Loading...
L1.0 Landscape Plan CZC10" ASH 10" ASH 10" ASH 10" ASH 3" PLUM 3" PLUM 7" MAPLE 7" MAPLE 8" PEAR 10" MAPLE 8" MAPLE 10" PEAR 12" MAPLE 10" PEAR 12" MAPLE 10" PEAR 7" MAPLE 10" PEAR 12" MAPLE 3' HGT. BERM 1 SB 1 VO 1 AP 1 BM 3 BM 1 AP 1 VO 1 SB 13 RF 10 PV 8 BT 6 VO 4 PY 11 VO 2 PY 13 SB 6 BM 4 L1.5 3 L1.5 1 L1.5 2 L1.5 3 BM 1 AP 1 VO 1 SB 3 AC 5 L1.5 PLANT SCHEDULE QTY KEY BOTANICAL NAME COMMON NAME SIZE NOTES DECIDUOUS SHADE TREES 3 AP Acer platanoides 'Columnarbroad' Parkway Maple 2" CAL. B&B Class II - 40' H x 25' W 3 AC Acer platanoides 'Crimson Sentry' Crimson Sentry Maple 2" CAL. B&B Class II - 25' H x 15' W ORNAMENTAL TREES 6 PY Pyrus calleryana 'Glen's Form' Chanticleer Pear 2" CAL. B&B Class I - 40' H x 15' W SHRUBS/PERENNIALS/ORNAMENTAL GRASSES 8 BT Berberis thunbergii 'Crimson Pygmy' Crimson Pygmy Dwarf Japanese Barberry #5 2' H x 3' W 13 BM Buxus microphylla var. koreana Wedding Ring Korean Boxwood #5 3' H x 3' W 10 PV Panicum virgatum 'Northwind' Northwind Switch Grass #1 6' H x 3' W 13 RF Rhamnus frangula 'Ron Williams' Fine Line Fern Leaf Buckthorn #5 6' H x 3' W 16 SB Spiraea x bumalda 'Goldflame' Goldflame Spirea #5 4' H x 4' W 18 VO Viburnum opulus 'Nanum' Dwarf European Cranberry Bush #5 3' H x 4' W LANDSCAPE LEGEND QUANTITY PLANT IDENTIFICATION KEY TREES/PLANTS TO BE INSTALLED EXISTING TREES TO REMAIN EXISTING TREES TO BE REMOVED CUT EDGE AS DETAILED PROPERTY LINE (VERIFY) EXISTING LIGHTPOLE TO REMAIN EXISTING FIRE HYDRANT TO REMAIN 2 QC EXISTING MAINTAINED LAWN AREAS TO REMAIN 1" MINUS BLACK PERMA BARK MULCH AT 3" DEPTH OVER TOPSOIL AS SPECIFIED. SEE PRE-EMERGENT HERBICIDE NOTES FOR APPLICATION SPECIFICATIONS SCALE: 0 1"= 10'-0" 10 10 20 30 CERTIFICATE OF ZONING COMPLIANCE LANDSCAPE PLAN SHEET OF # Sheet Number Drawing Title SEPT.2019 RE 2019-17; 19055 LP JOB NO: DATE: DRAWN BY: CHECKED BY: Seals C O P Y R I G H T A ll rig h ts re s e rv e d . R e p ro d u c tio n w ith o u t w ritte n p e rm is s io n o f A rchitecture N orthw est, P A is unlaw ful and subject to c rim in a l p ro s e c u tio n . RAND ALL HAVERFIELD A.I.. A 224 16th AVENUE SOUTH NAMPA, IDAHO 83651 OFFICE: (208) 467-3377 FAX: (208)467-4343 www.arcnw.com ARCHITECTURE N O R T H W E S T, P A MRK DATE DESCRIPTION 1 10/22/19 CITY COMMENTS 2 10/24/19 CITY COMMENTS MERIDIAN VETERINARY HOSPITAL P A R K I N G L O T E X P A N S I O N F O R: 4 1 5 W E S T F R A N K L I N, M E R I D I A N, I D A H O reandpartners.com + 208-514-3300 + 1014 S. La Pointe, Boise, Idaho 83706 LANDSCAPE ARCHITECTURE + URBAN DESIGN + LAND PLANNING + GRAPHIC COMMUNICATION + PROJECT MANAGEMENT LA-238 S T A T E O F I D A H O L I C E N S E D L A N D S C A P E A R C H I T E C T R O D N E Y P . E V A N S J R . PRELIMINARY NOT FOR C O N S T R U C T I O N CZC LANDSCAPE PLAN L1.0 PROJECT INFORMATION LANDSCAPE REQUIREMENTS TOTAL PROPERTY SIZE= 38,824 S.F. - 0.89 ACRES ZONING DISTRICT= C-G LOT IMPROVEMENTS AREA= 14,413 S.F. BUILDING COVERAGE: 7,199 S.F. HARDSCAPE COVERAGE: 25,424 S.F. LANDSCAPE COVERAGE: 6,201 S.F. NUMBER OF PARKING STALLS PROVIDED: 38 STANDARD STALLS 0 COMPACT STALLS 2 ADA STALLS TOTAL: 40 STALLS NUMBER OF BICYCLE PARKING SPACES REQUIRED: (1 STALLS/25 REQUIRED STALLS) = 2 BICYCLE STALLS NUMBER OF BICYCLE PARKING SPACES PROVIDED: PROPOSED ONE EXISTING RACK (ONE RACK = 7 STALLS) SETBACKS: WEST - 0 FEET NORTH - 0 FEET EAST - 0 FEET SOUTH - 0 FEET TOTAL NUMBER OF TREES: 9 PROPOSED; 14 EXISTING TOTAL NUMBER OF TREE SPECIES: 6 (3 EXISTING) ; 3 SPECIES REQUIRED PROVIDED PARKING LOT TREES - 6 LANDSCAPE BUFFER REQUIREMENTS: WEST PARKING LOT LANDSCAPE BUFFER (C-G): 97 LIN. FT. 5 FT. WIDTH PARKING BUFFER PROVIDED (5 FT. LANDSCAPE BUFFER REQUIRED) REQUIRED TREES - 3 PROVIDED TREES - 3 (EXISTING) NORTH BOUNDARY LANDSCAPE BUFFER (W FRANKLIN ROAD) 124 LIN. FT. 25 FT. BUFFER PROVIDED (25 FT. BUFFER REQUIRED) REQUIRED TREES - 4 PROVIDED TREES - 4 EAST PARKING LOT LANDSCAPE BUFFER (C-G) 97 LIN. FT. 5 FT. WIDTH BUFFER PROVIDED (5 FT. LANDSCAPE BUFFER REQUIRED) REQUIRED TREES - 3 PROVIDED TREES - 3 SOUTH BOUNDARY LANDSCAPE BUFFER (C-G): 124 LIN. FT. 20 FT. BUFFER PROVIDED (0 FT. LANDSCAPE BUFFER REQUIRED) REQUIRED TREES - 4 PROVIDED TREES - 4 (EXISTING) 1. VISION TRIANGLE 2. RETAIN AND PROTECT EXISTING TREE 3. RETAIN AND PROTECT EXISTING LANDSCAPE 4. CONTRACTOR SHALL REGRADE 3' FROM BACK OF SIDEWALK AND PATCH TURF SOD AS NEEDED 5. EXISTING BICYCLE STORAGE TO REMAIN 6. EXISTING TRASH ENCLOSURE TO REMAIN 7. EXISTING CHAINLINK FENCING TO REMAIN 8. EXISTING PEDESTRIAN GATE TO REMAIN 9. 3' HEIGHT, 3.5:1 SLOPE, LANDSCAPE BERM AS REQUIRED BY CITY OF MERIDIAN CALLOUT NOTES # CALLOUT NUMBERS REFER TO NUMBERED NOTES BELOW LANDSCAPE NOTES: 1. CONTRACTOR SHALL REPORT TO LANDSCAPE ARCHITECT ALL CONDITIONS WHICH IMPAIR AND/OR PREVENT THE PROPER EXECUTION OF THIS WORK, PRIOR TO BEGINNING WORK. 2. NO MATERIAL SUBSTITUTIONS SHALL BE MADE WITHOUT THE LANDSCAPE ARCHITECT'S PRIOR WRITTEN APPROVAL. ALTERNATE MATERIALS OF SIMILAR SIZE AND CHARACTER MAY BE CONSIDERED IF SPECIFIED PLANT MATERIALS CAN NOT BE OBTAINED. 