Loading...
AO.1 Cover _ Layoutc Copyright 2019 J Truex Architect. The use of this document and these design/drawings herein are strictly controlled by US copyright law. This document and design may not be copied, emulated, or referenced without prior written approval by J Truex Architect. All violations will be prosecuted to the fullest extent of the law at the minimum of $100,000 per incident. Stamp 8403 Spring Creek Way Middleton, Id. 83644 Phone: 208-392-1219 208-634-9810 jtruexarchitecture.com J Truex Architecture Drawn by: _________________________________ Approved by: _________________________________ Date: _________________________________ Scale: _________________________________ Revisions Sheet number JT JT 6275 N. Linder Road Suite 100 Meridian, Id. Construction Drawings Homestead Bar & Grille Awning 11/20/19 SITE 6275 N. LINDER RD. MERIDIAN ID. 26 26 N. LINDER RD. S. LINDER RD. CHINDEN BLVD W. STATE ST. W. MCDERMOTT RD. N. BLACK CAT RD. N. TEN MILE RD. N. MERIDIAN RD. N. LOCUST GROVE RD. E. MCMILLAN RD. 40'-0" 10' EXISTING PARKING EXISTING PARKING 6275 N. LINDER RD. N. LINDER RD. 140 6233 N. LINDER RD. 100 110 120 130 EXISTING TENANT SPACE PROPOSED ADDITION TRASH ENCLOSURE TRASH ENCLOSURE BIKE RACK H H H H HANDICAP STALLS ACCESS TO LINDER SIDE WALK SIDE WALK VICINITY MAP NOT TO SCALE SITE PLAN 1" = 50' A1.0 HOMESTEAD BAR & GRILLE AB Anchor Bolts A/C Air Conditioner BLKG Blocking CAB Cabinet CAS Casement Window CJ Control Joint CEIL Ceiling CONC Concrete CONT Continuous COL Column D Dryer DBL R/S Double Rod & Shelf DIA Diameter DIAG Diagonal DISP Disposal DR Drawer DTL Detail DW Dish Washer EA Each ELE Elevation EQ Equal EXT Exterior EW Each Way FIX Fixed Window FD Floor Drain FF Finish Floor FND Foundation FOC Face of Concrete FOM Face of Masonry FOS Face of Stud FTG Footing GA Gauge GALV Galvanized GYP Gypsum HD Hold Down Anchor HDR Header HORIZ Horizontal HT Height HVAC Heating, Venting & Air Conditioning INSUL Insulation INT Interior LAND Landing LAV Lavatory LF Lineal Foot/Feet MAS Masonry MAX Maximum MFGR Manufacturer MIN Minimum MTL Metal NIC Not In Contract NTS Not To Scale OC On Center PL Plate PR Pair PSF Per Square Foot PT Pressure Treated R Riser RAD Radius REINF Reinforcing RS Rough Sawn REQ Required RO Rough Opening SECT Section SF Square Foot SH Single Hung Window SS Stainless Steel STD Standard SW Shear Wall T Tread T&B Top & Bottom TEMP Tempered glass T&G Tongue & Groove TOC Top of Concrete TOM Top of Masonry TOF Top of Footing TOP Top of Pier TOS Top of Slab TOW Top of Wall TV Television UNO Unless Noted Otherwise VERT Vertical VIF Verify In Field W Washer WH Water Heater ABBREVIATIONS 1. ALL CONSTRUCTION SHALL COMPLY WITH APPLICABLE CITY, COUNTY, STATE, AND FEDERAL REGULATIONS, AS WELL AS THE INTERNATIONAL BUILDING CODE, 2015 EDITION. 