Loading...
PZ - Site Plan 1-8-2019 1 2 3 4 5 P. o SITE INFORMATION p/ N - - - - - - - - - - - - - - - - - - - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - - - - - - _ (� E / - - - _ __ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - I '' I , \ 10" w —�10" w-+--10" w7�—;,•Q — c = = �' _ - - � —' Iw-- - - - " �\`=- __= \\ - LOTAREA. 3 44SF ( 88A ) W —10" w10•• w— I /—10 w— 10" w --10' w-- IIII IIII � � �\ .`. —10" w10" w— -10" w— 1°•• w 10" w 84 0 C O N � � —10' w10" w---10" � 10" w —10" w— L � � co Sa /try i N �? z °_ Nf 4 L irr — irr—--lr � � PROPOSED BUILDING �' I \ � �— —Irr —irr —irr---Irr---irr— —irr— ire— irr irr-- irr— CONNECT TO EXISTING -\-- � - CID LOD LOD LOD LOD\ —irr———irr———irr irr—— irr ——irr—- c I N �i, •c c PRESSURE IRRIGATION _ TOTAL BUILDING FOOTPRINT: 7,564+/- SF z a) N I \ - - - - - - - - - - - - - - - - - _== = - - " %'-- — TOTAL BUILDING AREA (ALL FLOORS): 7,564+/- fflNAll "" sd---sd---sd— sd ,= \� • MAXIMUM BUILDING HEIGHT: 65'-0" O z L0 m / M a - - - - - - / i i/ \ �/ \� 'irr)I\� ///: 0 30' 60' \ ---- — _ 3 r rt �m iz' sd —iz" s iz" sd • , O I /i it\\wiz" sa— Yr11iIS��°\--12" sa 12.. Sd— r/IIII\� •� •' I, �j N � �I — bel —-—//,� - - - OO � �/� W = — --- 2"PI III ZONING REQUIREMENTS p` ••�� �• I � 2°P, 1 SCALE:1"=30' r OOl 00 = I C�lll,\� r o 1 a N • ZONING: CITY C-G, ALL ADJACENT LOTS TOO J �; I I o o , \\\ w o III °° I �T— — r— - —� ° ( \" LEGEND . BUILDING SETBACKS: o N I a ��Ilyr , N z z W THIS AREA NOT INCLUDED IN THIS PROPOSED - FRONT = 0' Z U) = O u III\\ I NOT INCLUDED IN 3 SITE CZC BUT IS SHOWN BECAUSE ACCESS - REAR = 0' — O u I o 0 AND UTILITY SERVICES TO THE PROPOSED 7 0 "I O III I - SIDES = O Z � wz III I THIS PHASE I SITE ARE INCLUDED IN THIS AREA (INCLUDING STORM TREATMENT.) A LANDSCAPE SETBACKS: m ss T-- m I III I • SEPARATE APPLICATION WILL BE MADE TO - LOCAL = 10' Q ¢ z LU /� o THE CITY FOR THE AREA. - COLLECTOR = 20 N �I�I\ o — ° ❑ — I 411IiP\\ \ f . I ; u_ Q 12'{I q——— 12'I w—— III \ I PROPOSED CONCRETE - ARTERIAL = 25 12 II Z 3 III I I I I I I i' •%• I SIDEWALK, TYP. ,. CONCRETE - ENTRYWAY CORRIDOR = 35' o W N I11 I I I PROPERTY - INTERSTATE = 50' c \\%�j •i •a �r�r— LINE F LANDSCAPE DRAIN ��o• _� w INLET TYP. v, 111 Ii III , ° ro LOD LIMIT OF DISTURBANCE (LOD) PARKING INFORMATION U 3 I I z \�II \ 90, • PARKING STALLS REQUIRED: 30 0 1 y Nyll 18' T 2= g' — — — — — 21.6' — i— 21' I ENGINEER • PARKING STALLS PROVIDED: 32 o W u ✓��i \ W (n , , • *HANDICAP STALLS REQUIRED: 2 � W STORM DRAIN HORROCKS ENGINEERS a 1 ss 1 \ INLET TYP. Rs • • **HANDICAP STALLS PROVIDED: 