3. COORDINATE ALL WORK WITH ALL OTHER SITE RELATED DEVELOPMENT DRAWINGS. 4. COORDINATE WORK SCHEDULE AND OBSERVATIONS WITH LANDSCAPE ARCHITECT PRIOR TO CONSTRUCTION START-UP. 5. ALL PLANT MATERIAL SHALL BE INSTALLED AS PER DETAILS. 6. ALL PLANT MATERIAL SHALL CONFORM TO THE AMERICAN NURSERYMAN STANDARDS FOR TYPE AND SIZE SHOWN. PLANTS WILL BE REJECTED IF NOT IN A SOUND AND HEALTHY CONDITION. 7. IN THE EVENT OF A PLANT COUNT DISCREPANCY, PLANT SYMBOLS SHALL OVERRIDE SCHEDULE QUANTITIES AND CALL OUT SYMBOL NUMBERS. 8. ALL PLANTING BEDS SHALL BE COVERED WITH A MINIMUM OF 3" DEPTH OF 1" MINUS BLACK PERMA BARK MULCH. APPLY PRE-EMERGENT HERBICIDE PRIOR TO MULCH APPLICATION. SUBMIT SAMPLE FOR APPROVAL. 9. ALL PLANT MATERIAL SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR BEGINNING AT THE DATE OF ACCEPTANCE BY THE OWNER. REPLACE ALL PLANT MATERIAL FOUND DEAD OR NOT IN A HEALTHY CONDITION IMMEDIATELY WITH THE SAME SIZE AND SPECIES AT NO COST TO THE OWNER. 10. FINISH GRADES SHALL PROVIDE A SMOOTH TRANSITION WITH ADJACENT SURFACES AND ENSURE POSITIVE DRAINAGE IN ACCORDANCE WITH THE SITE CIVIL GRADING PLAN. 11. AMEND EXISTING APPROVED TOPSOIL AT A RATIO OF THREE CUBIC YARDS OF APPROVED COMPOST PER 1000 SQUARE FEET. ROTO-TILL ORGANIC MATTER A MINIMUM OF 6 INCHES INTO TOPSOIL. 12. FERTILIZE ALL TREES AND SHRUBS WITH 'AGRIFORM' PLANTING TABLETS. QUANTITY PER MANUFACTURER'S RECOMMENDATIONS. 13. ALL PLANTING BEDS SHALL HAVE A MINIMUM 18" DEPTH OF TOPSOIL. LAWN AREAS SHALL HAVE A MINIMUM 12" DEPTH OF TOPSOIL. SPREAD, COMPACT, AND FINE GRADE TOPSOIL TO A SMOOTH AND UNIFORM GRADE 3" BELOW ADJACENT SURFACES OF PLANTER BED AREAS, 1-1/2" BELOW ADJACENT SURFACES OF TURF SOD AREAS, AND 1" BELOW ADJACENT SURFACES OF TURF SEED AREAS. 14. REUSE EXISTING TOPSOIL STOCKPILED ON THE SITE. SUPPLEMENT WITH IMPORTED TOPSOIL WHEN QUANTITIES ARE INSUFFICIENT. VERIFY SUITABILITY AND CONDITION OF TOPSOIL AS A GROWING MEDIUM. PERFORM SOIL TEST/ ANALYSIS AND PROVIDE ADDITIONAL AMENDMENT AS DETERMINED BY SOIL TESTS. TOPSOIL SHALL BE A LOOSE, FRIABLE, SANDY LOAM, CLEAN AND FREE OF TOXIC MATERIALS, NOXIOUS WEEDS, WEED SEEDS, ROCKS, GRASS OR OTHER FOREIGN MATERIAL AND A HAVE A PH OF 5.5 TO 7.0. IF ONSITE TOPSOIL DOES NOT MEET THESE MINIMUM STANDARDS, CONTRACTOR IS RESPONSIBLE TO EITHER: A) PROVIDE APPROVED IMPORTED TOPSOIL, OR B) IMPROVE ON-SITE TOPSOIL WITH METHODS APPROVED BY THE LANDSCAPE ARCHITECT. 