Loading...
Landscape Plan707 SFPARTS111505 SFRECEPTION100 59 SFSERVER104113 SFFRM. OFF .105150 SFSRV. WR IT .102158 SFSR. MGR .101208 SFCONF.106182 SFBREAK.107192 SFR.R .10979 SFR.R .10810178 SFSHOP112807 SFSTEAM CLEANER113880 SFPUMP TEST115101 SFLOCKERS11074 SFSTEAMSTOR.11431 SFUTIL .103(E) MERIDIAN CITY PATHWAY EASEMENT(E) PRESSURE IRRIGATION EASEMENTN 64°49'39" E 277.37'N 25°10'21" W 343.46'N 58 °49 '48 " E 205 .79 'S 29°40'40" E 372.95'W NEL IS DR (E) PATHWAY AND FENCELINE TO BE RETA INED PROPOSED BUILDNIG1.11.31.11.21.21.21.2234555666676" CAL. ASH8" CAL. CRABAPPLE88PN (3)LE (3)AW (1)AW (1)(1) PLPS (7)CO (3)CO (5)PM (5)CO (5)PM (5)RA (6)PS (2)PL (1)PL (20)PS (3)PS (3)PL (3)PL (12)PL (2)PS (1)AW (1)(1) PL(4) RA(3) LE(5) PMCO (5)PM (5)(5) CO(3) PN(3) CO(11) PSPL (6)PS (6)PL (6)JM (6)RA (3)PH (1)PS (1)AW (1)PL (3)PS (1)AW (1)PL (8)(1) PS(1) AW(3) PL(1) PL(2) PH(1) FOPL (2)(2) PM(1) RAPB (1)PM (3)RA (1)PB (1)UTILITY EASEMENTUTILITY EASEMENT10" CAL. CRABAPPLE8" CAL. CRABAPPLE8" CAL. CRABAPPLE10" CAL. CRABAPPLE8" CAL. CRABAPPLEVISION TRIANGLE PER11-3A-3.B.1.2, TYP.Keynotes:1.SITE FENCING - REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION.1.1.TYPE 1.1.2.TYPE 2.1.3.TYPE 3.2.TRASH ENCLOSURE - REFER TO ARCHITECTURAL DRAWINGS FOR MOREINFORMATION.3.FLAG POLE - REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION.4.BIKE RACK - REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION.5.ROOF OVERHANG - REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION.6.CONCRETE EDGING - SEE DETAIL 1/L150.7.APPROXIMATE LOCATION OF EXISTING TRANSFORMER. FIELD VERIFY.8.DRY CREEK - SEE DETAIL 6/L150.CALLOUT NUMBERS COORDINATEDTO NUMBERED NOTES BELOW.Material Legend:4"-DEPTH BLACK AND TANROCK MULCH.LARGE BASALT BOULDERS,3'-4' DIA. TYP. SEE DETAIL -5/L150#TURF SOD.4"-DEPTH GRAVEL.EXISTING TREE, RETAINAND PROTECT.EXISTING TREE, REMOVEAND DISPOSE OF OFFSITE.2"-6" WASHED RIVERCOBBLE MULCH - SEEDETAIL 6/L150.Project Calculations:A.STREET TREESW. NELIS DR - 10' BUFFER @ 188 LFREQUIRED: 5 TREESPROVIDED: 5 EXISTING/1 PROPOSED TREE.(EXCLUDES AREAS IN UTILITY EASEMENTS)B.PERIMETER PARKING:REQUIRED: 6 TREESPROVIDED: 6 TREES(EXCLUDES AREAS IN UTILITY EASEMENTS)C.PATHWAY TREESREQUIRED: 3 TREESPROVIDED: 8 EXISTING TREES TO REMAIND.TREE MITIGATIONTOTAL CALIPER SIZE OF EXISTING TREES TO BE REMOVED: 15"TOTAL CALIPER SIZE OF PROPOSED TREES:16"(EXCLUDED CODE REQUIRED PARKING, STREET, AND PATHWAY BUFFER TREES)TREESCODEBOTANICAL / COMMON NAMESIZECONTAINERQTYAWACER TRUNCATUM X PLATANOIDES `KEITHSFORM` TMNORWEGIAN SUNSET MAPLE2" CAL.B&B6FOFRAXINUS OXYCARPA `RAYWOOD` TMRAYWOOD ASH2" CAL.B & B1LELIRIODENDRON TULIPIFERA `EMERALD CITY` TMEMERALD CITY TULIP TREE2" CAL.B&B6EVERGREEN TREESCODEBOTANICAL / COMMON NAMESIZECONTAINERQTYPBPICEA OMORIKA `BRUNS`BRUNS SPRUCE8` HT.B & B2PNPINUS NIGRAAUSTRIAN BLACK PINE8` HT.B&B6SHRUBSCODEBOTANICAL / COMMON NAMESIZECONTAINERQTYCOCHAENOMELES SPECIOSA `ORANGE STORM`ORANGE STORM FLOWERING QUINCE3 GAL26JMJUNIPERUS SCOPULORUM `MEDORA`MEDORA JUNIPER5 GAL.6PHPINUS SYLVESTRIS `HILLSIDE CREEPER`HILLSIDE CREEPER SCOTCH PINE3 GAL.3PLPOTENTILLA FRUTICOSA `LUNDY`HAPPY FACE BUSH CINQUEFOIL3 GAL.69PMPINUS MUGO `MOPS`MOPS MUGO PINE3 GAL.25PSPINUS MUGO `SLOWMOUND`MUGO PINE3 GAL36RARHUS AROMATICA `AUTUMN AMBER`AUTUMN AMBER SUMAC3 GAL.15PLANT SCHEDULEA.CONTRACTOR SHALL REPORT TO LANDSCAPE ARCHITECT ALL CONDITIONS WHICH IMPAIR AND/OR PREVENT THE PROPEREXECUTION OF THIS WORK, PRIOR TO BEGINNING WORK.B.FINISH GRADES TO BE SMOOTH AND EVEN GRADIENTS WITH POSITIVE DRAINAGE IN ACCORDANCE WITH SITE GRADING PLAN.REMOVE RIDGES AND FILL DEPRESSIONS, AS REQUIRED TO MEET FINISH GRADES. PLACE 4" OF MULCH OVER SUBGRADE SOILTO ACHIEVE FINISH GRADE - SEE MATERIAL LEGEND FOR MORE INFORMATION. FINISH GRADE RELATED TO ADJACENT SITEELEMENTS SHALL BE:B.A.1-INCH BELOW TOP OF ADJACENT PAVEMENT, VALVE BOX, VAULT, ETC.B.B.3-INCHES BELOW TOP OF CURB UNLESS NOTED OTHERWISE.C.ALL PLANTING BEDS SHALL HAVE A MINIMUM OF 18" OF TOPSOIL, SOD AREAS A MINIMUM OF 12" OF TOPSOIL. SPREAD,COMPACT AND FINE GRADE TOPSOIL TO A SMOOTH AND UNIFORM GRADE.D.RE-USE EXISTING SURFACE TOPSOIL WHERE POSSIBLE. VERIFY SUITABILITY OF SURFACE SOIL TO PRODUCE TOPSOIL MEETINGREQUIREMENTS AND AMEND WHEN NECESSARY. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREE OFTOXIC MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS OR OTHER FOREIGN MATERIAL AND A PH OF 5.5 TO 7.0. IFON-SITE TOPSOIL DOES NOT MEET THESE MINIMUM STANDARDS, CONTRACTORS ARE RESPONSIBLE TO EITHER: A) PROVIDEAPPROVED IMPORTED TOPSOIL, OR B.) IMPROVE ON-SITE TOPSOIL WITH METHODS APPROVED BY LANDSCAPE ARCHITECT.SUPPLEMENT WITH IMPORTED TOPSOIL WHEN QUANTITIES ARE INSUFFICIENT. CLEAN TOPSOIL OF ROOTS, PLANTS, SODS,STONES, CLAY LUMPS AND OTHER EXTRANEOUS MATERIALS HARMFUL TO PLANT GROWTH.E.IF IMPORTED TOPSOIL FROM OFF-SITE SOURCES IS REQUIRED, PROVIDE NEW TOPSOIL THAT IS FERTILE, FRIABLE, NATURALLOAM, SURFACE SOIL, REASONABLY FREE OF SUBSOIL, CLAY LUMPS, BRUSH, WEEDS AND OTHER LITTER, AND FREE OF ROOTS,STUMPS, STONES LARGER THAN 2 INCHES IN ANY DIMENSION, AND OTHER EXTRANEOUS OR TOXIC MATTER HARMFUL TOPLANT GROWTH.F.OBTAIN TOPSOIL FROM LOCAL SOURCES OR FROM AREAS HAVING SIMILAR SOIL CHARACTERISTICS TO THAT FOUND ATPROJECT SITE. OBTAIN TOPSOIL ONLY FROM NATURALLY, WELL-DRAINED