Loading...
0070 - A2 ELEVATIONS AND SIGNAGE - 3093XXXX _______ A1.1 1 PICKUP AND SPARK SIGN TO BE RELOCATED TO NEW EXPANSION REF 3-A1.1 PATCH AND REPAIR SURFACES TO MATCH ADJACENT EXISTING SIGNAGE AND PAINT TO REMAIN UNLESS NOTED OTHERWISE _______ A1.1 3 EXISTING GARDEN CENTER WALL AND FENCE NOT SHOWN FOR CLARITY EXISTING SIGNAGE AND PAINT TO REMAIN UNLESS NOTED OTHERWISE NEW DOOR SLAB PAINTED TO MATCH ADJACENT WALL EXISTING DOOR SLAB AND FRAME TO REMAIN, PAINT TO MATCH ADJACENT WALL EXISTING SIGNAGE AND PAINT TO REMAIN UNLESS NOTED OTHERWISE EXISTING SIGNAGE AND PAINT TO REMAIN UNLESS NOTED OTHERWISE SIGNAGE GENERAL NOTES 1. BUILDING SIGNAGE FURNISHED BY WALMART, INSTALLED BY OTHERS. SITE DIRECTIONAL PLACARDS FURNISHED BY WALMART, INSTALLED BY G.C.; POLE FURNISHED AND INSTALLED BY G.C. PAVEMENT PAINT FURNISHED AND INSTALLED BY G.C. 2. GENERAL CONTRACTOR RESPONSIBILITIES: A. BY END OF FIRST WEEK OF CONSTRUCTION, REVIEW EXISTING CONSTRUCTION WHERE SIGN(S) WILL BE INSTALLED. IF EXISTING CONDITIONS DO NOT MATCH SIGN ATTACHMENT DETAILS SHOWN, REQUEST APPROVAL FROM CONSTRUCTION MANAGER TO SUBMIT RFI IN ACCORDANCE WITH SECTION 01255. NOTE DIFFERENCES IN CONSTRUCTION, INCLUDING DIMENSIONS, AND INCLUDE PHOTOGRAPHS FOR CLARIFICATION. B. PROVIDE JUNCTION BOXES AND CIRCUITRY TO NEW "Pickup" AND "spark" SIGNAGE. C. VERIFY VOLTAGE AT CIRCUITS FEEDING LIGHTED SIGNAGE. REFER TO ELECTRICAL. D. MAKE FINAL TERMINATIONS ON LIGHTED SIGNAGE. E. INSTALL CHECK-IN KIOSKS & COORDINATE W/ VENDOR. F. FOR SPECIAL PROJECTS, WHEN REQUIRED BY AHJ, G.C. IS RESPONSIBLE TO ACQUIRE SEPARATE PERMIT(S) FOR INSTALLATION OF SITE SIGNS. FOR REM PROJECTS, FOLLOW REM SIGN STANDARDS FOR PERMITS AND INSTALLATION. G. ALL SIGN PLACARDS FURNISHED BY WALMART AND INSTALLED BY GENERAL CONTRACTOR. ALL PAINT FOR PAVEMENT MARKINGS ARE SUPPLIED AND PAINTED BY THE GENERAL CONTRACTOR. 3. SIGNAGE CONTRACTOR RESPONSIBILITIES: A. FURNISH SPECIFIED CONDUIT FOR LIGHTED SIGNAGE. B. MAKE REQUIRED EXTERIOR WALL PENETRATIONS, INSTALL CONDUIT, AND SEAL PENETRATIONS PER SPECIFICATION SECTION 07900. C. INSTALL SIGNAGE PER DETAILS ON THIS SHEET. EXISTING SIGNAGE SCHEDULE COLOR WHITE YELLOW WHITE QTY WALMART 1 SIGNAGE LOCATION FRONT SIGNAGE *SPARK 1 Market 1 TOTAL AREA INDIVIDUAL AREA SIZE 5'-6" 8'-0" 298.00 SF 298.00 SF 2'-6" 28.17 SF 28.17 