15. IF IMPORTED TOPSOIL FROM OFF-SITE SOURCES IS REQUIRED, ENSURE IT IS FERTILE, FRIABLE, NATURAL LOAM, SURFACE SOIL, REASONABLY FREE OF SUBSOIL, CLAY LUMPS, BRUSH, WEEDS AND OTHER LITTER, AND FREE OF ROOTS, STUMPS, STONES LARGER THAN 2 INCHES IN ANY DIMENSION, AND OTHER EXTRANEOUS OR TOXIC MATTER HARMFUL TO PLANT GROWTH. A) OBTAIN TOPSOIL FROM LOCAL SOURCES OR FROM AREAS HAVING SIMILAR SOIL CHARACTERISTICS TO THOSE FOUND ON THE PROJECT SITE. OBTAIN TOPSOIL ONLY FROM NATURALLY, WELL-DRAINED SITES WHERE TOPSOIL OCCURS AT A DEPTH OF NOT LESS THAN 4 INCHES. B) REPRESENTATIVE SAMPLES SHALL BE TESTED FOR ACIDITY, FERTILITY, TOXICITY, AND GENERAL TEXTURE BY A RECOGNIZED COMMERCIAL OR GOVERNMENT AGENCY AND COPIES OF THE TESTING AGENCY'S FINDINGS AND RECOMMENDATIONS SHALL BE FURNISHED TO THE OWNER'S REPRESENTATIVE BY THE CONTRACTOR. NO TOPSOIL SHALL BE DELIVERED IN A FROZEN OR MUDDY CONDITION. ACIDITY/ALKALINITY RANGE - PH. 5.5 TO 7.6. 16. IMMEDIATELY CLEAN UP ANY TOPSOIL OR OTHER DEBRIS ON THE SITE CREATED FROM LANDSCAPE OPERATIONS AND DISPOSE OF PROPERLY OFF SITE. 17. TREES SHALL NOT BE PLANTED WITHIN THE 10'-0" CLEAR ZONE OF ALL STORM DRAIN PIPE, STRUCTURES, OR FACILITIES. 18. STORM DRAINAGE FACILITIES MUST BE PROTECTED FROM ANY AND ALL CONTAMINATION DURING THE CONSTRUCTION AND INSTALLATION OF THE LANDSCAPE IRRIGATION SYSTEM. 19. IN THE EVENT OF A DISCREPANCY, NOTIFY THE LANDSCAPE ARCHITECT IMMEDIATELY. 1. ALL LANDSCAPED AREAS SHALL HAVE AN AUTOMATIC UNDERGROUND SPRINKLER SYSTEM WHICH INSURES COMPLETE COVERAGE AND PROPERLY ZONED FOR REQUIRED WATER USES. EACH HYDROZONE IS TO BE IRRIGATED WITH SEPARATE INDIVIDUAL STATIONS. 2. PLANTER BEDS AND LAWN AREAS ARE TO HAVE SEPARATE HYDRO-ZONES. 3. POP-UP SPRINKLER HEADS SHALL HAVE A MINIMUM RISER HEIGHT OF 4 INCHES AT LAWN AREAS AND 18" AT PLANTER BEDS. 4. PLANTER BEDS ARE TO HAVE DRIP IRRIGATION SYSTEM OR POP-UP SPRAY SYSTEM. ANNUALS, PERENNIALS GROUND COVERS OR SHRUB MASSINGS SHALL HAVE A POP-UP SPRAY SYSTEM. 5. ELECTRONIC WATER DISTRIBUTION/ TIMING CONTROLLERS ARE TO BE PROVIDED. MINIMUM CONTROLLER REQUIREMENTS ARE AS FOLLOWS: a. PRECISE INDIVIDUAL STATION TIMING b. RUN TIME CAPABILITIES FOR EXTREMES IN PRECIPITATION RATES c. AT LEAST ONE PROGRAM FOR EACH HYDROZONE d. SUFFICIENT MULTIPLE CYCLES TO AVOID WATER RUN-OFF e. POWER FAILURE BACKUP FOR ALL PROGRAMED INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO PROVIDE WATER TO RESPECTIVE HYDRO-ZONES. 6. INDIVIDUAL VALVED WATERING STATIONS WILL BE DESIGNED AND INSTALLED TO PROVIDE WATER TO RESPECTIVE HYDRO-ZONES. 7. THE IRRIGATION SYSTEM SHALL BE DESIGNED TO PROVIDE 100% HEAD TO HEAD COVERAGE WITH TRIANGULAR SPACING. 