2 W 2775 W. NAVIGATOR DR. w 9' BICYCLE PARKING STALLS REQUIRED: 1 > uj STORM WATER Co M III SUITE 210 0 BICYCLE PARKING STALLS PROVIDED: 2 \ \ v INFILTRATION SYSTEM 1 � \ — � e- I I o III MERIDIAN, ID 83642 Z __ III 1 M CONTACT: ROB SUNDERLAGE PE NOTES: o PROPERTY 13.5 •7.5' 75' ' •• '.12.s'• I * 0 00 LINE o N PER ADA REQUIREMENTS o U) co I PHONE: 208-895-2520 INCLUDES 1 VAN ACCESSIBLE STALLS z Of co \ 9' v ** U e \ \ O y SD •SD — — ALL — -SD_— „ �� ,a \ I O -- — III REMOVE BLOWOFF\ I I III III I 10 3 DEVELOPER z o 1 �,, — z 2 DOMESTIC WATER m VALVE CONNECT TO z - - • 2 3 4 N EXISTING 8" WATER BVA DEVELOPMENT, LLC NOTES Q o 0 - °\� co` SERVICE AND METER I �� \ a \ Lp _ — _ o I I 2775 W. NAVIGATOR DR. � z z w U 1 ul "\\ \I 4 \`�\ 7' I 1 s F i Ii SUITE 220 1. DIMENSIONS ARE TO FRONT FACE OF CURB w Fn < w- HANDICAP SPACES, I I I I I I I EXISTING ACHD I- � Q O \ _ MERIDIAN ID 83642 Q w _ TYP. �, JURISDICTIONAL SEEPAGE BED FOR DRIVE ISLES. o 0 o U 0- 8" GATE VALVE PHONE: 208-616-1050 2. RADII ARE 3.5' UNLESS OTHERWISE NOTED. LIMIT OF 0 00 z DISTURBANCE, TYP. M 1 �, ADA RAMP, - a co I TYP. I I I Q U o\\ I \� 9 10.2' I Z O NN I I 25.3' I FLEXIBLE (ASPHALT) PAVEMENT ^� I 6" FIRE LINE I PROPOSED ! O \ \\ \\ _ \\P\ N I I I Sol N 5.3' o I I _ SECTION TABLE Z LLuu z z BUILDING 10.2 M P _ ..,\ \\ N \�o f` '" \o \ \\P SAND/OIL 17' LIGHT DUTY LD HEAVY DUTY HD U \� 0\ SEPARATOR o N e q \ / \ / \ • .. : \be, III I cq Eo I ASPHALTIC CONCRETE 2.511 3.011 O FIRE RISER ROOM STORM DRAIN APPROXIMATE f \� o CRUSHED AGGREGATE BASE 4.011 4.011 �. � \ fq9� INLET TYP. s FDC LOCATION •.III NN / / � �\\��\\ \� \ 23.3' � • E � ,I aQ o be \ \9°{bP'\ N STRUCTURAL SUBBASE 12.0" 18.0" \ I r rr M 1�9 7, „ \ „ SEE ARCHITECTURAL PLANS \ �,9 F ° o sr>\ // as' IIII SEE PAVEMENT SUBGRADE SEE PAVEMENT SUBGRADE FOR TRASH ENCLOSURE. be, �j \VGA V �aa s� S v SD �;. III ti \ \ / DUMPSTER PAD IN SCOPE OF y/r,, °j9 _=b_—__bel e, Sam II COMPACTED SUBGRADE PREPARATION SECTION PREPARATION SECTION °J9 —bel— PARKING CZC.` _ _— —— °;a — — ;4_� ASPHALT: ASPHALT MIX DESIGN SHALL MEET ISPWC SECTION 810 CLASS III PLANT MIX AND MATERIALS SHALL BE PLACED IN ACCORDANCE WITH ISPWC STANDARD 2,.w EX. FIRE _ _ _ W HYDRANT \\ SPECIFICATIONS FOR HIGHWAY CONSTRUCTION (1/2" MIX DESIGN) C / / - /<< \ ,2" w —,z" w—— AGGREGATE BASE: MATERIAL TO COMPLY WITH ISPWC STANDARD FOR CRUSHED12" Q \ �� � 12° W — • —,2' w— AGGREGATE BASE MATERIAL PROPERTY LINE CONNECT TO 8" SEWER SERVICE STRUTURAL SUBBASE: MATERIAL TO COMPLY WITH STRUCTURAL FILL SECTION OF > U si�———— 8"ss ——— 8"ss - - — 8"ss ——— — 