0070 - A2 ELEVATIONS AND SIGNAGE - 3093XXXX
_______
A1.1
1
PICKUP AND SPARK SIGN TO BE RELOCATED
TO NEW EXPANSION REF 3-A1.1
PATCH AND REPAIR SURFACES TO MATCH
ADJACENT
EXISTING SIGNAGE AND PAINT TO
REMAIN UNLESS NOTED OTHERWISE
_______
A1.1
3
EXISTING GARDEN CENTER WALL AND FENCE NOT SHOWN FOR CLARITY
EXISTING SIGNAGE AND PAINT TO
REMAIN UNLESS NOTED OTHERWISE
NEW DOOR SLAB PAINTED TO MATCH ADJACENT WALL EXISTING DOOR SLAB AND
FRAME TO REMAIN, PAINT
TO MATCH ADJACENT WALL
EXISTING SIGNAGE AND PAINT TO
REMAIN UNLESS NOTED OTHERWISE
EXISTING SIGNAGE AND PAINT TO
REMAIN UNLESS NOTED OTHERWISE
SIGNAGE GENERAL NOTES
1. BUILDING SIGNAGE FURNISHED BY WALMART, INSTALLED BY
OTHERS. SITE DIRECTIONAL PLACARDS FURNISHED BY
WALMART, INSTALLED BY G.C.; POLE FURNISHED AND INSTALLED
BY G.C. PAVEMENT PAINT FURNISHED AND INSTALLED BY G.C.
2. GENERAL CONTRACTOR RESPONSIBILITIES:
A. BY END OF FIRST WEEK OF CONSTRUCTION, REVIEW
EXISTING CONSTRUCTION WHERE SIGN(S) WILL BE
INSTALLED. IF EXISTING CONDITIONS DO NOT MATCH SIGN
ATTACHMENT DETAILS SHOWN, REQUEST APPROVAL FROM
CONSTRUCTION MANAGER TO SUBMIT RFI IN ACCORDANCE
WITH SECTION 01255. NOTE DIFFERENCES IN CONSTRUCTION,
INCLUDING DIMENSIONS, AND INCLUDE PHOTOGRAPHS FOR
CLARIFICATION.
B. PROVIDE JUNCTION BOXES AND CIRCUITRY TO NEW "Pickup"
AND "spark" SIGNAGE.
C. VERIFY VOLTAGE AT CIRCUITS FEEDING LIGHTED SIGNAGE.
REFER TO ELECTRICAL.
D. MAKE FINAL TERMINATIONS ON LIGHTED SIGNAGE.
E. INSTALL CHECK-IN KIOSKS & COORDINATE W/ VENDOR.
F. FOR SPECIAL PROJECTS, WHEN REQUIRED BY AHJ, G.C. IS
RESPONSIBLE TO ACQUIRE SEPARATE PERMIT(S) FOR
INSTALLATION OF SITE SIGNS. FOR REM PROJECTS, FOLLOW
REM SIGN STANDARDS FOR PERMITS AND INSTALLATION.
G. ALL SIGN PLACARDS FURNISHED BY WALMART AND
INSTALLED BY GENERAL CONTRACTOR. ALL PAINT FOR
PAVEMENT MARKINGS ARE SUPPLIED AND PAINTED BY THE
GENERAL CONTRACTOR.
3. SIGNAGE CONTRACTOR RESPONSIBILITIES:
A. FURNISH SPECIFIED CONDUIT FOR LIGHTED SIGNAGE.
B. MAKE REQUIRED EXTERIOR WALL PENETRATIONS, INSTALL
CONDUIT, AND SEAL PENETRATIONS PER SPECIFICATION
SECTION 07900.