8. SPRINKLER HEADS SHALL BE ADJUSTED TO REDUCE OVERSPRAY ONTO IMPERVIOUS SURFACES (BUILDINGS, SIDEWALKS, DRIVEWAYS, AND ASPHALT AREAS). 9. PROVIDE MINIMUM (1) QUICK COUPLER VALVE PER EACH (6) AUTOMATIC VALVE ZONES. APPROVE Q.C.V. LOCATIONS WITH LANDSCAPE ARCHITECT. IRRIGATION NOTES: 1. ALL AREAS TO BE PLANTED OR HYDROSEEDED SHALL HAVE WEED ABATEMENT OPERATIONS PERFORMED ON THEM PRIOR TO PLANTING OR HYDROSEEDING. 2. CONTRACTOR SHALL SPRAY ALL EXPOSED WEEDS WITH “ROUND-UP” (CONTACT HERBICIDE) OR APPROVED EQUAL. 3. DO NOT WATER FOR AT LEAST SEVEN (7) DAYS. REMOVE EXPOSED WEEDS FROM THE SITE. 4. CONTRACTOR SHALL OPERATE THE AUTOMATIC IRRIGATION SYSTEM FOR A PERIOD OF FOURTEEN (14) DAYS. AT CONCLUSION OF THIS WATERING PERIOD, DISCONTINUE WATERING FOR THREE TO FIVE (3-5) DAYS. 5. APPLY SECOND APPLICATION OF “ROUND-UP” TO ALL EXPOSED WEEDS. APPLY IN STRICT CONFORMANCE WITH MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS. DO NOT WATER FOR AT LEAST SEVEN (7) DAYS. REMOVE WEEDS FROM THE SITE. 6. IF ANY EVIDENCE OF WEED GERMINATION EXISTS AFTER TWO (2) APPLICATIONS, CONTRACTOR SHALL BE DIRECTED TO PERFORM A THIRD APPLICATION. 7. AT THE TIME OF PLANTING AND HYDROSEEDING, ALL PLANTING AREAS SHALL BE WEED FREE. WEED ABATEMENT NOTES: TREE MITIGATION NOTES: 1. THE EXISTING TREES TO BE REMOVED THAT REQUIRE MITIGATION ARE AS FOLLOWS FROM THE INTERIOR OF THE SITE (AS NOTED ON PLAN): - (2) 7" CAL. MAPLE - (2) 3" CAL. PLUM - (1) 8" CAL. PEAR TOTAL CALIPER INCHES REQUIRED FOR MITIGATION = 28 CALIPER INCHES EXISTING TREES TO BE SAVED ON SITE (WEST PROPERTY LINE) THAT WILL COUNT TOWARDS MITIGATION ARE AS FOLLOWS: - (4) 10" CAL. PEAR - (3) 12" CAL. MAPLE - (1) 7" CAL. MAPLE TOTAL CALIPER INCHES = 83 CALIPER INCHES 2. THE METHOD OF MITIGATION WILL BE TO USE THE EXISTING SAVED TREES' 83 CALIPER INCHES. THIS RESULTS IN AN ADDITIONAL 55 CALIPER INCHES NOT INCLUDING THE CALIPER INCHES OF THE REQUIRED PROPOSED TREES. 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 4 4 4 4 5 6 7 BEGIN 7 END 8 TREE PROTECTION NOTES: 1. PROTECT THE CRITICAL ROOT ZONE (THE AREA DIRECTLY BELOW THE DRIPLINE OF THE TREE) OF THE TREES TO REMAIN ON SITE BY: a. CONSTRUCTING A TEMPORARY CHAINLINK FENCE AROUND THE CRITICAL ROOT ZONE OF THE TREE TO BE PROTECTED PRIOR TO DEMOLITION, CONSTRUCTION, OR ANY SITE WORK. AS SHOWN ON PLANS. b. NOT ALLOWING COMPACTION BY EQUIPMENT TRAFFIC DURING CONSTRUCTION OR DURING DEMOLITION. c. NOT ALLOWING CONCRETE TRUCKS TO RINSE WITHIN THE PROTECTION AREA, OR ANYWHERE NEAR EXISTING TREE ROOTS OR