SF HomeWHITE & Pharmacy 1 2'-6" 97.66 SF 97.66 SF OutdoorWHITE Living 1 2'-6" 77.17 SF 77.17 SF TOTAL FRONT SIGNAGE 567.76 SF TIRE1WHITE & LUBE AUTO CENTER SIGNAGE 2'-0" TOTAL AUTO CENTER SIGNAGE 160.57 SF 28.94 SF 28.94 SF TOTAL FRONT SIGNAGE 728.33 SF TireWHITE 1 1'-0" 2.38 SF 4.76 SF LubeWHITE 2 1'-0" 3.13 SF 6.26 SF LIGHTED LED LED N/A N/A N/A N/A N/A N/A AGGREGATE SIGNAGE SCHEDULE SIGNAGE LOCATION QTY COLOR TOTAL AREA INDIVIDUAL AREA LIGHTED SIZE WHITE YELLOW Pickup 1 *SPARK 1 5'-6" 8'-0" 66.76 SF 66.76 SF LED LED WHITE YELLOW WALMART 1 *SPARK 1 3'-6" 5'-0" 120.61 SF 120.61 SF LED LED WHITE YELLOW WHITE WALMART ETR FRONT SIGNAGE *SPARK Market 5'-6" 8'-0" 298.00 SF 298.00 SF 2'-6" 28.17 SF 28.17 SF HomeWHITE & Pharmacy 2'-6" 97.66 SF 97.66 SF TOTAL FRONT SIGNAGE 490.59 SF TIREWHITE & LUBE AUTO CENTER SIGNAGE 2'-0" TOTAL AUTO CENTER SIGNAGE 160.57 SF 28.94 SF 28.94 SF TOTAL FRONT SIGNAGE 651.16 SF WHITE 1'-0" 2.38 SF 4.76 SF LubeWHITE 1'-0" 3.13 SF 6.26 SF LED LED N/A N/A N/A N/A N/A WHITE YELLOW Pickup *SPARK 5'-6" 8'-0" 66.76 SF 66.76 SF LED LED WHITE YELLOW WALMART *SPARK 3'-6" 5'-0" 120.61 SF 120.61 SF LED LED Tire ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR 65.43 SF WHITE PLASTIC LETTERS PLASTIC LETTERS MATCH SW #6904 "GUSTO GOLD" 2'-6" 4'-5 7/16" 14'-8 5/16" NOTE TO SIGN INSTALLER: ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED. IF MOUNTING THROUGH PRIMARY HOLE IS OBSTRUCTED BY REBAR, METAL STUDS, CHANNELS, OR OTHER MISC METAL, SEAL PRIMARY HOLE IN SIGN CAN AND MOUNT THROUGH THE NEAREST ALTERNATE MOUNTING HOLE. PRIMARY HOLES ARE INDICATED WITH PREDRILLED HOLES THROUGH WASHERS. ALTERNATE HOLES ARE INDICATED WITH WASHERS ONLY OR ARE OTHERWISE MARKED. NOTE: ALL SIGN PENETRATIONS ABOVE ROOF LEVEL MUST BE A CLEAR MINIMUM OF 8" ABOVE DECK ELECTRICAL PENETRATIONS (TYP) FIELD VERIFY EXACT LOCATIONS SIGN MOUNTING LOCATION (TYP) FIELD VERIFY EXACT LOCATIONS ROOF LINE JOIST BEARING ELEVATION LINE REF BLDG ELEVATIONS BOTTOM OF LETTERS 14'-5 3/4" 7 A2 SIM THROUGH WALL PROTECTION TUBE FURNISHED BY WALMART INSTALLED BY SIGN CONTRACTOR INSTALL PER MFR RECOMMENDATIONS FULL BED OF MULTI- COMPONENT SEALANT AT PERIMETER OF CONDUIT BY SIGN INSTALLER INSTALL LETTER BACK PRIOR TO INSTALLATION BY SIGN INSTALLER INDIVIDUAL PLASTIC ILLUMINATED CHANNEL LETTERS BY SIGN