SITES WHERE TOPSOIL OCCURS IN A DEPTH OF NOTLESS THAN 4 INCHES.G.ALL LANDSCAPE AREAS SHALL BE WEED FREE AT THE TIME OF LANDSCAPE INSTALLATION.REMOVE ALL ROOTS, WEEDS,ROCKS AND FOREIGN MATERIAL ON THE SURFACE.H.NEW TREE PLANTING, SEE DETAIL 2&4/L150. CONTRACTOR SHALL STAKE ALL TREES DEEMED NECESSARY, I.E..... FROM BEINGBLOWN OVER, PLANTED WITH LOOSE ROOT BALL, ETC. CONTRACTOR'S OPTION.I.NEW SHRUB PLANTING. SEE DETAIL 3/L150.J.ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR TYPE AND SIZE SHOWN. PLANTSWILL BE REJECTED IF NOT IN A SOUND AND HEALTHY CONDITION.K.ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING AT THE DATE OF SUBSTANTIALCOMPLETION. REPLACE ALL PLANT MATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY WITH THE SAMESIZE AND SPECIES AT NO COST TO THE OWNER.L.TREE PIT BACKFILL PLANTING MIX: BLEND TOPSOIL AND SOIL AMENDMENTS AND FERTILIZER FOR TREE PIT BACKFILL AT THEFOLLOWING RATES. BLEND AMENDMENTS THOROUGHLY WITH SOIL BACKFILL. TREE PITS SHALL BE 5'x5'x1.5' (37.5 CF/ 1.5 CY).L.A.APPLICATION RATES:L.A.A.HUMIC ACID: 25 LBS PER TREE PITL.A.B.COMMERCIAL GRADE COMPOST - 10 CUBIC FEET PER TREE PITL.A.C.PLANTING TABLET FERTILIZER - 4 TABLETS PER TREE PITL.A.D.CALCIFIED DIATOMACEOUS EARTH - 75 LBS PER TREE PITM.SHRUB PIT BACKFILL PLANTING MIX: BLEND TOPSOIL AND SOIL AMENDMENTS AND FERTILIZER FOR SHRUB PIT BACKFILL ATTHE FOLLOWING RATES. BLEND AMENDMENTS WITH THOROUGHLY WITH SOIL BACKFILL. SHRUB PITS SHALL BE 2.5'x2.5'x1'(6.25 CF/ 0.25 CY).M.A.APPLICATION RATES:M.A.A.HUMIC ACID: 2 LBS PER SHRUB PITM.A.B.COMMERCIAL GRADE COMPOST - 2 CUBIC FEET PER SHRUB PITM.A.C.PLANTING TABLET FERTILIZER - 2 TABLETS PER SHRUB PITM.A.D.CALCIFIED DIATOMACEOUS EARTH - 15 LBS PER SHRUB PITN.IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE CREATED FROM LANDSCAPE OPERATIONS AND DISPOSEOF PROPERLY OFF SITE.O.CONTRACTOR SHALL SUBMIT MATERIAL SAMPLES FOR LANDSCAPE ROCK MULCH TO LANDSCAPE ARCHITECT FOR APPROVALPRIOR TO PROCUREMENT. LANDSCAPE BOULDERS, PHOTO SUBMITTAL IS ADEQUATE. FOR ROCK MULCH, SUBMIT 1 GALLONBAG SAMPLE TO OWNER.Landscape Notes:Horizontal Scale: 020'40'1" = 20'Landscape Plan-Planting PlanCLIENT:JOB NUMBERCONSULTANT725 E 2nd StMeridian, ID 83642208.884.2824PROFESSIONAL SEALTHIS DOCUMENT IS THE PROPERTY OFNEUDESIGN ARCHITECTURE, LLC ANDIS NOT TO BE DUPLICATED WITHOUTWRITTEN AUTHORIZATION.