8" — 8"ss - 8"ss — — 8"ss — 8"ss —- GEOTECH REPORT. THE PLACED MATERIAL SHALL BE NO GREATER THAN 4". N - - 0 o U CONCRETE PAD FOR BIKE - A QUALIFIED GEOTECHNICAL ENGINEER OR ENGINEERING TECHNICIAN IS REQUIRED TO z Z Q STALLS SEE LANDSCAPE - VERIFY SUBGRADE COMPETENCY AT THE TIME OF CONSTRUCTION. Q Q ARCHITECT PLANSLu - EX. SEWER \r \ -====- =- = = = ========-- /;� � � � ~ MANHOLE " ALL EARTHWORK, FLEXIBLE AND RIDID PAVEMENT CONSTRUCTION SHALL BE IN wCIO TYP. —'rr \ : _ _ _ _ ACCORDANCE WITH THE SITE GEOTECHNICAL REPORT. W G — Lu —irr— "•��\ ,�I;i•.= - - - - • irr irr— irr— \-�— —irr— —irr 1500 GAL. 90" CONST. GROUND WATER Q OBSERVATION WELL WITH PROVIDE GRADE RINGS METAL CAP AND LOCK AS NECESSARY 12" PRE—MANUFACTURED PERFORATED ADS N-12 PER ACHD SUPPLEMENTAL (12" MAX.). SET FLUSH PVC ASTM D 3034 PIPE OR APPROVED EQUAL. DRAWING NO. ACHD SD-627. WITH FINISH GRADE. PERFORATIONS ON TOP (1/2 OF PIPE ONLY) W (FG) \ \ \ \ \ \ \ \\\\ \7/\\7/\/\//\K J 3 RIM=A \/ /\\//\\\\\ \\/\\/\\/\\/\\/\\/\\/\\//\\//\\\/\\//\\//\\//\\//\\//\\//\\//\\//\\\\ \ - 5'-2-" z / / / // 8 0, g AVAjAj� z \jAjAjAjAjAjAjAjAjAjAj��VAjAAjAAjAAjAAjAAjAAjAAjAAj AAjAjAAjAAjAAjAAj 2$°O.D.TUBING 12 SOLID EXTENDED C5 ASNMO DDRAIN 4 PIPE ROCK / / / / / / / / /\!/\!/ /�\!/�\!/�\!/�\!/�\!/ ��\! \!/�\!/ .5"—2" WASHED IQ- / / / /�/�/�/�/�/�/�/�/� /�/�/�/�/�/�� /�/�i � II DRAIN ROCK • I _> � \j\j\j\j\j\j\j\j\j\j\j\j\j� � \j �„ o TOP OF SYSTEM (T) W $ TOP OF PIPE _ = INV. OUT = D 12 HE 0 0 0 0 0 0 0 0 0 0S1 OFF -0 0 0 00 0 0 SURFACEFLANGE MOUNT �N� \N' C° - (D) D GROUND LEVEL � ���� �� BOTTOM OF ROCK (B) � I mM a TS � IN-GROUND ANCHOR MOUNT III=III 1 .5' DEPTH co —ASTM C-33 SAND SEEPAGE BED SCHEDULE BOTTOM of (BS) IIIIII—III III III III=IIII — B I KE RACK DETAIL TOP BOTTOM BOTTOM GROUND VOLUME VOLUME 4 a 3 0 1 .5' MIN SEEPAGE FINISH GRADE LENGTH WIDTH DEPTH SAND INF RATE PROFILE VIEW IIIIIIIIIIIIIII=III=�MIN.I III III=IIII Ll SYSTEM ROCK WATER SOILS REQUIRED PROVIDED EXCAVATE MIN. 1 .5 INTO FREE BED (FG) (L) (W) (D) (18" MIN.) (IN HR) 3 3 — III — (T) (B) (BS) (SHGWE) (FT )(100YR) (FT ) DRAINING SANDS AND GRAVEL —' = —III III=� IIIIII—III III —III- 1 2576.00 2574.00 105.00 16.50 3.50 2570.50 2569 2567.5± 4.00 POORLY 2,406 2,426 SEE NOTE .) FOOTPLATE GRADED SEASONAL HIGH GROUNDWATER SHGWE GRAVEL W/SAN D NOTE: BID ALTERNATE #1 : LIMITS OF OF SAND LAYER (LENGTH/WIDTH) CAN MATCH LIMITS OF ROCK LAYER PAGE 1 OF 1 H:\!2019\ID-1866-1908 BVA TMX-Daycare\Project Data\02 CAD\2.03 Sheet Files\Concepts&Exhibits\ID-1866-1908_DAYCARE CZC.dwg -Layout1 - 1/08/2020 09:00am, hallie.runyan