTSSCALE:12" ROUND VALVE BOXPAVING BRICK (1 OF 3)6" ADS LENGTH AS REQUIREDLEEMCO SS GATE VALVE WITH CROSS TOP(LGT11SS304X). SIZE THE SAME AS THEMAINLINE IN WHICH IT IS INSTALLED.PVC MAINLINEBRASS UNION2L2.504DRAIN VALVENTSSCALE:FINISH GRADE12" ROUND VALVE BOX(3) PAVING BRICK6" DIA. ADS LENGTHAS REQUIREDLEEMCO SS GATEVALVE WITH CROSSTOP (LGT11SS304X)(2) 4" LONG PVCSCH. 80 NIPPLESCH. 40 ELL TTDRAIN ROCK - 1 C.F.MIN.GEOTEXTILE FABRIC,TOP AND ALL SIDES.12" LONG PVC SCH.80 NIPPLESCH. 40 PVC TEE(SST)3" 2 L2.505 3"MIN.90° STREET ELLS(LASCO SWING JOINT)SCH. 40 FITTINGS(LASCO SWING JOINT)12" ROUND VALVE BOXQUICK COUPLER VALVEWITH COVERFINISH GRADEFILTER FABRIC BARRIERLASCO SNAPLOK STABILIZER6" DEEP PEA GRAVELREBAR THROUGH SNAPLOKSCH. 80 NIPPLEMAINLINE90° STREET ELLS(LASCO SWING JOINT)SCH. 80 NIPPLE(LASCO SWING JOINT)QUICK COUPLER VALVENTSSCALE:2 L2.506BUILDING WALLAUTOMATIC IRRIGATIONSPRINKLER CONTROLLER2" RIGID STEEL PIPEMIN.2" FROM WALL(1) FOR CONTROL WIRES(1) FOR GROUNDINGWIRESJUNCTION BOX - CAULKBOTH SIDESFINISH GRADE2" RIGID STEEL PIPE ELBOW(12" RADIUS MIN.)DIRECT BURIAL CONTROL ANDCOMMON WIRES TO CONTROLVALVES 18" MIN.BUILDING FOUNDATION5'IRRIGATION CONTROLLER - EXTERIOR WALL MOUNTNTSSCALE:7File Location:g:\2019\119189\cad\119189 cd l200 irrigation plan.dwgLast Plotted By:david duperaultDate Plotted:Wednesday, March 25 2020 at 03:30 PM L2.50Irrigation Details NOTFORCONSTRUCTIONPURPOSESPROJECT NO.DATE:DRAWN BY:CHECKED BY:DRAWING NO.:REVISIONSPROJECT: SHEET TITLE:19019BEEHIVE FEDERAL CREDIT UNION 5968 N LINDER RD.03.25.2020DTDMTANEW BUILDING FOR: MERIDIAN, IDAHO 83646 TLG PN:119189REMOTE CONTROL VALVENTSSCALE:FILTER FABRIC BARRIER ON SIDESAND BOTTOM OF VALVE BOX.6" DEPTH PEA GRAVEL SUMPBRICK PAVERS (1 OF 4)SCH. 80 NIPPLE. LENGTH ASREQUIRED (TYP.). PVC SCH. 40 ELBOW (TT) TOSCH. 80 NIPPLE.REMOTE CONTROL VALVEPER PLANSNOTE:1.ALL PVC FITTINGS SHALL BE SCH. 40 UNLESS OTHERWISE NOTED.2.REFER TO TRENCH SECTION FOR MAINLINE AND LATERAL DEPTHS.3.CENTER REMOTE CONTROL VALVE ASSEMBLY IN VALVE BOX. ONLY ONE VALVE SHALL BE INSTALLED PER BOX. A MINIMUMOF 3" CLEARANCE SHALL BE PROVIDED ON ALL SIDES OF REMOTE CONTROL VALVE.4.INSTALL SCH. 80 REDUCER IMMEDIATELY DOWN STREAM OF REMOTE CONTROL VALVE AND NIPPLE TO ACHIEVESPECIFIED LATERAL SIZE ON PLANS.3M DBY-R SPLICE KIT WITHTWIST-ON CONNECTORS, ORAPPROVED EQUAL.SOLVENT WELD BELLEND PVC PIPE TO SCH.80 NIPPLE, CUTTHREADS OFF GLUEDEND.3" MIN.3" MIN.5" MAX.CONTROL WIRE. TAPE TO MAINLINEIN 10' INTERVALS.HEAVY DUTY VALVE BOX,20" x 13" MIN.FINISH GRADE SCH. 80 PVC UNION WITH SCH. 80NIPPLE, LENGTH AS REQUIRED. SCH. 80 PVC UNION WITHSCH. 