A202 Exterior ElevationsFinish Floor
0"
2 1 0
5
A301
Top of Sort Tilt Wall
21'-0 1/2"
Top of VMX Tilt Wall
25'-4 1/2"
2.1 1.5 102102102107234926492694926 107
Finish Floor
0"
21
5
A301
Top of Sort Tilt Wall
21'-0 1/2"
Top of VMX Tilt Wall
25'-4 1/2"
2.11.5
23 9107231212 49104
Finish Floor
0"
F
Sort Clear
14'-6"
GG.1
3
A301
E
Top of Sort Tilt Wall
21'-0 1/2"
Top of VMX Tilt Wall
25'-4 1/2"
102 9239104
DATE:
JOB No.:
DRAWN:
CHECKED:
SHEET NUMBER
NV
LLC
NEW EXPRESS SERVICE CENTER:EXPIRES: 12.31.2019
Larry L. Christian, A.I.A., N.C.A.R.B.
Idaho License Registration
#AR-984890
3801 KIRBY DR.SUITE 600
HOUSTON, TX 77098
TEL. (713) 664-7974
485 GRANDVIEW DR.
TWIN FALLS, IDAHO 83301
TEL: (208) 280-3000
OVER & UNDER INC.FEDEX EXPRESS BOIA90 VAN STATIONA202
Exterior Elevations
1906-257
2770 WEST FRANKLIN ROADMERIDIAN, ID09/30/19
1/8" = 1'-0"1 Partial West Elevation A - VMx
1/8" = 1'-0"2 Partial West Elevation B - VMx
1/8" = 1'-0"3 Partial South Elevation - VMx
Keynote Legend
9 PREFABRICATED OSHA COMPLIANT LADDER TO ROOF, RE: 01/A501
12 8" DIA. CONCRETE FILLED 1/4" THICK STEEL BOLLARDS EXTENDING 4' ABOVE TOP
OF SLAB AND A MIN. OF 3' BELOW TOP OF SLAB, PAINTED SAFETY YELLOW,
TYPICAL AT ALL OVERHEAD DOOR (EXTERIOR)
23 CONCRETE WALL PANEL, TYP. RE: STRUCT.
26 OVERHEAD DOOR AS SCHEDULED, TYP.
49 LIGHT FIXTURE, RE: ELEC.
102 SKYLIGHTS - 4'x8' SUNOPTICS MODEL 800MD SKYLIGHTS PRISMATIC POLYCARB.
LENS OR EQUAL. FM GLOBAL APPROVED. PROVIDE OSHA REQUIRED FALL
PROTECTION. INCLUDED CURB FLASHING AND STRUCTURAL SUPPORT. REFER TO
FXE SPECS
104 PREFINISHED METAL RAKE TRIM, TYP. RE: PEMB
107 GUTTER AND DOWNSPOUTS TO BE CONNECTED TO BELOW GRADE STORM DRAIN
SYSTEM. COORDINATE LOCATION W/ FXF PROJECT MANAGER.
REVISIONS
50% REVIEW SET 09/04/19
90% REVIEW SET 09/18/19