SUPPLIER INSTALL LETTER FACES W/ SET SCREWS, TYP BY SIGN INSTALLER LOCATE ANCHORS AND WIRING/CONDUIT PENETRATIONS PER SIGN ATTACHMENT TEMPLATE PROVIDED BY WALMART LOCATE CONDUIT PENETRATION 4'-0" MAX FROM POWER SUPPLY. PROVIDE ONLY ONE ROOF PENETRATION FOR ALL WHIPS. EXISTING ROOFING SYSTEM SEALANT ALL AROUND BY BUILDING GENERAL CONTRACTOR 3/4" LIQUID TIGHT FLEXIBLE METAL CONDUIT BY BUILDING GENERAL CONTRACTOR PRE MOLDED PIPE FLASHING. ATTACH PER ROOFING MFR RECOMMENDATIONS BY BUILDING GENERAL CONTRACTOR EXISTING WATERPROOFING MEMBRANE HILTI HPS 1/4" X 1 5/8" ANCHOR PROVIDED BY WALMART AT EACH SIGN CONNECTION POINT INSTALLED BY SIGN CONTRACTOR SEALANT AT LOW VOLTAGE WIRE PENETRATIONS BY SIGN CONTRACTOR LOW VOLTAGE WIRE PENETRATIONS BY SIGN CONTRACTOR PREFERRED MOUNTING HEIGHT 12" MIN 3/4" CONDUIT TO PANEL BOARD REF ELECTRICAL SIGNAGE CONDUIT FLASHING AT LOW VOLTAGE WIRE PENETRATIONS. PROVIDED BY WALMART INSTALLED BY SIGN CONTRACTOR. REF INSTALLATION INSTRUCTIONS. REMOTE POWER SUPPLY ENCLOSURE PROVIDED AND INSTALLED BY SIGN CONTRACTOR SEALANT AT PERIMETER AND ANCHORS OF REMOTE POWER SUPPLY ENCLOSURE BY SIGN CONTRACTOR 12" MIN TOP OF PARAPET 3' TO 4' ABOVE ROOF SURFACE  EXISTING STRUCTURE architecture 2809 Ajax Avenue Suite 100 Rogers Arkansas 72758 Phone: 479.636.3545 Fax: 479.636.1209 +engineering Architect of Record STIPULATION FOR REUSE THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE AT: CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW. DRAWN BY: CHECKED BY: DOCUMENT DATE: SPECIAL PROJECT PROTO CYCLE: DOCUMENTS THAT DO NOT HAVE THE ARCHITECT OR ENGINEER OF RECORD SEAL AND SIGNATURE SHALL BE CONSIDERED NOT FOR CONSTRUCTION SHEET: ISSUE BLOCK William Douglas Hurley Idaho License No. AR-984732 C:\Users\stevensetzer\Documents\03093_Meridian_Idaho_150R_Arch_R18_SPS_pb2.rvt MERIDIAN, IDAHO 08-27-19 MERIDIAN, IDAHO STORE NO.3093 JOB NUMBER: 2019-0587 AMR DD 072619 08-27-19 ELEVATIONS AND SIGNAGE A2 1 1" = 20'-0" FRONT ELEVATION 2 1" = 20'-0" RIGHT ELEVATION 3 1" = 20'-0" LEFT ELEVATION 4 1" = 20'-0" REAR ELEVATION 5 1/4" = 1'-0" SIGNAGE 6 1/4" = 1'-0" PICKUP SIGN MOUNTING DIAGRAM 7 1 1/2" = 1'-0" SIGN ATTACHMENT NOTE: PICKUP AND *SPARK WILL BE RELOCATED TO AREA OF NEW EXPANSION. OUTDOOR LIVING SIGN WILL BE REMOVED FROM THE BUILDING. 3 11-06-19 CCD#1 4 11-22-19 CCD#2 4