Loading...
PZ - Soils ReportConsulting, Soil Evaluations & Data Collection October 13, 2017 Jon Wardle Brighton Corporation 12601 W. Explorer Drive Suite 200 Boise, ID 83713 Mc HARLEYR. NOE Phone: 208.850.4926 Fax: 208.939-8602 RE: Final 2017 monitor report for Century Commercial property I have completed data collection for the irrigation season on the Century Commercial parcel located just south of Amity Road and north of Century Farm Development. A copy of collected measurements is attached along with a map showing all piezometer locations are attached. Ten test pits were placed in late September of 2016 by MTI. Late season measurements were collected in the piezometers on October 11th and 22nd to secure baseline values. A comparison of the October 11, 2016 data to the levels recorded on October 9th shows that current levels are 10 to 17 inches higher than last year. Peak levels are 13 to 27 inches higher than the September 25th values last fall. As observed in the data from the Century Farm project to the south, peaks occurred late in the season. This supports the assumption that levels on the commercial site are also due to offsite influences from the surrounding area. There is still a considerable amount of irrigated cropland to the north, east and west of this property. It is my opinion that the irrigation impacts are less important than the up -gradient natural infiltration into the shallow aquifer. The peaks observed are likely on the high end of the range expected from year to year. Abnormally high precipitation amounts last winter have likely had an influence on not only peak levels, but also the later timing of those levels. These high groundwater peaks should be conservative values if used for design purposes. 5740 N. APPLEBROOti WAY BOISE, IDAHO 83713 Century Commercial - page 2 There is a significant variation in the topography from east to west on the parcel. Most of the property to the east is at a higher elevation than the southwest portion. On those higher landscape positions the groundwater is deeper than 10 feet below ground level while in the lower positions levels are measured at 6 to 7 feet deep. When these measurements are converted to groundwater elevation, the level will likely be uniform across the parcel. If you have any questions, please call me at 850-4926 or by e-mail at harleynoe@cableone.net. transmitted via e-mail HARLEY R. NOE Professional Soil Scientist W J U W 0 U Century Commercial Site 2017 Groundwater Monitoring All readings are depth below ground level in inches Hole Number Bottom Depth 3117 4/23 5/9 5/24 615 6/20 7/3 7117 7131 8115 8128 9/11 9/25 10/9 TP1D-16 116 101 103 98 91 92 98 102 102 94 90 92 92 89 92 TP2E-16 186 186 186 186 186 186 186 186 186 186 186 186 186 186 186 TP31-16 1_ 148 148 dest dest dest dest dest dest dest dest dest dest dest dest TP4H-16 57 57 57 57 57 57 57 57 57 57 57 57 57 57 TP5G-16 1:1W 139 139 139 139 139 139 139 139 139 139 139 139 139 139 TP6F-16 Vi 141 123 129 129 129 129 129 131 123 125 118 139 141 141 TP7J-16 in 100 96 85 82 89 91 91 94 95 91 95 85 80 85 TP8B-16 12", 109 113 109 106 107 107 97 90 89 84 73 84 88 91 TP9A-16 121.1 115 dest dest dest dest dest dest dest dest dest dest dest dest dest TP10C-16 i o 95 97 83 79 89 88 86 86 84 78 81 72 67 75