2. DO NOT SCALE DRAWINGS. SHOULD ANY DIMENSIONAL DISCREPANCIES BE NOTICED, CLARIFICATIONS CAN BE OBTAINED FROM THE ARCHITECT. ALL DIMENSIONS MUST BE VERIFIED IN FIELD PRIOR TO CONSTRUCTION. 3. THE CLIENT, ARCHITECT, CONSULTANTS AND ALL INSPECTORS FROM PERTINENT AGENCIES SHALL BE PERMITTED ACCESS TO THE JOB SITE AT ALL TIMES DURING NORMAL WORKING HOURS. 4. THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILTY FOR THE JOBE SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION INCLUDING SAFETY OF ALL PERSONS AND PRPOERTY. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE CONTRACTOR SHALL PROVIDE PUBLIC PROTECTION AS NECESSARY AND REQUIRED BY GOVERNING CITY AGENCIES. 5. THE GENERAL CONTRACTOR IS RESPONSIBLE TO COORDINATE WORK OF ALL SUBCONTRACTORS AND SHALL PERFORM SUCH MISCELLANOUS WORK AS MAY BE NECESSARY FOR THEM TO COMPLETE THEIR WORK. THE CONTRACTOR SHALL VERIFY THE SIZE AND LOCATION OF ALL FLOOR, WALL, AND ROOF OPENINGS WITH APPLICABLE DRAWINGS AND SHALL VERIFY THE LOCATIONS OF EMBEDDED ITEMS PRIOR TO POURING CONCRETE AND SHALL VERIFY THE LOCATION OF ALL UTILITIES SERVING THE BUILDING. 6. THE CONTRACTOR SHALL OBTAIN ALL PERMITS. PAY ALL FEES FOR PERMITS AND CHECK ALL GOVERNING AUTHORITIES SPECIFICATIONS FOR CONSTRUCTION , INCLUDING REMOVAL OR RELOCATION OF EXISTING UTILITIES OR OTHER PHYSICAL OBJECTS SHOWN ON PLANS OR OTHERWISE NOTED. 7. ALL COSTS FOR INSPECTIONS OR TESTS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, UNLESS NOTED OTHERWISE. 8. UNLESS NOTED ON THESE DRAWINGS AS BEING N.I.C. OR EXISTING, ALL ITEMS, MATERIALS, ETC. AND THE INSTALLATION OF SAME ARE A PART OF THE CONTRACT DEFINED BY THESE DOCUMENTS. 9. PROVIDE METAL CORNER BEAD AT ALL OUTSIDE CORNERS OF PLASTER OR DRYWALL, AND METAL TRIM OR CASING BEAD AT ALL EDGES OF PLASTER OR DRYWALL WHERE THEY TERMINATE AGAINST ANY OTHER MATERIAL, U.N.O. ALL EXTERIOR OR INTERIOR EXPOSED FLASHINGS TRIM, ETC. SHALL BE PAINTED TO MATCH ADJACENT MATERIALS, U.N.O. THE CONTRACTOR SHALL PROVIDE BACKING AS REQUIRED FOR ATTACHEMENT OF ALL EXTERIOR OR INTERIOR FINISHES, FITURES, ETC. 10. KEEP ALL DUCTWORK, CONDUITS, PIPING, ETC. AS CLOSE TO WALLS AND UNDERSIDE OF ROOF AS POSSIBLE. 11. EXIT DOORS SHALL BE OPERABLE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. OR, IN GROUP A-3, B, F, M OR S OCCUPANCIES, KEY-LOCKING HARDWARE MAY BE USED ON THE MAIN EXIT DOOR(S) IF THERE IS A READILY VISIBLE, DURABLE SIGN ATTACHED ON OR ADJACENT TO EACH DOOR STATING: "THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS". THE SIGN SHALL BE IN 1" HIGH LETTERS ON A CONTRASTING BACKGROUND. WHEN UNLOCKED, THE DOOR(S) MUST BE FREE TO SWING WITHOUT THE OPERATION OF A LATCHING DEVICE (I.E, PUSH-PULL). 