C. INSTALL SIGNAGE PER DETAILS ON THIS SHEET.
EXISTING SIGNAGE SCHEDULE
COLOR
WHITE
YELLOW
WHITE
QTY
WALMART 1
SIGNAGE LOCATION
FRONT SIGNAGE
*SPARK 1
Market 1
TOTAL AREA
INDIVIDUAL
AREA
SIZE
5'-6"
8'-0" 298.00 SF 298.00 SF
2'-6" 28.17 SF 28.17 SF
HomeWHITE & Pharmacy 1 2'-6" 97.66 SF 97.66 SF
OutdoorWHITE Living 1 2'-6" 77.17 SF 77.17 SF
TOTAL FRONT SIGNAGE 567.76 SF
TIRE1WHITE & LUBE
AUTO CENTER SIGNAGE
2'-0"
TOTAL AUTO CENTER SIGNAGE 160.57 SF
28.94 SF 28.94 SF
TOTAL FRONT SIGNAGE 728.33 SF
TireWHITE 1 1'-0" 2.38 SF 4.76 SF
LubeWHITE 2 1'-0" 3.13 SF 6.26 SF
LIGHTED
LED
LED
N/A
N/A
N/A
N/A
N/A
N/A
AGGREGATE SIGNAGE SCHEDULE
SIGNAGE LOCATION QTY COLOR TOTAL AREA
INDIVIDUAL
AREA
LIGHTED SIZE
WHITE
YELLOW
Pickup 1
*SPARK 1
5'-6"
8'-0" 66.76 SF 66.76 SF
LED
LED
WHITE
YELLOW
WALMART 1
*SPARK 1
3'-6"
5'-0" 120.61 SF 120.61 SF
LED
LED
WHITE
YELLOW
WHITE
WALMART ETR
FRONT SIGNAGE
*SPARK
Market
5'-6"
8'-0" 298.00 SF 298.00 SF
2'-6" 28.17 SF 28.17 SF
HomeWHITE & Pharmacy 2'-6" 97.66 SF 97.66 SF
TOTAL FRONT SIGNAGE 490.59 SF
TIREWHITE & LUBE
AUTO CENTER SIGNAGE
2'-0"
TOTAL AUTO CENTER SIGNAGE 160.57 SF
28.94 SF 28.94 SF
TOTAL FRONT SIGNAGE 651.16 SF
WHITE 1'-0" 2.38 SF 4.76 SF
LubeWHITE 1'-0" 3.13 SF 6.26 SF
LED
LED
N/A
N/A
N/A
N/A
N/A
WHITE
YELLOW
Pickup
*SPARK
5'-6"
8'-0" 66.76 SF 66.76 SF
LED
LED
WHITE
YELLOW
WALMART
*SPARK
3'-6"
5'-0" 120.61 SF 120.61 SF
LED
LED
Tire
ETR
ETR
ETR
ETR
ETR
ETR
ETR
ETR
ETR
ETR
65.43 SF
WHITE PLASTIC LETTERS
PLASTIC LETTERS MATCH
SW #6904 "GUSTO GOLD"
2'-6"
4'-5 7/16"
14'-8 5/16"
NOTE TO SIGN INSTALLER:
ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED. IF MOUNTING THROUGH
PRIMARY HOLE IS OBSTRUCTED BY REBAR, METAL STUDS, CHANNELS, OR
OTHER MISC METAL, SEAL PRIMARY HOLE IN SIGN CAN AND MOUNT THROUGH
THE NEAREST ALTERNATE MOUNTING HOLE. PRIMARY HOLES ARE INDICATED
WITH PREDRILLED HOLES THROUGH WASHERS. ALTERNATE HOLES ARE
INDICATED WITH WASHERS ONLY OR ARE OTHERWISE MARKED.
NOTE:
ALL SIGN PENETRATIONS ABOVE
ROOF LEVEL MUST BE A CLEAR
MINIMUM OF 8" ABOVE DECK
ELECTRICAL PENETRATIONS (TYP)
FIELD VERIFY EXACT LOCATIONS
SIGN MOUNTING
LOCATION (TYP) FIELD
VERIFY EXACT
LOCATIONS
ROOF LINE
JOIST BEARING
ELEVATION LINE
REF BLDG ELEVATIONS
BOTTOM OF LETTERS
14'-5 3/4"
7
A2
SIM
THROUGH WALL
PROTECTION TUBE
FURNISHED BY WALMART
INSTALLED BY SIGN
CONTRACTOR INSTALL PER
MFR RECOMMENDATIONS
FULL BED OF MULTI-
COMPONENT SEALANT AT
PERIMETER OF CONDUIT
BY SIGN INSTALLER
INSTALL LETTER BACK
PRIOR TO INSTALLATION
BY SIGN INSTALLER
INDIVIDUAL PLASTIC
ILLUMINATED CHANNEL
LETTERS BY SIGN
SUPPLIER
INSTALL LETTER FACES
W/ SET SCREWS, TYP
BY SIGN INSTALLER
LOCATE ANCHORS AND WIRING/CONDUIT
PENETRATIONS PER SIGN ATTACHMENT
TEMPLATE PROVIDED BY WALMART
LOCATE CONDUIT PENETRATION 4'-0" MAX
FROM POWER SUPPLY. PROVIDE ONLY
ONE ROOF PENETRATION FOR ALL WHIPS.
