G-001_COVER SHEETUP PATH AND DIRECTION OF EXIT ACCESS w/ MAXIMUM TRAVEL DISTANCE. CPET= COMMON PATH OF EGRESS TRAVEL EATD= EXIT ACCESS TRAVEL DISTANCE FIRE EXTINGUISHER NOTES: • F.E. = 2A-10ABC FIRE EXTINGUISHER LOCATED AS SHOWN BRACKET MOUNTED WHERE APPROPRIATE • NO GREATER THAN 75 FEET TRAVEL TO ANY EXTINGUISHER LOCATIONS , FIRE EXTINGUISHER LOCATIONS MAY BE MODIFIED AS LONG AS THE TRAVEL DISTANCE REQUIREMENT IS MET • SEE LIGHTING PLAN FOR EMERGENCY LIGHTING & SPECIFICATIONS EGRESS NOTES: MEANS OF EGRESS DOORS SHALL MEET THE REQUIREMENTS OF SECTION 1010.1 EXCEPT AS SPECIFICALLY PERMITTED BY SECTION 1010.1, EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. SEC 1010.1.9 MAX TRAVEL DISTANCE EGRESS LEGEND 2048 SF NEW SHOP 3402 SF EXISTING SHOP 348 SF OFFICE 124 SF BREAK 63 SF RESTROOM EATD = 36' - 0" EATD = 69' - 0" SHEET NUMBER SHEET NAME G-001 COVER SHEET G-002 STANDARDS & ABBREV G-003 ADA STANDARDS G-004 ADA STANDARDS AD101 SITE PLAN - DEMO A-101 SITE PLAN - NEW A-111 FIRST FLOOR PLAN A-131 ROOF PLAN A-141 REFLECTED CEILING PLAN A-211 EXTERIOR ELEVATIONS A-311 BUILDING SECTIONS A-321 WALL SECTIONS A-421 INTERIOR ELEVATIONS A-501 SITE DETAILS A-511 EXTERIOR DETAILS A-521 INTERIOR DETAILS A-601 SCHEDULES 670 E King St, Meridian, ID 83642 BIG TWIN DIESEL EXPANSION 2,048 SQUARE FEET OF NEW SHOP CLIENT: JOB NUMBER CONSULTANT 725 E 2nd St Meridian, ID 83642 208.884.2824 PROFESSIONAL SEAL THIS DOCUMENT IS THE PROPERTY OF NEUDESIGN ARCHITECTURE, LLC AND IS NOT TO BE DUPLICATED WITHOUT WRITTEN AUTHORIZATION. © NEUDESIGN ARCHITECTURE LLC DRAWN BY NOT FOR PERMIT 19126 Big Twin Diesel Expansion 670 E King St, Meridian, ID 83642 G-001 Custom Steel Structures COVER SHEET EMC Vicinity Map: Project Team: PROJECT LOCATION Legal Description: TAX PARCEL # : R5672030450 LOT SIZE: 0.6830 ZONING: I-L TOWNSHIP: 3N, RANGE: 1E, SECTION: 07 NEUDESIGN ARCHITECTURE 725 E 2ND ST MERIDIAN, IDAHO 83642 TEL l 208.884.2824 STAMPING ARCHITECT CONTACT: EMAIL: PROJECT MANAGER CONTACT: EMAIL: ARCHITECT MATT MCANULTY ELECTRICAL CONSULTANT ELECTRICAL ENGINEERING COMPANY 800 S INDUSTRY WAY SUITE #350 MERIDIAN, IDAHO 83642 TEL l 208.378.4450 CONTACT: EMAIL: JEFF SMITH JSMITH@E2CO.COM CONTACT:CURT BARBER EMAIL:CURTCUSTOMSTEEL@YAHOO.COM CUSTOM STEEL STRUCTURES 2437 E CHALLIS ST MERIDIAN, ID 83646 TEL l 208.941.2150 CLIENT Code Analysis PROJECT NARRATIVE PROJECTS CONSISTS OF 2048 sf OF NEW METAL FRAMED SHOP SPACE. THE PROJECT WILL BE V-B TYPE CONSTRUCTION. BASIC DESIGN CRITERIA Seismic Design Category C; Roof Snow Load 25 psf; Wind Load 115 mph, Exposure C per IBC; Frost Depth 24” NUMBER OF STORIES/BUILDING HEIGHT 1 STORY, +-21' IN HEIGHT (2 STORIES ALLOWED, PER TABLE 503) TYPE OF CONSTRUCTION TYPE VB (TABLE 601) FIRE RESITIVE REQUIREMENTS 0-HR RATED CONSTRUCTION, COMBUSTIBLE MATERIALS OK (TABLE 601) INCIDENTAL ACCESSORY OCCUPANCIES - NONE