12. ALL DOOR HARDWARE SHALL BE MOUNTED FROM 30" TO 44" ABOVE THE FLOOR AND SHALL BE OPERABLE BY A SINGLE EFFORT WITH NO GRASPING OR WRIST MOVEMENT (I.E., LEVERS PUSH-PULLS, OR PANIC HARDWARE). THE ALLOWABLE CLOSER PRESSURE SHALL NOT EXCEED 5 POUNDS FOR INTERIOR DOORS, 8.5 POUNDS FOR EXTERIOR DOORS, AND 15 POUNDS FOR FIRE DOORS OR DOORS WITH PANIC HARDWARE. 13. EXTERIOR DOORS SHALL RECEIVE DEAD BOLTS AND DEAD LOCKING LATCHES. STRAIGHT DEAD BOLTS SHALL HAVE A MINIMUM THROW OF 1" AND AN EMBEDMENT OF NOT LESS THAN 5/8". CYLINDER GUARDS SHALL BE INSTALLED ON ALL CYLINDER LOCKS WHEN THE CYLINDER PROJECTS FROM THE FACE OF THE DOOR OR IS OTHERWISE ACCESSIBLE TO GRIPPING TOOLS. DOOR HINGES ACCESSIBLE FROM THE OUTSIDE SHALL HAVE NON-REMOVABLE PINS. 14. SET DOOR JAMBS 2" FROM THE NEAREST FACE OF THE WALL, U.N.O. THREASHOLDS SHALL HAVE A MAXIMUM HEIGHT OF 1/2" WITH A MAXIMUM VERTICAL CHANGE OF 1/4". 15. SEPARET APPROVAL FOR TEMPORARY OR PERMANENT SIGNAGE IS REQUIRED FROM THE CITY. 16. FIRE EXTINGUISHERS SHALL BE INSTALLED PRIOR TO BUILDING OCCUPANCY AND RATED 2A 10BC. LOCATIONS SHALL BE DETERMINED BY THE FIRE INSPECTOR IN THE FIELD. PROVIDE EXTINGUISHERS EVERY 3,000 S.F. AND 75' CF UNOBSTRUCTED WALKING DISTANCE. 17. ALL INTERIOR WALL AND CEILING FINISHES SHALL HAVE A CLASS III RATING MINIMUM (FLAME SPREAD 200, SMOKE DEVELOPED 450). FLOOR FINISHES SHALL HAVE A SLIP-RESISTANT FINISH. 18. ALL INSULATAION MATERIALS, INCLUDING FACINGS, INSTALLED WITHIN CEILING ASSEMBLIES, WALLS, CRAWL SPACES, OR ATTICS SHALL HAVE A FLAME SPREAD NOT TO EXCEED 25 AND A SMOKE DENSITY NOT TO EXCEED 450. 19. ALL EXTERIOR OPENINGS, FLASHINGS, COPINGS, EXPANSION JOINTS, ETC., SHALL BE WEATHERPROOF. ALL EXTERIOR DOORS AND WINDOWS, DOOR AND WINDOWS BETWEEN CONDITION AND UNCONDITIONED SPACES, EXTERIOR JOINT PENETRATIONS, AND OTHER OPENINGS IN THE BUILDING ENVELOPE SHALL BE CAULKED , GASKETED, WEATHER-STRIPPED, OR OTHERWEISE SEALED TO LIMIT AIR LEAKAGE. PROVIDE A METAL ASTRAGAL AT THE ACTIVE LEAF OF EACH PAIR OF EXTERIOR DOORS. 20. PROVIDE ISOLATION OF ALL DISSIMILAR METALS (ALUMINUM, COPPER, STEEL ETC.) FROM EACHOTHER TO PREVENT GALVANIC CORROSION. 21. THE CONTRACTOR SHALL POST, ADJACENT TO THE BUILDING PERMIT, INSTALLATION CERTIFICATES FOR MANUFACTURED DEVICES REGULATED BY THE LOCAL ENERGY EFFICIENCY STANDARDS IF REQUIRED CERTIFICATES SHALL INDICATE FEATURES REQUIRED TO VERIFY COMPLIANCE, A STATEMENT THAT INSTALLED DEVICES CONFORM WITH THE STANDARDS, REQUIREMENTS FOR SUCH DEVICES IN THE APPROVED PLANS AND SPECIFICATIONS, AND THE PERMIT NUMBER. 