EXISTING ROOFING SYSTEM
SEALANT ALL AROUND BY BUILDING
GENERAL CONTRACTOR
3/4" LIQUID TIGHT FLEXIBLE METAL CONDUIT
BY BUILDING GENERAL CONTRACTOR
PRE MOLDED PIPE FLASHING. ATTACH
PER ROOFING MFR RECOMMENDATIONS
BY BUILDING GENERAL CONTRACTOR
EXISTING WATERPROOFING MEMBRANE
HILTI HPS 1/4" X 1 5/8"
ANCHOR PROVIDED BY
WALMART AT EACH
SIGN CONNECTION
POINT INSTALLED BY
SIGN CONTRACTOR
SEALANT AT LOW VOLTAGE WIRE
PENETRATIONS BY SIGN CONTRACTOR
LOW VOLTAGE WIRE PENETRATIONS
BY SIGN CONTRACTOR
PREFERRED MOUNTING HEIGHT
12" MIN
3/4" CONDUIT TO PANEL
BOARD REF ELECTRICAL
SIGNAGE CONDUIT FLASHING AT LOW VOLTAGE WIRE
PENETRATIONS. PROVIDED BY WALMART INSTALLED BY
SIGN CONTRACTOR. REF INSTALLATION INSTRUCTIONS.
REMOTE POWER SUPPLY ENCLOSURE PROVIDED
AND INSTALLED BY SIGN CONTRACTOR
SEALANT AT PERIMETER AND ANCHORS OF REMOTE
POWER SUPPLY ENCLOSURE BY SIGN CONTRACTOR
12" MIN
TOP OF PARAPET
3' TO 4' ABOVE ROOF SURFACE
EXISTING STRUCTURE
architecture
2809 Ajax Avenue Suite 100
Rogers Arkansas 72758
Phone: 479.636.3545
Fax: 479.636.1209
+engineering
Architect of Record
STIPULATION FOR REUSE
THIS DRAWING WAS PREPARED FOR
USE ON A SPECIFIC SITE AT:
CONTEMPORANEOUSLY WITH ITS ISSUE
DATE ON AND IT IS NOT
SUITABLE FOR USE ON A DIFFERENT
PROJECT SITE OR AT A LATER TIME. USE
OF THIS DRAWING FOR REFERENCE OR
EXAMPLE ON ANOTHER PROJECT
REQUIRES THE SERVICES OF PROPERLY
LICENSED ARCHITECTS AND ENGINEERS.
REPRODUCTION OF THIS DRAWING FOR
REUSE ON ANOTHER PROJECT IS NOT
AUTHORIZED AND MAY BE CONTRARY TO
THE LAW.
DRAWN BY:
CHECKED BY:
DOCUMENT DATE:
SPECIAL PROJECT
PROTO CYCLE:
DOCUMENTS THAT DO NOT
HAVE THE ARCHITECT OR
ENGINEER OF RECORD SEAL
AND SIGNATURE SHALL BE
CONSIDERED NOT FOR
CONSTRUCTION
SHEET:
ISSUE BLOCK
William Douglas Hurley
Idaho License No. AR-984732
C:\Users\stevensetzer\Documents\03093_Meridian_Idaho_150R_Arch_R18_SPS_pb2.rvt
MERIDIAN, IDAHO
08-27-19
MERIDIAN, IDAHO
STORE NO.3093
JOB NUMBER: 2019-0587
AMR
DD
072619
08-27-19
ELEVATIONS
AND SIGNAGE
A2
1 1" = 20'-0"
FRONT ELEVATION
2 1" = 20'-0"
RIGHT ELEVATION
3 1" = 20'-0"
LEFT ELEVATION
4 1" = 20'-0"
REAR ELEVATION
5 1/4" = 1'-0"
SIGNAGE
6 1/4" = 1'-0"
PICKUP SIGN MOUNTING DIAGRAM
7 1 1/2" = 1'-0"
SIGN ATTACHMENT
NOTE:
PICKUP AND *SPARK WILL BE RELOCATED TO AREA OF NEW EXPANSION.
OUTDOOR LIVING SIGN WILL BE REMOVED FROM THE BUILDING.
3 11-06-19 CCD#1
4 11-22-19 CCD#2
4