80 NIPPLE BOTHSIDES, LENGTH ASREQUIRED.12" MAX.BACK OF WALKOR CURB90° ELBOW SPIRALBARB FITTINGSPVC LATERAL LINEFINISH GRADEINSTALL 1/4" ABOVE GRADEPOP-UP SPRAY HEADLINEAR LOW DENSITY POLYETHYLENESWING PIPE (24" LONG MAX.)SCH. 40 TEE (SST) OR ELBOW (ST)SPRAY HEAD SPRINKLERNTSSCALE:MARLEX STREET ELBOW2L2.502 2 1 FINISH GRADEFILTER FABRIC BARRIER ON SIDESAND BOTTOM OF VALVE BOX.6" DEPTH PEA GRAVEL SUMPBRICK PAVERS (1 OF 4)SCH. 80 NIPPLE. LENGTH ASREQUIRED (TYP.).SCH. 40 PVC EL. (TT). CONNECTWITH SCH. 80 NIPPLES (BOTH SIDES).LENGTH AS REQUIRED.DRIP ZONE VALVE KIT PER PLANSCHRISTY VALVE ID TAG.NOTES:1.ALL PVC FITTINGS SHALL BE SCH. 40 UNLESS OTHERWISE NOTED.2.VALVE ID TAGS SHALL MATCH VALVE NUMBER ASSIGNED TO VALVE ON PLANS, UNLESS APPROVED BY ARCHITECT. TAGSSHALL HAVE DIGITAL LETTERING/NUMBERING ONLY.3.REFER TO TRENCH SECTION FOR MAINLINE AND LATERAL DEPTHS.4.CENTER DRIP ZONE KIT ASSEMBLY IN VALVE BOX. ONLY ONE VALVE SHALL BE INSTALLED PER BOX. A MINIMUM OF 3"CLEARANCE SHALL BE PROVIDED ON ALL SIDES OF ANGLE VALVE AND DRIP ZONE KIT ASSEMBLY.5.INSTALL SCH. 80 REDUCER IMMEDIATELY DOWN STREAM OF REMOTE CONTROL VALVE AND NIPPLE TO ACHIEVESPECIFIED LATERAL SIZE ON PLANS.6.ALL DRIP ZONES SHALL HAVE A FILTER WITH STAINLESS STEEL SCREEN AT A 120 MESH (MIN.).3M DBY-R SPLICE KITWITH TWIST-ONCONNECTORS, ORAPPROVED EQUAL.SOLVENT WELD BELLEND PVC PIPE TO SCH.80 NIPPLE, CUTTHREADS OFF GLUEDEND.CONTROL WIRES. TAPE TO MAINLINEIN 10' INTERVALS.HEAVY DUTY VALVEBOX, 20" x 13" (MIN.).INCREASE AS NEEDEDTO PROVIDECLEARANCES STATEDIN NOTES.DRIPLINE REMOTE CONTROL VALVENTSSCALE:3" MIN.5" MAX.3" MIN.SCH. 80 UNION WITHSCH. 80 NIPPLESDOWNSTREAM.SCH. 80 UNION WITH SCH. 80NIPPLES BOTH SIDES.3FVDRIP REMOTE CONTROL VALVEDRIPLINE LAYOUTNTSSCALE:PVC SUPPLY HEADERROW SPACING PER PLANPERIMETER LATERALS4" FROM EDGEPVC SUPPLY HEADER2" MIN.,6" MAXFINISH GRADE (TOP SOIL)PLAN VIEWSECTIONNOTE:1.DRIP IRRIGATION SHALL BE PLACED UNDERWEED BARRIER AND MULCH.FINISH GRADE (MULCH)STAPLE ALL TEES,ELLS, AND 2" O.C.WIDTH PER PLAN6L2.515L2.5144" MIN./6" MAX.FINISH GRADENETAFIM LINE FLUSHVALVE (TLSOV)10" ROUND VALVE BOX(3) BRICK SUPPORTSGRAVEL SUMP (1 CUBIC FOOT)DRIP TUBING PER PLANDRIP FLUSH VALVENTSSCALE:5FINISH GRADE (MULCH)FINISH GRADE (TOPSOIL)17 MM ELBOWDRIPLINE17MM FEEDER TUBING,LENGTH AS REQUIRED34" MALE ADAPTERPVC TEE (SST)PVC LATERAL - REFERTO TRENCH DETAIL FORDEPTH.DRIPLINE LATERAL CONNECTIONNTSSCALE:6File Location:g:\2019\119189\cad\119189 cd l200 irrigation plan.dwgLast Plotted By:david duperaultDate Plotted:Wednesday, March 25 2020 at 03:30 PM L2.51Irrigation Details