© NEUDESIGN ARCHITECTURE LLCDRAWN BYTLG PN: 11920919260LandscapeAuthorNO.DESCRIPTIONDATEHUGHES FIRE EQUIPMENT BUILDING 3396 W NELIS DR. MERIDIAN, ID 83646 RICK TRACY L100Plan01.15.20 A.PROTECT THE CRITICAL ROOT ZONE OF THE TREES TO BE RETAINED ON SITE: (NOTE:CRITICAL ROOT ZONE IS THE AREA DIRECTLY BELOW THE DRIP LINE OF THE TREE.)A.A.CONSTRUCT PROTECTIVE FENCING OF CHAIN-LINK AROUND THE CRITICALROOT ZONE PRIOR TO DEMOLITION OR CONSTRUCTION.A.B.DO NOT ALLOW COMPACTION BY EQUIPMENT TRAFFIC DURINGCONSTRUCTION OR DURING DEMOLITION.A.C.DO NOT ALLOW CEMENT TRUCKS TO RINSE WITHIN THE PROTECTION AREA,ANYWHERE THAT TREE ROOTS EXIST OR IN PLANNED PLANTING BEDS.A.D.DO NOT STOCKPILE MATERIALS, DEBRIS OR DIRT WITHIN THE TREEPROTECTION AREA.A.E.MAINTAIN WATERING WITHIN THE CRITICAL ROOT ZONE FROM MID-APRIL TOMID-OCTOBER AT THE RATE OF NOT LESS THAN THE EQUIVALENT OF 1-1/2" OF WATER OVER THE ENTIRE AREA PER WEEK.A.F.DO NOT TRENCH, EXCAVATE, FILL OR OTHERWISE DISTURB THE SOIL WITHINTHE CRITICAL ROOT ZONE.A.G.ADJUST PROPOSED IMPROVEMENT LOCATIONS AS REQUIRED TO AVOIDDAMAGING TREE ROOTS.B.PROTECT THE CROWN AND TRUNK OF TREES TO BE RETAINED ON SITE:B.A.OPERATE EQUIPMENT IN SUCH A WAY AS TO AVOID CONTACT WITH TREETRUNKS OR BRANCHES.B.B.PRUNING OF PUBLIC PROPERTY TREES SHALL BE PERFORMED BY A LICENSEDARBORIST.C.ALL TREES DAMAGED OR DESTROYED DURING CONSTRUCTION SHALL BEREPLACED PER CITY OF MERIDIAN MUNICIPAL CODE.Tree Protection Notes:A.ALL LANDSCAPED AREAS SHALL HAVE AN AUTOMATIC UNDERGROUND SPRINKLERSYSTEM WHICH ENSURES COMPLETE COVERAGE AND PROPERLY ZONED FORREQUIRED WATER USES.B.EACH HYDROZONE IS TO BE IRRIGATED WITH SEPARATE INDIVIDUAL STATIONS.C.POP-UP SPRINKLER HEADS SHALL HAVE A MINIMUM RISER HEIGHT OF 6" AT LAWNAREAS.D.PLANTER BEDS ARE TO HAVE DRIP IRRIGATION SYSTEMS - WITH DRIP CONTROLZONE KIT AND 150 MESH FILTER (MIN.).E.ELECTRONIC WATER DISTRIBUTION/ TIMING CONTROLLERS ARE TO BE PROVIDED.MINIMUM CONTROLLER REQUIREMENTS ARE AS FOLLOWS:E.A.PRECISE INDIVIDUAL STATION TIMINGE.B.RUN TIME CAPABILITIES FOR EXTREMES IN PRECIPITATION RATESE.C.AT LEAST ONE PROGRAM FOR EACH HYDROZONEE.D.SUFFICIENT MULTIPLE CYCLES TO AVOID WATER RUN-OFFE.E.POWER FAILURE BACKUP FOR ALL PROGRAMMED INDIVIDUAL VALVEDWATERING STATIONS WILL BE DESIGNED AND INSTALLED TO PROVIDEWATER TO RESPECTIVE HYDRO-ZONES.F.INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND INSTALLED TOPROVIDE WATER TO RESPECTIVE HYDRO-ZONES.G.THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE 100% COVERAGE WITHHEAD TO HEAD SPACING OR TRIANGULAR SPACING AS APPROPRIATE.H.SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTOIMPERVIOUS SURFACES SUCH AS SIDEWALKS, DRIVEWAYS, AND PARKING AREA.I.EACH VALVE SHALL BE INSTALLED IN A VALVE BOX LARGE ENOUGH TO ALLOW FORMAINTENANCE AND REMOVAL. ONLY ONE VALVE PER BOX.Automatic Underground Irrigation Notes:CLIENT:JOB NUMBERCONSULTANT725 E 2nd StMeridian, ID 83642208.884.2824PROFESSIONAL SEALTHIS DOCUMENT IS THE PROPERTY OFNEUDESIGN ARCHITECTURE, LLC ANDIS NOT TO BE DUPLICATED WITHOUTWRITTEN AUTHORIZATION.