D 191212 VillaSport CZC UtilityPlan 117108UGPUGPUGP OHPOHPOHPOHPOHPOHP
OHPOHPOHPOHPOHPOHP
UGP
WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WW
W
W
WW
WWWWW
WW
W
WWWWWWWWWWWWWWWWWWWWWWWWWWWWW
SSSSSS
SS
SS
SS
SS
SSSS
S
S
SSSSSSSS
SSSS
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
SSSSSSSSSSSSSSBOLBOL
X
X
X
UGPUGP UGPUGP
EP
UGP
UGP
UGP
UGP
UGP
UGP
UGP
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X X XXXXXXXXXXXX
X
X
X
X
S
S
MB
BASIS OF BEARINGMBSSS
CO
S
S SSS
S
S
S
S
S
S
S
S
S
EPEP EPEPOHP
WV
WV
CO
W
WV WVWV
WV
WVWV
WMTR
WV
WV
W
WV
WV
WV
WV
WV
WV
WVWVWV
WMTR
W
WV
WVWVWV
WV
WV
WMTR
WV
GIRR
VLT
VLTVLT
VLT
S
CO WS GIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRRGIRR
S
SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SDSDSDSDSDSDSDSD
FOF
E
OSOS
WV
WV
IVIV
IVIVIVWV
CBGRATE:2623.62'SUMP:2617.55'NO VISIBLE PIPES
CBGRATE:2621.87'IE(N)12"PVC:2618.86'SUMP:2618.37'
CBGRATE:2621.92'IE(S)12"PVC:2618.90'SUMP:2618.52'
CBGRATE:2624.42'IE(N)??"???:2620.77'SUMP:2619.98'
CBGRATE:2624.78'IE(S)12"PVC:2620.79'SUMP:2620.15'
CBGRATE:2624.03'IE(S)12"PVC:2620.09'SUMP:2619.56'WW
GIRRSDMHRIM:2623.77'IE(N)8"PVC:2620.34'SUMP:2617.64'
SDMHRIM:2622.52'IE(N)12"PVC:2617.82'IE(E)12"PVC:2617.89'IE(S)12"PVC:2617.82'
SDMHIE(N)12"PVC:2619.97'IE(E)12"PVC:2619.90'IE(S)12"PVC:2619.97'SUMP:2617.93'
SDMHRIM:2625.36'IE(N)12"PVC:2620.60'IE(S)12"PVC:2620.60'IE(W)12"PVC:2620.47'
CBGRATE:2623.88'IE(N)??"???:2620.20SUMP:2619.68'
IV
IVIV
IV
IRR
IVIV
IVIV
IV
IRR
IRR
IRR
IRR IRRIRR
IRR
IRR
IRRWWWWWWWEPEPEPEPW
W
W
W
W
W
W
W W W W W W
W W W WSSSSSS SS
CO
SS
SS
SAN
SAN
WCO
R/W
R/W
SDSD SDSD
SDSD
SDSD
SAN
MW
MW
MW
MW
MW
MW
MW
MW
SD
R/WR/WR/WR/WR/W R/W R/W R/WR/W
R/W R/W R/W R/W R/W
R/WR/WR/WR/WR/W R/W R/W
4
4
4
4
4
59
8
7
8
8
7
6
8
4
10
10
11
11
11
11
12
2595
2600
2605
2610
2615
2620
2625
2630
2635
2640
2645
2595
2600
2605
2610
2615
2620
2625
2630
2635
2640
2645
0+00.00 0+38.10 0+67.30
EXIST. SSMH 10029
RIM: 2622.24±
IE IN: 2609.76, 8-IN PVC (N)
IE OUT: 2609.78, 8-IN PVC (S)
IE OUT: 2609.64, 8-IN PVC (W)
Horizontal Scale:
0 60'120'
1" = 60'
Utility Plan-Overall
File Location:g:\2017\117108\cad\czc\117108 czc c5.00 utility plan.dwgLast Plotted By:james leoDate Plotted:Thursday, December 12 2019 at 03:40 PMOverall
Utility Plan
C5.00
Revisions
1.
Date of Issuance:
Project No.:
Project Milestone:
----
1
CONSTRUCTION
NOT FOR
C.Z.C.
12/12/2019VILLASPORTSWC USTICK RD & EAGLE RDMeridian, Idaho117108
Keynotes:
1.DOMESTIC WATER LINE
2.SEWER STUB, POINT OF CONNECTION FOR FUTURE BUILDING
3.EXISTING GRAVITY IRRIGATION STRUCTURE.
4.WATER MAIN PER ISPWC AND CITY OF MERIDIAN PUBLIC
WORKS REQUIREMENTS.
5.FIRE SERVICE PER ISPWV AND CITY OF MERIDIAN PUBLIC
WORKS REQUIREMENTS.
6.SEWER MAIN PER ISPWC AND CITY OF MERIDIAN PUBLIC
WORKS REQUIREMENTS.
7.SEWER MANHOLE PER ISPWC AND CITY OF MERIDIAN PUBLIC
WORKS REQUIREMENTS.
8.SEWER SERVICE PER ISPWC AND CITY OF MERIDIAN PUBLIC
WORKS REQUIREMENTS.
9.WATER SERVICE PER ISPWC AND CITY OF MERIDIAN PUBLIC
WORKS REQUIREMENTS.
10.PIPE CASING AT GRAVITY IRRIGATION CROSSING PER ISPWC
AND CITY OF MERIDIAN PUBLIC WORKS REQUIREMENTS.
11.CONNECT TO EXISTING UTILITY.
12.EXISTING SANITARY SEWER MANHOLE 10029.
#
W
GRAVITY IRRIGATION PIPE
WATER MAIN
SANITARY SEWER LATERAL
EXISTING GRAVITY IRRIGATION BOX
SEWER MANHOLE
FIRE HYDRANT
WATER VALVE
DRAINAGE SEEPAGE BED
SAN
Legend:
GIRR
1.THE PROPOSED IMPROVEMENTS AS SHOWN ARE PRELIMINARY IN NATURE
AND INTENDED TO SHOW THE METHOD BY WHICH NECESSARY UTILITY
SYSTEMS CAN BE CONSTRUCTED TO SERVE THE PROPOSED DEVELOPMENT
AND ARE SUBJECT TO CHANGE. PRIOR TO CONSTRUCTION, DETAILED
ENGINEERING PLANS WILL BE PREPARED FOR REVIEW AND APPROVAL BY
AGENCIES HAVING JURISDICTION.
Sheet Notes:
SSSS
EAGLE ROADUSTICK ROAD
FUTURE
VILLASPORT -
NOT A PART
NOT A PART
FUTURE
DEVELOPMENT
PAD - NOT A
PART
7
11
6
12
0
Horizontal Scale:
4020
1" = 20'
Sanitary Sewer Main - Profile