22. THE CONTRACTOR SHALL PROVIDE THE OWNER WITH A LIST OF THE HEATING, COOLING, WATER HEATING, LIGHTING, AND CONSERVATION SYSTEMS, FEATURES, MATERIALS, COMPONENTS, AD DEVICES INSTALLED IN THE BUILDING AND INSTRUCTIONS ON HOW TO USE THEM; LABELS ON MANUFACTURED DEVICES CLEARLY STATING ROUTINE MAINTENANCE ACTION; AND A DESCRIPTION OF THE QUANTITIES OF OUTDOOR AND RECIRCULATED AIR THAT THE VENTILATION SYSTEM IS DESIGNED TO PROVIDE EACH AREA. 23. EGRESS PATHS SHALL BE ILLUMINATED WITH A MINIMUM EMERGENCY LIGHT INTENSITY OF 10 FOOT-CANDLES AT THE FLOOR LEVEL. PROVIDE EMERGENCY ILLUMINATION FIXTURES WITH 1-1/2 HOURS OF BATTERY BACK UP POWER, ACCORDING TO NFPA 101. 24. ALL HANDRAIL, GRAB BAR, WALL MOUNTED SINCKS ETC. REQUIRE FIRE RATED 2X12 BLOCKING (TYP.) Cover Sheet PROJECT DIRECTORY CLIENT ZACH KIEBEL 1675 W RATTLESNAKE CT MERIDIAN, ID. 83646 208-906-5542 BUILDING CITY OF MERIDIAN DEPARTMENT 33 E. BROADWAY AVE. STE. 102 MERIDIAN, ID. 83642 208-887-2211 GENERAL CONTRACTOR TBD ARCHITECT J. TRUEX ARCHITECTURE 8403 SPRING CREEK WAY MIDDLETON, ID. 83644 208-634-9810 CONTACT JEVON TRUEX SHEET INDEX ARCHITECTURAL: A1.0 COVER SHEET, CODE DATA A1.1 FLOOR PLAN, FURNISHING & AISLE ACCESSWAY PLAN A2.1 WINTER ELEVATIONS A2.2 WARM MONTH ELEVATIONS AWNING/ENCLOSURE DRAWINGS: TBD BUSINESS NAME: HOMESTEAD BAR & GRILLE 6275 N. LINDER ROAD - SUITE 100 MERIDIAN 83646 PROJECT: RESTRAUNT ADDITION APLICABLE CODES: BUILDING CODE 2015 INTERNATIONAL BUILDING CODE (IBC) MECHANICAL 2012 INTERNATIONAL MECHANICAL CODE PLUMBING 2015 IDAHO PLUMBING CODE ELECTRICAL 2017 NATIONAL ELECTRICAL CODE FIRE 2015 IDAHO FIRE CODE ACCESSIBILITY 2009 ICC/ANSI A117 CONSTRUCTION TYPE: TYPE V-B (EXISTING) ZONING: C-G FIRE PROTECTION SYSTEMS: BUILDING IS NOT SPRINKLED. OCCUPANCY CLASSIFICATION: OCCUPANCY = A-2 (RESTAURANTS) BUILDING AREA SUMMARY (APPROX. GROSS SQUARE FEET) LEASE SPACE 2,500 SF. EXISTING (ADDING 414 SF. OF DINING AREA) DINING/LOUNGE AREA = 1,749 SF. (INCLUDING ADDED 414 SF.) KITCHEN/PREP/COOKING = 887 SF. ACCESSORY SPACE = 278 SF. TOTAL = 2,914 SF. OCCUPANCY AREAS & INDIVIDUAL OCCUPANCIES DINING AREA = (MINUS AISLE ACCESSWAYS) 1,242 SF. = 83 OCCUPANTS (15 OLF) KITCHEN = 887 SF. = 5 OCCUPANTS (200 OLF) ACCESSORY SPACE = 278 SF. = 0 OCCUPANTS TOTAL OCCUPANT LOAD = 88 EXITING: TWO EXITS REQUIRED FROM EXISTING SPACE - THREE PROVIDED. ONE EXIT REQUIRED FROM ADDITION - ONE PROVIDED PLUMBING FIXTURE REQUIREMENTS: TWO WATER CLOSETS REQUIRED - TWO PROVIDED (EXISTING) TWO LAVATORIES REQUIRED - TWO PROVIDED (EXISTING) ONE URINAL PROVIDED IN ADDITION TO REQUIRED WATER CLOSET FOR MEN. DRINKING FOUNTAIN - WATER PROVIDED BY RESTAURANT. PARKING: EXISTING BUILDING AREA (14,212 SF.) + ADDITION (414 SF.) = 14,626 SF. 14,626/250 = 59 SPACES REQUIRED. PROVIDED = 86 STALLS INCLUDING (4) HANDICAP STALLS. BIKE SPACES REQUIRED 1:25 REQUIRED PARKING SPACES = 3 PROVIDED = 5 SPACES SITE: LOT AREA = 2.39 AC. SETBACKS = FRONT, REAR, & INTERIOR SIDE YARD = ZERO FEET. PROJECT INFORMATION