NOTED (SECTION 508 & 508.3 & TABLE 508.4) AUTOMATIC SPRINKER SYSTEM NO EMERGENCY LIGHTS & EXIT SIGNS PER ELECTRICAL PLAN EXITS REQUIRED (2) REQUIRED, (2) PROVIDED (PER TABLE 1006.2.1 thru 1006.3.2(2) SPACES w/ (1) ALLOWED EXIT TO MEET TABLE 1006.3.2(2) SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY NONE NOTED (PER CHAPTER 4 - 402 MALLS; 403 HIGH RISE; 404 ATRIUMS; 405 UNDERGROUND; 406 MOTOR VEHICLE RELATED; 407 GROUP I-2; 408 GROUP I-3; 409 MOTION PICTURE PROJECTION ROOMS; 410 STAGES; 411 AMUSEMENT BUILDINGS; 412 AIRCRAFT RELATED; 413 HIGH-PILE & COMBUSTIBLE STORAGE; 414 HAZARDOUS MATERIALS; 415 GROUP H; 416 FLAMMABLE FINISHES; 417 DRYING ROOM; 418 ORGANIC COATING; 419 LIVE/WORK; 420 GROUPS I-1, R-1, R-2, R-3; 421 HYDROGEN CUTOFF ROOMS; 422 AMBULATORY HEALTH CARE; 423 STORM SHELTER; 424 CHILDREN'S PLAY STRUCTURES; 426 COMBUSTIBLE DUSTS) PROJECT AREA 3,937 sf EXISTING 2,048 sf NEW ALLOWABLE AREAS BY OCCUPANCY & AREA INCREASES 9,000sf ALLOWED > 2,048 sf PROPOSED = PASSES (NO FIRE SPRINKLER OR FRONTAGE INCREASES NEEDED PER 506.2/506.3) PLUMBING FIXTURE COUNT FOR OCCUPANCY (per TABLE 2902.1) ITEM WATERCLOSETS LAVATORIES BATHTUBS/SHOWERS DRINKING FOUNTAINS SERVICE SINKS (MOP/JAN) REQUIRED FOR MALE (PROVIDED AMOUNT IN PARENTHESIS) 1 REQUIRED (1 PROVIDED) 1 REQUIRED (1 PROVIDED) - 1 REQUIRED (0 PROVIDED) 1 REQUIRED (0 PROVIDED) NOTES • FIXTURE COUNTS TO BE PER 2015 IBC & 2017 IPC • OCCUPANT LOADS OF 10 OR FEWER, ONE TOILET FACILITY DESIGNED FOR USE BY ONE PERSON AT A TIME SHALL BE PERMITTED PER 2017 IPC 422.2 EXCEPTION 2 • OCCUPANT COUNTS OF 30 OR FEWER, A DRINKING FOUNTAIN WILL NOT BE REQUIRED PER 2017 IPC 415.2 AREAS & OCCUPANT LOAD FACTORS FLOOR AREA PER OCCUPANT (TABLE 1004.1.1) COMMON PATH OF TRAVEL (TABLE 1006.2.1) EXIT ACCESS TRAVEL DISTANCE (TABLE 1017.2) OCCUPANCY CLASSIFICATION DESCRIPTION AREA % OF TOTAL AREA LOAD FACTOR OCCUPANTS WITH SPRINKLER SYSTEM OL ≤ 30 OL ≥ 30 WITHOUT SPRINKLER SYSTEM WITH SPRINKLER SYSTEM B BUSINESS 348 SF 6% 100 GROSS 3.476 100 100 75 200 300 F-1 FACTORY/INDU STRIAL 2048 SF 34% 200 GROSS 10.241 100 75 75 200 250 S-1 STORAGE 3402 SF 57% 300 GROSS 11.341 100 100 75 200 250 S-1 STORAGE 124 SF 2% 300 GROSS 0.412 100 100 75 200 250 S-1 STORAGE 63 SF 1% 300 GROSS 0.210 100 100 75 200 250 TOTALS 5985 SF 25.680 APPLICABLE CODES 2015 International Building Code 2015 International Energy Code (Commercial) 2015 International Existing Building Code 2015 International Fire Code 2012 International Fuel Gas Code 2012 International Mechanical Code 2017 Idaho State Plumbing Code 2017 National Electrical Code 2009 ICC/ANSI /A117.1 NO. DESCRIPTION DATE A CLIENT REVIEW 07.30.19 1 1/16" = 1'-0" AREA PLAN MECHANICAL & PLUMBING CONSULTANT VALUE ENGINEERING, INC. 1406 N. MAIN STREET, STE# 107 MERIDIAN, IDAHO 83642 TEL l 208.258.7016 CONTACT: EMAIL: TYSON MCFALL TYSON@V-ENGINEERING.COM