© NEUDESIGN ARCHITECTURE LLCDRAWN BYTLG PN: 11920919260LandscapeAuthorNO.DESCRIPTIONDATEHUGHES FIRE EQUIPMENT BUILDING 3396 W NELIS DR. MERIDIAN, ID 83646 RICK TRACY L150DetailsTOP SOILFINISH GRADE1/2" RADIUS4" x 6" EXTRUDEDCONCRETE MOW STRIPCOMPACTEDSUB-GRADEMULCHSOIL PLANTING MIX. SEESPECIFICATIONS FORADDITIONAL INFORMATION1Concrete EdgingScale: NTSNOTES:1.THE STAKING OF TREES IS TO BE THE CONTRACTOR'S OPTION; HOWEVER, THE CONTRACTOR ISRESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAINSTRAIGHT FOR A MINIMUM OF 1 YEAR. ALL STAKING SHALL BE REMOVED AT THE END OF THE ONEYEAR WARRANTY PERIOD.2.IN THE EVENT OF A QUESTION OR LACK OF CLARITY ON THE DRAWINGS, THE CONTRACTOR IS TONOTIFY THE LANDSCAPE ARCHITECT BEFORE PROCEEDING.3.LANDSCAPE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT AND OWNER PRIOR TOINSTALLATION OF PLANT MATERIAL.4.WRAP RUBBER CINCH TIES AROUND THE TREE TRUNKS AND STAKES USING EITHER THESTANDARD OR FIGURE EIGHT TYING METHOD. SECURE THE TIES TO THE STAKES WITHGALVANIZED NAILS TO PREVENT SLIPPAGE.5.WATER TREE TWICE WITHIN THE FIRST 24 HOURS.6.IN THE EVENT HARDPAN SOILS PREVENT TREE PLANTING AS DETAILED, NOTIFY THE LANDSCAPEARCHITECT IMMEDIATELY.PREVAILING WIND DIRECTIONREMOVE DEAD/DAMAGED BRANCHES AND PRUNE TOINTERNATIONAL SOCIETY OF ARBORICULTURE STANDARDS;IMPROPERLY PRUNED TREES (AS DETERMINED BY THELANDSCAPE ARCHITECT) SHALL BE REMOVED AND REPLACED.SET ROOTBALL ON NATIVE UNDISTURBED SUBSOILCOMMERCIAL SLOW RELEASE FERTILIZER TABLETSBACKFILL WITH SOIL PLANTING MIX. SEESPECIFICATIONS FOR ADDITIONAL INFORMATION.MULCH LAYER, KEEP MULCH 3" AWAY FROMTRUNK2" x 2" x 8' CEDAR STAKE - DO NOT PENETRATE ROOTBALL.SEE NOTE 1. SET STAKES PARALLEL TO PREVAILING WIND.RUBBER CINCH TIEFINISH GRADEROOT PROBESOIL LINEUTILIZE SOIL/ROOT PROBE AROUND TRUNK(APPROX. 3-4" AWAY FROM TRUNK) TO LOCATEHIGHEST ROOTS. HIGHEST ROOTS SHOULD BEPOSITIONED AT OR SLIGHTLY ABOVE GRADE LEVEL.REMOVE BURLAP, TWINE, AND WIRE BASKET FROM TOP12 OF ROOTBALL, REMOVE ALL NAILS, TIES, AND PLASTICFROM ROOTBALL. IF SYNTHETIC BURLAP IS UTILIZED TOWRAP THE ROOTBALL, IT SHALL BE COMPLETELYREMOVED. ONLY BIODEGRADEABLE BURLAP SHALL BELEFT ON THE BOTTOM OF THE ROOTBALL.2x ROOTBALL DIAMETER3x ROOTBALL DIAMETER6"TREE WRAP TRUNK PROTECTION,REMOVE AFTER INSTALLATION3"2Deciduous Tree PlantingScale: NTS4" MIN.DEPTH BACKFILL WITH SOIL PLANTINGMIX. SEE SPECIFICATIONS FORADDITIONAL INFORMATION.WATER RETENTIONBASINMULCH LAYERCOMMERCIALFERTILIZER TABLETS3Shrub PlantingScale: NTSNOTES:1.THE STAKING OF TREES IS TO BE THE CONTRACTOR'S