Loading...
A1.1 Floor Plan _ Layoutc Copyright 2019 J Truex Architect. The use of this document and these design/drawings herein are strictly controlled by US copyright law. This document and design may not be copied, emulated, or referenced without prior written approval by J Truex Architect. All violations will be prosecuted to the fullest extent of the law at the minimum of $100,000 per incident. Stamp 8403 Spring Creek Way Middleton, Id. 83644 Phone: 208-392-1219 208-634-9810 jtruexarchitecture.com J Truex Architecture Drawn by: _________________________________ Approved by: _________________________________ Date: _________________________________ Scale: _________________________________ Revisions Sheet number JT JT 6275 N. Linder Road Suite 100 Meridian, Id. Construction Drawings Homestead Bar & Grille Awning 11/20/19 40'-0" 10'-5" 10'-0" 10'-0" EXISTING KITCHEN EXISTING MENS RESTROOM EXISTING WOMENS RESTROOM EXISTING COOLER EXISTING BAR EMPLOYEE ONLY EMPLOYEE ONLY EMPLOYEE ONLY EMPLOYEE ONLY WAITRESS STATION EMPLOYEE ONLY EXISTING DINING/LOUNGE AREA EXISTING KITCHEN NEW DINING AREA EXISTING EXIT EXISTING EXIT EXISTING EXIT NEW EXIT MAIN ENTRY EXIT PATH EXIT PATH EXIT PATH EXIT PATH EXIT PATH EXIT PATH EXIT PATH MAX TRAVEL DISTANCE = 60' MAX TRAVEL DISTANCE = 57' MAX TRAVEL DISTANCE = 40' V.I.F. NEW 3068 EXIT DOOR. VERIFY PANIC HARDWARE INSTALLED AT EGRESS EXIT DOOR (TYP.) LOCK: IF A KEY/LOCK IS TO BE USED, A READILY VISIBLE DURABLE SIGN MUST BE POSTED ON THE EGRESS SIDE ON OR ADJACENT TO THE DOOR STATING: "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED". THE SIGN SHALL BE IN LETTERS 1 INCH HIGH ON A CONTRASTING BACKGROUND. EXISTING WALL MOUNTED EMERGENCY EXIT LIGHT (TYP.) NEW WALL MOUNTED EMERGENCY EXIT LIGHT (TYP.) ADDITION ADDITION EXISTING EXTERIOR WALL EXISTING INTERIOR/ SEPARATION WALL EXISTING EXTERIOR WALL EXISTING EXTERIOR WALL & STOREFRONT EXISTING INTERIOR WALL EXISTING INTERIOR WALL NEW AWNING STRUCTURE WITH SEASONAL VYNAL COVERING. SPECIFIC DESIGN, DETAILS ETC. BY OTHERS. NEW WALL (BY OTHERS) EXISTING WALL/COLUMN EXISTING UNUSED DOOR NOT AN EXIT EXISTING OVERHEAD DOOR 21 OCCUPANTS EMPLOYEE ONLY EXISTING WALK-IN VERIFY PANIC HARDWARE INSTALLED AT EGRESS EXIT DOOR (TYP.) VERIFY PANIC HARDWARE INSTALLED AT EGRESS EXIT DOOR (TYP.) VERIFY PANIC HARDWARE INSTALLED AT EGRESS EXIT DOOR (TYP.) EXISTING PORTABLE FIRE EXTINGUISHER VERIFY 20' CLEAR SPACE TO ADJACENT BUILDING VERIFY 20' CLEAR SPACE TO ADJACENT BUILDING 1'-7" 1'-7" 1'-7" 1'-7" 1'-7" 1'-7" 1'-7" MIN. (TYP.) MIN. (TYP.) MIN. (TYP.) MIN. (TYP.) MIN. (TYP.) MIN. (TYP.) EXIT PATH/ AISLE ACCESSWAY EXIT PATH/ AISLE ACCESSWAY EXIT PATH/ AISLE ACCESSWAY EXIT PATH/ AISLE ACCESSWAY EXIT PATH/ AISLE ACCESSWAY EXIT PATH/ AISLE ACCESSWAY EXIT PATH/ AISLE ACCESSWAY EXISTING KITCHEN EXISTING MENS RESTROOM EXISTING WOMENS RESTROOM EXISTING COOLER EXISTING BAR EXISTING DINING/ LOUNGE AREA EXISTING KITCHEN NEW DINING AREA FLOOR PLAN / EGRESS PLAN 1/4" = 1'-0" FURNISHING / AISLE ACCESSWAY PLAN 1/4" = 1'-0" A1.1 Floor Plan