A1.1 Floor Plan _ Layoutc Copyright 2019 J Truex Architect. The use of
this document and these design/drawings herein
are strictly controlled by US copyright law. This
document and design may not be copied,
emulated, or referenced without prior written
approval by J Truex Architect. All violations will be
prosecuted to the fullest extent of the law at the
minimum of $100,000 per incident.
Stamp
8403 Spring Creek Way Middleton, Id. 83644
Phone: 208-392-1219 208-634-9810
jtruexarchitecture.com
J Truex Architecture
Drawn by:
_________________________________
Approved by:
_________________________________
Date:
_________________________________
Scale:
_________________________________
Revisions
Sheet number
JT
JT
6275 N. Linder Road Suite 100
Meridian, Id.
Construction Drawings
Homestead Bar & Grille Awning
11/20/19
40'-0" 10'-5"
10'-0"
10'-0"
EXISTING
KITCHEN
EXISTING
MENS
RESTROOM
EXISTING
WOMENS
RESTROOM
EXISTING
COOLER
EXISTING
BAR
EMPLOYEE ONLY
EMPLOYEE ONLY
EMPLOYEE ONLY
EMPLOYEE ONLY
WAITRESS
STATION
EMPLOYEE ONLY
EXISTING DINING/LOUNGE AREA
EXISTING
KITCHEN
NEW
DINING
AREA
EXISTING
EXIT
EXISTING
EXIT
EXISTING
EXIT
NEW EXIT
MAIN ENTRY
EXIT PATH
EXIT PATH
EXIT PATH
EXIT PATH
EXIT PATH EXIT PATH
EXIT PATH
MAX TRAVEL
DISTANCE = 60'
MAX TRAVEL
DISTANCE = 57'
MAX TRAVEL
DISTANCE = 40'
V.I.F.
NEW 3068 EXIT DOOR. VERIFY PANIC HARDWARE
INSTALLED AT EGRESS EXIT DOOR (TYP.)
LOCK: IF A KEY/LOCK IS TO BE USED, A READILY
VISIBLE DURABLE SIGN MUST BE POSTED ON THE
EGRESS SIDE ON OR ADJACENT TO THE DOOR
STATING: "THIS DOOR TO REMAIN UNLOCKED WHEN
THIS SPACE IS OCCUPIED". THE SIGN SHALL BE IN
LETTERS 1 INCH HIGH ON A CONTRASTING
BACKGROUND.
EXISTING WALL MOUNTED
EMERGENCY EXIT LIGHT (TYP.)
NEW WALL MOUNTED
EMERGENCY EXIT
LIGHT (TYP.)
ADDITION
ADDITION
EXISTING EXTERIOR
WALL
EXISTING INTERIOR/
SEPARATION WALL
EXISTING EXTERIOR
WALL
EXISTING EXTERIOR
WALL & STOREFRONT
EXISTING INTERIOR WALL
EXISTING INTERIOR WALL
NEW AWNING STRUCTURE
WITH SEASONAL VYNAL
COVERING. SPECIFIC
DESIGN, DETAILS ETC. BY
OTHERS.
NEW WALL (BY OTHERS)
EXISTING WALL/COLUMN
EXISTING UNUSED DOOR
NOT AN EXIT
EXISTING OVERHEAD DOOR
21 OCCUPANTS
EMPLOYEE ONLY
EXISTING
WALK-IN
VERIFY PANIC HARDWARE
INSTALLED AT EGRESS EXIT
DOOR (TYP.)
VERIFY PANIC HARDWARE
INSTALLED AT EGRESS EXIT
DOOR (TYP.)
VERIFY PANIC HARDWARE
INSTALLED AT EGRESS EXIT
DOOR (TYP.)
EXISTING PORTABLE
FIRE EXTINGUISHER
VERIFY 20' CLEAR SPACE
TO ADJACENT BUILDING
VERIFY 20' CLEAR SPACE
TO ADJACENT BUILDING
1'-7"
1'-7"
1'-7"
1'-7"
1'-7"
1'-7"
1'-7"
MIN.
(TYP.)
MIN.
(TYP.)
MIN.
(TYP.)
MIN.
(TYP.)
MIN.
(TYP.)
MIN.
(TYP.)
EXIT PATH/
AISLE ACCESSWAY
EXIT PATH/
AISLE ACCESSWAY
EXIT PATH/
AISLE ACCESSWAY
EXIT PATH/
AISLE ACCESSWAY
EXIT PATH/
AISLE ACCESSWAY
EXIT PATH/
AISLE ACCESSWAY
EXIT PATH/
AISLE ACCESSWAY
EXISTING
KITCHEN
EXISTING
MENS
RESTROOM
EXISTING
WOMENS
RESTROOM
EXISTING
COOLER
EXISTING
BAR
EXISTING DINING/
LOUNGE AREA
EXISTING
KITCHEN
NEW
DINING
AREA
FLOOR PLAN / EGRESS PLAN
1/4" = 1'-0"
FURNISHING / AISLE ACCESSWAY PLAN
1/4" = 1'-0"
A1.1
Floor Plan