OPTION; HOWEVER, THE CONTRACTOR ISRESPONSIBLE TO INSURE THAT ALL TREES ARE PLANTED STRAIGHT AND THAT THEY REMAINSTRAIGHT FOR A MINIMUM OF 1 YEAR. ALL STAKING SHALL BE REMOVED AT THE END OF THE ONEYEAR WARRANTY PERIOD.2.IN THE EVENT OF A QUESTION OR LACK OF CLARITY ON THE DRAWINGS, THE CONTRACTOR IS TONOTIFY THE LANDSCAPE ARCHITECT BEFORE PROCEEDING.3.LANDSCAPE CONTRACTOR IS TO NOTIFY THE LANDSCAPE ARCHITECT AND OWNER PRIOR TOINSTALLATION OF PLANT MATERIAL.4.WRAP RUBBER CINCH TIES AROUND THE TREE TRUNKS AND STAKES USING EITHER THE STANDARD ORFIGURE EIGHT TYING METHOD. SECURE THE TIES TO THE STAKES WITH GALVANIZED NAILS TOPREVENT SLIPPAGE.5.WATER TREE TWICE WITHIN THE FIRST 24 HOURS.6.IN THE EVENT HARDPAN SOILS PREVENT TREE PLANTING AS DETAILED, NOTIFY THE LANDSCAPEARCHITECT IMMEDIATELY.PREVAILING WIND DIRECTIONREMOVE DEAD/DAMAGED BRANCHES AND PRUNE TOINTERNATIONAL SOCIETY OF ARBORICULTURE STANDARDS;IMPROPERLY PRUNED TREES (AS DETERMINED BY THELANDSCAPE ARCHITECT) SHALL BE REMOVED AND REPLACED.SET ROOTBALL ON NATIVE UNDISTURBED SUBSOILCOMMERCIAL SLOW RELEASE FERTILIZER TABLETSBACKFILL WITH SOIL PLANTING MIX. SEESPECIFICATIONS FOR ADDITIONAL INFORMATION.MULCH LAYER, KEEP MULCH 3" AWAY FROMTRUNK2" x 2" x 8' CEDAR STAKE - DO NOT PENETRATE ROOTBALL.SEE NOTE 1. SET STAKES PARALLEL TO PREVAILING WIND.RUBBER CINCH TIEFINISH GRADEROOT PROBESOIL LINEUTILIZE SOIL/ROOT PROBE AROUND TRUNK(APPROX. 3-4" AWAY FROM TRUNK) TO LOCATEHIGHEST ROOTS. HIGHEST ROOTS SHOULD BEPOSITIONED AT OR SLIGHTLY ABOVE GRADE LEVEL.REMOVE BURLAP, TWINE, AND WIRE BASKET FROM TOP12 OF ROOTBALL, REMOVE ALL NAILS, TIES, AND PLASTICFROM ROOTBALL. IF SYNTHETIC BURLAP IS UTILIZED TOWRAP THE ROOTBALL, IT SHALL BE COMPLETELYREMOVED. ONLY BIODEGRADEABLE BURLAP SHALL BELEFT ON THE BOTTOM OF THE ROOTBALL.2x ROOTBALL DIAMETER3x ROOTBALL DIAMETER3"4Coniferous Tree PlantingScale: NTSNOTES:1. NOTIFY LANDSCAPE ARCHITECT WHEN PLACING BOULDERS FOR APPROVAL.2. PLACE BOULDERS PRIOR TO INSTALLATION OF IRRIGATION SYSTEM.3. CLEAN ALL BOULDERS OF DIRT AND LOOSE DEBRIS.4. WHEN PLACING BOULDERS, BURY 1/4 TO 1/3 OF BOULDER BELOW FINISH GRADE.5. DO NOT SCAR OR DAMAGE BOULDERS.FINISH GRADECOMPACTED SUBGRADE ASREQUIREDBOULDER, LOCATED, SIZE AND TYPE PERPLANS.SHRUB5Boulder InstallationScale: NTSSANDSTONE BOULDERSPER PLAN AND DETAIL5/L150.WASHED RIVER COBBLE.PLACE ROCKS IN ORGANICFASHION TO CREATE ASMALL CREEK LIKEAPPEARANCE.DECORATIVE ROCKMULCH PER PLANS.NOTES:1.CONTRACTOR SHALL PLACE ROCKS AROUND AND OVER TOP OF DRAINAGE GRATES TOCREATE CLEAN AND UNIFORM APPEARANCE WHERE APPLICABLE.2.REFERENCE GRADING PLAN FOR EXACT GRADES.Scale: NTSDry Stream Bed601.10.2020