IN PLANNED PLANTING BEDS AREAS. SEE EROSION AND SEDIMENT CONTROL PLAN FOR APPROVED CONCRETE WASHOUT AREAS. d. NOT STOCKPILING MATERIALS, DEBRIS, OR DIRT WITHIN THE TREE PROTECTION AREA. e. WATERING WITHIN THE CRITICAL ROOT ZONE FROM MID-APRIL TO MID-OCTOBER AT THE RATE OF NOT LESS THAN THE EQUIVALENT OF 1-1/2" OF WATER OVER THE ENTIRE AREA PER WEEK. f. NOT TRENCHING, EXCAVATING, FILLING, OR OTHERWISE DISTURBING THE SOIL WITHIN THE CRITICAL ROOT ZONE. g. ADJUST PROPOSED IMPROVEMENT LOCATIONS AS REQUIRED TO AVOID DAMAGING TREE ROOTS. 2. PROTECT THE CROWN AND TRUNK OF TREES TO BE RETAINED BY: a. OPERATING EQUIPMENT IN SUCH A WAY AS TO AVOID CONTACT WITH TREE TRUNKS OR BRANCHES. b. HAVING TREES PRUNED BY A LICENSED ARBORIST. c. WHERE EXCAVATION FOR NEW CONSTRUCTION IS REQUIRED WITHIN TREE PROTECTION ZONES AND APPROVED, HAND PRUNE OR UTILIZE ROOT PRUNING TECHNIQUES DESCRIBED BELOW PRIOR TO EXCAVATION. d. ROOT PRUNING: WHERE REQUIRED AND APPROVED, SHALL BE DONE MECHANICALLY WITH A ROOT PRUNING MACHINE, VIBRATORY PLOW, OR WITH A NARROW TRENCHER WITH SHARP BLADES. ONCE A TRENCH IS OPENED UP, ALL EXPOSED ROOTS WILL BE HAND PRUNED TO PROVIDE CLEAN-CUT ENDS. e. DO NOT CUT MAIN LATERAL ROOTS OR BUTTRESS ROOTS; CUT ONLY SMALLER ROOTS THAT INTERFERE WITH INSTALLATION OF UTILITIES. CUT ROOTS WITH SHARP PRUNING INSTRUMENTS; DO NOT BREAK OR PULL WITH BACKHOE OR SIMILAR EQUIPMENT. f. TREE PRUNING: TREES TO REMAIN THAT ARE AFFECTED BY TEMPORARY AND PERMANENT CONSTRUCTION SHALL BE PRUNED AS INDICATED. g. PRUNING STANDARDS: PRUNE TREES ACCORDING TO CURRENT ANSI A300 PRUNING STANDARDS. 3. REGRADING - GRADING LIMITATIONS WITHIN THE TREE PROTECTION ZONE a. GRADE CHANGES WITHIN THE TREE PROTECTION ZONE ARE NOT PERMITTED. b. GRADE CHANGES OUTSIDE THE TREE PROTECTION ZONE SHALL NOT SIGNIFICANTLY ALTER DRAINAGE. c. GRADE CHANGES UNDER SPECIFICALLY APPROVED CIRCUMSTANCES SHALL NOT ALLOW MORE THAN 6 INCHES OF FILL SOIL OR ALLOW MORE THAN 4 INCHES OF EXISTING SOIL TO BE REMOVED FROM NATURAL GRADE, UNLESS MITIGATED. d. GRADE FILLS OVER 6 INCHES OR IMPERVIOUS OVERLAY SHALL INCORPORATE AN APPROVED PERMANENT AERATION SYSTEM, PERMEABLE MATERIAL, OR OTHER APPROVED MITIGATION. e. GRADE CUTS EXCEEDING 4 INCHES SHALL INCORPORATE RETAINING WALLS OR AN APPROPRIATE TRANSITION EQUIVALENT. 4. ALL TREES THAT ARE DAMAGED, DESTROYED OR REMOVED DURING CONSTRUCTION SHALL BE MITIGATED USING THE MITIGATION STANDARDS PER THE MERIDIAN CITY CODE AS PER SECTION 11-3B-10. 5. SEE TREE MITIGATION NOTES FOR ADDITIONAL INFORMATION. 3 3 9 9 9